Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Hepatology ; 78(4): 1200-1208, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37080558

RESUMEN

BACKGROUND AND AIMS: The presence of at-risk NASH is associated with an increased risk of cirrhosis and complications. Therefore, noninvasive identification of at-risk NASH with an accurate biomarker is a critical need for pharmacologic therapy. We aim to explore the performance of several magnetic resonance (MR)-based imaging parameters in diagnosing at-risk NASH. APPROACH AND RESULTS: This prospective clinical trial (NCT02565446) includes 104 paired MR examinations and liver biopsies performed in patients with suspected or diagnosed NAFLD. Magnetic resonance elastography-assessed liver stiffness (LS), 6-point Dixon-derived proton density fat fraction (PDFF), and single-point saturation-recovery acquisition-calculated T1 relaxation time were explored. Among all predictors, LS showed the significantly highest accuracy in diagnosing at-risk NASH [AUC LS : 0.89 (0.82, 0.95), AUC PDFF : 0.70 (0.58, 0.81), AUC T1 : 0.72 (0.61, 0.82), z -score test z >1.96 for LS vs any of others]. The optimal cutoff value of LS to identify at-risk NASH patients was 3.3 kPa (sensitivity: 79%, specificity: 82%, negative predictive value: 91%), whereas the optimal cutoff value of T1 was 850 ms (sensitivity: 75%, specificity: 63%, and negative predictive value: 87%). PDFF had the highest performance in diagnosing NASH with any fibrosis stage [AUC PDFF : 0.82 (0.72, 0.91), AUC LS : 0.73 (0.63, 0.84), AUC T1 : 0.72 (0.61, 0.83), |z| <1.96 for all]. CONCLUSION: Magnetic resonance elastography-assessed LS alone outperformed PDFF, and T1 in identifying patients with at-risk NASH for therapeutic trials.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Enfermedad del Hígado Graso no Alcohólico , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Hígado/diagnóstico por imagen , Hígado/patología , Cirrosis Hepática/patología , Imagen por Resonancia Magnética/métodos , Enfermedad del Hígado Graso no Alcohólico/complicaciones , Protones , Estudios Prospectivos
2.
Radiographics ; 44(9): e240006, 2024 09.
Artículo en Inglés | MEDLINE | ID: mdl-39146204

RESUMEN

Hepatic sinusoids are highly specialized microcirculatory conduits within the hepatic lobules that facilitate liver functions. The sinusoids can be affected by various disorders, including sinusoidal dilatation, sinusoidal obstruction syndrome (SOS), sinusoidal cellular infiltration, perisinusoidal infiltration, and endothelial neoplasms, such as hemangioendothelioma and angiosarcoma. While these disorders, particularly SOS and neoplasms, can be life threatening, their clinical manifestation is often nonspecific. Patients may present with right upper quadrant pain, jaundice, hepatomegaly, ascites, splenomegaly, and unexplained weight gain, although the exact manifestation depends on the cause, severity, and duration of the disease. Ultimately, invasive tests may be necessary to establish the diagnosis. A comprehensive understanding of imaging manifestations of various sinusoidal disorders contributes to early diagnosis and can help radiologists detect subclinical disease. Additionally, specific imaging features may assist in identifying the cause of the disorder, leading to a more focused and quicker workup. For example, a mosaic pattern of enhancement of the liver parenchyma is suggestive of sinusoidal dilatation; peripheral and patchy reticular hypointensity of the liver parenchyma on hepatobiliary MR images is characteristic of SOS; and associated diffuse multiple hyperintensities on diffusion-weighted images may be specific for malignant sinusoidal cellular infiltration. The authors provide an overview of the pathogenesis, clinical features, and imaging appearances of various hepatic sinusoidal disorders, with a special emphasis on SOS. ©RSNA, 2024 Supplemental material is available for this article.


Asunto(s)
Enfermedad Veno-Oclusiva Hepática , Humanos , Enfermedad Veno-Oclusiva Hepática/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Diagnóstico Diferencial
3.
Artículo en Inglés | MEDLINE | ID: mdl-39146219

RESUMEN

OBJECTIVE: Pulmonary CT angiography (CTA) to detect pulmonary emboli can be performed using conventional dual-source CT with single-energy acquisition at high-pitch (high-pitch conventional CT), which minimizes motion artifacts, or routine-pitch, dual-energy acquisitions (routine-pitch conventional DECT), which maximize iodine signal. We compared iodine signal, radiation dose, and motion artifacts of pulmonary CTA between these conventional CT modalities and dual-source photon-counting detector CT with high-pitch, multienergy acquisitions (high-pitch photon-counting CT). METHODS: Consecutive clinically indicated pulmonary CTA exams were collected. CT number/noise was measured from the main to right lower lobe segmental pulmonary arteries using 120 kV threshold low, 120 kV, and mixed kV (0.6 linear blend) images. Three radiologists reviewed anonymized, randomized exams, rating them using a 4- or 5-point Likert scale (1 = worst, and 4/5 = best) for contrast enhancement in pulmonary arteries, motion artifacts in aortic root to subsegmental pulmonary arteries, lung image quality; pulmonary blood volume (PBV) map image quality (for multienergy or dual-energy exams), and contribution to reader confidence. RESULTS: One hundred fifty patients underwent high-pitch photon-counting CT (n = 50), high-pitch conventional CT (n = 50), and routine-pitch conventional DECT (n = 50). High-pitch photon-counting CT had lower radiation dose (CTDIvol: 8.1 ± 2.5 vs 9.6 ± 6.8 and 16.2 ± 8.5 mGy, respectively; P < 0.001), and routine-pitch conventional DECT had significantly less contrast (P < 0.009). CT number and CNR measurements were significantly greater at high-pitch photon-counting CT (P < 0.001). Across readers, high-pitch photon-counting CT demonstrated significantly higher subjective contrast enhancement in the pulmonary arteries compared to the other modalities (4.7 ± 0.6 vs 4.4 ± 0.7 vs 4.3 ± 0.7; P = 0.011) and lung image quality (3.4 ± 0.5 vs 3.1 ± 0.5 vs 3.1 ± 0.5; P = 0.013). High-pitch photon-counting CT and high-pitch conventional CT had fewer motion artifacts at all levels compared to DECT (P < 0.001). High-pitch photon-counting CT PBV maps had superior image quality (P < 0.001) and contribution to reader confidence (P < 0.001) compared to routine-pitch conventional DECT. CONCLUSION: High-pitch photon-counting pulmonary CTA demonstrated higher contrast in pulmonary arteries at lower radiation doses with improved lung image quality and fewer motion artifacts compared to high-pitch conventional CT and routine-pitch conventional dual-energy CT.

4.
Eur Radiol ; 32(2): 950-958, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34432123

RESUMEN

OBJECTIVES: To evaluate the relationship between biopsy-assessed hepatic steatosis, magnetic resonance imaging (MRI)-assessed proton density fat fraction (PDFF), and magnetic resonance elastography (MRE)-assessed liver stiffness measurement (LSM), in patients with or at risk for nonalcoholic fatty liver disease (NAFLD). METHODS: A retrospective study was performed, encompassing 256 patients who had a liver biopsy and MRI/MRE examination performed within 1 year. Clinical and laboratory data were retrieved from the electronic medical record. Hepatic steatosis and fibrosis were assessed by histopathological grading/staging. First, we analyzed the diagnostic performance of PDFF for distinguishing hepatic steatosis with the receiver operating characteristic analyses. Second, variables influencing LSM were screened with univariant analyses, then identified with multivariable linear regression. Finally, the potential relationship between PDFF and LSM was assessed with linear regression after adjustment for other influencing factors, in patients with diagnosed steatosis (PDFF ≥ 5%). RESULTS: The diagnostic accuracy of PDFF in distinguishing steatosis grades (S0-3) was above 0.82. No significant difference in LSM was found between patients with S1, S2, and S3 steatosis and between all steatosis grades after patients were grouped according to fibrosis stage. No statistically significant relationship was found between the LSM and PDFF (estimate = - 0.02, p = 0.065) after adjustment for fibrosis stage and age in patients with diagnosed steatosis (PDFF ≥ 5%). CONCLUSIONS: In patients with NAFLD, the severity of hepatic steatosis has no significant influence on the liver stiffness measurement with magnetic resonance elastography. KEY POINTS: • The MRI-based proton density fat fraction provides a quantitative assessment of hepatic steatosis with high accuracy. • No significant effect of hepatic steatosis on MRE-based liver stiffness measurement was found in patients with S1, S2, and S3 steatosis and between all steatosis grades after patients were grouped according to fibrosis stage. • After adjusting for fibrosis stage and age, there was no statistically significant relationship between liver stiffness and proton density fat fraction in patients with hepatic steatosis (p = 0.065).


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Enfermedad del Hígado Graso no Alcohólico , Humanos , Hígado/diagnóstico por imagen , Imagen por Resonancia Magnética , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Estudios Retrospectivos
5.
Clin Gastroenterol Hepatol ; 18(7): 1576-1583.e1, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-31683058

RESUMEN

BACKGROUND & AIMS: Single measurements of liver stiffness (LS) by magnetic resonance elastography (MRE) have been associated with outcomes of patients with primary sclerosing cholangitis (PSC), but the significance of changes in LS over time are unclear. We investigated associations between changes in LS measurement and progression of PSC. METHODS: We performed a retrospective review of 204 patients with patients who underwent 2 MREs at a single center between January 1, 2007 and December 31, 2018. We collected laboratory data and information on revised Mayo PSC risk and model for end-stage liver disease scores, the PSC risk estimate tool, and levels of aspartate transferase at the time of each MRE. The ΔLS/time was determined by the change in LS between the second MRE compared to the first MRE divided by the time between examinations. The primary endpoint was development of hepatic decompensation (ascites, variceal hemorrhage or hepatic encephalopathy). RESULTS: The median LS measurement was 2.72 kPa (interquartile range, 2.32-3.44 kPa) and the overall change in LS was 0.05 kPa/y. However, ΔLS/y was 10-fold higher in patients anticipated to have cirrhosis (0.31 kPa/y) compared to patients with no fibrosis (0.03 kPa/y). The median LS increased over time in patients who ultimately developed hepatic decompensation (0.60 kPa/y; interquartile range, 0.21-1.26 kPa/y) vs but remained static in patients who did not (reduction of 0.04/y; interquartile range, reductions of 0.26 to 0.17 kPa/y) (P < .001). The ΔLS/y value associated with the highest risk of hepatic decompensation was Δ0.34 kPa/y (hazard ratio [HR], 13.29; 95% CI, 0.23-33.78). After we adjusted for baseline LS and other risk factors, including serum level of alkaline phosphatase and the Mayo PSC risk score, ΔLS/y continued to be associated with hepatic decompensation. The optimal single LS cut-off associated with the hepatic decompensation was 4.32 kPa (HR, 60.41; 95% CI, 17.85-204.47). A combination of both cut-off values was associated with risk of hepatic decompensation (concordance score, 0.93; 95% CI, 0.88-0.98) CONCLUSIONS: A single LS measurement and changes in LS over time are independently associated with hepatic decompensation in patients with PSC. However, changes in LS occur slowly in patients without advanced fibrosis or hepatic decompensation.


Asunto(s)
Colangitis Esclerosante , Diagnóstico por Imagen de Elasticidad , Enfermedad Hepática en Estado Terminal , Várices Esofágicas y Gástricas , Colangitis Esclerosante/complicaciones , Colangitis Esclerosante/patología , Enfermedad Hepática en Estado Terminal/patología , Várices Esofágicas y Gástricas/etiología , Várices Esofágicas y Gástricas/patología , Hemorragia Gastrointestinal/patología , Humanos , Hígado/diagnóstico por imagen , Hígado/patología , Cirrosis Hepática/complicaciones , Cirrosis Hepática/patología , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
6.
Abdom Radiol (NY) ; 49(9): 3261-3273, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38769199

RESUMEN

Photon-counting detector CT (PCD-CT) is a new technology that has multiple diagnostic benefits including increased spatial resolution, iodine signal, and radiation dose efficiency, as well as multi-energy imaging capability, but which also has unique challenges in abdominal imaging. The purpose of this work is to summarize key features, technical parameters, and terms, which are common amongst current abdominopelvic PCD-CT systems and to propose standardized terminology (where none exists). In addition, user-selectable protocol parameters are highlighted to facilitate both scientific evaluation and early clinical adoption. Unique features of PCD-CT systems include photon-counting detectors themselves, energy thresholds and bins, and tube potential considerations for preserved spectral separation. Key parameters for describing different PCD-CT systems are reviewed and explained. While PCD-CT can generate multi-energy images like dual-energy CT, there are new types of images such as threshold images, energy bin images, and special spectral images. The standardized terms and concepts herein build upon prior interdisciplinary consensus and have been endorsed by the newly created Society of Abdominal Radiology Photon-counting CT Emerging Technology Commission.


Asunto(s)
Fotones , Radiografía Abdominal , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Radiografía Abdominal/métodos , Terminología como Asunto , Dosis de Radiación , Pelvis/diagnóstico por imagen
7.
Br J Radiol ; 97(1153): 93-97, 2024 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-38263843

RESUMEN

OBJECTIVES: To describe the feasibility and evaluate the performance of multiphasic photon-counting detector (PCD) CT for detecting breast cancer and nodal metastases with correlative dynamic breast MRI and digital mammography as the reference standard. METHODS: Adult females with biopsy-proven breast cancer undergoing staging breast MRI were prospectively recruited to undergo a multiphasic PCD-CT using a 3-phase protocol: a non-contrast ultra-high-resolution (UHR) scan and 2 intravenous contrast-enhanced scans with 50 and 180 s delay. Three breast radiologists compared CT characteristics of the index malignancy, regional lymphadenopathy, and extramammary findings to MRI. RESULTS: Thirteen patients underwent both an MRI and PCD-CT (mean age: 53 years, range: 36-75 years). Eleven of thirteen cases demonstrated suspicious mass or non-mass enhancement on PCD-CT when compared to MRI. All cases with metastatic lymphadenopathy (3/3 cases) demonstrated early avid enhancement similar to the index malignancy. All cases with multifocal or multicentric disease on MRI were also identified on PCD-CT (3/3 cases), including a 4 mm suspicious satellite lesion. Four of five patients with residual suspicious post-biopsy calcifications on mammograms were detected on the UHR PCD-CT scan. Owing to increased field-of-view at PCD-CT, a 5 mm thoracic vertebral metastasis was identified at PCD-CT and not with the breast MRI. CONCLUSIONS: A 3-phase PCD-CT scan protocol shows initial promising results in characterizing breast cancer and regional lymphadenopathy similar to MRI and detects microcalcifications in 80% of cases. ADVANCES IN KNOWLEDGE: UHR and spectral capabilities of PCD-CT may allow for comprehensive characterization of breast cancer and may represent an alternative to breast MRI in select cases.


Asunto(s)
Neoplasias de la Mama , Calcinosis , Linfadenopatía , Adulto , Femenino , Humanos , Persona de Mediana Edad , Mama , Ganglios Linfáticos , Tomografía Computarizada por Rayos X
8.
Abdom Radiol (NY) ; 48(1): 63-78, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35567617

RESUMEN

Primary sclerosing cholangitis (PSC) is a chronic cholestatic liver disease characterized by biliary ductal inflammation and fibrosis causing both intrahepatic and extrahepatic biliary strictures and dilatation. There is currently no effective medical treatment and the disease leads to cirrhosis and liver failure, with patients often requiring liver transplantation in end-stage disease. Liver fibrosis is one of the most important factors in determining patient outcome in PSC, and the diagnosis and monitoring of fibrosis are vital to patient care. MRI with magnetic resonance cholangiopancreatography is the non-invasive imaging modality of choice in PSC and is useful for the evaluation of parenchymal and biliary changes. Biliary ductal abnormalities, however, cannot always predict the presence of liver fibrosis and alternative means are needed. MR Elastography (MRE) is the most accurate non-invasive method for assessing liver fibrosis and is particularly helpful in PSC due to unique hepatic manifestations. Like other non-invasive modalities, MRE measures liver stiffness as an indirect method for assessing fibrosis. Given the ability of MRE to assess liver fibrosis and the importance of fibrosis in PSC patients, MRE can reliably predict patient outcome. In this pictorial review, we will review MR findings of PSC, with an emphasis on MRE, and demonstrate scenarios where MRE is particularly helpful in evaluating PSC patients.


Asunto(s)
Colangitis Esclerosante , Colestasis , Diagnóstico por Imagen de Elasticidad , Humanos , Colangitis Esclerosante/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad/métodos , Imagen por Resonancia Magnética/métodos , Cirrosis Hepática/etiología
9.
Radiol Artif Intell ; 2(5): e190183, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33937839

RESUMEN

PURPOSE: To develop a deep learning model that segments intracranial structures on head CT scans. MATERIALS AND METHODS: In this retrospective study, a primary dataset containing 62 normal noncontrast head CT scans from 62 patients (mean age, 73 years; age range, 27-95 years) acquired between August and December 2018 was used for model development. Eleven intracranial structures were manually annotated on the axial oblique series. The dataset was split into 40 scans for training, 10 for validation, and 12 for testing. After initial training, eight model configurations were evaluated on the validation dataset and the highest performing model was evaluated on the test dataset. Interobserver variability was reported using multirater consensus labels obtained from the test dataset. To ensure that the model learned generalizable features, it was further evaluated on two secondary datasets containing 12 volumes with idiopathic normal pressure hydrocephalus (iNPH) and 30 normal volumes from a publicly available source. Statistical significance was determined using categorical linear regression with P < .05. RESULTS: Overall Dice coefficient on the primary test dataset was 0.84 ± 0.05 (standard deviation). Performance ranged from 0.96 ± 0.01 (brainstem and cerebrum) to 0.74 ± 0.06 (internal capsule). Dice coefficients were comparable to expert annotations and exceeded those of existing segmentation methods. The model remained robust on external CT scans and scans demonstrating ventricular enlargement. The use of within-network normalization and class weighting facilitated learning of underrepresented classes. CONCLUSION: Automated segmentation of CT neuroanatomy is feasible with a high degree of accuracy. The model generalized to external CT scans as well as scans demonstrating iNPH.Supplemental material is available for this article.© RSNA, 2020.

10.
Acad Radiol ; 26(12): 1625-1632, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-30878345

RESUMEN

RATIONALE AND OBJECTIVE: Primary sclerosing cholangitis, a chronic liver disease causes heterogeneous parenchymal changes and fibrosis. Liver stiffness measurement (LSM) with magnetic resonance Elastography (MRE) may be affected by this heterogeneous distribution. We evaluated interobserver agreement of LSM in primary sclerosing cholangitis (PSC) with manual and automated methods to study the influence of heterogeneous changes. MATERIALS AND METHODS: A total of 79 consecutive patients with PSC who had a liver MRI and MRE formed the study group. Three readers with 1-3 years' experience in MRE and a MRE expert (11 years' experience) independently performed LSM. Each reader manually drew free hand (fROI) and average (aROI) on stiffness maps. Automatic liver elasticity calculation (ALEC) was used to generate automated LSM. The expert fROI was the reference standard. Correlation analysis and absolute intra-class correlation coefficient (ICC) analysis was performed. RESULTS: LSM data of 79 livers and 315 sections were evaluated. There was excellent ICC between expert and reader fROIs (0.989, 95% confidence interval, and 0.985-0.993) and aROIs (0.971, 95% confidence interval, and 0.953-0.983) and ALEC (0.972, 0.957-0.982) with fROI performing better. The areas measured with fROIs and ALEC had moderate ICC with Expert fROI (0.64 and 0.56, respectively) whereas aROI area had a poor ICC of 0.12. Comparison of multiple methods showed significant differences in LSM between expert fROI and aROI of two readers and no significant differences for fROIs of all three readers. CONCLUSION: LSM with MRE in PSC patients shows excellent interobserver agreement with both fROI and aROI methods with better performance with fROI. fROI may therefore be preferred for LSM measurements in PSC.


Asunto(s)
Colangitis Esclerosante/diagnóstico , Diagnóstico por Imagen de Elasticidad/métodos , Hígado/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Anciano , Colangitis Esclerosante/fisiopatología , Elasticidad , Femenino , Humanos , Hígado/fisiopatología , Masculino , Persona de Mediana Edad , Curva ROC , Adulto Joven
11.
J Clin Med ; 8(5)2019 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-31126105

RESUMEN

In this paper, we present our preliminary findings regarding magnetic resonance elastography (MRE) on the livers of 10 patients with systemic amyloidosis. Mean liver stiffness measurements (LSM) and spleen stiffness measurements (SSM) were obtained. Magnetic resonance imaging (MRI) images were analyzed for the distribution pattern of amyloid deposition. Pearson correlation analysis was performed in order to study the correlation between LSM, SSM, liver span, liver volume, spleen span, spleen volume, serum alkaline phosphatase (ALP), N-terminal pro b-type natriuretic peptide (NT pro BNP), and the kappa and lambda free light chains. An increase in mean LSM was seen in all patients. Pearson correlation analysis showed a statistically significant correlation between LSM and liver volume (r = 0.78, p = 0.007) and kappa chain level (r = 0.65, p = 0.04). Interestingly, LSM did not correlate significantly with SSM (r = 0.45, p = 0.18), liver span (r = 0.57, p = 0.08), or serum ALP (r = 0.60, p = 0.07). However, LSM correlated significantly with serum ALP when corrected for liver volume (partial correlation, r = 0.71, p = 0.03) and NT pro BNP levels (partial correlation, r = 0.68, p = 0.04). MRI review revealed that amyloid deposition in the liver can be diffuse, lobar, or focal. MRE is useful for the evaluation of hepatic amyloidosis and shows increased stiffness in hepatic amyloidosis. MRE has the potential to be a non-invasive quantitative imaging marker for hepatic amyloidosis.

12.
Top Magn Reson Imaging ; 27(5): 319-333, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30289828

RESUMEN

The first clinical application of magnetic resonance elastography (MRE) was in the evaluation of chronic liver disease (CLD) for detection and staging of liver fibrosis. In the past 10 years, MRE has been incorporated seamlessly into a standard magnetic resonance imaging (MRI) liver protocol worldwide. Liver MRE is a robust technique for evaluation of liver stiffness and is currently the most accurate noninvasive imaging technology for evaluation of liver fibrosis. Newer MRE sequences including spin-echo MRE and 3 dimensional MRE have helped in reducing the technical limitations of clinical liver MRE that is performed with 2D gradient recalled echo (GRE) MRE. Advances in MRE technology have led to understanding of newer mechanical parameters such as dispersion, attenuation, and viscoelasticity that may be useful in evaluating pathological processes in CLD and may prove useful in their management.This review article will describe the changes in CLD that cause an increase in stiffness followed by principle and technique of liver MRE. In the later part of the review, we will briefly discuss the advances in liver MRE.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Hepatopatías/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Enfermedad Crónica , Femenino , Humanos , Hígado/diagnóstico por imagen , Hígado/patología , Cirrosis Hepática/diagnóstico por imagen , Cirrosis Hepática/patología , Hepatopatías/patología , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA