Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 142
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Phys Rev Lett ; 127(10): 104801, 2021 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-34533351

RESUMEN

Hollow plasma channels are attractive for lepton acceleration because they provide intrinsic emittance preservation regimes. However, beam breakup instabilities dominate the dynamics. Here, we show that thin, warm hollow channels can sustain large-amplitude plasma waves ready for high-quality positron acceleration. We verify that the combination of warm electrons and thin hollow channels enables positron focusing structures. Such focusing wakefields unlock beam breakup damping mechanisms. We demonstrate that such channels emerge self-consistently during the long-term plasma dynamics in the blowout's regime aftermath, allowing for experimental demonstration.

2.
Nature ; 524(7566): 442-5, 2015 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-26310764

RESUMEN

Electrical breakdown sets a limit on the kinetic energy that particles in a conventional radio-frequency accelerator can reach. New accelerator concepts must be developed to achieve higher energies and to make future particle colliders more compact and affordable. The plasma wakefield accelerator (PWFA) embodies one such concept, in which the electric field of a plasma wake excited by a bunch of charged particles (such as electrons) is used to accelerate a trailing bunch of particles. To apply plasma acceleration to electron-positron colliders, it is imperative that both the electrons and their antimatter counterpart, the positrons, are efficiently accelerated at high fields using plasmas. Although substantial progress has recently been reported on high-field, high-efficiency acceleration of electrons in a PWFA powered by an electron bunch, such an electron-driven wake is unsuitable for the acceleration and focusing of a positron bunch. Here we demonstrate a new regime of PWFAs where particles in the front of a single positron bunch transfer their energy to a substantial number of those in the rear of the same bunch by exciting a wakefield in the plasma. In the process, the accelerating field is altered--'self-loaded'--so that about a billion positrons gain five gigaelectronvolts of energy with a narrow energy spread over a distance of just 1.3 metres. They extract about 30 per cent of the wake's energy and form a spectrally distinct bunch with a root-mean-square energy spread as low as 1.8 per cent. This ability to transfer energy efficiently from the front to the rear within a single positron bunch makes the PWFA scheme very attractive as an energy booster to an electron-positron collider.

3.
Int J Food Sci Nutr ; 72(6): 816-832, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33455470

RESUMEN

Personalised nutrition (PN) products and services have the potential to enhance the health and quality of life of older adults. However, PN innovation is challenging and requires specific competencies and supportive collaborations. This paper reports findings from a Collective Intelligence Scenario-Based Design session conducted with PN experts as part of the Horizon 2020 project INCluSilver, which aims to support the development of products, services, and systems that improve the health and quality of life of older adults through innovation in PN. Experts identified challenges to the design of PN products and services and barriers that small and medium enterprises (SMEs) face when innovating PN products and services for older adults. Options to address these barriers were generated and specific SME competencies supporting PN innovation were identified. This study provides a useful framework for understanding the challenges, opportunities, and key competencies needed to innovate PN products and services for older adults.


Asunto(s)
Dieta , Estado Nutricional , Calidad de Vida , Anciano , Dietética , Humanos
4.
Nature ; 515(7525): 92-5, 2014 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-25373678

RESUMEN

High-efficiency acceleration of charged particle beams at high gradients of energy gain per unit length is necessary to achieve an affordable and compact high-energy collider. The plasma wakefield accelerator is one concept being developed for this purpose. In plasma wakefield acceleration, a charge-density wake with high accelerating fields is driven by the passage of an ultra-relativistic bunch of charged particles (the drive bunch) through a plasma. If a second bunch of relativistic electrons (the trailing bunch) with sufficient charge follows in the wake of the drive bunch at an appropriate distance, it can be efficiently accelerated to high energy. Previous experiments using just a single 42-gigaelectronvolt drive bunch have accelerated electrons with a continuous energy spectrum and a maximum energy of up to 85 gigaelectronvolts from the tail of the same bunch in less than a metre of plasma. However, the total charge of these accelerated electrons was insufficient to extract a substantial amount of energy from the wake. Here we report high-efficiency acceleration of a discrete trailing bunch of electrons that contains sufficient charge to extract a substantial amount of energy from the high-gradient, nonlinear plasma wakefield accelerator. Specifically, we show the acceleration of about 74 picocoulombs of charge contained in the core of the trailing bunch in an accelerating gradient of about 4.4 gigavolts per metre. These core particles gain about 1.6 gigaelectronvolts of energy per particle, with a final energy spread as low as 0.7 per cent (2.0 per cent on average), and an energy-transfer efficiency from the wake to the bunch that can exceed 30 per cent (17.7 per cent on average). This acceleration of a distinct bunch of electrons containing a substantial charge and having a small energy spread with both a high accelerating gradient and a high energy-transfer efficiency represents a milestone in the development of plasma wakefield acceleration into a compact and affordable accelerator technology.

5.
Phys Rev Lett ; 123(13): 134801, 2019 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-31697514

RESUMEN

An intense, subpicosecond, relativistic electron beam traversing a dielectric-lined waveguide generates very large amplitude electric fields at terahertz (THz) frequencies through the wakefield mechanism. In recent work employing this technique to accelerate charged particles, the generation of high-power, narrow-band THz radiation was demonstrated. The radiated waves contain fields with measured amplitude exceeding 2 GV/m, orders of magnitude greater than those available by other THz generation techniques at a narrow bandwidth. For fields approaching the GV/m level, a strong damping has been observed in SiO_{2}. This wave attenuation with an onset near 850 MV/m is consistent with changes to the conductivity of the dielectric lining and is characterized by a distinctive latching mechanism that is reversible on longer timescales. We describe the detailed measurements that serve to clarify the underlying physical mechanisms leading to strong field-induced damping of THz radiation (hω=1.59 meV, f=0.38 THz) in SiO_{2}, a bulk, wide band-gap (8.9 eV) dielectric.

6.
Phys Rev Lett ; 122(19): 190404, 2019 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-31144933

RESUMEN

We demonstrate the experimental feasibility of probing the fully nonperturbative regime of quantum electrodynamics with a 100 GeV-class particle collider. By using tightly compressed and focused electron beams, beamstrahlung radiation losses can be mitigated, allowing the particles to experience extreme electromagnetic fields. Three-dimensional particle-in-cell simulations confirm the viability of this approach. The experimental forefront envisaged has the potential to establish a novel research field and to stimulate the development of a new theoretical methodology for this yet unexplored regime of strong-field quantum electrodynamics.

7.
Philos Trans A Math Phys Eng Sci ; 377(2151): 20190215, 2019 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-31230575

RESUMEN

This introductory article is a synopsis of the status and prospects of particle-beam-driven plasma wakefield acceleration (PWFA). Conceptual and experimental breakthroughs obtained over the last years have initiated a rapid growth of the research field, and increased maturity of underlying technology allows an increasing number of research groups to engage in experimental R&D. We briefly describe the fundamental mechanisms of PWFA, from which its chief attractions arise. Most importantly, this is the capability of extremely rapid acceleration of electrons and positrons at gradients many orders of magnitude larger than in conventional accelerators. This allows the size of accelerator units to be shrunk from the kilometre to metre scale, and possibly the quality of accelerated electron beam output to be improved by orders of magnitude. In turn, such compact and high-quality accelerators are potentially transformative for applications across natural, material and life sciences. This overview provides contextual background for the manuscripts of this issue, resulting from a Theo Murphy meeting held in the summer of 2018. This article is part of the Theo Murphy meeting issue 'Directions in particle beam-driven plasma wakefield acceleration'.

8.
Philos Trans A Math Phys Eng Sci ; 377(2151): 20180184, 2019 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-31230576

RESUMEN

This paper discusses the properties of electron beams formed in plasma wakefield accelerators through ionization injection. In particular, the potential for generating a beam composed of co-located multi-colour beamlets is demonstrated in the case where the ionization is initiated by the evolving charge field of the drive beam itself. The physics of the processes of ionization and injection are explored through OSIRIS simulations. Experimental evidence showing similar features are presented from the data obtained in the E217 experiment at the FACET facility of the SLAC National Laboratory. This article is part of the Theo Murphy meeting issue 'Directions in particle beam-driven plasma wakefield acceleration'.

9.
Philos Trans A Math Phys Eng Sci ; 377(2151): 20180173, 2019 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-31230577

RESUMEN

Beam-driven plasma wakefield acceleration (PWFA) has demonstrated significant progress during the past two decades of research. The new Facility for Advanced Accelerator Experimental Tests (FACET) II, currently under construction, will provide 10 GeV electron beams with unprecedented parameters for the next generation of PWFA experiments. In the context of the FACET II facility, we present simulation results on expected betatron radiation and its potential application to diagnose emittance preservation and hosing instability in the upcoming PWFA experiments. This article is part of the Theo Murphy meeting issue 'Directions in particle beam-driven plasma wakefield acceleration'.

10.
Phys Rev Lett ; 120(12): 124802, 2018 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-29694092

RESUMEN

Hollow channel plasma wakefield acceleration is a proposed method to provide high acceleration gradients for electrons and positrons alike: a key to future lepton colliders. However, beams which are misaligned from the channel axis induce strong transverse wakefields, deflecting beams and reducing the collider luminosity. This undesirable consequence sets a tight constraint on the alignment accuracy of the beam propagating through the channel. Direct measurements of beam misalignment-induced transverse wakefields are therefore essential for designing mitigation strategies. We present the first quantitative measurements of transverse wakefields in a hollow plasma channel, induced by an off-axis 20 GeV positron bunch, and measured with another 20 GeV lower charge trailing positron probe bunch. The measurements are largely consistent with theory.

11.
Age Ageing ; 47(6): 847-852, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-30084877

RESUMEN

In an observational longitudinal study of a sub-sample of the Aberdeen 1936 birth cohort, from age 62 to 77 years, we investigated childhood intelligence, social class, education, life-course social mobility, memory test performance and memory decline in late life. We examined 388 local residents who had attended school in Aberdeen in 1947 and measured Auditory-Verbal Learning Test (AVLT) at recruitment age about 64 years and up to five times until age about 77 years. Better performance at age about 64 on AVLT was predicted by early socioeconomic status (SES), social mobility and childhood intelligence. The trajectory of AVLT decline was steeper in those who had received less education. This relationship was independent of childhood ability, sex, SES in childhood and social mobility. The protection of memory by education suggests that education supports resilience to age-related cognitive impairment. Upward social mobility does not enhance this effect, suggesting that resilience to age-related decline may be established in early life.


Asunto(s)
Envejecimiento Cognitivo/psicología , Escolaridad , Inteligencia , Trastornos de la Memoria/psicología , Memoria , Clase Social , Determinantes Sociales de la Salud , Factores de Edad , Anciano , Niño , Femenino , Humanos , Estudios Longitudinales , Masculino , Trastornos de la Memoria/diagnóstico , Trastornos de la Memoria/etiología , Persona de Mediana Edad , Factores Protectores , Resiliencia Psicológica , Factores de Riesgo , Escocia , Movilidad Social
12.
Phys Rev Lett ; 119(2): 024801, 2017 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-28753348

RESUMEN

We report on the first experimental observations of quasichanneling oscillations, recently seen in simulations and described theoretically. Although above-barrier particles penetrating a single crystal are generally seen as behaving almost as in an amorphous substance, distinct oscillation peaks nevertheless appear for particles in that category. The quasichanneling oscillations were observed at SLAC National Accelerator Laboratory by aiming 20.35 GeV positrons and electrons at a thin silicon crystal bent to a radius of R=0.15 m, exploiting the quasimosaic effect. For electrons, two relatively faint quasichanneling peaks were observed, while for positrons, seven quasichanneling peaks were clearly identified.

13.
Phys Rev Lett ; 116(12): 124801, 2016 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-27058082

RESUMEN

Phase space matching between two plasma-based accelerator (PBA) stages and between a PBA and a traditional accelerator component is a critical issue for emittance preservation. The drastic differences of the transverse focusing strengths as the beam propagates between stages and components may lead to a catastrophic emittance growth even when there is a small energy spread. We propose using the linear focusing forces from nonlinear wakes in longitudinally tailored plasma density profiles to control phase space matching between sections with negligible emittance growth. Several profiles are considered and theoretical analysis and particle-in-cell simulations show how these structures may work in four different scenarios. Good agreement between theory and simulation is obtained, and it is found that the adiabatic approximation misses important physics even for long profiles.

14.
Phys Rev Lett ; 112(2): 025001, 2014 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-24484020

RESUMEN

We show through experiments and supporting simulations that propagation of a highly relativistic and dense electron bunch through a plasma can lead to distributed injection of electrons, which depletes the accelerating field, i.e., beam loads the wake. The source of the injected electrons is ionization of the second electron of rubidium (Rb II) within the wake. This injection of excess charge is large enough to severely beam load the wake, and thereby reduce the transformer ratio T. The reduction of the average T with increasing beam loading is quantified for the first time by measuring the ratio of peak energy gain and loss of electrons while changing the beam emittance. Simulations show that beam loading by Rb II electrons contributes to the reduction of the peak accelerating field from its weakly loaded value of 43 GV/m to a strongly loaded value of 26 GV/m.

15.
Nat Commun ; 14(1): 1054, 2023 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-36828817

RESUMEN

Electron beam quality is paramount for X-ray pulse production in free-electron-lasers (FELs). State-of-the-art linear accelerators (linacs) can deliver multi-GeV electron beams with sufficient quality for hard X-ray-FELs, albeit requiring km-scale setups, whereas plasma-based accelerators can produce multi-GeV electron beams on metre-scale distances, and begin to reach beam qualities sufficient for EUV FELs. Here we show, that electron beams from plasma photocathodes many orders of magnitude brighter than state-of-the-art can be generated in plasma wakefield accelerators (PWFAs), and then extracted, captured, transported and injected into undulators without significant quality loss. These ultrabright, sub-femtosecond electron beams can drive hard X-FELs near the cold beam limit to generate coherent X-ray pulses of attosecond-Angstrom class, reaching saturation after only 10 metres of undulator. This plasma-X-FEL opens pathways for advanced photon science capabilities, such as unperturbed observation of electronic motion inside atoms at their natural time and length scale, and towards higher photon energies.


Asunto(s)
Electrones , Aceleradores de Partículas , Rayos X , Rayos Láser , Fotones
16.
Sci Rep ; 11(1): 2945, 2021 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-33536504

RESUMEN

Longitudinal phase space (LPS) provides a critical information about electron beam dynamics for various scientific applications. For example, it can give insight into the high-brightness X-ray radiation from a free electron laser. Existing diagnostics are invasive, and often times cannot operate at the required resolution. In this work we present a machine learning-based Virtual Diagnostic (VD) tool to accurately predict the LPS for every shot using spectral information collected non-destructively from the radiation of relativistic electron beam. We demonstrate the tool's accuracy for three different case studies with experimental or simulated data. For each case, we introduce a method to increase the confidence in the VD tool. We anticipate that spectral VD would improve the setup and understanding of experimental configurations at DOE's user facilities as well as data sorting and analysis. The spectral VD can provide confident knowledge of the longitudinal bunch properties at the next generation of high-repetition rate linear accelerators while reducing the load on data storage, readout and streaming requirements.

17.
Nat Commun ; 11(1): 4753, 2020 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-32958741

RESUMEN

Metre-scale plasma wakefield accelerators have imparted energy gain approaching 10 gigaelectronvolts to single nano-Coulomb electron bunches. To reach useful average currents, however, the enormous energy density that the driver deposits into the wake must be removed efficiently between shots. Yet mechanisms by which wakes dissipate their energy into surrounding plasma remain poorly understood. Here, we report picosecond-time-resolved, grazing-angle optical shadowgraphic measurements and large-scale particle-in-cell simulations of ion channels emerging from broken wakes that electron bunches from the SLAC linac generate in tenuous lithium plasma. Measurements show the channel boundary expands radially at 1 million metres-per-second for over a nanosecond. Simulations show that ions and electrons that the original wake propels outward, carrying 90 percent of its energy, drive this expansion by impact-ionizing surrounding neutral lithium. The results provide a basis for understanding global thermodynamics of multi-GeV plasma accelerators, which underlie their viability for applications demanding high average beam current.

18.
J Vet Cardiol ; 19(4): 396-403, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28734621

RESUMEN

A 9-month old castrated male Labradoodle presented to the cardiology service at Purdue University for evaluation of a low-grade murmur. Physical examination, thoracic radiography, and echocardiography were strongly supportive of an extracardiac left-to-right shunt. Subsequent evaluation with nuclear scintigraphy and computed tomography angiography revealed a large, complex arteriovenous malformation within the cranial abdomen. Staged interventional attenuation of the shunt was performed using n-butyl cyanoacrylate that resulted in a reduction in echocardiographic and nuclear scintigraphy derived shunt estimation.


Asunto(s)
Malformaciones Arteriovenosas/veterinaria , Enfermedades de los Perros/tratamiento farmacológico , Embolización Terapéutica/veterinaria , Enbucrilato/uso terapéutico , Animales , Malformaciones Arteriovenosas/tratamiento farmacológico , Perros , Ecocardiografía/veterinaria , Procedimientos Endovasculares , Masculino
19.
Sci Rep ; 7(1): 14180, 2017 10 27.
Artículo en Inglés | MEDLINE | ID: mdl-29079817

RESUMEN

High gradients of energy gain and high energy efficiency are necessary parameters for compact, cost-efficient and high-energy particle colliders. Plasma Wakefield Accelerators (PWFA) offer both, making them attractive candidates for next-generation colliders. In these devices, a charge-density plasma wave is excited by an ultra-relativistic bunch of charged particles (the drive bunch). The energy in the wave can be extracted by a second bunch (the trailing bunch), as this bunch propagates in the wake of the drive bunch. While a trailing electron bunch was accelerated in a plasma with more than a gigaelectronvolt of energy gain, accelerating a trailing positron bunch in a plasma is much more challenging as the plasma response can be asymmetric for positrons and electrons. We report the demonstration of the energy gain by a distinct trailing positron bunch in a plasma wakefield accelerator, spanning nonlinear to quasi-linear regimes, and unveil the beam loading process underlying the accelerator energy efficiency. A positron bunch is used to drive the plasma wake in the experiment, though the quasi-linear wake structure could as easily be formed by an electron bunch or a laser driver. The results thus mark the first acceleration of a distinct positron bunch in plasma-based particle accelerators.

20.
Stroke ; 37(7): 1771-7, 2006 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-16763182

RESUMEN

BACKGROUND AND PURPOSE: We investigated whether computed tomography (CT) perfusion-derived cerebral blood flow (CBF) and cerebral blood volume (CBV) could be used to differentiate between penumbra and infarcted gray matter in a limited, exploratory sample of acute stroke patients. METHODS: Thirty patients underwent a noncontrast CT (NCCT), CT angiography (CTA), and CT perfusion (CTP) scan within 7 hours of stroke onset, NCCT and CTA at 24 hours, and NCCT at 5 to 7 days. Twenty-five patients met the criteria for inclusion and were subsequently divided into 2 groups: those with recanalization at 24 hours (n=16) and those without (n=9). Penumbra was operationally defined as tissue with an admission CBF <25 mL x 100 g(-1) x min(-1) that was not infarcted on the 5- to 7-day NCCT. Logistic regression was applied to differentiate between infarct and penumbra data points. RESULTS: For recanalized patients, CBF was significantly lower (P<0.05) for infarct (13.3+/-3.75 mL x 100 g(-1) x min(-1)) than penumbra (25.0+/-3.82 mL x 100 g(-1) x min(-1)). CBV in the penumbra (2.15+/-0.43 mL x 100 g(-1)) was significantly higher than contralateral (1.78+/-0.30 mL x 100 g(-1)) and infarcted tissue (1.12+/-0.37 mL x 100 g(-1)). Logistic regression using an interaction term (CBFxCBV) resulted in sensitivity, specificity, and accuracy of 97.0%, 97.2%, and 97.1%, respectively. The interaction term resulted in a significantly better (P<0.05) fit than CBF or CBV alone, suggesting that the CBV threshold for infarction varies with CBF. For patients without recanalization, CBF and CBV for infarcted regions were 15.1+/-5.67 mL x 100 g(-1) x min(-1) and 1.17+/-0.41 mL x 100 g(-1), respectively. CONCLUSIONS: We have shown in a limited sample of patients that CBF and CBV obtained from CTP can be sensitive and specific for infarction and should be investigated further in a prospective trial to assess their utility for differentiating between infarct and penumbra.


Asunto(s)
Velocidad del Flujo Sanguíneo , Volumen Sanguíneo , Isquemia Encefálica/diagnóstico por imagen , Angiografía Cerebral/métodos , Circulación Cerebrovascular , Infarto de la Arteria Cerebral Media/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Enfermedad Aguda , Adulto , Anciano , Anciano de 80 o más Años , Isquemia Encefálica/fisiopatología , Supervivencia Celular , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Infarto de la Arteria Cerebral Media/fisiopatología , Masculino , Persona de Mediana Edad , Perfusión , Reperfusión , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA