1.
AJR Am J Roentgenol ; 222(2): e2330154, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-37966036

RESUMEN

BACKGROUND. Dual-energy CT pulmonary angiography (CTPA) with energy-integrating detector (EID) technology is limited by the inability to use high-pitch technique. OBJECTIVE. The purpose of this study was to compare the image quality of anatomic images and iodine maps between high-pitch photon-counting detector (PCD) CTPA and dual-energy EID CTPA. METHODS. This prospective study included 117 patients (70 men and 47 women; median age, 65 years) who underwent CTPA to evaluate for pulmonary embolism between March 2022 and November 2022. Fifty-eight patients were randomized to undergo PCD CTPA (pitch, 2.0), and 59 were randomized to undergo EID CTPA (pitch, 0.55). For each examination, 120-kV polychromatic images, 60-keV virtual monogenetic images (VMIs), and iodine maps were reconstructed. One radiologist measured CNR and SNR. Three radiologists independently assessed subjective image quality (on a scale of 1-4, with a score of 1 denoting highest quality). Radiation dose was recorded. RESULTS. SNR and CNR were higher for PCD CTPA than for EID CTPA for polychromatic images and VMIs, for all assessed vessels other than the left upper lobe artery. For example, for PCD CTPA versus EID CTPA, the right lower lobe artery on polychromatic images had an SNR of 34.5 versus 28.0 (p = .003) and a CNR of 29.2 versus 24.4 (p = .001), and on VMIs it had an SNR of 43.2 versus 32.7 (p = .005) and a CNR of 37.4 versus 29.3 (p = .002). For both scanners for readers 1 and 2, the median image quality score for polychromatic images and VMIs was 1, although distributions indicated significantly better scores for PCD CTPA than for EID CTPA for polychromatic images for reader 1 (p = .02) and reader 2 (p = .005) and for VMIs for reader 1 (p = .001) and reader 2 (p = .006). The image quality of anatomic image sets was not different between PCD CTPA and EID CTPA for reader 3 (p > .05). The image quality of iodine maps was not different between PCD CTPA and EID CTPA for any reader (p > .05). For PCD CTPA versus EID CTPA, the CTDIvol was 3.9 versus 4.5 mGy (p = .03), and the DLP was 123.5 mGy × cm versus 157.0 mGy × cm (p < .001). CONCLUSION. High-pitch PCD CTPA provided anatomic images with better subjective and objective image quality versus dual-energy EID CTPA, with lower radiation dose. Iodine maps showed no significant difference in image quality between scanners. CLINICAL IMPACT. CTPA may benefit from the PCD CT technique.


Asunto(s)
Yodo , Masculino , Humanos , Femenino , Anciano , Estudios Prospectivos , Fotones , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Dosis de Radiación
2.
BMC Med Imaging ; 24(1): 49, 2024 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-38395772

RESUMEN

PURPOSE: Unenhanced abdominal CT constitutes the diagnostic standard of care in suspected urolithiasis. Aiming to identify potential for radiation dose reduction in this frequent imaging task, this experimental study compares the effect of spectral shaping and tube voltage modulation on image quality. METHODS: Using a third-generation dual-source CT, eight cadaveric specimens were scanned with varying tube voltage settings with and without tin filter application (Sn 150, Sn 100, 120, 100, and 80 kVp) at three dose levels (3 mGy: standard; 1 mGy: low; 0.5 mGy: ultralow). Image quality was assessed quantitatively by calculation of signal-to-noise ratios (SNR) for various tissues (spleen, kidney, trabecular bone, fat) and subjectively by three independent radiologists based on a seven-point rating scale (7 = excellent; 1 = very poor). RESULTS: Irrespective of dose level, Sn 100 kVp resulted in the highest SNR of all tube voltage settings. In direct comparison to Sn 150 kVp, superior SNR was ascertained for spleen (p ≤ 0.004) and kidney tissue (p ≤ 0.009). In ultralow-dose scans, subjective image quality of Sn 100 kVp (median score 3; interquartile range 3-3) was higher compared with conventional imaging at 120 kVp (2; 2-2), 100 kVp (1; 1-2), and 80 kVp (1; 1-1) (all p < 0.001). Indicated by an intraclass correlation coefficient of 0.945 (95% confidence interval: 0.927-0.960), interrater reliability was excellent. CONCLUSIONS: In abdominal CT with maximised dose reduction, tin prefiltration at 100 kVp allows for superior image quality over Sn 150 kVp and conventional imaging without spectral shaping.


Asunto(s)
Estaño , Tomografía Computarizada por Rayos X , Humanos , Reproducibilidad de los Resultados , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Abdomen/diagnóstico por imagen
3.
Radiology ; 306(3): e221200, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36346312

RESUMEN

Background Posttraumatic CT imaging of the elbow can be challenging when patient mobility is limited. Gantry-free cone-beam CT (CBCT) with a twin robotic radiography system offers greater degrees of positioning freedom for three-dimensional elbow scans over gantry-based multidetector CT (MDCT), but studies analyzing their clinical value remain lacking. Purpose To investigate the diagnostic performance of gantry-free CBCT versus two-dimensional radiography in adults and children with acute elbow trauma. Materials and Methods In a retrospective study, consecutive patients with elbow trauma and positioning difficulty in a gantry-based MDCT who underwent three-dimensional elbow imaging with a gantry-free CBCT after radiography were enrolled between January 2021 and April 2022 at a tertiary care university hospital. Imaging data sets were independently analyzed for fracture presence, articular involvement, and multi-fragment injuries by three radiologists. Diagnostic performance was calculated individually with surgical reports serving as the reference standard. Differences between radiography and CBCT were compared with the McNemar test. Diagnostic confidence was estimated subjectively by each reader, and results were compared with the Wilcoxon signed-rank test. Results Elbow examinations of 23 adults and children (mean age ± SD, 49 years ± 23; seven women) were included with individual assessment of humerus, radius, and ulna (69 bones; 36 fractured). Multi-fragmentary fracture patterns and involvement of articular surfaces were ascertained in 28 and 30 bones, respectively. CBCT allowed for similar or higher sensitivity compared with radiography in the assessment of fractures (range for three readers, 94%-100% vs 72%-81%; respectively, P ≤ .06-.008), articular surface involvement (90%-97% vs 73%-87%; P ≤ .25), and multi-fragmentary patterns (96%-96% vs 68%-75%; P ≤ .03). Readers' diagnostic confidence improved considerably with access to CBCT data sets versus radiographs (all P ≤ .001). For CBCT, the median dose-length product was 70.9 mGy · cm, and the volume CT dose index was 4.4 mGy. Conclusion In acute elbow injuries, gantry-free cone-beam CT enabled improved detection of fractures, articular involvement, and multi-fragmentary patterns compared with two-dimensional radiography. Published under a CC BY 4.0 license Online supplemental material is available for this article.


Asunto(s)
Fracturas Óseas , Procedimientos Quirúrgicos Robotizados , Adulto , Niño , Humanos , Femenino , Dosis de Radiación , Codo , Estudios Retrospectivos , Tomografía Computarizada de Haz Cónico/métodos , Fracturas Óseas/diagnóstico por imagen
4.
Eur Radiol ; 33(11): 7818-7829, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37284870

RESUMEN

OBJECTIVES: While established for energy-integrating detector computed tomography (CT), the effect of virtual monoenergetic imaging (VMI) and iterative metal artifact reduction (iMAR) in photon-counting detector (PCD) CT lacks thorough investigation. This study evaluates VMI, iMAR, and combinations thereof in PCD-CT of patients with dental implants. MATERIAL AND METHODS: In 50 patients (25 women; mean age 62.0 ± 9.9 years), polychromatic 120 kVp imaging (T3D), VMI, T3DiMAR, and VMIiMAR were compared. VMIs were reconstructed at 40, 70, 110, 150, and 190 keV. Artifact reduction was assessed by attenuation and noise measurements in the most hyper- and hypodense artifacts, as well as in artifact-impaired soft tissue of the mouth floor. Three readers subjectively evaluated artifact extent and soft tissue interpretability. Furthermore, new artifacts through overcorrection were assessed. RESULTS: iMAR reduced hyper-/hypodense artifacts (T3D 1305.0/-1418.4 versus T3DiMAR 103.2/-46.9 HU), soft tissue impairment (106.7 versus 39.7 HU), and image noise (16.9 versus 5.2 HU) compared to non-iMAR datasets (p ≤ 0.001). VMIiMAR ≥ 110 keV subjectively enhanced artifact reduction over T3DiMAR (p ≤ 0.023). Without iMAR, VMI displayed no measurable artifact reduction (p ≥ 0.186) and facilitated no significant denoising over T3D (p ≥ 0.366). However, VMI ≥ 110 keV reduced soft tissue impairment (p ≤ 0.009). VMIiMAR ≥ 110 keV resulted in less overcorrection than T3DiMAR (p ≤ 0.001). Inter-reader reliability was moderate/good for hyperdense (0.707), hypodense (0.802), and soft tissue artifacts (0.804). CONCLUSION: While VMI alone holds minimal metal artifact reduction potential, iMAR post-processing enabled substantial reduction of hyperdense and hypodense artifacts. The combination of VMI ≥ 110 keV and iMAR resulted in the least extensive metal artifacts. CLINICAL RELEVANCE: Combining iMAR with VMI represents a potent tool for maxillofacial PCD-CT with dental implants achieving substantial artifact reduction and high image quality. KEY POINTS: • Post-processing of photon-counting CT scans with an iterative metal artifact reduction algorithm substantially reduces hyperdense and hypodense artifacts arising from dental implants. • Virtual monoenergetic images presented only minimal metal artifact reduction potential. • The combination of both provided a considerable benefit in subjective analysis compared to iterative metal artifact reduction alone.


Asunto(s)
Artefactos , Implantes Dentales , Humanos , Femenino , Persona de Mediana Edad , Anciano , Reproducibilidad de los Resultados , Metales , Tomografía Computarizada por Rayos X/métodos , Algoritmos
5.
Eur Radiol ; 33(11): 7830-7839, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37311805

RESUMEN

OBJECTIVE: To evaluate the image quality of an ultra-low contrast medium and radiation dose CT pulmonary angiography (CTPA) protocol for the diagnosis of acute pulmonary embolism using a clinical photon-counting detector (PCD) CT system and compare its performance to a dual-energy-(DE)-CTPA protocol on a conventional energy-integrating detector (EID) CT system. METHODS: Sixty-four patients either underwent CTPA with the novel scan protocol on the PCD-CT scanner (32 patients, 25 mL, CTDIvol 2.5 mGy·cm) or conventional DE-CTPA on a third-generation dual-source EID-CT (32 patients, 50 mL, CTDIvol 5.1 mGy·cm). Pulmonary artery CT attenuation, signal-to-noise ratio, and contrast-to-noise-ratio were assessed as objective criteria of image quality, while subjective ratings of four radiologists were compared at 60 keV using virtual monoenergetic imaging and polychromatic standard reconstructions. Interrater reliability was determined by means of the intraclass correlation coefficient (ICC). Effective dose was compared between patient cohorts. RESULTS: Subjective image quality was deemed superior by all four reviewers for 60-keV PCD scans (excellent or good ratings in 93.8% of PCD vs. 84.4% of 60 keV EID scans, ICC = 0.72). No examinations on either system were considered "non-diagnostic." Objective image quality parameters were significantly higher in the EID group (mostly p < 0.001), both in the polychromatic reconstructions and at 60 keV. The ED (1.4 vs. 3.3 mSv) was significantly lower in the PCD cohort (p < 0.001). CONCLUSIONS: PCD-CTPA allows for considerable reduction of contrast medium and radiation dose in the diagnosis of acute pulmonary embolism, while maintaining good to excellent image quality compared to conventional EID-CTPA. CLINICAL RELEVANCE STATEMENT: Clinical PCD-CT allows for spectral assessment of pulmonary vasculature with high scan speed, which is beneficial in patients with suspected pulmonary embolism, frequently presenting with dyspnea. Simultaneously PCD-CT enables substantial reduction of contrast medium and radiation dose. KEY POINTS: • The clinical photon-counting detector CT scanner used in this study allows for high-pitch multi-energy acquisitions. • Photon-counting computed tomography allows for considerable reduction of contrast medium and radiation dose in the diagnosis of acute pulmonary embolism. • Subjective image quality was rated best for 60-keV photon-counting scans.


Asunto(s)
Reducción Gradual de Medicamentos , Embolia Pulmonar , Humanos , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/métodos , Embolia Pulmonar/diagnóstico por imagen , Arteria Pulmonar/diagnóstico por imagen , Fotones , Fantasmas de Imagen
6.
Arch Orthop Trauma Surg ; 143(6): 3007-3013, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35794344

RESUMEN

INTRODUCTION: In spinal surgery, precise instrumentation is essential. This study aims to evaluate the accuracy of navigated, O-arm-controlled screw positioning in thoracic and lumbar spine instabilities. MATERIALS AND METHODS: Posterior instrumentation procedures between 2010 and 2015 were retrospectively analyzed. Pedicle screws were placed using 3D rotational fluoroscopy and neuronavigation. Accuracy of screw placement was assessed using a 6-grade scoring system. In addition, screw length was analyzed in relation to the vertebral body diameter. Intra- and postoperative revision rates were recorded. RESULTS: Thoracic and lumbar spine surgery was performed in 285 patients. Of 1704 pedicle screws, 1621 (95.1%) showed excellent positioning in 3D rotational fluoroscopy imaging. The lateral rim of either pedicle or vertebral body was protruded in 25 (1.5%) and 28 screws (1.6%), while the midline of the vertebral body was crossed in 8 screws (0.5%). Furthermore, 11 screws each (0.6%) fulfilled the criteria of full lateral and medial displacement. The median relative screw length was 92.6%. Intraoperative revision resulted in excellent positioning in 58 of 71 screws. Follow-up surgery due to missed primary malposition had to be performed for two screws in the same patient. Postsurgical symptom relief was reported in 82.1% of patients, whereas neurological deterioration occurred in 8.9% of cases with neurological follow-up. CONCLUSIONS: Combination of neuronavigation and 3D rotational fluoroscopy control ensures excellent accuracy in pedicle screw positioning. As misplaced screws can be detected reliably and revised intraoperatively, repeated surgery for screw malposition is rarely required.


Asunto(s)
Tornillos Pediculares , Fusión Vertebral , Cirugía Asistida por Computador , Humanos , Neuronavegación/métodos , Estudios Retrospectivos , Imagenología Tridimensional/métodos , Cirugía Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Vértebras Lumbares/cirugía , Fluoroscopía/métodos , Fusión Vertebral/métodos
7.
AJR Am J Roentgenol ; 218(4): 716-727, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34755521

RESUMEN

BACKGROUND. Head and neck CT can be limited by dental hardware artifact. Both postprocessing-based iterative metal artifact reduction (IMAR) and virtual monoenergetic imaging (VMI) reconstruction in dual-energy CT (DECT) can reduce metal artifact. Their combination is poorly described for single-source DECT systems. OBJECTIVE. The purpose of this study was to compare metal artifact reduction between VMI, IMAR, and their combination (VMIIMAR) in split-filter single-source DECT of patients with severe dental hardware artifact. METHODS. This retrospective study included 44 patients (nine woman, 35 men; mean age, 66.0 ± 10.4 years) who underwent head and neck CT and had severe dental hardware artifact. Standard, VMI, IMAR, and VMIIMAR images were generated; VMI and VMIIMAR were performed at 40, 70, 100, 120, 150, and 190 keV. ROIs were placed to measure corrected attenuation in pronounced hyperattenuating and hypoattenuating artifacts and artifact-impaired soft tissue and to measure corrected artifact-impaired soft-tissue noise. Two radiologists independently assessed soft-tissue interpretability (1-5 scale), and pooled ratings were analyzed. Readers selected the preferred reconstruction for each patient. RESULTS. Mean hyperattenuating artifact-corrected attenuation was 521.0 HU for standard imaging, 496.4-892.2 HU for VMI, 48.2 HU for IMAR, and 32.8-91.0 HU for VMIIMAR. Mean hypoattenuating artifact-corrected attenuation was -455.1 HU for standard imaging, -408.5 to -679.9 HU for VMI, -37.3 for IMAR, and -17.8 to -36.9 HU for VMIIMAR. Mean artifact-impaired soft tissue-corrected attenuation was 10.8 HU for standard imaging, -0.6 to 24.9 HU for VMI, 4.3 HU for IMAR, and -2.0 to 7.8 HU for VMIIMAR. Mean artifact-impaired soft tissue-corrected noise was 58.7 HU for standard imaging, 38.2 to 129.7 HU for VMI, 11.0 HU for IMAR, and 5.8 to 45.6 HU for VMIIMAR. Median soft-tissue interpretability was 1.2 for standard imaging, 1.1-1.2 for VMI, 3.7 for IMAR, and 2.0-3.8 for VMIIMAR. Artifact-impaired soft tissue-corrected attenuation and soft-tissue interpretability significantly improved (p < .05) for VMIIMAR versus IMAR only at 100 keV. The two readers preferred VMIIMAR at 100 keV in 56.8% and 59.1% of examinations. CONCLUSION. For reducing severe artifact due to dental material, IMAR has greater effect than VMI. Though the results for IMAR and VMIIMAR were similar overall, VMIIMAR had a small benefit at 100 keV. CLINICAL IMPACT. VMI and IMAR techniques in split-filter DECT may be combined for clinical head and neck imaging to reduce artifact from dental hardware and improve image quality.


Asunto(s)
Artefactos , Tomografía Computarizada por Rayos X , Anciano , Algoritmos , Femenino , Humanos , Masculino , Metales , Persona de Mediana Edad , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
8.
BMC Musculoskelet Disord ; 23(1): 189, 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-35232415

RESUMEN

BACKGROUND: Morphology and glenoid involvement determine the necessity of surgical management in scapula fractures. While being present in only a small share of patients with shoulder trauma, numerous classification systems have been in use over the years for categorization of scapula fractures. The purpose of this study was to evaluate the established AO/OTA classification in comparison to the classification system of Euler and Rüedi (ER) with regard to interobserver reliability and confidence in clinical practice. METHODS: Based on CT imaging, 149 patients with scapula fractures were retrospectively categorized by two trauma surgeons and two radiologists using the classification systems of ER and AO/OTA. To measure the interrater reliability, Fleiss kappa (κ) was calculated independently for both fracture classifications. Rater confidence was stated subjectively on a five-point scale and compared with Wilcoxon signed rank tests. Additionally, we computed the intraclass correlation coefficient (ICC) based on absolute agreement in a two-way random effects model to assess the diagnostic confidence agreement between observers. RESULTS: In scapula fractures involving the glenoid fossa, interrater reliability was substantial (κ = 0.722; 95% confidence interval [CI] 0.676-0.769) for the AO/OTA classification in contrast to moderate agreement (κ = 0.579; 95% CI 0.525-0.634) for the ER classification system. Diagnostic confidence for intra-articular fracture patterns was superior using the AO/OTA classification compared to ER (p < 0.001) with higher confidence agreement (ICC: 0.882 versus 0.831). For extra-articular fractures, ER (κ = 0.817; 95% CI 0.771-0.863) provided better interrater reliability compared to AO/OTA (κ = 0.734; 95% CI 0.692-0.776) with higher diagnostic confidence (p < 0.001) and superior agreement between confidence ratings (ICC: 0.881 versus 0.912). CONCLUSIONS: The AO/OTA classification is most suitable to categorize intra-articular scapula fractures with glenoid involvement, whereas the classification system of Euler and Rüedi appears to be superior in extra-articular injury patterns with fractures involving only the scapula body, spine, acromion and coracoid process.


Asunto(s)
Fracturas del Hombro , Humanos , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Estudios Retrospectivos , Escápula/diagnóstico por imagen
9.
BMC Musculoskelet Disord ; 23(1): 284, 2022 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-35331212

RESUMEN

BACKGROUND: In wrist arthrograms, aberrant contrast material is frequently seen extending into the soft tissue adjacent to the ulnar styloid process. Since the prestyloid recess can mimic contrast leakage in CT arthrography, this study aims to provide a detailed analysis of its morphologic variability, while investigating whether actual ulnar-sided leakage is associated with injuries of the triangular fibrocartilage complex (TFCC). METHODS: Eighty-six patients with positive wrist trauma history underwent multi-compartment CT arthrography (40 women, median age 44.5 years). Studies were reviewed by two board-certified radiologists, who documented the morphology of the prestyloid recess regarding size, opening type, shape and position, as well as the presence or absence of ulnar-sided contrast leakage. Correlations between leakage and the presence of TFCC injuries were assessed using the mean square contingency coefficient (rɸ). RESULTS: The most common configuration of the prestyloid recess included a narrow opening (73.26%; width 2.26 ± 1.43 mm), saccular shape (66.28%), and palmar position compared to the styloid process (55.81%). Its mean length and anterior-posterior diameter were 6.89 ± 2.36 and 5.05 ± 1.97 mm, respectively. Ulnar-sided contrast leakage was reported in 29 patients (33.72%) with a mean extent of 12.30 ± 5.31 mm. Leakage occurred more often in patients with ulnar-sided TFCC injuries (rɸ = 0.480; p < 0.001), whereas no association was found for lesions of the central articular disc (rɸ = 0.172; p = 0.111). CONCLUSIONS: Since ulnar-sided contrast leakage is more common in patients with peripheral TFCC injuries, distinction between an atypical configuration of the prestyloid recess and actual leakage is important in CT arthrography of the wrist.


Asunto(s)
Artrografía , Muñeca , Adulto , Femenino , Humanos , Tomografía Computarizada por Rayos X , Cúbito/diagnóstico por imagen , Cúbito/patología , Articulación de la Muñeca/diagnóstico por imagen
10.
Eur Radiol ; 31(12): 9399-9407, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34003353

RESUMEN

OBJECTIVES: Triangular fibrocartilage complex (TFCC) injuries frequently cause ulnar-sided wrist pain and can induce distal radioulnar joint instability. With its complex three-dimensional structure, diagnosis of TFCC lesions remains a challenging task even in MR arthrograms. The aim of this study was to assess the added diagnostic value of radial reformatting of isotropic 3D MRI datasets compared to standard planes after direct arthrography of the wrist. METHODS: Ninety-three patients underwent wrist MRI after fluoroscopy-guided multi-compartment arthrography. Two radiologists collectively analyzed two datasets of each MR arthrogram for TFCC injuries, with one set containing standard reconstructions of a 3D thin-slice sequence in axial, coronal and sagittal orientation, while the other set comprised an additional radial plane view with the rotating center positioned at the ulnar styloid. Surgical reports (whenever available) or radiological reports combined with clinical follow-up served as a standard of reference. In addition, diagnostic confidence and assessability of the central disc and ulnar-sided insertions were subjectively evaluated. RESULTS: Injuries of the articular disc, styloid and foveal ulnar attachment were present in 20 (23.7%), 10 (10.8%) and 9 (9.7%) patients. Additional radial planes increased diagnostic accuracy for lesions of the styloid (0.83 vs. 0.90; p = 0.016) and foveal (0.86 vs. 0.94; p = 0.039) insertion, whereas no improvement was identified for alterations of the central cartilage disc. Readers' confidence (p < 0.001) and assessability of the ulnar-sided insertions (p < 0.001) were superior with ancillary radial reformatting. CONCLUSIONS: Access to the radial plane view of isotropic 3D sequences in MR arthrography improves diagnostic accuracy and confidence for ulnar-sided TFCC lesions. KEY POINTS: • In multi-compartment arthrography of the wrist, ancillary radial plane view aids assessability of the foveal and styloid ulnar-sided insertions of the triangular fibrocartilage complex. • Assessment of peripheral TFCC injuries is more accurate with access to radial multiplanar reconstructions. • Additional radial planes provide greater diagnostic confidence.


Asunto(s)
Fibrocartílago Triangular , Traumatismos de la Muñeca , Artrografía , Humanos , Imagen por Resonancia Magnética , Fibrocartílago Triangular/diagnóstico por imagen , Muñeca , Traumatismos de la Muñeca/diagnóstico por imagen , Articulación de la Muñeca/diagnóstico por imagen
11.
Eur Radiol ; 31(6): 3600-3609, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33280057

RESUMEN

OBJECTIVES: Trauma evaluation of extremities can be challenging in conventional radiography. A multi-use x-ray system with cone-beam CT (CBCT) option facilitates ancillary 3-D imaging without repositioning. We assessed the clinical value of CBCT scans by analyzing the influence of additional findings on therapy. METHODS: Ninety-two patients underwent radiography and subsequent CBCT imaging with the twin robotic scanner (76 wrist/hand/finger and 16 ankle/foot/toe trauma scans). Reports by on-call radiologists before and after CBCT were compared regarding fracture detection, joint affliction, comminuted injuries, and diagnostic confidence. An orthopedic surgeon recommended therapy based on reported findings. Surgical reports (N = 52) and clinical follow-up (N = 85) were used as reference standard. RESULTS: CBCT detected more fractures (83/64 of 85), joint involvements (69/53 of 71), and multi-fragment situations (68/50 of 70) than radiography (all p < 0.001). Six fractures suspected in radiographs were ruled out by CBCT. Treatment changes based on additional information from CBCT were recommended in 29 patients (31.5%). While agreement between advised therapy before CBCT and actual treatment was moderate (κ = 0.41 [95% confidence interval 0.35-0.47]; p < 0.001), agreement after CBCT was almost perfect (κ = 0.88 [0.83-0.93]; p < 0.001). Diagnostic confidence increased considerably for CBCT studies (p < 0.001). Median effective dose for CBCT was 4.3 µSv [3.3-5.3 µSv] compared to 0.2 µSv [0.1-0.2 µSv] for radiography. CONCLUSIONS: CBCT provides advantages for the evaluation of acute small bone and joint trauma by detecting and excluding extremity fractures and fracture-related findings more reliably than radiographs. Additional findings induced therapy change in one third of patients, suggesting substantial clinical impact. KEY POINTS: • With cone-beam CT, extremity fractures and fracture-related findings can be detected and ruled out more reliably than with conventional radiography. • Additional diagnostic information provided by cone-beam CT scans has substantial impact on therapy in small bone and joint trauma. • For distal extremity injury assessment, one-stop-shop imaging without repositioning is feasible with the twin robotic x-ray system.


Asunto(s)
Fracturas Óseas , Procedimientos Quirúrgicos Robotizados , Tomografía Computarizada de Haz Cónico , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/terapia , Humanos , Radiografía , Rayos X
12.
Korean J Radiol ; 25(7): 662-672, 2024 07.
Artículo en Inglés | MEDLINE | ID: mdl-38942460

RESUMEN

Since the emergence of the first photon-counting computed tomography (PCCT) system in late 2021, its advantages and a wide range of applications in all fields of radiology have been demonstrated. Compared to standard energy-integrating detector-CT, PCCT allows for superior geometric dose efficiency in every examination. While this aspect by itself is groundbreaking, the advantages do not stop there. PCCT facilitates an unprecedented combination of ultra-high-resolution imaging without dose penalty or field-of-view restrictions, detector-based elimination of electronic noise, and ubiquitous multi-energy spectral information. Considering the high demands of orthopedic imaging for the visualization of minuscule details while simultaneously covering large portions of skeletal and soft tissue anatomy, no subspecialty may benefit more from this novel detector technology than musculoskeletal radiology. Deeply rooted in experimental and clinical research, this review article aims to provide an introduction to the cosmos of PCCT, explain its technical basics, and highlight the most promising applications for patient care, while also mentioning current limitations that need to be overcome.


Asunto(s)
Fotones , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Enfermedades Musculoesqueléticas/diagnóstico por imagen , Sistema Musculoesquelético/diagnóstico por imagen , Dosis de Radiación
13.
Eur J Radiol ; 170: 111209, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37992609

RESUMEN

PURPOSE: To investigate the metal artifact suppression potential of combining tin prefiltration and virtual monoenergetic imaging (VMI) for osseous microarchitecture depiction in ultra-high-resolution (UHR) photon-counting CT (PCCT) of the lower extremity. METHOD: Derived from tin-filtered UHR scans at 140 kVp, polychromatic datasets (T3D) and VMI reconstructions at 70, 110, 150, and 190 keV were compared in 117 patients with lower extremity metal implants (53 female; 62.1 ± 18.0 years). Three implant groups were investigated (total arthroplasty [n = 48], osteosynthetic material [n = 43], and external fixation [n = 26]). Image quality was assessed with regions of interest placed in the most pronounced artifacts and adjacent soft tissue, measuring the respective attenuation. Additionally, artifact extent, bone-metal interface interpretability and overall image quality were independently evaluated by three radiologists. RESULTS: Artifact reduction was superior with increasing keV level of VMI. While T3D was superior to VMI70keV (p ≥ 0.117), artifacts were more severe in T3D than in VMI ≥ 110 keV (all p ≤ 0.036). Image noise was highest for VMI70keV (all p < 0.001) and lowest for VMI110keV with comparable results for VMI110keV - VMI190keV. Subjective image quality regarding artifacts was superior for VMI ≥ 110 keV (all p ≤ 0.042) and comparable for VMI110keV - VMI190keV. Bone-metal interface interpretability was superior for VMI110keV (all p ≤ 0.001), while T3D, VMI150keV and VMI190keV were comparable. Overall image quality was deemed best for VMI110keV and VMI150keV. Interreader reliability was good in all cases (ICC ≥ 0.833). CONCLUSIONS: Tin-filtered UHR-PCCT scans of the lower extremity combined with VMI reconstructions allow for efficient artifact reduction in the vicinity of bone-metal interfaces.


Asunto(s)
Estaño , Tomografía Computarizada por Rayos X , Humanos , Femenino , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/métodos , Prótesis e Implantes , Procesamiento de Imagen Asistido por Computador/métodos , Metales , Artefactos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Relación Señal-Ruido , Estudios Retrospectivos
14.
Invest Radiol ; 59(4): 320-327, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-37812470

RESUMEN

BACKGROUND AND AIMS: This study aims to compare the performance of first-generation dual-source photon-counting detector computed tomography (PCD-CT) to third-generation dual-source energy-integrating detector (EID-CT) regarding stent imaging in the femoral arterial runoff. METHODS: Continuous extracorporeal perfusion was established in 1 human cadaver using an inguinal and infragenicular access and peristaltic pump. Seven peripheral stents were implanted into both superior femoral arteries by means of percutaneous angioplasty. Radiation dose-equivalent CT angiographies (high-/medium-/low-dose: 10/5/3 mGy) with constant tube voltage of 120 kVp, matching iterative reconstruction algorithm levels, and convolution kernels were used both with PCD-CT and EID-CT. In-stent lumen visibility, luminal and in-stent attenuation as well as contrast-to-noise ratio (CNR) were assessed via region of interest and diameter measurements. Results were compared using analyses of variance and regression analyses. RESULTS: Maximum in-stent lumen visibility achieved with PCD-CT was 94.48% ± 2.62%. The PCD-CT protocol with the lowest lumen visibility (BV40: 78.93% ± 4.67%) performed equal to the EID-CT protocol with the best lumen visibility (BV59: 79.49% ± 2.64%, P > 0.999). Photon-counting detector CT yielded superior CNR compared with EID-CT regardless of kernel and dose level ( P < 0.001). Maximum CNR was 48.8 ± 17.4 in PCD-CT versus 31.28 ± 5.7 in EID-CT (both BV40, high-dose). The theoretical dose reduction potential of PCD-CT over EID-CT was established at 88% (BV40), 83% (BV48/49), and 73% (BV59/60), respectively. In-stent attenuation was not significantly different from luminal attenuation outside stents in any protocol. CONCLUSIONS: With superior lumen visibility and CNR, PCD-CT allowed for noticeable dose reduction over EID-CT while maintaining image quality in a continuously perfused human cadaveric model.


Asunto(s)
Fotones , Tomografía Computarizada por Rayos X , Humanos , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Stents , Cadáver
15.
Invest Radiol ; 59(4): 293-297, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-37552040

RESUMEN

OBJECTIVES: The aim of this study was to investigate potential benefits of ultra-high resolution (UHR) over standard resolution scan mode in ultra-low dose photon-counting detector CT (PCD-CT) of the lung. MATERIALS AND METHODS: Six cadaveric specimens were examined with 5 dose settings using tin prefiltration, each in UHR (120 × 0.2 mm) and standard mode (144 × 0.4 mm), on a first-generation PCD-CT scanner. Image quality was evaluated quantitatively by noise comparisons in the trachea and both main bronchi. In addition, 16 readers (14 radiologists and 2 internal medicine physicians) independently completed a browser-based pairwise forced-choice comparison task for assessment of subjective image quality. The Kendall rank coefficient ( W ) was calculated to assess interrater agreement, and Pearson's correlation coefficient ( r ) was used to analyze the relationship between noise measurements and image quality rankings. RESULTS: Across all dose levels, image noise in UHR mode was lower than in standard mode for scan protocols matched by CTDI vol ( P < 0.001). UHR examinations exhibited noise levels comparable to the next higher dose setting in standard mode ( P ≥ 0.275). Subjective ranking of protocols based on 5760 pairwise tests showed high interrater agreement ( W = 0.99; P ≤ 0.001) with UHR images being preferred by readers in the majority of comparisons. Irrespective of scan mode, a substantial indirect correlation was observed between image noise and subjective image quality ranking ( r = -0.97; P ≤ 0.001). CONCLUSIONS: In PCD-CT of the lung, UHR scan mode reduces image noise considerably over standard resolution acquisition. Originating from the smaller detector element size in fan direction, the small pixel effect allows for superior image quality in ultra-low dose examinations with considerable potential for radiation dose reduction.


Asunto(s)
Fotones , Tomografía Computarizada por Rayos X , Humanos , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Pulmón/diagnóstico por imagen , Tórax
16.
Magn Reson Imaging ; 107: 100-110, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38246517

RESUMEN

INTRODUCTION: With increasing spatial resolution, diffusion-weighted imaging (DWI) may be suitable for morphologic lesion characterization in breast MRI - an area that has traditionally been occupied by dynamic contrast-enhanced imaging (DCE). This investigation compared DWI with b values of 800 and 1600 s/mm2 to DCE for lesion morphology assessment in high-resolution breast MRI at 3 Tesla. MATERIAL AND METHODS: Multiparametric breast MRI was performed in 91 patients with 93 histopathologically proven lesions (31 benign, 62 malignant). Two radiologists independently evaluated three datasets per patient (DWIb800; DWIb1600; DCE) and assessed lesion visibility and BIRADS morphology criteria. Diagnostic accuracy was compared among readers and datasets using Cochran's Q test and pairwise post-hoc McNemar tests. Bland-Altman analyses were conducted for lesion size comparisons. RESULTS: Discrimination of carcinomas was superior compared to benign findings in both DWIb800 and DWIb1600 (p < 0.001) with no b value-dependent difference. Similarly, assessability of mass lesions was better than of non-mass lesions, irrespective of b value (p < 0.001). Intra-reader reliability for the analysis of morphologic BIRADS criteria among DCE and DWI datasets was at least moderate (Fleiss κ≥0.557), while at least substantial inter-reader agreement was ascertained over all assessed categories (κ≥0.776). In pairwise Bland-Altman analyses, the measurement bias between DCE and DWIb800 was 0.7 mm, whereas the difference between DCE and DWIb1600 was 2.8 mm. DWIb1600 allowed for higher specificity than DCE (p = 0.007/0.062). CONCLUSIONS: DWI can be employed for reliable morphologic lesion characterization in high-resolution breast MRI. High b values increase diagnostic specificity, while lesion size assessment is more precise with standard 800 s/mm2 images.


Asunto(s)
Neoplasias de la Mama , Medios de Contraste , Humanos , Femenino , Reproducibilidad de los Resultados , Imagen de Difusión por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/métodos , Mama/diagnóstico por imagen , Mama/patología , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Sensibilidad y Especificidad , Estudios Retrospectivos
17.
Acad Radiol ; 2024 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-38403477

RESUMEN

RATIONALE AND OBJECTIVES: This study aims to compare the diagnostic confidence of photon-counting detector CT angiography (PCD-CTA) depending on the used vascular reformatting kernels with digital subtraction angiography (DSA) as diagnostic reference standard in peripheral arterial occlusive disease (PAOD). MATERIAL AND METHODS: In 39 patients, 45 lower extremity PCD-CTA with subsequent DSA were analyzed. Advanced PAOD (Fontaine stage 4) was ascertained in 77.8% of patients. CTA post-processing comprised three vascular kernels (Bv36/48/56). Objective image quality assessment included vessel attenuation, image noise, contrast-to-noise (CNR) and signal-to-noise ratios (SNR). Subjective evaluation of calcium blooming, vessel sharpness, luminal attenuation and image noise was performed by three radiologists. Diagnostic performance and concordance to DSA were assessed. RESULTS: The luminal attenuation remained kernel-independent constant. With sharper kernels, image noise increased substantially, while SNR and CNR decreased. Subjective reduction of calcium blooming and increased vessel sharpness were noted for the sharp Bv56 kernel. While sensitivity in stenosis quantification was comparable between kernels (81.6% vs. 81.5% vs. 81.0%, p = 0.797), specificity increased slightly higher sharpness (71.1% vs. 76.9% vs. 79.6%, p = 0.067). Diagnostic concordance of stenosis ratings compared to DSA increased likewise (Bv36 vs. Bv56, p = 0.002). Severe crural vessel calcifications had no influence on sensitivity, regardless of kernel selection. Contrarily, specificity was substantially worse in severely calcified tibial vessels but could be improved by using the sharp Bv56 kernel (Bv36 vs. Bv56 p = 0.024). Diagnostic confidence was highest for Bv56. CONCLUSION: In lower leg PCD-CTA, sharp convolution kernels increase diagnostic confidence compared to DSA by improved vessel delineation and reduced calcium blooming with acceptable image noise.

18.
Sci Rep ; 14(1): 4724, 2024 02 27.
Artículo en Inglés | MEDLINE | ID: mdl-38413684

RESUMEN

Photon-counting detector (PCD)-CT allows for reconstruction of virtual non-iodine (VNI) images from contrast-enhanced datasets. This study assesses the diagnostic performance of aortic valve calcification scoring (AVCS) derived from VNI datasets generated with a 1st generation clinical dual-source PCD-CT. AVCS was evaluated in 123 patients (statistical analysis only comprising patients with aortic valve calcifications [n = 56; 63.2 ± 11.6 years]), who underwent contrast enhanced electrocardiogram-gated (either prospective or retrospective or both) cardiac CT on a clinical PCD system. Patient data was reconstructed at 70 keV employing a VNI reconstruction algorithm. True non-contrast (TNC) scans at 70 keV without quantum iterative reconstruction served as reference in all individuals. Subgroup analysis was performed in 17 patients who received both, prospectively and retrospectively gated contrast enhanced scans (n = 8 with aortic valve calcifications). VNI images with prospective/retrospective gating had an overall sensitivity of 69.2%/56.0%, specificity of 100%/100%, accuracy of 85.4%/81.0%, positive predictive value of 100%/100%, and a negative predictive value of 78.2%/75.0%. VNI images with retrospective gating achieved similar results. For both gating approaches, AVCSVNI showed high correlation (r = 0.983, P < 0.001 for prospective; r = 0.986, P < 0.001 for retrospective) with AVCSTNC. Subgroup analyses demonstrated excellent intra-individual correlation between different acquisition modes (r = 0.986, P < 0.001). Thus, VNI images derived from cardiac PCD-CT allow for excellent diagnostic performance in the assessment of AVCS, suggesting potential for the omission of true non-contrast scans in the clinical workup of patients with aortic calcifications.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Válvula Aórtica/patología , Calcinosis , Yodo , Humanos , Estudios Retrospectivos , Válvula Aórtica/diagnóstico por imagen , Estudios Prospectivos , Tomografía Computarizada por Rayos X/métodos , Angiografía
19.
Invest Radiol ; 2024 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-38329822

RESUMEN

OBJECTIVES: Image acquisition in ultra-high-resolution (UHR) scan mode does not impose a dose penalty in photon-counting CT (PCCT). This study aims to investigate the dose saving potential of using UHR instead of standard-resolution PCCT for lumbar spine imaging. MATERIALS AND METHODS: Eight cadaveric specimens were examined with 7 dose levels (5-35 mGy) each in UHR (120 × 0.2 mm) and standard-resolution acquisition mode (144 × 0.4 mm) on a first-generation PCCT scanner. The UHR images were reconstructed with 3 dedicated bone kernels (Br68 [spatial frequency at 10% of the modulation transfer function 14.5 line pairs/cm], Br76 [21.0], and Br84 [27.9]), standard-resolution images with Br68 and Br76. Using automatic segmentation, contrast-to-noise ratios (CNRs) were established for lumbar vertebrae and psoas muscle tissue. In addition, image quality was assessed subjectively by 19 independent readers (15 radiologists, 4 surgeons) using a browser-based forced choice comparison tool totaling 16,974 performed pairwise tests. Pearson's correlation coefficient ( r ) was used to analyze the relationship between CNR and subjective image quality rankings, and Kendall W was calculated to assess interrater agreement. RESULTS: Irrespective of radiation exposure level, CNR was higher in UHR datasets than in standard-resolution images postprocessed with the same reconstruction parameters. The use of sharper convolution kernels entailed lower CNR but higher subjective image quality depending on radiation dose. Subjective assessment revealed high interrater agreement ( W = 0.86; P < 0.001) with UHR images being preferred by readers in the majority of comparisons on each dose level. Substantial correlation was ascertained between CNR and the subjective image quality ranking (all r 's ≥ 0.95; P < 0.001). CONCLUSIONS: In PCCT of the lumbar spine, UHR mode's smaller pixel size facilitates a considerable CNR increase over standard-resolution imaging, which can either be used for dose reduction or higher spatial resolution depending on the selected convolution kernel.

20.
Cancers (Basel) ; 16(6)2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38539562

RESUMEN

This study investigated whether virtual monoenergetic images (VMIs) and iodine mapping based on dual-energy CT (DECT) provide advantages in the assessment of endometrial cancer. A dual-source DECT was performed for primary staging of histologically proven endometrioid adenocarcinoma in 21 women (66.8 ± 12.0 years). In addition to iodine maps, VMIs at 40, 50, 60, 70, and 80 keV were reconstructed from polyenergetic images (PEIs). Objective analysis comprised the measurement of tumor contrast, contrast-to-noise ratio, and normalized iodine concentration (NIC). In addition, three radiologists independently rated tumor conspicuity. The highest tumor contrast (106.6 ± 45.0 HU) and contrast-to-noise ratio (4.4 ± 2.0) was established for VMIs at 40 keV. Tumor contrast in all VMIs ≤ 60 keV was higher than in PEIs (p < 0.001). The NIC of malignant tissue measured in iodine maps was substantially lower compared with a healthy myometrium (0.3 ± 0.1 versus 0.6 ± 0.1 mg/mL; p < 0.001). Tumor conspicuity was highest in 40 keV datasets, whereas no difference was found among PEIs and VMIs at 60 and 70 keV (p ≥ 0.334). Interobserver agreement was good, indicated by an intraclass correlation coefficient of 0.824 (0.772-0.876; p < 0.001). In conclusion, computation of VMIs at 40 keV and color-coded iodine maps aids the assessment of endometroid adenocarcinoma in primary staging.