Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
BMC Med Imaging ; 23(1): 122, 2023 09 11.
Artículo en Inglés | MEDLINE | ID: mdl-37697248

RESUMEN

OBJECTIVES: To compare the inter-modality consistency and diagnostic performances of the contrast-enhanced ultrasound (CEUS) Liver Imaging Reporting and Data System (LI-RADS) and contrast-enhanced computed tomography (CECT) LI-RADS in patients at risk for hepatocellular carcinoma (HCC), so as to help clinicians to select a more appropriate modality to follow the focal liver lesions (FLLs). METHODS: This retrospective study included untreated 277 FLLs from 247 patients who underwent both CEUS and CECT within 1 month. The ultrasound contrast medium used was SonoVue. FLL categories were independently assigned by two ultrasound physicians and two radiologists using CEUS LI-RADS v2017 and CECT LI-RADS v2018, respectively. The diagnostic performances of CEUS and CECT LI-RADS were evaluated using sensitivity, specificity, positive predictive value (PPV), and negative predictive value. Cohen's Kappa was employed to evaluate the concordance of the LI-RADS category. RESULTS: The inter-modality consistency for CEUS and CECT LI-RADS was 0.31 (p < 0.001). HCC was more frequently observed in CECT LR-3 and LR-4 hepatic lesions than in CEUS (7.3% vs. 19.5%, p < 0.001). The specificity and PPV of CEUS and CECT LR-5 for the diagnosis of HCC were 89.5%, 95.0%, and 82.5%, 94.4%, respectively. The sensitivity of CEUS LR-5 + LR-M for the diagnosis of hepatic malignancies was higher than that of CECT (93.7% vs. 82.7%, p < 0.001). The specificity and PPV of CEUS LR-M for the diagnosis of non-HCC malignancies were lower than those of CECT (59.7% vs. 95.5%, p < 0.001; 23.4% vs. 70.3%, p < 0.001). CONCLUSIONS: The inter-modality consistency between the CEUS and CECT LI-RADS categories is fair. CEUS LI-RADS was more sensitive than CECT LI-RADS in terms of identifying hepatic malignancies, but weaker in terms of separating HCC from non-HCC malignancies.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagen , Estudios Retrospectivos , Neoplasias Hepáticas/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Medios de Contraste
2.
J Ultrasound Med ; 42(10): 2403-2413, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37269201

RESUMEN

OBJECTIVE: To assess the diagnostic performance of the contrast-enhanced ultrasound liver imaging reporting and data system (CEUS LI-RADS) version 2017 for small hepatic lesions of ≤3 cm before and after changing the LR-M criteria. METHODS: We retrospectively analyzed the CEUS examination of 179 patients who were at high risk of hepatocellular carcinoma (HCC) with focal hepatic lesions ≤3 cm (194 lesions in total) and evaluated the diagnostic capability of the American College of Radiology and modified CEUS LI-RADS algorithms. RESULTS: Revision of the early washout time to 45 seconds increased the sensitivity of LR-5 in predicting HCC (P = .004), with no significant decrease in specificity (P = .118). It also made better the specificity of LR-M in predicting non-HCC malignancies (P = .001), with no significant decrease in sensitivity (P = .094). However, using within 3 minutes as the criterion for marked washout time improved the LR-5 sensitivity (P < .001) but decreased its specificity (P = .009) in predicting HCC, whereas the specificity of LR-M in predicting non-HCC malignancies increased (P < .001), but the sensitivity decreased (P = .027). CONCLUSIONS: CEUS LI-RADS (v2017) is a valid method for predicting HCC risk in high-risk patients. The diagnostic performance of LR-5 and LR-M could boost when the early washout time is revised to 45 seconds.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Estudios Retrospectivos , Medios de Contraste , Imagen por Resonancia Magnética/métodos , Sensibilidad y Especificidad
3.
Nucleic Acids Res ; 47(D1): D181-D187, 2019 01 08.
Artículo en Inglés | MEDLINE | ID: mdl-30357353

RESUMEN

PIWI-interacting RNAs (piRNAs) are a class of small noncoding RNAs that guard animal genomes against mutation by silencing transposons. In addition, recent studies have reported that piRNAs silence various endogenous genes. Tens of thousands of distinct piRNAs made in animals do not pair well to transposons and currently the functions and targets of piRNAs are largely unexplored. piRTarBase provides a user-friendly interface to access both predicted and experimentally identified piRNA targeting sites in Caenorhabditis elegans. The user can input genes of interest and retrieve a list of piRNA targeting sites on the input genes. Alternatively, the user can input a piRNA and retrieve a list of its mRNA targets. Additionally, piRTarBase integrates published mRNA and small RNA sequencing data, which will help users identify biologically relevant targeting events. Importantly, our analyses suggest that the piRNA sites found by both predictive and experimental approaches are more likely to exhibit silencing effects on their targets than each method alone. Taken together, piRTarBase offers an integrative platform that will help users to identify functional piRNA target sites by evaluating various information. piRTarBase is freely available for academic use at http://cosbi6.ee.ncku.edu.tw/piRTarBase/.


Asunto(s)
Sitios de Unión , Bases de Datos Genéticas , Regulación de la Expresión Génica , Silenciador del Gen , Interferencia de ARN , ARN Mensajero/genética , ARN Interferente Pequeño/genética , Programas Informáticos , Navegador Web , Flujo de Trabajo
4.
Nucleic Acids Res ; 46(W1): W43-W48, 2018 07 02.
Artículo en Inglés | MEDLINE | ID: mdl-29897582

RESUMEN

pirScan is a web-based tool for identifying C. elegans piRNA-targeting sites within a given mRNA or spliced DNA sequence. The purpose of our tool is to allow C. elegans researchers to predict piRNA targeting sites and to avoid the persistent germline silencing of transgenes that has rendered many constructs unusable. pirScan fulfills this purpose by first enumerating the predicted piRNA-targeting sites present in an input sequence. This prediction can be exported in a tabular or graphical format. Subsequently, pirScan suggests silent mutations that can be introduced to the input sequence that would allow the modified transgene to avoid piRNA targeting. The user can customize the piRNA targeting stringency and the silent mutations that he/she wants to introduce into the sequence. The modified sequences can be re-submitted to be certain that any previously present piRNA-targeting sites are now absent and no new piRNA-targeting sites are accidentally generated. This revised sequence can finally be downloaded as a text file and/or visualized in a graphical format. pirScan is freely available for academic use at http://cosbi4.ee.ncku.edu.tw/pirScan/.


Asunto(s)
Caenorhabditis elegans/genética , Internet , ARN Interferente Pequeño/genética , Programas Informáticos , Animales , Biología Computacional/tendencias , ARN Interferente Pequeño/química
5.
J Nanosci Nanotechnol ; 18(4): 2823-2829, 2018 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-29442962

RESUMEN

This study utilized cathodic arc deposition technology to coat Ti-Al-N hard films on AISI 4340 alloy steel. Composition, morphology, and structure of the coatings were analyzed using EPMA, FESEM, XRD, and TEM. Both wear tests and polarization tests were conducted to determine the abrasion and corrosion properties of the steel before and after coating. The results showed that a specific (Ti, Al)N nanostructured multilayer was synthesized smoothly. The multilayer consisted of 10 nm-TiN and 15 nm-TiAlN interaction layers. The coating not only greatly reduced the friction coefficient of AISI 4340 alloy steel from 0.81 to 0.45, but also provided an effective improvement in corrosion resistance.

6.
Heliyon ; 10(4): e25989, 2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38390142

RESUMEN

Image-based gauging stations offer the potential for substantial enhancement in the monitoring networks of river water levels. Nonetheless, the majority of camera gauges fall short in delivering reliable and precise measurements because of the fluctuating appearance of water in the rivers over the course of the year. In this study, we introduce a method for measuring water levels in rivers using both the traditional continuous image subtraction (CIS) approach and a SegNet neural network based on deep learning computer vision. The historical images collected from on-site investigations were employed to train three neural networks (SegNet, U-Net, and FCN) in order to evaluate their effectiveness, overall performance, and reliability. The research findings demonstrated that the SegNet neural network outperformed the CIS method in accurately measuring water levels. The root mean square error (RMSE) between the water level measurements obtained by the SegNet neural network and the gauge station's readings ranged from 0.013 m to 0.066 m, with a high correlation coefficient of 0.998. Furthermore, the study revealed that the performance of the SegNet neural network in analyzing water levels in rivers improved with the inclusion of a larger number of images, diverse image categories, and higher image resolutions in the training dataset. These promising results emphasize the potential of deep learning computer vision technology, particularly the SegNet neural network, to enhance water level measurement in rivers. Notably, the quality and diversity of the training dataset play a crucial role in optimizing the network's performance. Overall, the application of this advanced technology holds great promise for advancing water level monitoring and management in river systems.

7.
Diabetol Metab Syndr ; 16(1): 78, 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38566188

RESUMEN

BACKGROUND: Insulin resistance is associated with the development of hypertension, whereas there were rare studies comparing various non-insulin based insulin resistance (NI-IR) indices for the possibility of hypertension among young and middle-aged adults. METHODS: This cross-sectional study included a total of 4,080 military personnel, aged 18-50 years, without antihypertensive medications therapy in 2014. All subjects received annual health examinations for blood pressure (BP) measurements. Stage I isolated diastolic hypertension (IDH) and isolated systolic hypertension (ISH) and combined hypertension were respectively defined as systolic BP (SBP) < 130 mmHg/diastolic BP (DBP) 80-89 mmHg, SBP 130-139 mmHg/DBP < 80 mmHg, and SBP 130-139 mmHg/DBP 80-89 mmHg. The cut-off values of stage II hypertension for SBP and DBP were 140-159 mmHg and 90-99 mmHg, respectively. Four NI-IR indices included the serum triglycerides (TG) to high-density lipoprotein cholesterol (HDL-C) ratio, TyG index, Metabolic Score for IR (METS-IR) and ZJU index which were defined according to their specific formula. Multiple logistic regression analysis with adjustments for age, sex, anthropometrics, substance use, kidney function, serum uric acid, atherogenic cholesterols and physical activity was performed to determine the associations. RESULTS: There were 1,024 subjects with hypertension (25.1%) in which 739 were stage I hypertension, and 285 were stage II hypertension. For total hypertension, there were an association with TyG and METS-IR indices [odds ratios (ORs) and 95% confidence intervals: 1.432 (1.215-1.688) and 1.553 (1.040-2.321), respectively]. For hypertension subtypes, TyG index was positively associated with overall, stage I, and stage II ISH [ORs: 1.447 (1.149-1.823), 1.317 (1.029-1.687), and 2.011 (1.351-2.994), respectively], while TG/HDL-C, METS-IR and ZJU indices were merely associated with stage II ISH [ORs: 1.053 (1.006-1.103), 3.001 (1.171-7.696) and 1.009 (1.000-1.017), respectively]. In addition, TyG and METS-IR indices were positively associated with stage II IDH [ORs: 1.813 (1.207-2.721) and 2.85 (1.080-7.520), respectively], and TyG index was also associated with combined hypertension [OR: 1.425 (1.007-1.833)]. CONCLUSION: Among young and middle-aged adults, insulin resistance assessed by the four NI-IR indices was positively associated with stage II ISH, while only TyG index had a significant association for both stage II IDH and combined hypertension.

8.
Abdom Radiol (NY) ; 49(5): 1432-1443, 2024 05.
Artículo en Inglés | MEDLINE | ID: mdl-38584190

RESUMEN

PURPOSE: To assess whether the diagnostic performance of Sonazoid contrast-enhanced ultrasound (SZUS) is non-inferior to that of SonoVue contrast-enhanced ultrasound (SVUS) in diagnosing hepatocellular carcinoma (HCC) in individuals with high risk. MATERIALS AND METHODS: This prospective study was conducted from October 2020 to May 2022 and included participants with a high risk of HCC who underwent SZUS and SVUS. All lesions were confirmed by clinical or pathological diagnosis. Each nodule was classified according to the Contrast-Enhanced Ultrasound Liver Imaging Reporting and Data System version 2017 (CEUS LI-RADS v2017) for SVUS and SZUS and the modified CEUS LI-RADS (using Kupffer phase defect instead of late and mild washout) for SZUS. The diagnostic performance of both two modalities for all observations was compared. Analysis of the vascular phase and Kupffer phase imaging characteristics of CEUS was performed. RESULTS: One hundred and fifteen focal liver lesions from 113 patients (94 HCCs, 12 non-HCC malignancies, and 9 benign lesions) were analysed. According to CEUS LI-RADS (v2017), SVUS and SZUS showed similar sensitivity (71.3% vs. 72.3%) and specificity (85.7% vs. 81.0%) in HCC diagnosis. However, the modified CEUS LI-RADS did not significantly improve the diagnostic efficacy of Sonazoid compared to CEUS LI-RADS v2017, having equivalent sensitivity (73.4% vs. 72.3%) and specificity (81.0% vs. 81.0%). The agreement between SVUS and SZUS for all observations was 0.610 (95% CI 0.475, 0.745), while for HCCs it was 0.452 (95% CI 0.257, 0.647). CONCLUSION: Using LI-RADS v2017, SZUS and SVUS showed non-inferior efficacy in evaluating HCC lesions. In addition, adding Kupffer phase defects to SZUS does not notably improve its diagnostic efficacy.


Asunto(s)
Carcinoma Hepatocelular , Medios de Contraste , Compuestos Férricos , Hierro , Neoplasias Hepáticas , Óxidos , Ultrasonografía , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Carcinoma Hepatocelular/diagnóstico por imagen , Masculino , Estudios Prospectivos , Femenino , Ultrasonografía/métodos , Persona de Mediana Edad , Anciano , Fosfolípidos , Aumento de la Imagen/métodos , Sensibilidad y Especificidad , Adulto , Hexafluoruro de Azufre
9.
Eur J Radiol ; 154: 110415, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35738166

RESUMEN

PURPOSE: To analyze the contrast-enhanced ultrasound (CEUS) manifestations of combined hepatocellular-cholangiocarcinoma (CHC) and to investigate the diagnostic value of the 2017 version of the CEUS Liver Imaging Reporting and Data System (LI-RADS) and serum tumor markers in CHC. METHODS: A total of 66 pathologically confirmed CHC nodules were retrospectively analyzed. We summarized the CEUS manifestations of CHC and analyzed the relationship between serum tumor markers and the enhancement pattern of CHC. We also classified CHC according to CEUS LI-RADS criteria. The Kappa test was used to assess the interreader agreement of CEUS LI-RADS between radiologists. RESULT: According to the results, 52 of 62 (83.9%) patients had elevated alpha-fetoprotein (AFP), 19 of 61 (31.1%) had elevated carbohydrate antigen 199 (CA 199), and 13 of 61 (21.3%) had both elevated AFP and CA 199. Of the 66 CHC nodules, 64 (97.0%) were identified as malignant lesions by CEUS, 13 (19.7%) showed a hepatocellular carcinoma-like enhancement pattern, and 21 (31.8%) showed a cholangiocarcinoma-like enhancement pattern. For the CEUS LI-RADS categories, 39 of 53 (73.6%) CHC nodules were classified as LR-M, 12 (22.6%) were classified as LR-5, and 2 (3.8%) were classified as LR-4. The interreader agreement for the LI-RADS categories was 0.60. CONCLUSIONS: Although CHC lacks specific CEUS features, CEUS LI-RADS and serum tumor markers can be useful tools for reducing the misdiagnosis of CHC. In addition, due to the relative complexity of the CEUS features involved in CHC, it is necessary for beginning radiologists to learn more about CEUS features.


Asunto(s)
Neoplasias de los Conductos Biliares , Carcinoma Hepatocelular , Colangiocarcinoma , Neoplasias Hepáticas , Neoplasias de los Conductos Biliares/diagnóstico por imagen , Neoplasias de los Conductos Biliares/patología , Conductos Biliares Intrahepáticos/patología , Biomarcadores de Tumor , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/patología , Colangiocarcinoma/diagnóstico por imagen , Colangiocarcinoma/patología , Medios de Contraste , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Imagen por Resonancia Magnética/métodos , Estudios Retrospectivos , alfa-Fetoproteínas
10.
Artif Intell Med ; 125: 102244, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35241257

RESUMEN

The detection of the most common type of liver tumor, that is, hepatocellular carcinoma (HCC), is one essential step to liver pathology image analysis. In liver tissue, common cell change phenomena such as apoptosis, necrosis, and steatosis are similar in tumor and benign tissue. Hence, the detection of HCC may fail when the patches covered only limited tissue region without enough neighboring cell structure information. To address this problem, a Feature Aligned Multi-Scale Convolutional Network (FA-MSCN) architecture is proposed in this paper for automatic liver tumor detection based on whole slide images (WSI). The proposed network integrates the features obtained at different magnification levels to improve the detection performance by referencing more neighboring information. The FA-MSCN consists of two parallel convolutional networks in which one would extract high-resolution features and the other would extract low-resolution features by atrous convolution. The low-resolution features then go through central cropping, upsampling, and concatenation with high-resolution features for final classification. The experimental results demonstrated that Multi-Scale Convolutional Network (MSCN) improves the detection performance compared to Single-Scale Convolutional Network (SSCN), and that the FA-MSCN is superior to both SSCN and MSCN, demonstrating on HCC detection.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Carcinoma Hepatocelular/diagnóstico , Humanos , Procesamiento de Imagen Asistido por Computador , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Redes Neurales de la Computación
11.
Science ; 359(6375): 587-592, 2018 02 02.
Artículo en Inglés | MEDLINE | ID: mdl-29420292

RESUMEN

Piwi-interacting RNAs (piRNAs) silence transposons to safeguard genome integrity in animals. However, the functions of the many piRNAs that do not map to transposons remain unknown. Here, we show that piRNA targeting in Caenorhabditis elegans can tolerate a few mismatches but prefer perfect pairing at the seed region. The broad targeting capacity of piRNAs underlies the germline silencing of transgenes in C. elegans Transgenes engineered to avoid piRNA recognition are stably expressed. Many endogenous germline-expressed genes also contain predicted piRNA targeting sites, and periodic An/Tn clusters (PATCs) are an intrinsic signal that provides resistance to piRNA silencing. Together, our study revealed the piRNA targeting rules and highlights a distinct strategy that C. elegans uses to distinguish endogenous from foreign nucleic acids.


Asunto(s)
Caenorhabditis elegans/genética , Silenciador del Gen , Marcación de Gen/métodos , ARN de Helminto/genética , ARN Interferente Pequeño/genética , Animales , Proteína Quinasa CDC2/genética , Proteínas Fluorescentes Verdes/genética , Transgenes
12.
Asia Pac Psychiatry ; 6(3): 319-25, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24357621

RESUMEN

INTRODUCTION: The aim of this study is to investigate the association among depressive disorder, adjustment disorder, sleep disturbance, and suicidal ideation in Taiwanese adolescent. METHODS: We recruited 607 students (grades 5-9) to fill out the investigation of basic data and sleep disturbance. Psychiatrists then used the Mini International Neuropsychiatric Interview-Kid to interview these students to assess their suicidal ideation and psychiatric diagnosis. Multiple logistic regression with forward conditionals was used to find the risk factors for multivariate analysis. RESULTS: Female, age, depressive disorder, adjustment disorder, and poor sleep all contributed to adolescent suicidal ideation in univariate analysis. However, poor sleep became non-significant under the control of depressive disorder and adjustment disorder. DISCUSSION: We found that both depressive disorder and adjustment disorder play important roles in sleep and adolescent suicidal ideation. After controlling both depressive disorder and adjustment disorder, sleep disturbance was no longer a risk of adolescent suicidal ideation. We also confirm the indirect influence of sleep on suicidal ideation in adolescent.


Asunto(s)
Trastornos de Adaptación/epidemiología , Comorbilidad , Trastorno Depresivo/epidemiología , Trastornos del Sueño-Vigilia/epidemiología , Ideación Suicida , Adolescente , Niño , Femenino , Humanos , Masculino , Factores de Riesgo , Taiwán/epidemiología
13.
J Chin Med Assoc ; 74(8): 363-8, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21872817

RESUMEN

BACKGROUND: Depression generates a remarkable disease burden. Early onset of depression in young people is associated with a poor prognosis. This has precipitated developing a screening instrument for early detection of depression in Taiwan adolescents. METHODS: We recruited 662 junior high school students who completed the Screening Test for Depression (STD) designed using diagnostic and statistical manual-IV diagnostic criteria of major depressive disorder for assessing depressive symptoms. The students were then interviewed by psychiatrists who used the Mini International Neuropsychiatric Interview-Kid to verify the validity of the soon-to-be-developed Rapid STD (RSTD). Multiple logistic regression analysis of the STD results was used to extract items for the RSTD. RESULTS: We extracted four items for the RSTD: "insomnia or hypersomnia", "recurrent thoughts of death or recurrent suicidal ideation", "feelings of worthlessness or excessive or inappropriate guilt", and "psychomotor agitation or retardation". Any two of the first three yielded the best-balanced algorithm for major depressive disorder, which had a sensitivity of 75.0%, specificity of 92.9%, positive predictive value of 28.6%, and negative predictive value of 99.0%. Any two of the four yielded the best-balanced algorithm for depressive disorders, which had a sensitivity of 71.4%, specificity of 92.0%, the positive predictive value of 33.3%, and the negative predictive value of 98.3%. CONCLUSION: The RSTD, a 4-item tool for junior high school children, can be easily used to assess fluctuating risks of major depressive disorder and depressive disorders at any time.


Asunto(s)
Trastorno Depresivo Mayor/diagnóstico , Trastorno Depresivo/diagnóstico , Adolescente , Femenino , Humanos , Modelos Logísticos , Masculino , Curva ROC , Encuestas y Cuestionarios , Factores de Tiempo
14.
Int J Psychiatry Clin Pract ; 13(4): 278-84, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-24916937

RESUMEN

Objectives. To validate the Schizophrenia Quality of Life Scale Revision 4 (SQLS-R4) Chinese version with factor analysis. We also investigated factors influencing quality of life results. Method. One hundred patients with schizophrenia participated in this study. Experienced psychiatrists evaluated each patient's current psychological condition to assure intact judgment. Participants then filled out the quality of life questionnaire, SQLS-R4. We used principal component analysis to analyze SQLS-R4 with oblique rotation. We also collected demographic data, another subjective and objective quality of life questionnaire, and information about the functional status of the participants at the same time. Multiple linear regression was used to analyze collected factors which may influence the quality of life of schizophrenic patients. Results. We extracted seven factors that explained a 68.1% variance in the patients' quality of life. The factors were relationships with others, loneliness, exhaustion, depressed thinking, somatic concerns, vitality, and worry. Conclusion. We found that the SQLS-R4 factor analysis provided insights into the structure of the quality of life of patients with schizophrenia. We also found that subjective social participation, subjective health, and depression were quality-of-life-related factors. Whether other factors influence the quality of life in patients with schizophrenia requires further investigation.

15.
Qual Life Res ; 16(9): 1533-8, 2007 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17891512

RESUMEN

We tested the reliability, sensitivity, and validity of a Chinese translation of the Schizophrenia Quality of Life Scale Revision 4 (SQLS-R4). One hundred Taiwanese individuals with schizophrenia were recruited. The internal consistency reliability was satisfactory for both the psychosocial and vitality domains (Cronbach's alpha = 0.92, 0.84). The test-retest reliability was also high (psychosocial: ICC = 0.84, vitality: ICC = 0.84) for those individuals whose psychological conditions remained stable between the two-week interval. However, the responsiveness coefficient for those with considerable changes in psychological conditions ranged from very small to moderate, suggesting either low responsiveness for the vitality domain or a complex relationship between the change of psychological conditions and quality of life, and the need to estimate responsiveness more conclusively in a future intervention study. The convergent validity was supported by moderate-to-large correlations between domains measuring related constructs of the SQLS-R4 and SF-36 (r = -0.65 to -0.67). Overall, the results of this study provide preliminary evidence for the reliability and validity of the SQLS-R4 used in Taiwanese individuals with schizophrenia. This study provides a common ground for international researchers to understand quality of life in Taiwanese patients with schizophrenia.


Asunto(s)
Psicometría/instrumentación , Calidad de Vida , Psicología del Esquizofrénico , Perfil de Impacto de Enfermedad , Encuestas y Cuestionarios/normas , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Taiwán , Traducciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA