1.
Histochem Cell Biol ; 132(1): 83-93, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19319559

RESUMEN

Merkel cells (MCs) are neuroendocrine cells of unknown origin located in the skin. They are identified at electron microscopic level by electron dense granules, at light microscopic level by the presence of cytokeratins 8, 18, 19 and 20. Contradictory reports concerning the presence of other molecules of epithelial as well as neural origin prompted us to investigate whether there are distinct populations of human MCs. Here, we show the heterogeneous expression of villin, N-CAM, NGF-R, and neurofilaments in MCs. Synaptophysin is found in all MCs but with different intensity, nestin is absent. Expression patterns vary between interfollicular epidermis, hair follicles and glabrous epidermis. We conclude that there are distinct populations of MCs, but all populations contain markers for epithelial as well as neural cells. Putative functions of the distinct populations are discussed.


Asunto(s)
Células de Merkel/citología , Antígenos de Diferenciación/metabolismo , Linaje de la Célula , Células Epidérmicas , Epidermis/metabolismo , Folículo Piloso/citología , Folículo Piloso/metabolismo , Humanos , Inmunohistoquímica , Filamentos Intermedios/metabolismo , Células de Merkel/metabolismo , Células Neuroendocrinas/citología , Células Neuroendocrinas/metabolismo
2.
Perspect Psychol Sci ; 12(3): 527-542, 2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-28475467

RESUMEN

In an anonymous 4-person economic game, participants contributed more money to a common project (i.e., cooperated) when required to decide quickly than when forced to delay their decision (Rand, Greene & Nowak, 2012), a pattern consistent with the social heuristics hypothesis proposed by Rand and colleagues. The results of studies using time pressure have been mixed, with some replication attempts observing similar patterns (e.g., Rand et al., 2014) and others observing null effects (e.g., Tinghög et al., 2013; Verkoeijen & Bouwmeester, 2014). This Registered Replication Report (RRR) assessed the size and variability of the effect of time pressure on cooperative decisions by combining 21 separate, preregistered replications of the critical conditions from Study 7 of the original article (Rand et al., 2012). The primary planned analysis used data from all participants who were randomly assigned to conditions and who met the protocol inclusion criteria (an intent-to-treat approach that included the 65.9% of participants in the time-pressure condition and 7.5% in the forced-delay condition who did not adhere to the time constraints), and we observed a difference in contributions of -0.37 percentage points compared with an 8.6 percentage point difference calculated from the original data. Analyzing the data as the original article did, including data only for participants who complied with the time constraints, the RRR observed a 10.37 percentage point difference in contributions compared with a 15.31 percentage point difference in the original study. In combination, the results of the intent-to-treat analysis and the compliant-only analysis are consistent with the presence of selection biases and the absence of a causal effect of time pressure on cooperation.


Asunto(s)
Conducta Cooperativa , Heurística , Relaciones Interpersonales , Toma de Decisiones , Humanos , Intención , Modelos Psicológicos
3.
Cancer Res ; 53(5): 1091-7, 1993 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-8439953

RESUMEN

The antitumor activity of cis-diamminedichloroplatinum(II) (cP) and human recombinant interleukin-1 alpha (IL-1 alpha) was studied in RIF-1 and SC VII solid tumor models and in a cP-resistant subline of RIF-1 designated RIF-R1cP. In RIF-1 tumors, clonogenic cell survival after cP plus IL-1 alpha combinations was highly schedule and IL-1 alpha dose dependent. More than additive clonogenic cell kill was seen when cP was given 6 h before, but not 8 h before or at 2-6 h after IL-1 alpha. Time course studies indicated that maximal clonogenic cell killing was achieved within 4-6 h after the cP plus IL-1 alpha combination, with little or no recovery for up to 24 h. In vivo dose-response studies indicated that cP plus IL-1 alpha combinations induced more clonogenic cell kill than cP alone in all three tumor models, and analysis by the median effect principle indicated highly synergistic antitumor activity. Dexamethasone but not indomethacin inhibited the synergistic interaction. IL-1 alpha had no effect on the cytotoxicity of cP in SCC VII cells in vitro, and neither in vitro hypoxia nor in vivo ischemia, induced by clamping tumor blood supply, significantly affected cP clonogenic cell killing. Increased clonogenic cell killing was seen, however, after removal of the clamp, implicating reperfusion events, such as oxyradical stress, as a potential mechanism for increased cP cytotoxicity in SCC VII solid tumors. The data from our model systems provide a rationale for additional work to define the mechanisms of the synergistic antitumor activity of the cP plus IL-1 alpha combination and indicate that IL-1 alpha might be a useful adjunct to increase the clinical efficacy of cP-containing strategies for both sensitive and cP-resistant cancers.


Asunto(s)
Cisplatino/administración & dosificación , Interleucina-1/administración & dosificación , Neoplasias Experimentales/tratamiento farmacológico , Animales , Supervivencia Celular/efectos de los fármacos , Cisplatino/farmacología , Relación Dosis-Respuesta a Droga , Resistencia a Medicamentos , Sinergismo Farmacológico , Femenino , Interleucina-1/farmacología , Ratones , Ratones Endogámicos C3H , Neoplasias Experimentales/patología , Proteínas Recombinantes/administración & dosificación , Células Tumorales Cultivadas/efectos de los fármacos
4.
J Invest Dermatol ; 111(2): 251-8, 1998 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-9699726

RESUMEN

Few data are available on early regeneration of human epidermis in vivo. We have established a supravital skin organ culture model for epidermal wound healing by setting a central defect (3 mm diameter) in freshly excised skin specimens and culturing under air exposure. Re-epithelialization was followed for up to 7 d by histology and immunohistologic analysis of various markers for differentiation and proliferation. In 12 of 19 cases (63%; 5% fetal calf serum) or six of 21 cases (29%; 2% fetal calf serum), the wounds were re-epithelialized spontaneously after 7 d. After transplantation to the wounds of 1-2 x 10(6) dissociated allogenic cultured epidermal or about 1 x 10(6) autologous outer root sheath keratinocytes, 18 of 21 cases (86%; 5% fetal calf serum) or 17 of 21 cases (81%; 2% fetal calf serum) were healed within the same period. Histologically, early neoepithelium (3 d) was disordered after keratinocyte transplantation, whereas later (7 d) it had gained a more ordered stratification, exhibiting a thin discontinuous granular and a compact horny layer. At this stage, not only hyperproliferative (CK 6) but also, abundantly, maturation-associated cytokeratins (CK 1, CK 10) were detected immunohistochemically. Analyses of regenerated epidermis after transplantation of (i) keratinocytes labeled in vitro with BrdU and (ii) heterosexual keratinocytes by immunohistochemistry and fluorescence in situ hybridization for the Y chromosome, respectively, clearly showed that external keratinocytes are physically integrated into the regenerated epidermis and extendedly contribute to its formation. The data presented here demonstrate improvement and acceleration of epidermal re-epithelialization by transplantation of keratinocytes.


Asunto(s)
Epidermis/fisiología , Queratinocitos/fisiología , Cicatrización de Heridas , Adolescente , Adulto , División Celular , Femenino , Humanos , Queratinocitos/trasplante , Queratinas/análisis , Masculino , Persona de Mediana Edad , Técnicas de Cultivo de Órganos , Regeneración
5.
Int J Radiat Oncol Biol Phys ; 30(4): 985-92, 1994 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-7961003

RESUMEN

PURPOSE: Solid state diodes and/or thermoluminescent dosimeters (TLDs) are often used to measure scattered radiation doses to critical organs immediately adjacent to radiation field sites. The energy-dependent response of these commonly used in vivo dosimeters sometimes makes the interpretation of measured values uncertain. This study investigates scattered radiation arising from the collimator jaws of linear accelerators and the treatment head of a cobalt-60 teletherapy unit. METHODS AND MATERIALS: A thin window Markus-type parallel-plate ionization chamber placed in a polystyrene phantom was employed to document the magnitude, energy composition, and sources of scattered radiation at surfaces near radiation fields. Measurements were taken both with and without additional phantom material covering the ionization chamber, as well as with various distances between the ionization chamber and edges of the radiation fields tested. RESULTS: Data was collected, analyzed and compared for treatment units produced by different manufacturers. It was found that the magnitude of scattered radiation to surfaces immediately adjacent to radiation fields ranged from 1% to 15% of the maximum dose along the beam central axis. These values showed a strong dependence upon distance from the edge of the radiation field, beam energy, collimator setting (field size), and the presence of externally mounted accessories. Teletherapy unit differences due to manufacturing firm origins were found to only slightly affect scattered radiation magnitude, while the orientation of upper and lower collimator jaws had absolutely no effect. CONCLUSIONS: Percent depth dose curves of scattered radiation were obtained and analyzed. The shapes of these depth dose curves suggest the presence of complex energy spectra from secondary electrons and scattered x-rays. Because of the presence of these complex energy spectra in areas immediately adjacent to radiation fields, caution should be observed when interpreting patient doses near radiation fields, if dose values have been measured in vivo using thermoluminescent dosimeters (TLDs) or solid state diodes. Many of these on-patient dosimetry devices are strongly energy dependent and may demonstrate large over- or under-responses in areas dominated by scattered radiation. The results of this study, thus, suggest that ionization chambers are preferred for determination of scattered radiation doses in such regions.


Asunto(s)
Aceleradores de Partículas , Planificación de la Radioterapia Asistida por Computador , Dispersión de Radiación , Humanos , Procesamiento de Señales Asistido por Computador , Análisis Espectral/métodos
6.
Int J Radiat Oncol Biol Phys ; 21(5): 1321-5, 1991 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-1938531

RESUMEN

Stereotactic radiosurgery techniques for a linear accelerator typically use circular radiation fields to produce an essentially spherical radiation distribution with a steep dose gradient. Target volumes are frequently irregular in shape, and circular distributions may irradiate normal tissues to high dose as well as the target volume. Improvements to the dose distribution have been made using multiple target points and optimizing the dose per arc to the target. A retrospective review of 20 radiosurgery patients has suggested that the use of elliptically shaped fields may further improve the match of the radiation distribution to the intended target volume. This hypothesis has been verified with film measurements of the radiation distribution obtained using elliptical radiation beam in a head phantom. Reductions of 40% of the high dose volume have been obtained with elliptical fields compared to circular fields without compromising the dose to the target volume.


Asunto(s)
Radiocirugia/métodos , Dosificación Radioterapéutica , Humanos , Modelos Estructurales , Estudios Retrospectivos
7.
Int J Radiat Oncol Biol Phys ; 20(3): 517-23, 1991 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-1995537

RESUMEN

Stereotactic radiosurgery with a linear accelerator requires the accurate determination of a target volume and an accurate match of the therapeutic radiation dose distribution to the target volume. X ray and CT localizers have been described that are used to define the target volume or target point from angiographic or CT data. To verify the accuracy of these localizers, measurements were made with a target point simulator and an anthropomorphic head phantom. The accuracy of determining a known, high contrast, target point with these localizers was found to be a maximum of +/- 0.5 mm and +/- 1.0 mm for the X ray and CT localizer, respectively. A technique using portal X rays taken with a linear accelerator to verify the target point is also described.


Asunto(s)
Radioterapia/instrumentación , Técnicas Estereotáxicas/instrumentación , Tomografía Computarizada por Rayos X/instrumentación , Dosificación Radioterapéutica
8.
Int J Radiat Oncol Biol Phys ; 15(1): 213-8, 1988 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-3391817

RESUMEN

This paper describes our experience in using the T1 and T2 relaxation times for quantitative evaluation of brain and brain tumor response to radiation therapy. Twenty-two computed T1 and 22 computed T2 images were obtained from 66 routine inversion-recovery and spin-echo magnetic resonance (MR) brain scans. The relaxation times of the brain tissues, determined from the computed images, were examined as a function of the absorbed dose. Statistical evaluation of the results showed no significant difference between the relaxation times of irradiated and not irradiated tissues, including tumor and normal white matter. Influence of the magnetic field strength and imaging techniques on the computed T1 and T2 values was confirmed. We conclude that the relaxation time values, as obtained today using conventional MR scanner and standard software, are not specific enough to warrant a correct assessment of the acute radiation effect on the brain tissues.


Asunto(s)
Neoplasias Encefálicas/radioterapia , Encéfalo/efectos de la radiación , Imagen por Resonancia Magnética , Adolescente , Adulto , Niño , Humanos , Persona de Mediana Edad
9.
Int J Radiat Oncol Biol Phys ; 24(4): 777-80, 1992.
Artículo en Inglés | MEDLINE | ID: mdl-1429104

RESUMEN

Stereotactic radiosurgery with a linear accelerator requires an accurate match of the therapeutic radiation distribution to the localized target volume. Techniques for localization of the target volume using CT scans and/or angiograms have been described. Alignment of the therapeutic radiation distribution to the intended point in stereotactic space is usually accomplished using precision mechanical scales which attach to the head ring. The present work describes a technique used to verify that the stereotactic coordinates of the center of the intended radiation distribution are in agreement with the localized target point coordinates. This technique uses anterior/posterior and lateral accelerator portal verification films to localize the stereotactic coordinates of the center of the radiation distribution with the patient in the treatment position. The results of 26 cases have been analyzed. Alignment errors of the therapeutic radiation distribution in excess of 1 mm have been found using the portal film verification procedure.


Asunto(s)
Encéfalo/cirugía , Garantía de la Calidad de Atención de Salud , Radiocirugia , Técnicas Estereotáxicas , Angiografía Cerebral , Humanos , Tomografía Computarizada por Rayos X
10.
Int J Radiat Oncol Biol Phys ; 21(6): 1621-5, 1991 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-1938572

RESUMEN

Computer controlled high dose-rate (HDR) brachytherapy afterloading machines are equipped with a single, miniaturized, high activity Ir-192 source that can be rapidly moved in fine increments among several channels. Consequently, by appropriate programming of source dwell positions and times, the dose distribution can be optimized as desired. We have explored the optimization potential of this new technology for two applications: (a) cervix brachytherapy, and (b) transvaginal irradiation. Cervix brachytherapy with a gynecologic ring applicator was simulated by 48 sources of relative activities ranging from 0.17 to 1.00 that were equally distributed between the tandem and the ring. The results confirmed that the optimized distribution of physical doses are superior to those achievable with standard brachytherapy sources and applicators. For example, with five-point optimization, the relative dose-rate in the rectum was only 47% of that in point A; for standard application the dose rate was 47% higher. For transvaginal application 27 sources of relative activities between 0.07-0.79 were placed in the ring and a single source of unit strength in the tandem. Using dose distribution homogeneity as an optimization criterion, the results (+/- 2.5%) were again superior to those obtained for commonly used double ovoid (+/- 15%), linear cylinder (+/- 27%), or a "T" source (31%).


Asunto(s)
Braquiterapia , Cuello del Útero , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Alta Energía , Vagina , Femenino , Humanos
11.
Int J Radiat Oncol Biol Phys ; 24(4): 795-801, 1992.
Artículo en Inglés | MEDLINE | ID: mdl-1429107

RESUMEN

Although high dose-rate brachytherapy with a single, rapidly moving radiation source is becoming a common treatment modality, a suitable formalism for determination of the dose delivered by a moving radiation source has not yet been developed. At present, brachytherapy software simulates high dose-rate treatments using only a series of stationary sources, and consequently fails to account for the dose component delivered while the source is in motion. We now describe a practical model for determination of the true, total dose administered. The algorithm calculates both the dose delivered while the source is in motion within and outside of the implanted volume (dynamic component), and the dose delivered while the source is stationary at a series of fixed dwell points. It is shown that the dynamic dose element cannot be ignored because it always increases the dose at the prescription points and, in addition, distorts the dose distribution within and outside of the irradiated volume. Failure to account for the dynamic dose component results in dosimetric errors that range from significant (> 10%) to negligible (< 1%), depending on the prescribed dose, source activity, and source speed as defined by the implant geometry.


Asunto(s)
Braquiterapia/métodos , Planificación de la Radioterapia Asistida por Computador , Humanos , Dosis de Radiación
12.
Int J Radiat Oncol Biol Phys ; 22(1): 175-80, 1992.
Artículo en Inglés | MEDLINE | ID: mdl-1727115

RESUMEN

A computer-controlled stereotaxic radiotherapy system based on a low-frequency magnetic field technology integrated with a single fixation point stereotaxic guide has been designed and instituted. The magnetic field, generated in space by a special field source located in the accelerator gantry, is digitized in real time by a field sensor that is six degree-of-freedom measurement device. As this sensor is an integral part of the patient stereotaxic halo, the patient position (x, y, z) and orientation (azimuth, elevation, roll) within the accelerator frame of reference are always known. Six parameters--three coordinates and three Euler space angles--are continuously transmitted to a computer where they are analyzed and compared with the stereotaxic parameters of the target point. Hence, the system facilitates rapid and accurate patient set-up for stereotaxic treatment as well as monitoring of patient during the subsequent irradiation session. The stereotaxic system has been developed to promote the integration of diagnostic and therapeutic procedures, with the specific aim of integrating CT and/or MR aided tumor localization and long term (4- to 7-week) fractionated radiotherapy of small intracranial and ocular lesions.


Asunto(s)
Radioterapia Asistida por Computador/métodos , Técnicas Estereotáxicas , Fenómenos Electromagnéticos , Humanos , Planificación de la Radioterapia Asistida por Computador
13.
Int J Radiat Oncol Biol Phys ; 17(5): 1111-4, 1989 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-2808046

RESUMEN

Spatial definition of an intraocular tumor and subsequent determination of the actual position of an implanted eye plaque are essential for adequate ocular brachytherapy treatment planning. However, a method for verification of the plaque placement which would provide required 3-dimensional information is not available at present. In addition, tumor localization procedures, including ultrasonography and CT techniques, cannot always offer the precision needed for 3-dimensional definition of an intraocular target. This communication describes a magnetic resonance imaging technique specifically developed for both localization and verification procedures. A 1.5 Tesla magnetic resonance scanner, spin-echo pulse sequence (echo time 30 msec, repetition time 700 msec), and commercially available surface coil were used to obtain a series of transverse, coronal, and sagittal images of a slice thickness of 3 mm. Usually, eight scans in each of the three planes were needed for adequate coverage of the orbit. The required patient set-up and data acquisition time did not exceed 40 minutes. With a data matrix size of 256 X 256 pixels and 13 cm field of view, localization and verification were accomplished with a precision of 0.5 mm. Our results suggest that the magnetic resonance imaging technique permits precise integration of diagnostic and therapeutic procedures, and in addition provides adequate data for accurate treatment planning. We conclude that magnetic resonance imaging is the preferred diagnostic technique for episcleral brachytherapy.


Asunto(s)
Braquiterapia/métodos , Neoplasias del Ojo/radioterapia , Melanoma/radioterapia , Humanos , Imagen por Resonancia Magnética , Esclerótica
14.
Radiat Res ; 145(2): 150-6, 1996 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-8606924

RESUMEN

Interleukin-1 (IL-1) has radioprotective activity in hematopoietic lineages and in other normal cell renewal systems, but little is known about the effects of IL-1 alpha on the radiosensitivity of tumor cell populations. The present studies were conducted to investigate the effects of IL-1 alpha on the radiosensitivity of clonogenic cells in RIF-1 and SCC-7 tumors. Radioresistance was detected within 2-4 after administration of IL-1 alpha (0.5 micrograms/mouse, ip) and characterized by increases in D(o), Dq, alpha/beta and SF2. This radioresistance was similar to that seen in tumors rendered totally hypoxic before X irradiation. Tirapazamine, a hypoxic cell cytotoxin, and IL-1 alpha had synergistic schedule-dependent antitumor activity in vivo, suggesting that IL-1-induced radioresistance in vivo is due to hypoxia. Radioresistance induced by IL-1 alpha was transient, and the data suggested reoxygenation within 12 h. In vitro, IL-1 alpha had no direct effect on the radiosensitivity of SCC-7 cells in tissue culture under aerobic conditions. However, an increase in D(o), alpha/beta and SF2 was seen in clonogenic tumor cells from primary cultures treated with IL-1 alpha under aerobic conditions. Superoxide dismutase and catalase prevented the induction of radioresistance by IL-1 alpha in vitro, suggesting that oxidative responses from tumor macrophages after administration of IL-1 alpha may be responsible for induced radioresistance by IL-1 in vitro. Although oxidant stress induced by IL-1 and in vitro in our models, the mechanisms by which such responses modulate tumor radiosensitivity in vivo and in vitro are likely quite different.


Asunto(s)
Interleucina-1/administración & dosificación , Interleucina-1/farmacología , Protectores contra Radiación/administración & dosificación , Fármacos Sensibilizantes a Radiaciones/administración & dosificación , Animales , Catalasa/metabolismo , Supervivencia Celular/efectos de la radiación , Células Clonales , Sinergismo Farmacológico , Hipoxia/metabolismo , Ratones , Neoplasias Experimentales/radioterapia , Traumatismos Experimentales por Radiación , Proteínas Recombinantes , Superóxido Dismutasa/metabolismo , Tirapazamina , Triazinas/administración & dosificación , Células Tumorales Cultivadas/efectos de la radiación , Irradiación Corporal Total
15.
Arch Dermatol ; 111(3): 328-30, 1975 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-1119832

RESUMEN

Blood flow in normal skin and skin treated with ultraviolet light (UVL) has been determined by measuring the clearance of epicutaneously applied xenon 133 gas. Mean blood flow in UVL-irradiated skin was 25.7 ml/100 gm/min, which is about twice that found in normal skin (12.2 ml/100 gm/min). Orally administered indomethacin reduced by one third the increase in blood flow produced by UVL irradiation.


Asunto(s)
Circulación Sanguínea/efectos de la radiación , Indometacina/administración & dosificación , Piel/irrigación sanguínea , Rayos Ultravioleta , Circulación Sanguínea/efectos de los fármacos , Humanos , Indometacina/farmacología , Placebos , Radioisótopos , Flujo Sanguíneo Regional/efectos de los fármacos , Flujo Sanguíneo Regional/efectos de la radiación , Xenón
16.
Med Phys ; 10(3): 333-6, 1983.
Artículo en Inglés | MEDLINE | ID: mdl-6410163

RESUMEN

Dosimetry for 10-MV x rays has been extended to radiation fields smaller than 4 X 4 cm which may be suitable for radiation therapy of small lesions, e.g., intracranial tumors, benign or malignant. Special consideration in this study was given to (i) the variation of dose with field size (collimator and phantom scatter), (ii) the central axis percentage depth doses, and (iii) the moving-beam therapy dose distribution. We conclude that simple dosimetric techniques can provide adequate physics background for stereotaxic radiosurgery with small radiation fields and high-energy x rays.


Asunto(s)
Dosis de Radiación , Radioterapia de Alta Energía/métodos , Neoplasias Encefálicas/radioterapia , Aceleradores de Partículas , Dispersión de Radiación , Técnicas Estereotáxicas
17.
Med Phys ; 12(4): 469-72, 1985.
Artículo en Inglés | MEDLINE | ID: mdl-3929051

RESUMEN

A stereotaxic radiotherapy technique that permits accurate delivery of highly localized dose to a small intracranial target has been developed. The technique facilitates precise integration of the diagnostic and therapeutic procedures including target localization, treatment planning, simulation, repetitive patient irradiation, and daily treatment verification. A conventional linear accelerator and computed tomography scanner as well as special diagnostic and therapeutic guides are used. A suitable dosimetric distribution is achieved using arc therapy with small radiation fields and 10-MV x rays.


Asunto(s)
Neoplasias Encefálicas/radioterapia , Radioterapia de Alta Energía/métodos , Técnicas Estereotáxicas , Fenómenos Biofísicos , Biofisica , Neoplasias Encefálicas/diagnóstico por imagen , Humanos , Modelos Estructurales , Dosificación Radioterapéutica , Tomografía Computarizada por Rayos X
18.
Med Phys ; 19(6): 1451-3, 1992.
Artículo en Inglés | MEDLINE | ID: mdl-1461209

RESUMEN

Assessment of electron beam energy and its long term stability is part of standard quality assurance practice in radiation oncology. Conventional depth-ionization or depth-film density measurements are time consuming both in terms of data acquisition and analysis. A procedure is described utilizing ionization measurements at two energy specific depths. It is based on a linear relationship between electron beam energy and its practical range. Energy shifts within the range covered by the two measurement depths are easily resolved. Within a range of +/- 0.50 MeV (+/- 1.30 MeV) around the established mean incident energy of 5.48 MeV (20.39 MeV), the method accuracy is better than 0.10 MeV.


Asunto(s)
Electrones , Aceleradores de Partículas , Radioterapia de Alta Energía/normas , Humanos
19.
Med Phys ; 19(1): 181-5, 1992.
Artículo en Inglés | MEDLINE | ID: mdl-1620045

RESUMEN

Stereotactic radiosurgery of the brain may be accomplished with a linear accelerator by performing several noncoplanar arcs of a highly collimated beam focused at a point. The shape of the radiation distribution produced by this technique is affected by the beam energy, field size, and the number and size of the arcs. The influence of these parameters on the resulting radiation distributions was analyzed by computing dose volume histograms for a typical brain. Dose volume functions were computed for: (a) the energy range of 4-24 MV x rays; (b) target sizes of 1-4 cm; and (c) 1-11 arcs and dynamic rotation. The dose volume histograms were found to be dependent on the number of arcs for target sizes of 1-4 cm. However, these differences were minimal for techniques with 4 arcs or more. The influence of beam energy on the dose volume histogram was also found to be minimal.


Asunto(s)
Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Encéfalo/anatomía & histología , Humanos , Aceleradores de Partículas
20.
Med Phys ; 18(6): 1266-70, 1991.
Artículo en Inglés | MEDLINE | ID: mdl-1753916

RESUMEN

Dosimetry calculations for iridium-192 sources generally assume that a sufficient medium surrounds both the iridium source(s) and the point of calculation so that full scattering conditions exist. In several clinical applications the iridium sources may be anatomically located so that the full scattering requirement is not satisfied. To assess the magnitude of this problem, relative measurements were made with a small ionization chamber in phantoms near air and lung-equivalent interfaces. Dose reduction caused by decreasing the volume of scattering material near these interfaces was then evaluated for a few clinical applications. The results show that reductions on the order of 8% may be expected at the interface with minimal dose reduction within the volume of the implant itself. In addition, the results indicate the verification of source strength of iridium sources in phantom require phantom dimensions determined by the source-chamber separation distance.


Asunto(s)
Braquiterapia , Radioisótopos de Iridio/uso terapéutico , Radiometría/métodos , Dosificación Radioterapéutica , Humanos , Modelos Estructurales , Radiometría/instrumentación , Dispersión de Radiación