Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
Electrophoresis ; 2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38577828

RESUMEN

Capillary electrophoresis (CE) interfaced to mass spectrometry (MS) with electrospray ionization typically incorporates acidic additives or organic solvents to assist in ionization. Vibrating sharp-edge spray ionization (VSSI) is a voltage-free method to interface CE and MS that does not require these additives, making it appealing for protein analyses. CE-VSSI nanoflow sheath separations are performed with low ionic strength aqueous solutions in the sheath to reduce suppression. Serine is also included in the sheath to reduce analyte adduction. Proteins are detected in the 2.5-10 µM range, corresponding to an injected mass range of 0.1-1.2 ng. The anionic proteins ß-lactoglobulin and transferrin are resolved using an unmodified fused silica capillary because they do not exhibit nonspecific surface adsorption. Conversely, separations of cationic proteins cytochrome c, ribonuclease A, and α-chymotrypsinogen A in an unmodified capillary require acidic background electrolytes to overcome adsorption. Alternatively, a semipermanent coating comprised self-assembled lipids overcomes surface adsorption at a neutral pH. Separations with zwitterionic and hybrid cationic coatings are complete within 15 or 6 min, respectively. The dimeric form of triosephosphate isomerase was observed at a 60 µM, corresponding to a mass of 19 ng, by dropping the temperature of the MS inlet.

2.
J Chem Educ ; 100(7): 2782-2788, 2023 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-37455796

RESUMEN

Electrophoresis is integral to analytical and biochemistry experiences in undergraduate education; however, fundamental principles of the method are often taught in upper-level laboratories through hands-on experiences. A laboratory activity is reported that teaches the concepts of electrophoretic mobility and electroosmotic flow. A single reuseable instrument, called a mini-E, costs 37 USD and consists of a DC power supply, a voltmeter, platinum electrodes, and a chip cast in polydimethylsiloxane. This activity uses common reagents costing only 0.02 USD per student. Experiments are devised that allow students to investigate the properties of electrophoretic flow and electroosmotic flow by separating the two commonly used food dyeing agents Brilliant Blue FCF and Allura Red AC in vinegar and in a solution of ammonium hydroxide. A dark-purple mixture of these dyes is separated into red and blue bands that are easily visualized. The migration order of the dyes differs when the separation is performed under conditions of reversed polarity and suppressed electroosmotic flow (vinegar) compared to conditions of normal polarity and active electroosmotic flow (ammonium hydroxide). When delivered to chemistry majors, students had a significant gain in their ability to apply the concepts of electroosmosis and electrophoresis to predict analyte migration. Although this activity targets upper-level chemistry content, it can also be adapted for other laboratory experiences.

3.
Anal Chem ; 94(46): 16151-16159, 2022 11 22.
Artículo en Inglés | MEDLINE | ID: mdl-36343965

RESUMEN

Neuraminidase inhibitors modulate infections that involve sialic acids, making quantitative analyses of this inhibitory effect important for selecting and designing potential therapeutics. An automated nanogel capillary electrophoresis system is developed that integrates a 5 nL enzyme inhibition reaction in line with a 5 min separation-based assay of the enzymatic product to quantify inhibition as the half maximal inhibitory concentration (IC50) and inhibitor constant (Ki). A neuraminidase enzyme from Clostridium perfringens is non-covalently immobilized in a thermally tunable nanogel positioned in the thermally controlled region of the capillary by increasing the capillary temperature to 37 °C. Aqueous inhibitor solutions are loaded into the capillary during the nanogel patterning step to surround the enzyme zone. The capillary electrophoresis separation provides a means to distinguish the de-sialylated product, enabling the use of sialyllactose which contains the trisaccharide motif observed on serine/threonine-linked (O-linked) glycans. A universal nanogel patterning scheme is developed that does not require pre-mixing of enzymes with inhibitors when an automated capillary electrophoresis instrument is used, thus reducing the consumption of enzymes and enabling adaption of the method to different inhibitors. The universal approach is successfully applied to two classical neuraminidase inhibitors with different electrophoretic mobilities. The IC50 and Ki values obtained for N-acetyl-2,3-dehydro-2-deoxyneuraminic acid (DANA) are 13 ± 3 and 5.0 ± 0.9 µM, respectively, and 28 ± 3 and 11 ± 1 µM, respectively, for Siastatin B. These values agree with literature reports and reflect the weaker inhibition anticipated for Siastatin B in comparison to DANA.


Asunto(s)
Electroforesis Capilar , Neuraminidasa , Nanogeles , Electroforesis Capilar/métodos , Polietileneimina , Inhibidores Enzimáticos
4.
Anal Chem ; 94(32): 11329-11336, 2022 08 16.
Artículo en Inglés | MEDLINE | ID: mdl-35913997

RESUMEN

Coupling capillary electrophoresis (CE) to mass spectrometry (MS) is a powerful strategy to leverage a high separation efficiency with structural identification. Traditional CE-MS interfacing relies upon voltage to drive this process. Additionally, sheathless interfacing requires that the electrophoresis generates a sufficient volumetric flow to sustain the ionization process. Vibrating sharp-edge spray ionization (VSSI) is a new method to interface capillary electrophoresis to mass analyzers. In contrast to traditional interfacing, VSSI is voltage-free, making it straightforward for CE and MS. New nanoflow sheath CE-VSSI-MS is introduced in this work to reduce the reliance on the separation flow rate to facilitate the transfer of analyte to the MS. The nanoflow sheath VSSI spray ionization functions from 400 to 900 nL/min. Using the new nanoflow sheath reported here, volumetric flow rate through the separation capillary is less critical, allowing the use of a small (i.e., 20 to 25 µm) inner diameter separation capillary and enabling the use of higher separation voltages and faster analysis. Moreover, the use of a nanoflow sheath enables greater flexibility in the separation conditions. The nanoflow sheath is operated using aqueous solutions in the background electrolyte and in the sheath, demonstrating the separation can be performed under normal and reversed polarity in the presence or absence of electroosmotic flow. This includes the use of a wider pH range as well. The versatility of nanoflow sheath CE-VSSI-MS is demonstrated by separating cationic, anionic, and zwitterionic molecules under a variety of separation conditions. The detection sensitivity observed with nanoflow sheath CE-VSSI-MS is comparable to that obtained with sheathless CE-VSSI-MS as well as CE-MS separations with electrospray ionization interfacing. A bare fused silica capillary is used to separate cationic ß-blockers with a near-neutral background electrolyte at concentrations ranging from 1.0 nM to 1.0 µM. Under acidic conditions, 13 amino acids are separated with normal polarity at a concentration ranging from 0.25 to 5 µM. Finally, separations of anionic compounds are demonstrated using reversed polarity under conditions of suppressed electroosmotic flow through the use of a semipermanent surface coating. With a near-neutral separation electrolyte, anionic nonsteroidal anti-inflammatory drugs are detected over a concentration range of 0.1 to 5.0 µM.


Asunto(s)
Electroforesis Capilar , Espectrometría de Masa por Ionización de Electrospray , Aniones , Cationes , Electroósmosis , Electroforesis Capilar/métodos , Espectrometría de Masa por Ionización de Electrospray/métodos
5.
Anal Bioanal Chem ; 414(1): 713-720, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34693472

RESUMEN

The topology of DNA is a critical quality attribute for plasmid-based pharmaceuticals, making quantification of trace levels of plasmid topoisomers an important analytical priority. An automated and cost-effective method based on capillary gel electrophoresis laser-induced fluorescence detection is described. The method outlined in this report is significant because it is easily implemented by any laboratory for which routine analyses of plasmid topology are critical for the development of new plasmid-based therapies as well as for quality control of gene therapies utilizing supercoiled DNA. Detection of topoisomers was achieved by incorporating ethidium bromide in the separation medium. The detector response was improved by 3 orders of magnitude by utilizing a 605-nm optical filter with a 15-nm bandwidth. Separations of linear, open circle, supercoiled, and multimer DNA plasmids ranging from 4.2 to 10.5 kbp were accomplished in under 6 min using an unmodified fused silica capillary (50-µm internal diameter). The background electrolyte was comprised of 0.5% gel, which was hydroxypropylmethyl cellulose, 1 mM ethylenediaminetetraacetic acid, and 50 mM N-(2-acetamido)-2-aminoethanesulfonic acid (pH of 6.25). The separations, which balanced the bulk electroosmotic flow, the electrophoretic mobility of the DNA, and gel sieving were dependent upon the pH of the electrolyte and the gel concentration. Reproducibility was dependent upon the procedure used to prepare the gel as well as other factors including the ethidium bromide concentration and capillary conditioning. A single unmodified capillary operated for more than 150 runs had an across-day migration time precision of 1% relative standard deviation and percent area precision of 10% relative standard deviation.


Asunto(s)
Capilares , Dióxido de Silicio , Capilares/química , ADN/genética , Electroforesis Capilar/métodos , Rayos Láser , Reproducibilidad de los Resultados
6.
J Chem Educ ; 99(10): 3590-3594, 2022 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-36277356

RESUMEN

A laboratory activity was developed to teach freezing point depression and colligative properties to introductory-level chemistry students. The laboratory uses food-grade reagents and is delivered in two units that can be taught in a single 2 hour session or two separate sessions. The total cost of the consumables is 1 USD. In the first part of this two-part activity, students perform measurements on the properties of five salt solutions to better know and understand freezing point depression. In the second part of the activity, students apply their knowledge and understanding of freezing point depression to make ice cream. The ice-cream-making experiment is delivered as a group activity to encourage reflection. Centering this experiment on ice cream allows students to connect properties described in chemistry to everyday life. The solutions used in the experiment are reusable and nonhazardous. The experiment can be implemented in a classroom, in a teaching laboratory, or at home.

7.
Anal Chem ; 93(34): 11843-11851, 2021 08 31.
Artículo en Inglés | MEDLINE | ID: mdl-34410102

RESUMEN

A thermally reversible nanogel is used in capillary electrophoresis to create discrete regions for a galactosyltransferase reaction and separation. The ß1-4 galactosyltransferase enzyme, donor, and co-factor were patterned in the capillary. The substrate was driven through these zones and converted to galactosylated products, which were separated and identified. Using this capillary electrophoresis method, the degree of glycosylation was discernible for a pentasaccharide and for biantennary N-glycans. With the ability to distinguish between reaction products for which either one or two galactose residues were transferred, the capillary nanogel electrophoresis system was used to determine the Michaelis-Menten value, KM. For the ß1-4 galactosyltransferase, the KM value obtained for a pentasaccharide substrate was 1.23 ± 0.08 mM. Once KM was established, the enzyme/substrate ratio was evaluated to add a single galactose residue or to fully galactosylate a biantennary N-glycan. Additionally, capillary nanogel electrophoresis was adapted to transfer galactose residues to protein. The applicability of the method for real-time online modification of whole protein was demonstrated with the Herceptin glycoprotein. Complete retardation by Erythrina cristagalli lectin after enzymatic modification confirmed the addition of galactose residues to the Herceptin. This demonstrated the potential of the method to be used for online modification of other glycoproteins.


Asunto(s)
Galactosa , Polisacáridos , Electroforesis Capilar , Galactosiltransferasas , Glicoproteínas , Nanogeles
8.
Anal Chem ; 93(3): 1537-1543, 2021 01 26.
Artículo en Inglés | MEDLINE | ID: mdl-33382256

RESUMEN

Protein sieving, which is a fundamental tool in the biotechnology field, can be automated using capillary gel electrophoresis. The high-viscosity and biocompatible linear gels required for capillary sieving must be replaced for each run using high pressures. Thermally responsive gels are easier to renew in the capillary as they can be repetitively switched between low- and high-viscosity solutions. A thermally responsive sieving gel was recently demonstrated to separate DNA, which is a larger biomolecule than proteins. This material required no synthesis as it was self-assembled from common phospholipids. Nanogels composed of dimyristoyl-sn-glycero-2-phosphocholine and 1,2-dihexanoyl-sn-glycero-3-phosphocholine exhibit thermally reversible viscosity within a 10 °C temperature change, forming a sieving matrix above 24 °C. Additionally, these nanogels are nondenaturing and have been demonstrated to preserve the activity of enzymes. In this report, a phospholipid nanogel is used for the first time for capillary gel electrophoresis separations of proteins. The mobilities in buffer and nanogel demonstrated that 20-30% nanogel supports sieving of proteins ranging from 20 to 80 kDa. Capillary separations based on sieving rather than electrophoresis had similar precision in both area and migration time as well as similar separation efficiencies. However, the migration time increased with gel concentration. The nanogel was used for the analysis of proteins in human serum. Proteins in the sample were more effectively resolved and quantified with capillary sieving compared to free-solution capillary electrophoresis. This allowed for accurate quantification.


Asunto(s)
Proteínas Sanguíneas/análisis , Nanogeles/química , Electroforesis Capilar , Humanos , Temperatura
9.
Anal Chem ; 92(4): 3006-3013, 2020 02 18.
Artículo en Inglés | MEDLINE | ID: mdl-31971372

RESUMEN

Capillary electrophoresis-mass spectrometry is a powerful technique for high-throughput and high efficiency separations combined with structural identification. Electrospray ionization is the primary interface used to couple capillary electrophoresis to mass analyzers; however, improved designs continue to be reported. A new interfacing method based on vibrating sharp-edge spray ionization is presented in this work to overcome the challenges of decoupling applied voltages and to enhance the compatibility with separations performed at near-neutral pH. The versatility and ease of use of this ionization source is demonstrated using ß-blockers, peptides, and proteins. The cationic ß-blocker pindolol was injected electrokinetically, and detected at concentrations ranging from 10 nM to 5 µM, with an estimated detection limit of 2 nM. The vibrating sharp-edge spray ionization functions with flow rates from 70 to 200 nL/min and did not perturb the capillary electrophoresis separation electroosmotic flow as evidenced by the observation that most migration times differed less than 7% (n = 3) across a lab-built system interfaced to mass spectrometry and a commercial system that utilizes absorbance detection. For cationic beta-blockers the theoretical plates achieved in the capillary electrophoresis-mass spectrometry setup were 80%-95% of that observed with a commercial capillary electrophoresis-UV absorbance detection system.


Asunto(s)
Electroósmosis , Pindolol/análisis , Electroforesis Capilar/instrumentación , Estructura Molecular , Espectrometría de Masa por Ionización de Electrospray/instrumentación
10.
Anal Chem ; 92(1): 1518-1524, 2020 01 07.
Artículo en Inglés | MEDLINE | ID: mdl-31829566

RESUMEN

Sialylation and sialic acid linkage in N-glycans are markers of disease but are analytically challenging to quantify. A capillary electrophoresis method is reported that integrates a unique combination of enzymes and lectins to modify sialylated N-glycans in real time in the capillary so that N-glycan structures containing α2-6-linked sialic acid are easily separated, detected, and quantified. In this study, N-glycans were sequentially cleaved by enzymes at the head of the separation capillary so that the presence of α2-6-linked sialic acids corresponded to a shift in the analyte migration time in a manner that enabled interpretation of the N-glycan structure. Following injection, only afucosylated N-glycan structures were passed through enzyme zones that contained α2-3 sialidase, followed by ß1-3,4 galactosidase, which cleaved any terminal α2-3-linked sialic acid and underlying galactose yielding a terminal N-acetyl glucosamine. With this treatment complete, a third zone of α2-3,6,8 sialidase converted the remaining α2-6-linked sialic acid to terminal galactose. With these enzyme processing steps the α2-6-linked sialic acid residues on an N-glycan correlated directly to the number of terminal galactose residues that remained. The number of terminal galactose residues could be interpreted as a stepwise decrease in the migration time. Complex N-glycans from α-1-acid glycoprotein were analyzed using this approach, revealing that a limited number of α2-6-linked sialic acids were present with biantennary, triantennary, and tetraantennary N-glycans of α-1-acid glycoprotein generally containing 0 or 1 α2-6-linked sialic acid.


Asunto(s)
Ácido N-Acetilneuramínico/análisis , Nanogeles/química , Polisacáridos/análisis , Electroforesis Capilar , Humanos , Estructura Molecular
11.
Chem Rev ; 118(17): 7867-7885, 2018 09 12.
Artículo en Inglés | MEDLINE | ID: mdl-29528644

RESUMEN

Capillary electrophoresis has emerged as a powerful approach for carbohydrate analyses since 2014. The method provides high resolution capable of separating carbohydrates by charge-to-size ratio. Principle applications are heavily focused on N-glycans, which are highly relevant to biological therapeutics and biomarker research. Advances in techniques used for N-glycan structural identification include migration time indexing and exoglycosidase and lectin profiling, as well as mass spectrometry. Capillary electrophoresis methods have been developed that are capable of separating glycans with the same monosaccharide sequence but different positional isomers, as well as determining whether monosaccharides composing a glycan are alpha or beta linked. Significant applications of capillary electrophoresis to the analyses of N-glycans in biomarker discovery and biological therapeutics are emphasized with a brief discussion included on carbohydrate analyses of glycosaminoglycans and mono-, di-, and oligosaccharides relevant to food and plant products. Innovative, emerging techniques in the field are highlighted and the future direction of the technology is projected based on the significant contributions of capillary electrophoresis to glycoscience from 2014 to the present as discussed in this review.


Asunto(s)
Electroforesis Capilar/métodos , Polisacáridos/química , Conformación de Carbohidratos , Ensayos Analíticos de Alto Rendimiento , Monosacáridos/química , Oligosacáridos/química , Pirenos/química , Coloración y Etiquetado
12.
Anal Chem ; 91(2): 1375-1383, 2019 01 15.
Artículo en Inglés | MEDLINE | ID: mdl-30525457

RESUMEN

Glycosylated human IgG contains fucosylated biantennary N-glycans with different modifications including N-acetylglucosamine, which bisects the mannose core. Although only a limited number of IgG N-glycan structures are possible, human IgG N-glycans are predominantly biantennary and fucosylated and contain varying levels of α2-6-linked sialic acid, galactose, and bisected N-acetylglucosamine. Monitoring the relative abundance of bisecting N-acetylglucosamine is relevant to physiological processes. A rapid, inexpensive, and automated method is used to successfully profile N-linked IgG glycans and is suitable to distinguish differences in bisection, galactosylation, and sialylation in N-glycans derived from different sources of human IgG. The separation is facilitated with self-assembled nanogels that also contain a single stationary zone of lectin. When the lectin specificity matches the N-glycan, the peak disappears from the electropherogram, identifying the N-glycan structure. The nanogel electrophoresis generates separation efficiencies of 500 000 plates and resolves the positional isomers of monogalactosylated biantennary N-glycan and the monogalactosylated bisected N-glycan. Aleuria aurantia lectin, Erythrina cristagalli lectin (ECL), Sambucus nigra lectin, and Phaseolus vulgaris Erythroagglutinin (PHA-E) are used to identify fucose, galactose, α2-6-linked sialic acid, and bisected N-acetylglucosamine, respectively. Although PHA-E lectin has a strong binding affinity for bisected N-glycans that also contain a terminal galactose on the α1-6-linked mannose branch, this lectin has lower affinity for N-glycans containing terminal galactose and for agalactosylated bisected biantennary N-glycans. The lower affinity to these motifs is observed in the electropherograms as a change in peak width, which when used in conjunction with the results from the ECL lectin authenticates the composition of the agalactosylated bisected biantennary N-glycan. For runs performed at 17 °C, the precision in migration time and peak area was less than or equal to 0.08 and 4% relative standard deviation, respectively. The method is compatible with electrokinetic and hydrodynamic injections, with detection limits of 70 and 300 pM, respectively.


Asunto(s)
Electroforesis Capilar/métodos , Inmunoglobulina G/química , Nanogeles/química , Lectinas de Plantas/química , Polisacáridos/análisis , Ascomicetos/química , Erythrina/química , Humanos , Lectinas/química , Phaseolus/química , Polisacáridos/química , Proteínas Inactivadoras de Ribosomas/química , Sambucus nigra/química
14.
Methods ; 146: 93-106, 2018 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-29499329

RESUMEN

Capillary electrophoresis provides a rapid, cost-effective platform for enzyme and substrate characterization. The high resolution achievable by capillary electrophoresis enables the analysis of substrates and products that are indistinguishable by spectroscopic techniques alone, while the small volume requirement enables analysis of enzymes or substrates in limited supply. Furthermore, the compatibility of capillary electrophoresis with various detectors makes it suitable for KM determinations ranging from nanomolar to millimolar concentrations. Capillary electrophoresis fundamentals are discussed with an emphasis on the separation mechanisms relevant to evaluate sets of substrate and product that are charged, neutral, and even chiral. The basic principles of Michaelis-Menten determinations are reviewed and the process of translating capillary electrophoresis electropherograms into a Michaelis-Menten curve is outlined. The conditions that must be optimized in order to couple off-line and on-line enzyme reactions with capillary electrophoresis separations, such as incubation time, buffer pH and ionic strength, and temperature, are examined to provide insight into how the techniques can be best utilized. The application of capillary electrophoresis to quantify enzyme inhibition, in the form of KI or IC50 is detailed. The concept and implementation of the immobilized enzyme reactor is described as a means to increase enzyme stability and reusability, as well as a powerful tool for screening enzyme substrates and inhibitors. Emerging techniques focused on applying capillary electrophoresis as a rapid assay to obtain structural identification or sequence information about a substrate and in-line digestions of peptides and proteins coupled to mass spectrometry analyses are highlighted.


Asunto(s)
Electroforesis Capilar/métodos , Enzimas/metabolismo , Electroforesis Capilar/tendencias , Inhibidores Enzimáticos/química , Enzimas/química , Cinética
15.
Anal Bioanal Chem ; 410(24): 6041-6050, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30120497

RESUMEN

Nanotechnology is a broad field combining traditional scientific disciplines; however, analytical chemistry plays an important role in material design, synthesis, characterization, and application. This article emphasizes the uniqueness of nanotechnology and the importance of providing high-quality undergraduate research experiences to both attract and retain talented individuals to the field of nanotechnology. In response to this need to develop a strong and sustainable nanotechnology work force, strategies to create authentic research experiences are considered within the framework of an interdisciplinary nanotechnology environment at West Virginia University. The program, named NanoSAFE Research Experiences for Undergraduates (REU), embeds students in different departments at West Virginia University and in research laboratories within the National Institute of Occupational Safety and Health. A large number of participants have little or no prior research experience and a strong effort is made to recruit applicants from under-represented populations. Components designed to foster research proficiency include frequent reporting, a strong peer-network, and training for secondary mentors. Evidence, which includes student publications and assessment findings demonstrating self-efficacy, is discussed to substantiate the viability of the strategies used in the 2016-2018 program. Graphical abstract ᅟ.


Asunto(s)
Nanotecnología/educación , Química Analítica/educación , Humanos , Estudios Interdisciplinarios , Investigación , Estudiantes , Universidades , West Virginia
16.
Anal Chem ; 89(1): 929-936, 2017 01 03.
Artículo en Inglés | MEDLINE | ID: mdl-27936604

RESUMEN

Phospholipid nanogels enhance the stability and performance of the exoglycosidase enzyme neuraminidase and are used to create a fixed zone of enzyme within a capillary. With nanogels, there is no need to covalently immobilize the enzyme, as it is physically constrained. This enables rapid quantification of Michaelis-Menten constants (KM) for different substrates and ultimately provides a means to quantify the linkage (i.e., 2-3 versus 2-6) of sialic acids. The fixed zone of enzyme is inexpensive and easily positioned in the capillary to support electrophoresis mediated microanalysis using neuraminidase to analyze sialic acid linkages. To circumvent the limitations of diffusion during static incubation, the incubation period is reproducibly achieved by varying the number of forward and reverse passes the substrate makes through the stationary fixed zone using in-capillary electrophoretic mixing. A KM value of 3.3 ± 0.8 mM (Vmax, 2100 ± 200 µM/min) was obtained for 3'-sialyllactose labeled with 2-aminobenzoic acid using neuraminidase from Clostridium perfringens that cleaves sialic acid monomers with an α2-3,6,8,9 linkage, which is similar to values reported in the literature that required benchtop analyses. The enzyme cleaves the 2-3 linkage faster than the 2-6, and a KM of 2 ± 1 mM (Vmax, 400 ± 100 µM/min) was obtained for the 6'-sialyllactose substrate. An alternative neuraminidase selective for 2-3 sialic acid linkages generated a KM value of 3 ± 2 mM (Vmax, 900 ± 300 µM/min) for 3'-sialyllactose. With a knowledge of Vmax, the method was applied to a mixture of 2-3 and 2-6 sialyllactose as well as 2-3 and 2-6 sialylated triantennary glycan. Nanogel electrophoresis is an inexpensive, rapid, and simple alternative to current technologies used to distinguish the composition of 3' and 6' sialic acid linkages.


Asunto(s)
Ácido N-Acetilneuramínico/análisis , Ácido N-Acetilneuramínico/química , Nanopartículas , Neuraminidasa/química , Clostridium perfringens/enzimología , Electroforesis Capilar , Geles/química , Neuraminidasa/metabolismo
18.
Anal Bioanal Chem ; 407(23): 6923-38, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25935677

RESUMEN

This review of capillary electrophoresis methods for DNA analyses covers critical advances from 2009 to 2014, referencing 184 citations. Separation mechanisms based on free-zone capillary electrophoresis, Ogston sieving, and reptation are described. Two prevalent gel matrices for gel-facilitated sieving, which are linear polyacrylamide and polydimethylacrylamide, are compared in terms of performance, cost, viscosity, and passivation of electroosmotic flow. The role of capillary electrophoresis in the discovery, design, and characterization of DNA aptamers for molecular recognition is discussed. Expanding and emerging techniques in the field are also highlighted.


Asunto(s)
ADN/análisis , ADN/genética , Electroforesis Capilar/instrumentación , Electroforesis Capilar/métodos , Análisis de Secuencia de ADN/instrumentación , Análisis de Secuencia de ADN/métodos , Aptámeros de Nucleótidos/análisis , Aptámeros de Nucleótidos/síntesis química , Aptámeros de Nucleótidos/genética , ADN/química , Diseño de Fármacos
19.
Anal Bioanal Chem ; 407(23): 6985-93, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26041454

RESUMEN

Capillary electrophoresis and UV-visible absorbance detection are used with sample stacking to achieve detection limits ranging from 0.2 to 2 ng/mL (0.8 to 6 nM) for steroids. Stacking is accomplished using negatively charged cyclodextrin steroid-carrier molecules at a discrete pH interface between the reconstituted sample and the separation electrolyte. Steroids are then separated in under 5 min using capillary electrophoresis that incorporates secondary equilibria via sodium dodecyl sulfate and cyclodextrin. The effectiveness of the method for measurements of multiple steroids in limited sample volumes is demonstrated in individual female fish with total circulating blood volumes of 5 µL or less. Steroid recoveries from plasma following a sample processing method developed with commercial extraction cartridges range from 81 to 109 % for 17α,20ß-dihydroxy-pregn-4-en-3-one, testosterone, 11-ketotestosterone, estrone, 17ß-estradiol, and 17α-ethinyl estradiol. When applied to reproductively active female zebrafish, changes were detected in the levels of circulating steroids as a result of exposure to different solvents and 17ß-estradiol.


Asunto(s)
Electroforesis Capilar/métodos , Disruptores Endocrinos/sangre , Microquímica/métodos , Espectrofotometría Ultravioleta/métodos , Esteroides/sangre , Pez Cebra/sangre , Animales , Bioensayo/métodos , Nanotecnología/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
20.
Int J Mol Sci ; 15(8): 14332-47, 2014 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-25196435

RESUMEN

Widespread use of the chlorotriazine herbicide, atrazine, has led to serious environmental and human health consequences. Current methods of detecting atrazine contamination are neither rapid nor cost-effective. In this work, atrazine-specific single-stranded DNA (ssDNA) molecular recognition elements (MRE) were isolated. We utilized a stringent Systematic Evolution of Ligands by Exponential Enrichment (SELEX) methodology that placed the greatest emphasis on what the MRE should not bind to. After twelve rounds of SELEX, an atrazine-specific MRE with high affinity was obtained. The equilibrium dissociation constant (Kd) of the ssDNA sequence is 0.62 ± 0.21 nM. It also has significant selectivity for atrazine over atrazine metabolites and other pesticides found in environmentally similar locations and concentrations. Furthermore, we have detected environmentally relevant atrazine concentrations in river water using this MRE. The strong affinity and selectivity of the selected atrazine-specific ssDNA validated the stringent SELEX methodology and identified a MRE that will be useful for rapid atrazine detection in environmental samples.


Asunto(s)
Atrazina/química , ADN de Cadena Simple/química , Técnicas In Vitro
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA