Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Chromatogr A ; 1189(1-2): 254-65, 2008 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-17977551

RESUMEN

Properties-retention studies were undertaken on a test library of sulfonamides using supercritical fluid chromatography with CO(2)-MeOH mobile phases (in the presence or absence of additive) and a 2-ethyl-pyridyl column. Taking a restricted range of retention ratios, k (10.98). From these relationships, the different retention characteristics of the analytes were calculated. Literature studies of quantitative structure-retention relationships (QSRR) showed that these characteristics can be correlated with simple molecular descriptors to derive equations predicting the retention behaviour of new compounds. Measured retention characteristics were found to correlate with total dipole moment, mu, molecular surface area, A, and the electronic charge on the most negatively charged atom, delta(min). The correlation of chromatographic measurements with calculated molecular descriptors may allow the prediction of the retention behaviour for an unknown compound provided its properties are known.


Asunto(s)
Cromatografía con Fluido Supercrítico/métodos , Sulfonamidas/análisis , Algoritmos , Estructura Molecular , Análisis de Regresión , Sulfonamidas/química
2.
Rapid Commun Mass Spectrom ; 22(22): 3673-82, 2008 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-18956437

RESUMEN

Supercritical fluid chromatography (SFC) is fast becoming a technique of choice for the analysis of a wide range of compounds and has been found to be complementary to high-performance liquid chromatography (HPLC). The combination of SFC and mass spectrometry (MS) affords a very useful tool in the separation and analysis of compounds. In this study the ionisation of samples in the absence of an applied electrospray voltage has been observed when using SFC/MS, with some compounds showing increased sensitivity when all ionisation source high voltage (HV) is removed. In an attempt to understand the mechanism of ionisation, a series of test compounds were analysed using standard electrospray ionisation (ESI) and atmospheric pressure chemical ionisation (APCI) source configurations and also different API source designs. In both cases, data were acquired with the applied high voltage on (normal conditions) or with the high voltage off, i.e. no voltage spray (novo-spray). The standards were analysed with a range of pressure and modifier percentage conditions. To understand the nature of the ionisation process observed, this was compared with three established liquid-to-gas ionisation mechanisms. These were thermospray (TSP), charge residue model (CRM) of ESI and sonic spray ionisation (SSI). Experiments were undertaken in an attempt to explain this ionisation phenomenon and quantify any observed change in sensitivity. The most important point to note is that enhanced ionisation was observed under novo-spray conditions in a SFC/MS configuration, which in certain cases provides a lowering in the overall limit of detection (LOD).


Asunto(s)
Cromatografía con Fluido Supercrítico/métodos , Iones/química , Espectrometría de Masa por Ionización de Electrospray/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA