1.
Healthcare (Basel) ; 11(4)2023 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-36833049

RESUMEN

The world is facing rapid global aging. Global countries are concerned about the development of aging societies and related topics ranging from successful, healthy, and active aging in the past to the current creative aging (CA) perspective. However, in-depth research on applying esthetics to promote community CA in Taiwan is lacking. To address this deficiency, the Hushan community in Douliu City, Yunlin County was selected as the research area, and the CA perspective was adopted to promote community CA through multi-stage intergenerational esthetic co-creation (IEC) workshops. A model for applying IEC workshops to promote CA was constructed. Using the action research approach, community CA enabled the elderly to identify with their inherent values, opening new possibilities for the provision of elderly social care. This study explored the psychological impacts of implementing IEC workshops on the elderly, analyzed their interactions with peers and youth, helped the elderly review their lives, analyzed relevant data to construct a practical model for applying IEC workshops to promote CA, and provided the data collected during the multi-stage applications of CA and an IEC model for promoting CA as a reference for future researchers, thereby opening new possibilities for sustainable care in aging societies.

2.
Clin Biochem ; 38(3): 278-81, 2005 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15708551

RESUMEN

OBJECTIVES: Self-monitoring blood uric acid device is an important tool for patients to efficiently monitor their blood uric acid concentrations. The objective of the present study was to evaluate the accuracy of EasyTouch uric acid monitoring system. DESIGN AND METHODS: Capillary blood uric acid concentrations measured using EasyTouch and the reference values obtained from COBAS MIRA were performed in the Department of Laboratory Medicine, Wei-Gong Memorial Hospital. Results were evaluated using (1) linear regression analysis, (2) percentage of readings within a defined range of deviation from the reference value, and (3) coefficients of variation (CVs) calculated from 60 measurements in series. RESULTS: The window of the 177 EasyTouch readings covered a wide range from 0.1785 to 0.6367 mmol/L (3-10.7 mg/dL). Linear regression analysis yielded a regression slope of 0.975, an intercept of 0.0118 mmol/L and an R2 of 0.8966. Of the EasyTouch readings, 64 (36.2%), 61 (34.5%), 34 (19.2%), 9 (5.08%), and 9 (5.08%) were within the intervals of <5%, 5-10%, 10-15%, 15-17%, and >17%, respectively, of the reference values. Further analysis for the performance of each lot of strips showed that both coefficients of correlation and the percentages of readings within the CLIA's criterion (+/-17%), respectively, were in a narrow range from 0.8777 to 0.9541 and from 92.1% to 100%. The CVs for the seven lots of strips (lot 1 to lot 7) ranged from 2.93% to 6.33%, 3.2% to 5.9%, 3.64% to 7.0%, 2.84% to 7.6%, 2.68% to 5.42%, 3.03% to 6.93%, and 3.18% to 5.17%, respectively. CONCLUSION: EasyTouch is an acceptable diagnostic device which provides accurate uric acid measurements.


Asunto(s)
Ácido Úrico/sangre , Adulto , Anciano , Anciano de 80 o más Años , Electroquímica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico/instrumentación , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Urato Oxidasa
3.
Clin Chim Acta ; 349(1-2): 135-41, 2004 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-15469866

RESUMEN

BACKGROUND: Self-monitoring blood glucose device is an important tool for diabetes patients to efficiently control their blood glucose concentrations. We evaluated the accuracy of EasyTouch glucose monitoring system. METHODS: Capillary blood glucose concentrations measured using EasyTouch and the reference values obtained from Yellow Springs Instruments (YSI) 2300 STAT were performed in the Department of Laboratory Medicine, Wei-Gong Memorial Hospital. Results were evaluated using (1) linear regression analysis, (2) Clarke Error Grid analysis, (3) percentage of readings within a defined range of deviation from the reference value, (4) bias plots, and (5) coefficients of variation (CVs) calculated from 60 measurements in series. RESULTS: The window of the 516 EasyTouch readings covered a range from 42 to 555 mg/dl. Linear regression analysis yielded a regression slope 0.9972, intercept 1.899 mg/dl, r2 0.9571, and Syx 14.89 mg/dl. A Clarke Error Grid analysis showed 100% of the EasyTouch readings in clinically acceptable zones A and B. Of the EasyTouch readings, 98.3%, 91.9%, 78.3% and 46.9% were found within +/-20%, +/-15%, +/-10%, and +/-5%, respectively, of the reference values. Further analysis showed that the percentage of EasyTouch readings within the defined intervals was similar in three glucose ranges (< or =100, 101-200, and > or =201 mg/dl). The CVs for the four lots of strips (lot 1 to lot 4) ranged from 3.5 to 5.5%, 2.1 to 4.8%, 1.8 to 3.6%, and 3.0 to 5.7%, respectively. CONCLUSIONS: EasyTouch provides high accurate and precise glucose readings over a wide range of glucose concentrations.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/normas , Glucemia/análisis , Diabetes Mellitus/sangre , Hematócrito , Humanos , Reproducibilidad de los Resultados , Ácido Úrico/sangre