1.
J Law Med Ethics ; 35(1): 148-53, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17341223

RESUMEN

Childhood obesity is an increasing health threat. The National Institutes of Health (NIH) is the primary funding agency for research into the causes, mechanisms, consequences, and prevention and treatment of childhood obesity. Using the NIH Strategic Plan for Obesity Research as the framework, this article summarizes the research that has been funded in the past five years as well as new research areas with great potential.


Asunto(s)
Organización de la Financiación/estadística & datos numéricos , National Institutes of Health (U.S.) , Obesidad , Investigación , Adolescente , Adulto , Niño , Organización de la Financiación/economía , Humanos , Obesidad/prevención & control , Obesidad/terapia , Investigación/economía , Investigación/organización & administración , Investigación/estadística & datos numéricos , Estados Unidos
2.
J Clin Densitom ; 7(3): 281-9, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-15319498

RESUMEN

We compared bone mineral density (BMD) and body fat percentage (%fat) between two pencil-beam (Lunar DPX and DPX-L) and two fan-beam (Lunar Prodigy, Hologic Delphi A) dual-energy X-ray absorptiometry (DXA) systems. We examined these values in the total-body, spine, femur, and forearm scans in 78 healthy adults across these four DXA systems. BMD and %fat values were highly correlated among the four instruments. DPX-L gave the lowest mean %fat and Prodigy gave the highest mean %fat for both sexes. The means were system dependent for %fat estimates across the four DXA machines. There was a significant difference detected in BMD estimates across manufacturers, with the Delphi A providing systematically lower values than the Lunar systems in the whole body, spine, and femur sites but higher values than the Lunar systems in the forearm. The present study results show that both %fat and bone mineral estimates between pencil-beam and fan-beam systems are highly correlated, but vary by system. Significant differences exist between the instruments, especially between different manufacturers, and most of the comparisons are sex dependent. We conclude that longitudinal studies should always be evaluated on the same system when possible, and translation models should be used to assess cross-instrument differences.


Asunto(s)
Absorciometría de Fotón/instrumentación , Tejido Adiposo/diagnóstico por imagen , Composición Corporal , Densidad Ósea , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad