1.
Radiologe ; 55(8): 663-72, 2015 Aug.
Artículo en Alemán | MEDLINE | ID: mdl-26220128

RESUMEN

The radiation exposure of an unborn child should be principally avoided, whenever it is medically reasonably possible; therefore, the identification of pregnant patients is the first and the most important step in radiation protection of the unborn child. However, in cases of emergency saving the life of the patient has a higher priority than the radiation protection of the unborn child. In this review article, we present a longitudinal section through the national and international literature and guidelines as a basis for radiological management of a (possibly) pregnant patient. We also list some radiological procedures recommended in the literature for a series of maternal indications considering the contraindications of each method during pregnancy and radiation protection of the unborn child.


Asunto(s)
Imagen por Resonancia Magnética/normas , Guías de Práctica Clínica como Asunto , Complicaciones del Embarazo/diagnóstico por imagen , Traumatismos por Radiación/congénito , Traumatismos por Radiación/prevención & control , Protección Radiológica/normas , Femenino , Alemania , Humanos , Imagen por Resonancia Magnética/efectos adversos , Embarazo , Complicaciones del Embarazo/cirugía , Dosis de Radiación , Traumatismos por Radiación/etiología , Radiografía , Radiometría/normas
2.
Eur Radiol ; 22(1): 205-10, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21874360

RESUMEN

OBJECTIVE: To test a digital imaging X-ray device based on the direct capture of X-ray photons with pixel detectors, which are coupled with photon-counting readout electronics. METHODS: The chip consists of a matrix of 256 × 256 pixels with a pixel pitch of 55 µm. A monolithic image of 11.2 cm × 7 cm was obtained by the consecutive displacement approach. Images of embalmed anatomical specimens of eight human hands were obtained at four different dose levels (skin dose 2.4, 6, 12, 25 µGy) with the new detector, as well as with a flat-panel detector. RESULTS: The overall rating scores for the evaluated anatomical regions ranged from 5.23 at the lowest dose level, 6.32 at approximately 6 µGy, 6.70 at 12 µGy, to 6.99 at the highest dose level with the photon-counting system. The corresponding rating scores for the flat-panel detector were 3.84, 5.39, 6.64, and 7.34. When images obtained at the same dose were compared, the new system outperformed the conventional DR system at the two lowest dose levels. At the higher dose levels, there were no significant differences between the two systems. CONCLUSION: The photon-counting detector has great potential to obtain musculoskeletal images of excellent quality at very low dose levels.


Asunto(s)
Mano/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/instrumentación , Enfermedades Musculoesqueléticas/diagnóstico por imagen , Fotones , Intensificación de Imagen Radiográfica/instrumentación , Cadáver , Diseño de Equipo , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Dosis de Radiación , Intensificación de Imagen Radiográfica/métodos
3.
J Anim Physiol Anim Nutr (Berl) ; 96(4): 660-70, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21762428

RESUMEN

Conclusions from narrative qualitative reviews on differences in total tract digestibilities between goats and sheep did not account for variability among studies. Therefore meta-analytic techniques were used to describe the magnitude of these differences with numerical values. A unitless effect size (Hedges' g) was applied within studies to measure differences in digestibilities of dry matter (DM; 104 comparisons), organic matter (OM; 93 comparisons), crude protein (CP; 85 comparisons), neutral detergent fibre (NDF; 74 comparisons), acid detergent fibre (ADF; 59 comparisons), cellulose (24 comparisons), hemicellulose (18 comparisons) and gross energy (GE; 29 comparisons). The absence and inability to describe independent factors which contributed to variation among studies necessitated the use of frequentist random effects and hierarchical Bayesian models in the calculation of summary statistics across studies. Digestibilities of DM, OM, CP, NDF, ADF and hemicellulose were higher (p < 0.05) in goats than sheep when all-forage diets were fed. When concentrates were included in the diets, there were no such differences. Differences between goats and sheep in DM intake were found to be non-significant. Differences in nutrient digestibilities of forages as sole feed implies that species-specific values have to be used in feed formulation and feeding strategies. However, caution is needed when extrapolating results from stall-feeding, which is how digestibility data are usually measured, to grazing conditions.


Asunto(s)
Fenómenos Fisiológicos Nutricionales de los Animales , Digestión/fisiología , Tracto Gastrointestinal/fisiología , Cabras/fisiología , Ovinos/fisiología , Alimentación Animal/análisis , Animales , Teorema de Bayes , Fibras de la Dieta , Proteínas en la Dieta , Metabolismo Energético , Especificidad de la Especie
4.
Phys Med ; 82: 255-265, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33677387

RESUMEN

Optimization of imaging examinations is a key requirement of both the International and European Basic Safety Standards, and the focus of much international activity. Although methodologies are well established in principle, there continues to be a variety of practical issues both in collecting and interpreting dose and image quality data and in making successful interventions to optimize exposures. A Coordinated Research Project, involving institutes from ten different countries, was established by the IAEA to assess the efficacy of recommended optimization methodologies in the field of paediatric radiology and to derive practical guidance on their implementation. The steps followed in this process were identification of the imaging process to be investigated (abdomen and chest x-rays, micturating cysto-urethrograms, and brain & thorax CT scans); collection of dose and image quality data; evaluation and comparison of the data between institutes and to standards; identification and implementation of interventions for optimization; and re-evaluation of dose and image quality parameters. The project succeeded both in achieving effective interventions for optimization of specific imaging tasks in individual institutes and in identifying key issues with potential to handicap this process. The main area in which problems were encountered was in the collation of reliable dose and image quality data. The reasons for this were explored and a series of recommendations have been made, summarized into 'ten practical tips' for optimization to assist institutes, particularly those in the early stages of addressing optimization issues.


Asunto(s)
Radiología , Niño , Humanos , Imagen Multimodal , Dosis de Radiación , Radiografía , Proyectos de Investigación
5.
J Dairy Sci ; 93(8): 3746-54, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20655444

RESUMEN

Research studies presented inconsistent results on the effects and action of choline in dairy cow diets. A meta-analysis was conducted to quantify the effects of dietary rumen-protected choline on production characteristics of dairy cows. Dry matter intake (kg/d), milk yield (kg/d), milk fat (% and kg/d), and milk protein (% and kg/d) were evaluated as dependent variables in models. The number of treatment means varied from 20 obtained in 7 studies for milk fat and protein contents to 34 from 11 studies (12 experiments) for milk yield. Accounting for experiment as a random effect, DMI, milk yield, milk protein content, and milk protein yield could adequately be related to levels of dietary rumen-protected choline chloride by a logistic model. Marginal responses in milk yield decreased from 131.5 to 0.037 g of milk/g of dietary rumen-protected choline chloride when supplementation increased from 6 to 50 g/d. From estimated values for the metabolizable Met supplied by diets, it appears that dietary rumen-protected choline chloride functions as a methyl donor to spare Met for milk protein synthesis. However, more accurate input data on Met status of diets are needed to confirm this. Within the range of 6 to 50 g/d of rumen-protected choline chloride, milk fat content decreased linearly at a rate of 0.00339% for a 1g/d increase in dietary rumen-protected choline chloride. This illustrates that dietary rumen-protected choline chloride has no effect on milk fat content. Numerous physiological and dietary factors probably related to responses obtained with dietary rumen-protected choline supplementation, and the precise mechanism of choline action in the lactating dairy cow warrants further investigation.


Asunto(s)
Bovinos/fisiología , Colina/farmacología , Suplementos Dietéticos , Lactancia/efectos de los fármacos , Leche/metabolismo , Alimentación Animal , Animales , Femenino , Lípidos/análisis , Leche/química , Proteínas de la Leche/análisis , Rumen
6.
Scr Med (Brno) ; 80(4): 179-188, 2007 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-19436777

RESUMEN

The relationship between age and circadian blood pressure (BP) variation was the aim of the present study. One hundred and eighty-seven subjects (130 males, 57 females), 20-77 years old, were recruited for seven-day BP monitoring. Colin medical instruments (Komaki, Japan) were used for ambulatory BP monitoring (oscillation method, 30-minute interval between measurements). A sinusoidal curve was fitted (minimum square method) and the mean value and amplitude of the curve (double amplitude corresponds to the night-day difference) were evaluated on every day of monitoring. The average 7-day values of the mean (M) and of double amplitude (2A) for systolic BP (SBP), diastolic BP (DBP), and heart rate (HR) were determined in each subject. The mean values of M (+/-SD) for the whole group were: SBP- 127+/-8, DBP - 79+/-6 mmHg, HR - 70+/-6 bpm; of 2A: SBP - 21+/-7, DBP - 15+/-5 mmHg, HR - 15+/-6 bpm. A linear relationship between M of SBP and age (r=0.341, p< 0.001) and DBP and age (r=0.384, p<0.001) was found (difference between 20 and 77 years: SBP - 16, DBP - 12 mmHg). 2A of SBP and DBP was increasing with age up to 35 years, then the curve remained relatively flat up to 55 years (maximum at 45 years), and then it decreased again (difference between 45 and 77 years: SBP - 13mmHg, DBP - 12 mmHg). Heart rate M and 2A were age-independent. The mean values of SBP and DBP were increasing with age up to 75 years, but the night-day difference of SBP and DBP reached its maximum value at 45 years and then decreased.

7.
Scr Med (Brno) ; 80(4): 133-150, 2007 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-19710947

RESUMEN

The mapping of time structures, chronomes, constitutes an endeavor spawned by chronobiology: chronomics. This cartography in time shows signatures on the surface of the earth, cycles, also accumulating in life on the earth's surface. We append a glossary of these and other cycles, the names being coined in the light of approximate cycle length. These findings are transdisciplinary, in view of their broad representation and critical importance in the biosphere. Suggestions of mechanisms are derived from an analytical statistical documentation of characteristics with superposed epochs and superposed cycles and other "remove-and-replace" approaches. These approaches use the spontaneously changing presence or absence of an environmental, cyclic or other factor for the study of any corresponding changes in the biosphere. We illustrate the indispensability of the mapping of rhythm characteristics in broader structures, chronomes, along several or all available different time scales. We present results from a cooperative cartography of about 10, about 20, and about 50-year rhythms in the context of a broad endeavor concerned with the Biosphere and the Cosmos, the BIOCOS project. The participants in this project are our co-authors worldwide, beyond Brno and Minneapolis; the studies of human blood pressure and heart rate around the clock and along the week may provide the evidence for those influences that Mendel sought in meteorology and climatology.

8.
Scr Med (Brno) ; 80(4): 157-166, 2007 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19122770

RESUMEN

BIOCOS, the project aimed at studying BIOlogical systems in their COSmos, has obtained a great deal of expertise in the fields of blood pressure (BP) and heart rate (HR) monitoring and of marker rhythmometry for the purposes of screening, diagnosis, treatment, and prognosis. Prolonging the monitoring reduces the uncertainty in the estimation of circadian parameters; the current recommendation of BIOCOS requires monitoring for at least 7 days. The BIOCOS approach consists of a parametric and a non-parametric analysis of the data, in which the results from the individual subject are being compared with gender- and age-specified reference values in health.Chronobiological designs can offer important new information regarding the optimization of treatment by timing its administration as a function of circadian and other rhythms.New technological developments are needed to close the loop between the monitoring of blood pressure and the administration of antihypertensive drugs.

9.
Biomed Pharmacother ; 59 Suppl 1: S152-7, 2005 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16275485

RESUMEN

Overswinging or CHAT (brief for Circadian Hyper-Amplitude-Tension), that is an excessive circadian variation in blood pressure (BP), has been associated with a large increase in cardiovascular disease risk, present even in the absence of an elevated BP itself. This usually asymptomatic condition is usually overlooked by current practice based on spot-checks, because to be diagnosed, measurements need to be taken around-the-clock, preferably for 7 days at the outset. Once diagnosed, however, a usual circadian BP pattern can be restored by means of certain non-pharmacologic or pharmacologic interventions timed appropriately. Thereby, it is possible to reduce the risk of cardiovascular morbidity and mortality, cerebral ischemic events and nephropathy in particular. For the preparation of guidelines regarding the diagnosis of BP disorders and for the institution of primary as well as secondary preventive measures, it is important to know what the incidence of CHAT is on a global basis. We found 191 cases of CHAT among 1602 mostly 7-day/24-h BP profiles, obtained from several centers in different countries participating in an ongoing project on the BIOsphere and the COSmos (BIOCOS). CHAT incidence is about the same between men and women, but it is diagnosed more often among patients with borderline hypertension or with glucose intolerance. It is also more common among MESOR-hypertensive than among MESOR-normotensive individuals. Priority should be given to the development of an unobtrusive and affordable device to automatically monitor BP and to analyze the data as-one-goes, so that cardiovascular disease risk can be prevented.


Asunto(s)
Presión Sanguínea/fisiología , Ritmo Circadiano/fisiología , Hipertensión/diagnóstico , Adulto , Femenino , Intolerancia a la Glucosa/complicaciones , Frecuencia Cardíaca/fisiología , Humanos , Hipertensión/epidemiología , Japón/epidemiología , Masculino , Medición de Riesgo , Población Rural , Accidente Cerebrovascular/epidemiología , Población Urbana
10.
Scr Med (Brno) ; 78(2): 107-114, 2005 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-19424514

RESUMEN

Putative circadecadal modulations of a circannual variation in diastolic blood pressure are explored in a still accumulating 35 year record of self-measurements by a clinically healthy man. Analyses of monthly means by gliding spectra, one-way analysis of variance (ANOVA), and cosinor were carried out after removing data collected during travel across time zones or during illness. An about yearly change in diastolic blood pressure may or may not be detected with statistical significance by cosinor or ANOVA, apparently as a function of solar cycle number and/or stage. It appears to be, however, 1 year synchronized in the entire span analysed as a whole. A given variable such as diastolic blood pressure may be characterized by multifrequency rhythms that may intermodulate, so that findings in different stages of cycles with the lowest (e.g., circadecadal) frequency mapped may determine different outcomes in cycles with higher frequencies, such as circannuals.

11.
Phys Med Biol ; 60(9): N177-85, 2015 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-25879177

RESUMEN

For the technical quality assurance of breast cancer screening protocols several phantoms have been developed. Their dose sensitivity is a common topic often discussed in literature. The European protocol for the quality control of the physical and technical aspects of mammography screening suggests a contrast-detail phantom like the CDMAM phantom (Artinis Medical Systems, Elst, NL). The CDMAM 3.4 was tested with respect to its dose sensitivity and compared to other phantoms in a recent paper. The CDMAM 4.0 phantom provides other disc diameters and thicknesses adapted more closely to the image quality found in modern mammography systems. This motivates a comparison of the two generations using the same exposure parameters. We varied the time-current (mAs) within a range of clinically used values (40-140 mAs). All evaluations were done using automatic evaluation software provided by Artinis (for CDMAM 4.0) and the National Coordinating Centre for the Physics of Mammography, Guildford UK (CDMAM 3.4). We compared the relative dose sensitivity with respect to the different diameters and also computed the IQFinv parameter, which averages over the diameters as suggested in the manual for the phantom. The IQFinv parameter linearly depends on dose for both phantoms. The CDMAM 4.0 shows a more monotonous dependence on dose, the total variation of the threshold thicknesses as functions of the dose are significantly smaller than with the CDMAM 3.4. As the automatic evaluation shows rather different threshold thicknesses for the two phantoms, conversion factors for human to automatic readout have to be adapted.


Asunto(s)
Mamografía/instrumentación , Fantasmas de Imagen , Monitoreo de Radiación/instrumentación , Femenino , Humanos
12.
J Refract Surg ; 16(1): 23-31, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-10693616

RESUMEN

PURPOSE: To present the excimer laser corneal shaping system (ELCS-S), an add-on device to the Keratom, a commercially available 193-nm excimer laser built by Schwind. METHODS: The system is designed for the preparation of donor corneas under sterile conditions using the ultraviolet laser to offer greatest possible flexibility. Lenticules for planolamellar grafting and refractive epikeratoplasty, as well as donor buttons for penetrating keratoplasty can be computer-designed by the surgeon or technician and lathed with the system. RESULTS: Using the excimer laser corneal shaping system (ELCS-S) on human donor corneas, the central surface of the epikeratoplasty lenticule exhibited only narrow, flat concentric notches corresponding to the single lathing steps. Transmission electron microscopy revealed a damage zone of less than 0.3 microm in close approximation to the treated surface. The final thickness revealed a difference of less than +/-53 microm from the intended, initially programmed value. Ultrastructural studies showed the perpendicular stromal surface of the penetrating keratoplasty buttons to be smooth with minimal protrusion of Descemet's membrane. Endothelial injury was observed in a zone averaging between 40 and 100 microm adjacent to the cutting edge only. CONCLUSION: The excimer laser corneal shaping system (ELCS-S) allows a computer-controlled, surgeon-designed, sterile preparation of lamellar and penetrating corneal grafts with the use of the excimer laser. This could offer significant advantages in comparison to presently available systems for lamellar dissection and trephination.


Asunto(s)
Córnea/cirugía , Epiqueratofaquia/instrumentación , Queratoplastia Penetrante/instrumentación , Rayos Láser , Computadores , Córnea/patología , Córnea/ultraestructura , Topografía de la Córnea , Diseño de Equipo , Humanos , Microscopía Electrónica de Rastreo
13.
IEEE Trans Med Imaging ; 19(6): 616-20, 2000 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-11026464

RESUMEN

Development of complex software applications in image guided therapy (IGT) is often complicated by the fact that providing basic functionality for image processing and user interaction from a graphical user interfaces (GUI) requires considerable manpower for software development. We present a programming environment that combines the high-level image processing library AVW, in-house developed patient-to-image registration procedures, and an interface to position measurement hardware. A specific application can be developed by using Tcl/Tk, a simple platform-independent scripting language, for GUI development. This environment was applied to developing VISIT, a navigation system for computer-aided implant dentistry. VISIT is presented as a result of this paper. Parts of the development environment were made accessible to the public. Future work includes the implementation of video input for connecting ultrasound or fluoroscopy units. We conclude that our approach is well suited to accelerate the development of exploratory new applications of IGT.


Asunto(s)
Implantación Dental/métodos , Cuidados Intraoperatorios/métodos , Cuidados Preoperatorios/métodos , Programas Informáticos , Terapia Asistida por Computador/instrumentación , Humanos , Procesamiento de Imagen Asistido por Computador , Maxilares/diagnóstico por imagen , Procedimientos Quirúrgicos Ortognáticos , Tomografía Computarizada por Rayos X
14.
Phys Med Biol ; 47(3): N47-52, 2002 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-11848127

RESUMEN

A technique is presented for the production of polymer-based phantom materials from solid polymer powders and various compounds added to adjust x-ray attenuation. After mixing of the finely grained components, the samples are solidified by a sintering process under vacuum. The method described allows a flexible and inexpensive production of phantom materials. Photon attenuation and density can be adjusted by suitable choice of base polymers and additives to mimic a large range of soft tissues and water.


Asunto(s)
Biofisica/métodos , Fantasmas de Imagen , Polímeros/química , Fotones , Tomografía Computarizada por Rayos X/métodos , Vacio
15.
Phys Med Biol ; 47(16): 2917-23, 2002 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-12222855

RESUMEN

The temperature dependence of water equivalent phantom materials used in radiotherapy and diagnostic imaging has been investigated. Samples of phantom materials based on epoxy resin, polyethylene, a polystyrene-polypropylene mixture and commercially available phantom materials (Solid Water, Gammex RMI and Plastic Water, Nuclear Associates) were scanned at temperatures from 15 to 40 degrees C and HU values determined. At a reference temperature of 20 degrees C materials optimized for CT applications give HU values close to zero while the commercial materials show an offset of 119.77 HU (Plastic Water) and 27.69 HU (Solid Water). Temperature dependence was lowest for epoxy-based materials (EPX-W: -0.23 HU degrees C(-1); Solid Water: -0.25 HU degrees C(-1)) and highest for a polyethylene-based material (X0: -0.72 HU degrees C(-1)). A material based on a mixture of polystyrene and polypropylene (PSPPI: -0.27 HU degrees C(-1)) is comparable to epoxy-based materials and water (-0.29 HU degrees C(-1)).


Asunto(s)
Ensayo de Materiales/métodos , Minerales , Fantasmas de Imagen , Polímeros , Temperatura , Tomografía Computarizada por Rayos X/instrumentación , Agua , Materiales Biomiméticos , Control de Calidad , Reproducibilidad de los Resultados , Dispersión de Radiación , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos
16.
Phys Med Biol ; 47(16): 2907-16, 2002 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-12222854

RESUMEN

Using available data for photon attenuation and tissue composition, a computer code was developed for the optimization of the composition of phantom materials for diagnostic radiology. The code allows selection of attenuation data in a photon energy range from 1 to 150 keV and the choice of a suitable weight function in the energy interval chosen. For applications in CT imaging a weight function is available reflecting the contribution of the x-ray spectrum to the CT-signal. Several phantom materials for CT were optimized (body fat, trabecular bone, an average bone composition for C4 vertebrae and water) by varying the mineral components in a polymer base in order to adjust x-ray attenuation properties. Measurements with the water equivalent material (PSPP1) showed good agreement of calculated and measured HU values (AHU = 7.3 +/- 5.3 at 80 kVp and 4.0 +/- 2.7 at 140 kVp) and little variation of HU for tube voltages from 80 to 140 kVp. The method provides a fast and flexible means for obtaining optimized phantom materials for a large variety of tissue compositions and energy ranges.


Asunto(s)
Materiales Biomiméticos , Ensayo de Materiales/métodos , Fantasmas de Imagen , Polímeros , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos , Tejido Adiposo/diagnóstico por imagen , Huesos/diagnóstico por imagen , Vértebras Cervicales/diagnóstico por imagen , Diseño Asistido por Computadora , Diseño de Equipo/métodos , Humanos , Músculo Esquelético/diagnóstico por imagen , Control de Calidad , Reproducibilidad de los Resultados , Dispersión de Radiación , Sensibilidad y Especificidad , Agua
17.
Phys Med Biol ; 44(5): 1169-80, 1999 May.
Artículo en Inglés | MEDLINE | ID: mdl-10368010

RESUMEN

Area laser lathing and trephination of donor corneas is used to produce different types of grafts for human transplantation. 193 nm (ArF excimer) laser radiation is used, since this is known to give a non-thermal laser-tissue interaction with a minimal zone of tissue damage. To guarantee the highest degree of flexibility concerning the overall shape of the grafts as well as their thickness profiles, we use a small (compared with the area to be ablated) scanning laser spot. For area lathing of the tissue we have developed a new ablation algorithm (optimized scanning laser ablation, OSLA) that can be applied to lathe and perforate any tissue--with concave (as in this application), convex or plane surface geometry--where surface precision and smoothness are key issues. Using OSLA with the Excimer Laser Corneal Shaping System (a tool for in vitro fabrication of all kinds of corneal transplants like donor buttons for keratoplasty, lamellar grafts for epikeratoplasty and refractive lenticules) enabled us to produce all types of corneal grafts with very high precision. This is considered to be a major improvement towards the production of refractive lenticules.


Asunto(s)
Córnea/cirugía , Trasplante de Córnea , Terapia por Láser/métodos , Algoritmos , Fenómenos Biofísicos , Biofisica , Córnea/anatomía & histología , Estudios de Evaluación como Asunto , Humanos , Técnicas In Vitro , Terapia por Láser/instrumentación , Terapia por Láser/estadística & datos numéricos , Microscopía Electrónica de Rastreo
18.
Rofo ; 173(6): 558-62, 2001 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-11471298

RESUMEN

PURPOSE: An easily applicable method to estimate effective dose including in its definition the high radiosensitivity of the salivary glands from dental computed tomography is presented. Effective doses were calculated for a markedly dose reduced dental CT protocol as well as for standard settings. Data are compared with effective doses from the literature obtained with other modalities frequently used in dental care. METHODS: Conversion factors based on the weighted Computed Tomography Dose Index were derived from published data to calculate effective dose values for various CT exposure settings. RESULTS: Conversion factors determined can be used for clinically used kVp settings and prefiltrations. With reduced tube current an effective dose for a CT examination of the maxilla of 22 microSv can be achieved, which compares to values typically obtained with panoramic radiography (26 microSv). A CT scan of the mandible, respectively, gives 123 microSv comparable to a full mouth survey with intraoral films (150 microSv). CONCLUSION: For standard CT scan protocols of the mandible, effective doses exceed 600 microSv. Hence, low dose protocols for dental CT should be considered whenever feasable, especially for paediatric patients. If hard tissue diagnoses is performed, the potential of dose reduction is significant despite the higher image noise levels as readability is still adequate.


Asunto(s)
Radiografía Dental/estadística & datos numéricos , Radiometría/estadística & datos numéricos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Calibración , Humanos , Dosis de Radiación , Protección Radiológica , Glándulas Salivales/efectos de la radiación
19.
In Vivo ; 13(1): 67-76, 1999.
Artículo en Inglés | MEDLINE | ID: mdl-10218136

RESUMEN

Evidence here cited underlies resolutions at international meetings to initiate a chronobiology project for health improvement. This project demonstrates expeditiously the feasibility and the health benefits of incorporating chronomedical considerations in the diagnosis, treatment, and prevention of one (or a few closely related) vascular (and oncological) diseases, that have high awareness and importance in the public perspective. Thereby, chronomedicine should become a mainstream basic and applied speciality leading to continual improvement in national/international health status. Reference data obtained for health care can also serve to give a better understanding of the relationship between the terrestrial biosphere and cosmoi near and far.


Asunto(s)
Presión Sanguínea , Atención a la Salud , Frecuencia Cardíaca , Vuelo Espacial , Humanos , Investigación
20.
Med Eng Phys ; 23(9): 673-7, 2001 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-11755812

RESUMEN

Calibrated information on bone mineral density (BMD) may be used in dental implantology to measure "bone quality". It can be used to estimate the expected primary implant stability preoperatively and to guide the surgeon in selecting optimum implant types and operation techniques. Using a preoperative dental computed tomography (Dental-CT) scan, all of this information can be obtained without additional examinations and thus without additional X-ray exposure of the patient. In contrast to bone mineral determination in other body regions, local BMD values are important in the jaw bone. Therefore, a regimen where color-coded information on local bone mineralization is superimposed on Dental-CT images is proposed using the original CT volumes as well as reformatted views.


Asunto(s)
Densidad Ósea , Mandíbula/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Implantes Dentales , Humanos , Procesamiento de Imagen Asistido por Computador , Mandíbula/fisiología , Radiografía Dental