Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Eur J Appl Physiol ; 118(5): 911-918, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29435760

RESUMEN

PURPOSE: The self-paced maximal oxygen uptake test (SPV) may offer effective training prescription metrics for athletes. This study aimed to examine whether SPV-derived data could be used for training prescription. METHODS: Twenty-four recreationally active male and female runners were randomly assigned between two training groups: (1) Standardised (STND) and (2) Self-Paced (S-P). Participants completed 4 running sessions a week using a global positioning system-enabled (GPS) watch: 2 × interval sessions; 1 × recovery run; and 1 × tempo run. STND had training prescribed via graded exercise test (GXT) data, whereas S-P had training prescribed via SPV data. In STND, intervals were prescribed as 6 × 60% of the time that velocity at [Formula: see text] ([Formula: see text]) could be maintained (Tmax). In S-P, intervals were prescribed as 7 × 120 s at the mean velocity of rating of perceived exertion 20 (vRPE20). Both groups used 1:2 work:recovery ratio. Maximal oxygen uptake ([Formula: see text]), [Formula: see text], Tmax, vRPE20, critical speed (CS), and lactate threshold (LT) were determined before and after the 6-week training. RESULTS: STND and S-P training significantly improved [Formula: see text] by 4 ± 8 and 6 ± 6%, CS by 7 ± 7 and 3 ± 3%; LT by 5 ± 4% and 7 ± 8%, respectively (all P < .05), with no differences observed between groups. CONCLUSIONS: Novel metrics obtained from the SPV can offer similar training prescription and improvement in [Formula: see text], CS and LT compared to training derived from a traditional GXT.


Asunto(s)
Consumo de Oxígeno , Acondicionamiento Físico Humano/métodos , Carrera/fisiología , Adulto , Femenino , Humanos , Masculino , Acondicionamiento Físico Humano/efectos adversos
2.
Int J Sports Physiol Perform ; 10(2): 172-7, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25010089

RESUMEN

PURPOSE: The novel self-paced maximal-oxygen-uptake (VO2max) test (SPV) may be a more suitable alternative to traditional maximal tests for elite athletes due to the ability to self-regulate pace. This study aimed to examine whether the SPV can be administered on a motorized treadmill. METHODS: Fourteen highly trained male distance runners performed a standard graded exercise test (GXT), an incline-based SPV (SPVincline), and a speed-based SPV (SPVspeed). The GXT included a plateau-verification stage. Both SPV protocols included 5×2-min stages (and a plateau-verification stage) and allowed for self-pacing based on fixed increments of rating of perceived exertion: 11, 13, 15, 17, and 20. The participants varied their speed and incline on the treadmill by moving between different marked zones in which the tester would then adjust the intensity. RESULTS: There was no significant difference (P=.319, ES=0.21) in the VO2max achieved in the SPVspeed (67.6±3.6 mL·kg(-1)·min(-1), 95%CI=65.6-69.7 mL·kg(-1)·min(-1)) compared with that achieved in the GXT (68.6±6.0 mL·kg(-1)·min(-1), 95%CI=65.1-72.1 mL·kg(-1)·min(-1)). Participants achieved a significantly higher VO2max in the SPVincline (70.6±4.3 mL·kg(-1)·min(-1), 95%CI=68.1-73.0 mL·kg(-1)·min(-1)) than in either the GXT (P=.027, ES=0.39) or SPVspeed (P=.001, ES=0.76). CONCLUSIONS: The SPVspeed protocol produces VO2max values similar to those obtained in the GXT and may represent a more appropriate and athlete-friendly test that is more oriented toward the variable speed found in competitive sport.


Asunto(s)
Prueba de Esfuerzo/métodos , Consumo de Oxígeno , Resistencia Física/fisiología , Carrera/fisiología , Adulto , Conducta Competitiva/fisiología , Humanos , Masculino , Percepción , Esfuerzo Físico/fisiología , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA