1.
J Appl Clin Med Phys ; 23(8): e13718, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35829667

RESUMEN

Qualified medical physicists (QMPs) are in a unique position to influence the creation and application of key performance indicators (KPIs) across diverse practices in health care. Developing KPIs requires the involvement of stakeholders in the area of interest. Fundamentally, KPIs should provide actionable information for the stakeholders using or viewing them. During development, it is important to strongly consider the underlying data collection for the KPI, making it automatic whenever possible. Once the KPI has been validated, it is important to setup a review cycle and be prepared to adjust the underlying data or action levels if the KPI is not performing as intended. Examples of specific KPIs for QMPs of common scopes of practice are provided to act as models to aid in implementation. KPIs are a useful tool for QMPs, regardless of the scope of practice or practice environment, to enhance the safety and quality of care being delivered.


Asunto(s)
Indicadores de Calidad de la Atención de Salud , Humanos
2.
J Appl Clin Med Phys ; 22(3): 131-140, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33608992

RESUMEN

PURPOSE: To demonstrate that variation in chemical composition has a negligible effect on the mapping curve from relative electron density (RED) to proton stopping power ratio (SPR), and to establish the theoretical framework of using Megavoltage (MV) computed tomography (CT), instead of kilovoltage (kV) dual energy CT, to accurately estimate proton SPR. METHODS: A simulation study was performed to evaluate the effect of chemical composition variation on kVCT number and proton SPR. The simulation study involved both reference and simulated human tissues. The reference human tissues, together with their physical densities and chemical compositions, came from the ICRP publication 23. The simulated human tissues were created from the reference human tissues assuming that elemental percentage weight followed a Gaussian distribution. For all tissues, kVCT number and proton SPR were obtained through (a) theoretical calculation from tissue's physical density and chemical composition which served as the ground truth, and (b) estimation from RED using the calibration curves established from the stoichiometric method. Deviations of the estimated values from the calculated values were quantified as errors in using RED to estimate kVCT number and proton SPR. RESULTS: Given a chemical composition variation of 5% (1σ) of the nominal percentage weights, the total estimation error of using RED to estimate kVCT number was 0.34%, 0.62%, and 0.77% and the total estimation error of using RED to estimate proton SPR was 0.30%, 0.22%, and 0.16% for fat tissues, non-fat soft tissues and bone tissues, respectively. CONCLUSION: Chemical composition had a negligible effect on the method of using RED to determine proton SPR. RED itself is sufficient to accurately determine proton SPR. MVCT number maintains a superb linear relationship with RED because it is highly dominated by Compton scattering. Therefore, MVCT has great potential in reducing the proton range uncertainty.


Asunto(s)
Terapia de Protones , Protones , Calibración , Estudios de Factibilidad , Humanos , Fantasmas de Imagen , Tomografía Computarizada por Rayos X , Incertidumbre
3.
J Appl Clin Med Phys ; 20(7): 15-27, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31112371

RESUMEN

BACKGROUND: Esophageal carcinoma is the eighth most common cancer in the world. Volumetric-modulated arc therapy (VMAT) is widely used to treat distal esophageal carcinoma due to high conformality to the target and good sparing of organs at risk (OAR). It is not clear if small-spot intensity-modulated proton therapy (IMPT) demonstrates a dosimetric advantage over VMAT. In this study, we compared dosimetric performance of VMAT and small-spot IMPT for distal esophageal carcinoma in terms of plan quality, plan robustness, and interplay effects. METHODS: 35 distal esophageal carcinoma patients were retrospectively reviewed; 19 patients received small-spot IMPT and the remaining 16 of them received VMAT. Both plans were generated by delivering prescription doses to clinical target volumes (CTVs) on phase-averaged 4D-CT's. The dose-volume-histogram (DVH) band method was used to quantify plan robustness. Software was developed to evaluate interplay effects with randomized starting phases for each field per fraction. DVH indices were compared using Wilcoxon rank-sum test. For fair comparison, all the treatment plans were normalized to have the same CTVhigh D95% in the nominal scenario relative to the prescription dose. RESULTS: In the nominal scenario, small-spot IMPT delivered statistically significantly lower liver Dmean and V30Gy[RBE] , lung Dmean , heart Dmean compared with VMAT. CTVhigh dose homogeneity and protection of other OARs were comparable between the two treatments. In terms of plan robustness, the IMPT and VMAT plans were comparable for kidney V18Gy[RBE] , liver V30Gy[RBE] , stomach V45Gy[RBE] , lung Dmean , V5Gy[RBE] , and V20Gy[RBE] , cord Dmax and D 0.03 c m 3 , liver Dmean , heart V20Gy[RBE] , and V30Gy[RBE] , but IMPT was significantly worse for CTVhigh D95% , D 2 c m 3 , and D5% -D95% , CTVlow D95% , heart Dmean , and V40Gy[RBE] , requiring careful and experienced adjustments during the planning process and robustness considerations. The small-spot IMPT plans still met the standard clinical requirements after interplay effects were considered. CONCLUSIONS: Small-spot IMPT decreases doses to heart, liver, and total lung compared to VMAT as well as achieves clinically acceptable plan robustness. Our study supports the use of small-spot IMPT for the treatment of distal esophageal carcinoma.


Asunto(s)
Neoplasias Esofágicas/radioterapia , Terapia de Protones/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Órganos en Riesgo/efectos de la radiación , Selección de Paciente , Pronóstico , Dosificación Radioterapéutica , Estudios Retrospectivos
4.
J Appl Clin Med Phys ; 18(6): 88-96, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28921881

RESUMEN

Monte Carlo (MC) simulation has been used to generate commissioning data for the beam modeling of treatment planning system (TPS). We have developed a method called radial projection (RP) for postprocessing of MC-simulation-generated data. We used the RP method to reduce the statistical uncertainty of the lateral profile of proton pencil beams with axial symmetry. The RP method takes advantage of the axial symmetry of dose distribution to use the mean value of multiple independent scores as the representative score. Using the mean as the representative value rather than any individual score results in substantial reduction in statistical uncertainty. Herein, we present the concept and step-by-step implementation of the RP method, as well as show the advantage of the RP method over conventional measurement methods for generating lateral profile. Lateral profiles generated by both methods were compared to demonstrate the uncertainty reduction qualitatively, and standard error comparison was performed to demonstrate the reduction quantitatively. The comparisons showed that statistical uncertainty was reduced substantially by the RP method. Using the RP method to postprocess MC data, the corresponding MC simulation time was reduced by a factor of 10 without quality reduction in the generated result from the MC data. We concluded that the RP method is an effective technique to increase MC simulation efficiency for generating lateral profiles for axially symmetric pencil beams.


Asunto(s)
Algoritmos , Simulación por Computador , Método de Montecarlo , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Humanos , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos , Incertidumbre
5.
J Appl Clin Med Phys ; 18(4): 76-83, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28503916

RESUMEN

This work is to show which is more relevant to cause local failures (LFs) due to patient setup uncertainty between the planning target volume (PTV) underdosage and the potential target underdosage subject to patient setup uncertainties in head and neck (H&N) cancer treated with volumetric-modulated arc therapy (VMAT). Thirteen LFs in 10 H&N patients treated by VMAT were analyzed. Measures have been taken to minimize the chances of insufficient target delineation for these patients and the patients were clinically determined to have LF based on the PET/CT scan results by an experienced radiologist and then reviewed by a second experienced radiation oncologist. Two methods were used to identify the possible locations of LF due to underdosage: (a) examining the standard VMAT plan, in which the underdosed volume in the nominal dose distribution (UVN) was generated by subtracting the volumes receiving the prescription doses from PTVs, and (b) plan robustness analysis, in which in addition to the nominal dose distribution, six perturbed dose distributions were created by translating the CT iso-center in three cardinal directions by the PTV margin. The coldest dose distribution was represented by the minimum of the seven doses in each voxel. The underdosed volume in the coldest dose distribution (UVC) was generated by subtracting the volumes receiving the prescription doses in the coldest dose distribution from the volumes receiving the prescription doses in the nominal dose distribution. UVN and UVC were subsequently examined for spatial association with the locations of LF. The association was tested using the binominal distribution and the Fisher's exact test of independence. We found that of 13 LFs, 11 were associated with UVCs (P = 0.011), while three were associated with UVNs (P = 0.99). We concluded that the possible target underdosage due to patient setup uncertainties appeared to be a more relevant factor associated with LF in VMAT for H&N cancer than the compromised PTV coverage at least for the patients included in this study.


Asunto(s)
Neoplasias de Cabeza y Cuello/radioterapia , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada/métodos , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Dosificación Radioterapéutica
6.
J Appl Clin Med Phys ; 17(2): 441-460, 2016 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-27074465

RESUMEN

On-board magnetic resonance (MR) image guidance during radiation therapy offers the potential for more accurate treatment delivery. To utilize the real-time image information, a crucial prerequisite is the ability to successfully segment and track regions of interest (ROI). The purpose of this work is to evaluate the performance of different segmentation algorithms using motion images (4 frames per second) acquired using a MR image-guided radiotherapy (MR-IGRT) system. Manual con-tours of the kidney, bladder, duodenum, and a liver tumor by an experienced radiation oncologist were used as the ground truth for performance evaluation. Besides the manual segmentation, images were automatically segmented using thresholding, fuzzy k-means (FKM), k-harmonic means (KHM), and reaction-diffusion level set evolution (RD-LSE) algorithms, as well as the tissue tracking algorithm provided by the ViewRay treatment planning and delivery system (VR-TPDS). The performance of the five algorithms was evaluated quantitatively by comparing with the manual segmentation using the Dice coefficient and target registration error (TRE) measured as the distance between the centroid of the manual ROI and the centroid of the automatically segmented ROI. All methods were able to successfully segment the bladder and the kidney, but only FKM, KHM, and VR-TPDS were able to segment the liver tumor and the duodenum. The performance of the thresholding, FKM, KHM, and RD-LSE algorithms degraded as the local image contrast decreased, whereas the performance of the VP-TPDS method was nearly independent of local image contrast due to the reference registration algorithm. For segmenting high-contrast images (i.e., kidney), the thresholding method provided the best speed (< 1 ms) with a satisfying accuracy (Dice = 0.95). When the image contrast was low, the VR-TPDS method had the best automatic contour. Results suggest an image quality determination procedure before segmentation and a combination of different methods for optimal segmentation with the on-board MR-IGRT system.


Asunto(s)
Algoritmos , Neoplasias Duodenales/radioterapia , Procesamiento de Imagen Asistido por Computador/métodos , Neoplasias Renales/radioterapia , Neoplasias Hepáticas/radioterapia , Imagen por Resonancia Magnética/métodos , Radioterapia Guiada por Imagen/métodos , Neoplasias de la Vejiga Urinaria/radioterapia , Humanos , Imagenología Tridimensional/métodos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos
7.
J Appl Clin Med Phys ; 17(1): 121-131, 2016 01 08.
Artículo en Inglés | MEDLINE | ID: mdl-26894342

RESUMEN

The purpose of this study was to describe the clinical implementation of a magnetic resonance image (MRI)-based approach for adaptive intracavitary brachytherapy (ICBT) of cervix cancer patients. Patients were implanted with titanium tandem and colpostats. MR imaging was performed on a 1.5-T Philips scanner using T2-weighted (T2W), proton-density weighted (PDW), and diffusion-weighted (DW) imaging sequences. Apparent diffusion coefficient (ADC) maps were generated from the DW images. All images were fused. T2W images were used for the definition of organs at risk (OARs) and dose points. ADC maps in conjunction with T2W images were used for target delineation. PDW images were used for applicator definition. Forward treatment planning was performed using standard source distribution rules normalized to Point A. Point doses and dose-volume parameters for the tumor and OARs were exported to an automated dose-tracking application. Brachytherapy doses were adapted for tumor shrinkage and OAR variations during the course of therapy. The MRI-based ICBT approach described here has been clinically implemented and is carried out for each brachytherapy fraction. Total procedure time from patient preparation to delivery of treatment is typically 2 hrs. Implementation of our tech-nique for structure delineation, applicator definition, dose tracking, and adaptation is demonstrated using treated patient examples. Based on published recommendations and our clinical experience in the radiation treatment of cervix cancer patients, we have refined our standard approach to ICBT by 1) incorporating a multisequence MRI technique for improved visualization of the target, OARs, and applicator, and by 2) implementing dose adaptation by use of automated dose tracking tools.


Asunto(s)
Carcinoma in Situ/patología , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Órganos en Riesgo/efectos de la radiación , Neoplasias del Cuello Uterino/patología , Carcinoma in Situ/radioterapia , Femenino , Humanos , Estadificación de Neoplasias , Neoplasias del Cuello Uterino/radioterapia
8.
World J Urol ; 33(1): 69-75, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24647879

RESUMEN

PURPOSE: The purpose of the study was to evaluate the utility of a 3 T pelvic magnetic resonance imaging (MRI) in detecting a local recurrence in post-prostatectomy prostate cancer patients prior to receiving adjuvant or salvage intensity-modulated radiation therapy (IMRT). METHODS: Ninety prostate cancer patients status post-prostatectomy with rising prostate-specific antigen (PSA) had a 3 T pelvic MRI prior to IMRT. The following variables were analyzed for predicting positive findings on MRI: initial presenting and initial post-op PSA, PSA at the time of imaging, PSA velocity, surgical margins, Gleason score, pathological stage, pre-RT digital rectal examination, and type of surgical prostatectomy. RESULTS: The only significant variable predictive of a positive MRI was positive margins. Specifically, 15 of 46 (33 %) patients with positive margins had a positive MRI, while 5 of 44 (11 %) patients with negative margins had a positive MRI. In the MRI positive group, the location of the positive findings on MRI corresponded with the pathology report in 9 of 12 (75 %) cases. CONCLUSION: Post-prostatectomy patients with pathologic positive margins are three times more likely to have positive findings on a 3 T MRI.


Asunto(s)
Imagen por Resonancia Magnética , Recurrencia Local de Neoplasia/diagnóstico , Prostatectomía , Neoplasias de la Próstata/diagnóstico , Neoplasias de la Próstata/cirugía , Anciano , Anciano de 80 o más Años , Humanos , Masculino , Persona de Mediana Edad , Neoplasia Residual , Antígeno Prostático Específico , Neoplasias de la Próstata/radioterapia , Radioterapia Adyuvante , Radioterapia de Intensidad Modulada , Terapia Recuperativa , Sensibilidad y Especificidad , Resultado del Tratamiento
9.
Acta Oncol ; 54(9): 1474-82, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26206517

RESUMEN

BACKGROUND: Onboard magnetic resonance imaging (OB-MRI) for daily localization and adaptive radiotherapy has been under development by several groups. However, no clinical studies have evaluated whether OB-MRI improves visualization of the target and organs at risk (OARs) compared to standard onboard computed tomography (OB-CT). This study compared visualization of patient anatomy on images acquired on the MRI-(60)Co ViewRay system to those acquired with OB-CT. MATERIAL AND METHODS: Fourteen patients enrolled on a protocol approved by the Institutional Review Board (IRB) and undergoing image-guided radiotherapy for cancer in the thorax (n = 2), pelvis (n = 6), abdomen (n = 3) or head and neck (n = 3) were imaged with OB-MRI and OB-CT. For each of the 14 patients, the OB-MRI and OB-CT datasets were displayed side-by-side and independently reviewed by three radiation oncologists. Each physician was asked to evaluate which dataset offered better visualization of the target and OARs. A quantitative contouring study was performed on two abdominal patients to assess if OB-MRI could offer improved inter-observer segmentation agreement for adaptive planning. RESULTS: In total 221 OARs and 10 targets were compared for visualization on OB-MRI and OB-CT by each of the three physicians. The majority of physicians (two or more) evaluated visualization on MRI as better for 71% of structures, worse for 10% of structures, and equivalent for 14% of structures. 5% of structures were not visible on either. Physicians agreed unanimously for 74% and in majority for > 99% of structures. Targets were better visualized on MRI in 4/10 cases, and never on OB-CT. CONCLUSION: Low-field MR provides better anatomic visualization of many radiotherapy targets and most OARs as compared to OB-CT. Further studies with OB-MRI should be pursued.


Asunto(s)
Imagen por Resonancia Magnética , Radioterapia Guiada por Imagen/métodos , Tomografía Computarizada por Rayos X , Neoplasias Abdominales/patología , Neoplasias Abdominales/radioterapia , Neoplasias de Cabeza y Cuello/patología , Neoplasias de Cabeza y Cuello/radioterapia , Humanos , Variaciones Dependientes del Observador , Neoplasias Pélvicas/patología , Neoplasias Pélvicas/radioterapia , Neoplasias Torácicas/patología , Neoplasias Torácicas/radioterapia
10.
Med Phys ; 51(6): 3822-3849, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38648857

RESUMEN

Use of magnetic resonance (MR) imaging in radiation therapy has increased substantially in recent years as more radiotherapy centers are having MR simulators installed, requesting more time on clinical diagnostic MR systems, or even treating with combination MR linear accelerator (MR-linac) systems. With this increased use, to ensure the most accurate integration of images into radiotherapy (RT), RT immobilization devices and accessories must be able to be used safely in the MR environment and produce minimal perturbations. The determination of the safety profile and considerations often falls to the medical physicist or other support staff members who at a minimum should be a Level 2 personnel as per the ACR. The purpose of this guidance document will be to help guide the user in making determinations on MR Safety labeling (i.e., MR Safe, Conditional, or Unsafe) including standard testing, and verification of image quality, when using RT immobilization devices and accessories in an MR environment.


Asunto(s)
Inmovilización , Imagen por Resonancia Magnética , Imagen por Resonancia Magnética/instrumentación , Humanos , Inmovilización/instrumentación , Radioterapia Guiada por Imagen/instrumentación
11.
Med Phys ; 49(6): 3683-3691, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35394074

RESUMEN

PURPOSE: The purpose of this work is to evaluate the scaled computed tomography (CT) number accuracy of an artificial 120 kV reconstruction technique based on phantom experiments in the context of radiation therapy planning. METHODS: An abdomen-shaped electron density phantom was scanned on a clinical CT scanner capable of artificial 120 kV reconstruction using different tube potentials from 70 to 150 kV. A series of tissue-equivalent phantom inserts (lung, adipose, breast, solid water, liver, inner bone, 30%/50% CaCO3 , cortical bone) were placed inside the phantom. Images were reconstructed using a conventional quantitative reconstruction kernel as well as the artificial 120 kV reconstruction kernel. Scaled CT numbers of inserts were measured from images acquired at different kVs and compared with those acquired at 120 kV, which were deemed as the ground truth. The relative error was quantified as the percentage deviation of scaled CT numbers acquired at different tube potentials from their ground truth values acquired at 120 kV. RESULTS: Scaled CT numbers measured from images reconstructed using the conventional reconstruction demonstrated a strong kV-dependence. The relative error in scaled CT numbers ranged from 0.6% (liver insert) to 31.1% (cortical bone insert). The artificial 120 kV reconstruction reduced the kV dependence, especially for bone tissues. The relative error in scaled CT number was reduced to 0.4% (liver insert) and 2.6% (30% CaCO3 insert) using this technique. When tube potential selection was limited to the range of 90 to 150 kV, the relative error was further restrained to <1.2% for all tissue types. CONCLUSION: Phantom results demonstrated that using the artificial 120 kV technique, it was feasible to acquire raw projection data at the desired tube potential and then reconstruct images with scaled CT numbers comparable to those obtained directly at 120 kV. In radiotherapy applications, this technique may allow optimization of tube potential without complicating clinical workflow by eliminating the necessity of maintaining multiple sets of CT calibration curves.


Asunto(s)
Tomografía Computarizada por Rayos X , Calibración , Fantasmas de Imagen , Dosis de Radiación , Tomógrafos Computarizados por Rayos X , Tomografía Computarizada por Rayos X/métodos
13.
J Magn Reson Imaging ; 33(3): 742-7, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21563260

RESUMEN

PURPOSE: To improve the effectiveness of the UNFOLD technique in removing aliasing artifacts by detrending temporal phase drift in each voxel before the implementation of the UNFOLD technique. This is because linear and quadratic phase trends in temporal signal can shift and broaden aliasing peaks in the spectrum and cause the removal of aliasing artifacts by spectral filtering to be insufficient or even fail when minimal filtering of the spectrum is used. MATERIALS AND METHODS: A functional magnetic resonance imaging (fMRI) study with a visual stimulus was performed on normal subjects to test the hypothesis. A 2D spiral-in/out sequence was used to acquire k-space data. Undersampled k-space trajectories were used to improve temporal resolution. Aliasing artifacts were removed by the UNFOLD technique. For comparison, two image sets, with and without phase trends removal, were obtained from each set of functional data. RESULTS: After detrending temporal phase drift, residual aliasing artifacts that were not suppressed by the standard UNFOLD technique could be successfully removed. Better image quality, temporal stability, and activation maps could be achieved by the proposed method. CONCLUSION: The proposed method can improve the effectiveness of the UNFOLD technique in removing aliasing artifacts when spectral filtering is kept minimal to preserve temporal resolution.


Asunto(s)
Diagnóstico por Imagen/métodos , Imagen por Resonancia Magnética/métodos , Algoritmos , Artefactos , Diseño de Equipo , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Modelos Estadísticos , Marcadores de Spin , Factores de Tiempo
14.
J Healthc Eng ; 2021: 2911025, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34630979

RESUMEN

We study the rehabilitation training of damaged parts of ice and snow sports clock and ensure the physical safety of athletes. The results show that the RBF neural network updates the center, weight, and width of the radial basis function, and the predicted maximum compliance is 99%, and the minimum compliance is 93%. After many analysis times, the prediction results show that the difference between the predicted degree of conformity and the actual results is less than 8%. The RBF neural network is trained according to the risk database of sports injury, and the RBF neural network will output corresponding values to realize sports injury estimation. The experimental results show that the designed model has high precision and efficiency.


Asunto(s)
Macrodatos , Deportes , Atletas , Simulación por Computador , Humanos , Redes Neurales de la Computación
15.
Med Phys ; 48(11): 7512-7525, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34519357

RESUMEN

PURPOSE: To validate breast tissue expander metallic port (MP) models in a commercial treatment planning system (TPS) in proton pencil beam scanning (PBS) treatments for breast cancer patients with breast tissue expanders. METHODS AND MATERIALS: Three types of MPs taken out of a Mentor CPX4, a Natrelle 133, and a PMT Integra breast tissue expanders and a 650 cc saline filled Mentor CPX4 expander were placed on top of acrylic slabs, and scanned using a Siemens Somatom Definition AS Open RT CT scanner. Structure templates for each of the MPs were designed within Eclipse TPS. The CT numbers for the metallic parts were overridden to reflect measured or calculated relative proton stopping powers (RPSPs). Mock targets were contoured in acrylic to represent postmastectomy chest-wall radiation therapy (PMRT) targets. Plans with different beam incident angles were optimized using the Eclipse TPS to deliver uniform prescription dose to the target using Hitachi Probeat-V PBS beams. Eclipse calculated doses and an in-house Monte Carlo (MC) code calculated doses were compared to the measured Gafchromic EBT3 film doses in acrylic. RESULTS: TPS/MC and film dose comparison results showed that (1) 3%/2 mm/10% threshold Gamma pass rates were better than 90.8% in the acrylic target region for all plans; (2) comparing TPS and film doses for the individual beam plans in the MP dose shadow areas, the area with dose difference above 5% ([ΔA] 5%) ranged from 1.1 to 5.0 cm2 , and the maximum dose difference ([ΔD] 0.01 cm2 ) ranged from 12.5% to 25.0%; (3) comparing MC and film doses for the individual beam plans in the MP dose shadow areas, the (ΔA) 5% varied from 1.1 to 2.9 cm2 and (ΔD) 0.01 cm2 varied from 8.5% to 24.2%; (4) for a plan composed of three individual beams treating through the Mentor CPX4 expander, the TPS (ΔA) 5% was less than 0.13 cm2 , and the (ΔD) 0.01 cm2 was less than 6% in the MP dose shadow areas. CONCLUSIONS: It is feasible to treat patients with tissue expanders using multiple PBS beams using a structure template with CT number overridden to represent the measured/calculated RPSP for MPs for PBS treatment planning. MC dose was more accurate than analytical dose in the areas with high dose gradient caused by the density heterogeneity of the breast tissue expander MPs.


Asunto(s)
Neoplasias de la Mama , Terapia de Protones , Algoritmos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/cirugía , Femenino , Humanos , Mastectomía , Método de Montecarlo , Fantasmas de Imagen , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Dispositivos de Expansión Tisular
16.
Med Phys ; 48(7): e636-e670, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33386620

RESUMEN

The use of dedicated magnetic resonance simulation (MR-SIM) platforms in Radiation Oncology has expanded rapidly, introducing new equipment and functionality with the overall goal of improving the accuracy of radiation treatment planning. However, this emerging technology presents a new set of challenges that need to be addressed for safe and effective MR-SIM implementation. The major objectives of this report are to provide recommendations for commercially available MR simulators, including initial equipment selection, siting, acceptance testing, quality assurance, optimization of dedicated radiation therapy specific MR-SIM workflows, patient-specific considerations, safety, and staffing. Major contributions include guidance on motion and distortion management as well as MRI coil configurations to accommodate patients immobilized in the treatment position. Examples of optimized protocols and checklists for QA programs are provided. While the recommendations provided here are minimum requirements, emerging areas and unmet needs are also highlighted for future development.


Asunto(s)
Oncología por Radiación , Radioterapia Guiada por Imagen , Simulación por Computador , Humanos , Imagen por Resonancia Magnética , Planificación de la Radioterapia Asistida por Computador
17.
Med Phys ; 48(11): 6634-6641, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34608990

RESUMEN

PURPOSE: To measure diode sensitivity degradation (DSD) induced by cumulative proton dose delivered to a commercial daily quality assurance (QA) device. METHODS: At our institution, six Daily QA 3 (DQA3, Sun Nuclear Corporation, Melbourne, FL, USA) devices have been used for daily proton pencil beam scanning QA in four proton gantry rooms over a span of 4 years. DQA3 diode counts were cross-calibrated using a homogenous field with a known dose of 1 Gy. The DSD rate (ΔR%/100 Gy) was calculated using linear regression on time-series plots of diode counts and an estimate of cumulative dose per year based on the cross-calibration. The effect of DSD on daily QA spot position measurements was quantified by converting DSD to baseline spot position shift. RESULTS: The average dose delivered to the four inner DQA3 diodes was 104 ± 5 Gy/year, and the rate of DSD was -5.1% ± 1.0/100 Gy with the exception of one DQA3 device that had a significantly higher rate of DSD (-12%/100 Gy). The R2 s of the linear fit to time-series plots were between 0.92 and 0.98. The DSD rates were not constant but decreases with accumulated doses. The four center diodes, which received 40% of the cumulative dose received by inner diodes, had a DSD rate of -7.2% ± 0.9/100 Gy. For our daily QA program, 1 year of DSD was equivalent to a 0.2 mm shift in spot position. CONCLUSIONS: The DSD rate of DQA3 diodes determined by long-term proton daily QA data was about -5%/100 Gy, which is more than 10 times greater than the reported DSD rate from photon irradiation. DQA3 diodes may be used for daily proton QA programs, provided that they are recalibrated at an appropriate frequency that should be determined specifically for different daily QA programs.


Asunto(s)
Terapia de Protones , Protones , Garantía de la Calidad de Atención de Salud , Radiación Ionizante , Radiometría , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
18.
Radiat Oncol ; 16(1): 139, 2021 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-34321029

RESUMEN

BACKGROUND: Mega-voltage fan-beam Computed Tomography (MV-FBCT) holds potential in accurate determination of relative electron density (RED) and proton stopping power ratio (SPR) but is not widely available. OBJECTIVE: To demonstrate the feasibility of MV-FBCT using a medical linear accelerator (LINAC) with a 2.5 MV imaging beam, an electronic portal imaging device (EPID) and multileaf collimators (MLCs). METHODS: MLCs were used to collimate MV beam along z direction to enable a 1 cm width fan-beam. Projection data were acquired within one gantry rotation and preprocessed with in-house developed artifact correction algorithms before the reconstruction. MV-FBCT data were acquired at two dose levels: 30 and 60 monitor units (MUs). A Catphan 604 phantom was used to evaluate basic image quality. A head-sized CIRS phantom with three configurations of tissue-mimicking inserts was scanned and MV-FBCT Hounsfield unit (HU) to RED calibration was established for each insert configuration using linear regression. The determination coefficient ([Formula: see text]) was used to gauge the accuracy of HU-RED calibration. Results were compared with baseline single-energy kilo-voltage treatment planning CT (TP-CT) HU-RED calibration which represented the current standard clinical practice. RESULTS: The in-house artifact correction algorithms effectively suppressed ring artifact, cupping artifact, and CT number bias in MV-FBCT. Compared to TP-CT, MV-FBCT was able to improve the prediction accuracy of the HU-RED calibration curve for all three configurations of insert materials, with [Formula: see text] > 0.9994 and [Formula: see text] < 0.9990 for MV-FBCT and TP-CT HU-RED calibration curves of soft-tissue inserts, respectively. The measured mean CT numbers of blood-iodine mixture inserts in TP-CT drastically deviated from the fitted values but not in MV-FBCT. Reducing the radiation level from 60 to 30 MU did not decrease the prediction accuracy of the MV-FBCT HU-RED calibration curve. CONCLUSION: We demonstrated the feasibility of MV-FBCT and its potential in providing more accurate RED estimation.


Asunto(s)
Algoritmos , Neoplasias/radioterapia , Aceleradores de Partículas/instrumentación , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Tomografía Computarizada por Rayos X/métodos , Artefactos , Calibración , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Dosificación Radioterapéutica
19.
Med Phys ; 48(7): e697-e732, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33864283

RESUMEN

PURPOSE: A magnetic resonance (MR) biologic marker (biomarker) is a measurable quantitative characteristic that is an indicator of normal biological and pathogenetic processes or a response to therapeutic intervention derived from the MR imaging process. There is significant potential for MR biomarkers to facilitate personalized approaches to cancer care through more precise disease targeting by quantifying normal versus pathologic tissue function as well as toxicity to both radiation and chemotherapy. Both of which have the potential to increase the therapeutic ratio and provide earlier, more accurate monitoring of treatment response. The ongoing integration of MR into routine clinical radiation therapy (RT) planning and the development of MR guided radiation therapy systems is providing new opportunities for MR biomarkers to personalize and improve clinical outcomes. Their appropriate use, however, must be based on knowledge of the physical origin of the biomarker signal, the relationship to the underlying biological processes, and their strengths and limitations. The purpose of this report is to provide an educational resource describing MR biomarkers, the techniques used to quantify them, their strengths and weakness within the context of their application to radiation oncology so as to ensure their appropriate use and application within this field.


Asunto(s)
Oncología por Radiación , Biomarcadores , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética
20.
Adv Radiat Oncol ; 6(4): 100675, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34409199

RESUMEN

PURPOSE: Our purpose was to assess the safety and efficacy of intensity modulated proton therapy (IMPT) for the treatment of hepatocellular carcinoma (HCC). METHODS AND MATERIALS: A retrospective review was conducted on all patients who were treated with IMPT for HCC with curative intent from June 2015 to December 2018. All patients had fiducials placed before treatment. Inverse treatment planning used robust optimization with 2 to 3 beams. The majority of patients were treated in 15 fractions (n = 30, 81%, 52.5-67.5 Gy, relative biological effectiveness), whereas the remainder were treated in 5 fractions (n = 7, 19%, 37.5-50 Gy, relative biological effectiveness). Daily image guidance consisted of orthogonal kilovoltage x-rays and use of a 6° of freedom robotic couch. Outcomes (local control, progression free survival, and overall survival) were determined using Kaplan-Meier methods. RESULTS: Thirty-seven patients were included. The median follow-up for living patients was 21 months (Q1-Q3, 17-30 months). Pretreatment Child-Pugh score was A5-6 in 70% of patients and B7-9 in 30% of patients. Nineteen patients had prior liver directed therapy for HCC before IMPT. Eight patients (22%) required a replan during treatment, most commonly due to inadequate clinical target volume coverage. One patient (3%) experienced a grade 3 acute toxicity (pain) with no recorded grade 4 or 5 toxicities. An increase in Child-Pugh score by ≥ 2 within 3 months of treatment was observed in 6 patients (16%). At 1 year, local control was 94%, intrahepatic control was 54%, progression free survival was 35%, and overall survival was 78%. CONCLUSIONS: IMPT is safe and feasible for treatment of HCC.