Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Chem Rev ; 122(9): 8053-8125, 2022 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-35349271

RESUMEN

Alkali metal batteries based on lithium, sodium, and potassium anodes and sulfur-based cathodes are regarded as key for next-generation energy storage due to their high theoretical energy and potential cost effectiveness. However, metal-sulfur batteries remain challenged by several factors, including polysulfides' (PSs) dissolution, sluggish sulfur redox kinetics at the cathode, and metallic dendrite growth at the anode. Functional separators and interlayers are an innovative approach to remedying these drawbacks. Here we critically review the state-of-the-art in separators/interlayers for cathode and anode protection, covering the Li-S and the emerging Na-S and K-S systems. The approaches for improving electrochemical performance may be categorized as one or a combination of the following: Immobilization of polysulfides (cathode); catalyzing sulfur redox kinetics (cathode); introduction of protective layers to serve as an artificial solid electrolyte interphase (SEI) (anode); and combined improvement in electrolyte wetting and homogenization of ion flux (anode and cathode). It is demonstrated that while the advances in Li-S are relatively mature, less progress has been made with Na-S and K-S due to the more challenging redox chemistry at the cathode and increased electrochemical instability at the anode. Throughout these sections there is a complementary discussion of functional separators for emerging alkali metal systems based on metal-selenium and the metal-selenium sulfide. The focus then shifts to interlayers and artificial SEI/cathode electrolyte interphase (CEI) layers employed to stabilize solid-state electrolytes (SSEs) in metal-sulfur solid-state batteries (SSBs). The discussion of SSEs focuses on inorganic electrolytes based on Li- and Na-based oxides and sulfides but also touches on some hybrid systems with an inorganic matrix and a minority polymer phase. The review then moves to practical considerations for functional separators, including scaleup issues and Li-S technoeconomics. The review concludes with an outlook section, where we discuss emerging mechanics, spectroscopy, and advanced electron microscopy (e.g. cryo-transmission electron microscopy (cryo-TEM) and cryo-focused ion beam (cryo-FIB))-based approaches for analysis of functional separator structure-battery electrochemical performance interrelations. Throughout the review we identify the outstanding open scientific and technological questions while providing recommendations for future research topics.

2.
Biochem Biophys Res Commun ; 637: 136-143, 2022 12 31.
Artículo en Inglés | MEDLINE | ID: mdl-36399799

RESUMEN

Although microdialysis is a common in vivo sampling technique, a detailed characterization of the performance of a microdialysis probe used for sampling ethanol molecules has not been conducted. In this work, experimental and computational investigations were carried out to quantitatively study ethanol diffusion characteristics for home-made and commercially available probes. Probe efficiency, i.e. recovery rate (defined as the ethanol concentration in the dialysate to that in the external medium surrounding the probe) was used to characterize the performance. The recovery rate was measured at different perfusion flow rates (0.1, 0.2, 0.5, 1, 1.5, 2 µL/min) and external ethanol concentrations (1, 2.5, 5, 10, 20 mM) with controlled environmental conditions. Effect of temperature was also investigated at 19, 37 and 47 °C. The results show that reducing the flow rate from 2 to 0.1 µL/min at least triples the recovery rate for the home-made probes, and it remains nearly unchanged when varying external ethanol concentration. The performance for two commercial microdialysis probes with different membrane materials and configurations were also determined and have similar recovery rates. Through computational modeling, the diffusion coefficient of ethanol in the semipermeable membrane of the home-made probe was determined by fitting the experimental data, and it was found to be 9 × 1011 m2/s (R2 > 0.99). In addition, the depletion effect over time at different flow rates along with estimated in vivo ethanol clearance were simulated numerically, showing that the depletion region shrinks significantly when the flow rate is below 1 µL/min. The results provide better understanding of the diffusion characteristics of the microdialysis probe when used for sampling ethanol which can be used for better interpretation of in vivo measurements and for microdialysis probe optimization.


Asunto(s)
Etanol , Microdiálisis , Perfusión , Simulación por Computador , Difusión
3.
Anal Chem ; 93(35): 11929-11936, 2021 09 07.
Artículo en Inglés | MEDLINE | ID: mdl-34432431

RESUMEN

The brains of patients suffering from traumatic brain-injury (TBI) undergo dynamic chemical changes in the days following the initial trauma. Accurate and timely monitoring of these changes is of paramount importance for improved patient outcome. Conventional brain-chemistry monitoring is performed off-line by collecting and manually transferring microdialysis samples to an enzymatic colorimetric bedside analyzer every hour, which detects and quantifies the molecules of interest. However, off-line, hourly monitoring means that any subhourly neurochemical changes, which may be detrimental to patients, go unseen and thus untreated. Mid-infrared (mid-IR) spectroscopy allows rapid, reagent-free, molecular fingerprinting of liquid samples, and can be easily integrated with microfluidics. We used mid-IR transmission spectroscopy to analyze glucose, lactate, and pyruvate, three relevant brain metabolites, in the extracellular brain fluid of two TBI patients, sampled via microdialysis. Detection limits of 0.5, 0.2, and 0.1 mM were achieved for pure glucose, lactate, and pyruvate, respectively, in perfusion fluid using an external cavity-quantum cascade laser (EC-QCL) system with an integrated transmission flow-cell. Microdialysates were collected hourly, then pooled (3-4 h), and measured consecutively using the standard ISCUSflex analyzer and the EC-QCL system. There was a strong correlation between the compound concentrations obtained using the conventional bedside analyzer and the acquired mid-IR absorbance spectra, where a partial-least-squares regression model was implemented to compute concentrations. This study demonstrates the potential utility of mid-IR spectroscopy for continuous, automated, reagent-free, and online monitoring of the dynamic chemical changes in TBI patients, allowing a more timely response to adverse brain metabolism and consequently improving patient outcomes.


Asunto(s)
Líquido Extracelular , Láseres de Semiconductores , Glucosa , Humanos , Microdiálisis , Espectrofotometría Infrarroja
4.
Analyst ; 146(1): 109-117, 2021 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-33163998

RESUMEN

Detection and separation of gas-phase volatile organic compounds (VOCs) is of great importance for many applications including air quality monitoring, toxic gas detection and medical diagnostics. A lack of small and low-cost detectors limits the potential applications of VOC gas sensors, especially in the areas of consumer products and the 'Internet of Things'. Most of the commercially available low-cost technologies are either only capable of measuring a single VOC type, or only provide a total VOC concentration, without the ability to provide information on the nature or type of the VOC. We present a new approach for improving the selectivity of VOC detection, based on temporally resolved thermal desorption of VOCs from a nanoporous material, which can be combined with any existing VOC detector. This work uses a nanoporous silica material that adsorbs VOC molecules, which are then thermally desorbed onto a broadband VOC detector. Different VOCs are desorbed at different temperatures depending on their boiling point and affinity to the porous surface. The nanoporous silica is inert; VOC adsorption is proportional to the concentration of VOC in the environment, and is fully reversible. An example of a detection system using a commercial total VOC photoionization detector and a nanoporous silica preconcentrator is demonstrated here for six different VOCs, and shows potential for discrimination between the VOCs.

5.
Opt Express ; 26(12): 15539-15550, 2018 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-30114813

RESUMEN

Enhancement of sub-wavelength optical fields using sub-micron plasmonic probes has found many applications in chemical, material, biological and medical sciences. The enhancement is via localised surface-plasmon resonance (LSPR) which enables the highly sensitive vibrational-spectroscopy technique of surface-enhanced Raman scattering (SERS). Combining SERS with optical fibres can allow the monitoring of biochemical reactions in situ with high resolution. Here, we study the electromagnetic-field enhancement of a tapered optical fibre-tip coated with gold nanoparticles (AuNPs) using finite-element simulations. We investigate the electric-field enhancement associated with metallic NPs and study the effect of parameters such as tip-aperture radius, cone angle, nanoparticle size and gaps between them. Our study provides an understanding of the design and application of metal-nanoparticle-coated optical-fibre-tip probes for SERS. The approach of using fibre-coupled delivery adds flexibility and simplifies the system requirements in SERS, making it suitable for cellular imaging and mapping bio-interfaces.

6.
Anal Methods ; 16(26): 4322-4332, 2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-38888243

RESUMEN

Microdialysis is an important technique for in vivo sampling of tissue's biochemical composition. Understanding the factors that affect the performance of the microdialysis probes and developing methods for sample analysis are crucial for obtaining reliable results. In this work, we used experimental and numerical procedures to study the performance of microdialysis probes having different configurations, membrane materials and dimensions. For alcohol research, it is important to understand the dynamics of ethanol metabolism, particularly in the brain and in other organs, and to simultaneously measure the concentrations of ethanol and its metabolites - acetaldehyde and acetate. Our work provides a comprehensive characterization of three microdialysis probes, in terms of recovery rates and backpressure, allowing for interpretation and optimization of experimental procedures. In vivo experiments were performed to measure the time course concentration of ethanol, acetaldehyde, and acetate in the rat brain dialysate. Additionally, the combination of in vitro experimental results with numerical simulations enabled us to calculate diffusion coefficients of molecules in the microdialysis membranes and study the extent of the depletion effect caused by continuous microdialysis sampling, thus providing additional insights for probe selection and data interpretation.


Asunto(s)
Encéfalo , Etanol , Microdiálisis , Microdiálisis/métodos , Etanol/metabolismo , Etanol/análisis , Etanol/farmacocinética , Animales , Ratas , Encéfalo/metabolismo , Acetaldehído/análisis , Acetaldehído/metabolismo , Masculino , Acetatos/metabolismo , Acetatos/farmacocinética
7.
Analyst ; 138(16): 4574-8, 2013 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-23748709

RESUMEN

Using the bianalyte method we unambiguously demonstrate that a single gold nanosphere on a metal film junction, in the so-called nanoparticle on a mirror configuration, is capable of single molecule detection with surface-enhanced Raman spectroscopy (SERS). Also this configuration serves as a convenient and highly sensitive SERS sensor for detection of biomolecules. Such simple nano-junction based systems are ideal for chemical and biomedical analysis.


Asunto(s)
Oro/química , Nanopartículas del Metal/química , Espectrometría Raman/métodos
8.
Nanotechnology ; 24(3): 035201, 2013 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-23262989

RESUMEN

In this paper, we study the local-field enhancement in a system of a metallic nanoparticle placed very near to a dielectric substrate. In such systems, intense electric fields are localized in the gap between the particle and the substrate, creating a 'hot-spot' under appropriate excitation conditions. We use finite-element numerical simulations in order to study the field enhancement in this dielectric-metal system. More specifically, we show how the optical properties of the dielectric substrate (n and k) affect the plasmonic field enhancement in the nano-gap. We also analyze the degree of field confinement in the gap and discuss it in the context of utilization for surface-enhanced Raman scattering. We finally show the fields generated by real substrates and compare them to metallic ones.

9.
Nano Lett ; 12(8): 4242-6, 2012 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-22765890

RESUMEN

Metal oxide nanoparticles (MONPs) have widespread usage across many disciplines, but monitoring molecular processes at their surfaces in situ has not been possible. Here we demonstrate that MONPs give highly enhanced (×10(4)) Raman scattering signals from molecules at the interface permitting direct monitoring of their reactions, when placed on top of flat metallic surfaces. Experiments with different metal oxide materials and molecules indicate that the enhancement is generic and operates at the single nanoparticle level. Simulations confirm that the amplification is principally electromagnetic and is a result of optical modulation of the underlying plasmonic metallic surface by MONPs, which act as scattering antennae and couple light into the confined region sandwiched by the underlying surface. Because of additional functionalities of metal oxides as magnetic, photoelectrochemical and catalytic materials, enhanced Raman scattering mediated by MONPs opens up significant opportunities in fundamental science, allowing direct tracking and understanding of application-specific transformations at such interfaces. We show a first example by monitoring the MONP-assisted photocatalytic decomposition reaction of an organic dye by individual nanoparticles.

10.
Artículo en Inglés | MEDLINE | ID: mdl-37051259

RESUMEN

Continuous measurement of the concentrations of ethanol and its metabolites, acetaldehyde and acetic acid, in vivo is important for the alcohol research community. Most studies only measure ethanol because accurate measurement of all three compounds is challenging. Measurement inside tissue/brain is done using a microdialysis technique, followed by off-line analysis using gas chromatography (GC). To realize simultaneous measurement of ethanol and its metabolites, one can take advantage of infrared (IR) spectroscopy as a rapid and reagent-free method. Here we report a feasibility study of using IR spectroscopy to simultaneously measure ethanol, acetaldehyde and acetic acid in aqueous solution. Different concentrations in transmission mode at different optical pathlengths and using attenuated total reflectance (ATR) were measured. In vitro microdialysis was performed on the mixture of the three compounds, and the collected sample was measured using IR to demonstrate the capability of quantifying the concentrations of the three analytes simultaneously. Lastly, to overcome the limitations of the microdialysis technique, direct measurement using evanescent-field IR spectroscopy can be a potential alternative. A hydrophobic polymer coating that adsorbs ethanol and excludes water, could improve sensitivity. Sorption kinetics in polymethyl methacrylate (PMMA) and polydimethylsiloxane (PDMS) coatings on an ATR crystal were measured. Both polymers demonstrate preferential adsorption of ethanol over water.

11.
Brain Spine ; 3: 102686, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38021004

RESUMEN

Introduction: Complex metabolic disruption is a major aspect of the pathophysiology of traumatic brain injury (TBI). Pyruvate is an intermediate in glucose metabolism and considered one of the most clinically informative metabolites during neurocritical care of TBI patients, especially in deducing the lactate/pyruvate ratio (LPR) - a widely-used metric for probing the brain's metabolic redox state. LPR is conventionally measured offline on a bedside analyzer, on hourly accumulations of brain microdialysate. However, there is increasing interest within the field to quantify microdialysate pyruvate and LPR continuously in near-real-time within its pathophysiological range. We have previously measured pure standard pyruvate in-vitro using mid-infrared transmission, employing a commercially available external cavity-quantum cascade laser (EC-QCL) and a microfluidic flow cell and reported a limit of detection (LOD) of 0.1 mM. Research question: The present study was to test whether the current commercially available state-of-the-art mid-infrared transmission system, can detect pyruvate levels lower than previously reported. Materials and methods: We measured pyruvate in perfusion fluid on the mid-infrared transmission system also equipped with an EC-QCL and microfluidic flow cells, tested at three pathlengths. Results: We characterised the system to extract its relevant figures-of-merit and report the LOD of 0.07 mM. Discussion and conclusion: The reported LOD of 0.07 mM represents a clinically recognised threshold and is the lowest value reported in the field for a sensor that can be coupled to microdialysis. While work is ongoing for a definitive evaluation of the system to measuring pyruvate, these preliminary results set a good benchmark and reference against which future developments can be examined.

12.
Sens Diagn ; 1(4): 614-626, 2022 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-35923773

RESUMEN

Potassium is an important bodily electrolyte which is kept within tight limits in health. Many medical conditions as well as commonly-used drugs either raise or lower blood potassium levels, which can be dangerous or even fatal. For at-risk patients, frequent monitoring of potassium can improve safety and lifestyle, but conventional venous blood draws are inconvenient, don't provide a timely result and may be inaccurate. This review summarises current solutions and recent developments in point-of-care and self-testing potassium measurement technologies, which include devices for measurement of potassium in venous blood, devices for home blood collection and remote measurement, devices for rapid home measurement of potassium, wearable sensors for potassium in interstitial fluid, in sweat, in urine, as well as non-invasive potassium detection. We discuss the practical and clinical applicability of these technologies and provide future outlooks.

13.
Metabolites ; 12(5)2022 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-35629896

RESUMEN

In a traumatically injured brain, the cerebral microdialysis technique allows continuous sampling of fluid from the brain's extracellular space. The retrieved brain fluid contains useful metabolites that indicate the brain's energy state. Assessment of these metabolites along with other parameters, such as intracranial pressure, brain tissue oxygenation, and cerebral perfusion pressure, may help inform clinical decision making, guide medical treatments, and aid in the prognostication of patient outcomes. Currently, brain metabolites are assayed on bedside analysers and results can only be achieved hourly. This is a major drawback because critical information within each hour is lost. To address this, recent advances have focussed on developing biosensing techniques for integration with microdialysis to achieve continuous online monitoring. In this review, we discuss progress in this field, focusing on various types of sensing devices and their ability to quantify specific cerebral metabolites at clinically relevant concentrations. Important points that require further investigation are highlighted, and comments on future perspectives are provided.

14.
ACS Sens ; 7(1): 304-311, 2022 01 28.
Artículo en Inglés | MEDLINE | ID: mdl-34958564

RESUMEN

The selective detection of individual hazardous volatile organic compounds (VOCs) within a mixture is of great importance in industrial contexts due to environmental and health concerns. Achieving this with inexpensive, portable detectors continues to be a significant challenge. Here, a novel thermal separator system coupled with a photoionization detector has been developed, and its ability to selectively detect the VOCs isopropanol and 1-octene from a mixture of the two has been studied. The system includes a nanoporous silica preconcentrator in conjunction with a commercially available photoionization detector (PID). The PID is a broadband total VOC sensor with little selectivity; however, when used in conjunction with our thermal desorption approach, selective VOC detection within a mixture can be achieved. VOCs are adsorbed in the nanoporous silica over a 5 min period at 5 °C before being desorbed by heating at a fixed rate to 70 °C and detected by the PID. Different VOCs desorb at different times/temperatures, and mathematical analysis of the set of PID responses over time enabled the contributions from isopropanol and 1-octene to be separated. The concentrations of each compound individually could be measured in a mixture with limits of detection less than 10 ppbv and linearity errors less than 1%. Demonstration of a separation of a mixture of chemically similar compounds, benzene and o-xylene, is also provided.


Asunto(s)
Nanoporos , Compuestos Orgánicos Volátiles , 2-Propanol/análisis , Cromatografía de Gases , Dióxido de Silicio , Compuestos Orgánicos Volátiles/análisis
15.
ACS Omega ; 7(47): 43130-43138, 2022 Nov 29.
Artículo en Inglés | MEDLINE | ID: mdl-36467938

RESUMEN

Adsorption-desorption behaviors of polar and nonpolar volatile organic compounds (VOCs), namely, isopropanol and nonane, on mesoporous silica were studied using optical reflectance spectroscopy. Mesoporous silica was fabricated via electrochemical etching of silicon and subsequent thermal oxidation, resulting in an average pore diameter of 11 nm and a surface area of approximately 493 m2/g. The optical thickness of the porous layer, which is proportional to the number of adsorbed molecules, was measured using visible light reflectance interferometry. In situ adsorption and desorption kinetics were obtained for various mesoporous silica temperatures ranging from 10 to 70 °C. Sorption as a function of temperature was acquired for isopropanol and nonane. Sequential adsorption measurements of isopropanol and nonane were performed and showed that, when one VOC is introduced immediately following another, the second VOC displaces the first one regardless of the VOC's polarity and the strength of its interaction with the silica surface.

16.
Adv Mater ; 34(7): e2105855, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34738260

RESUMEN

This is the first report of a multifunctional separator for potassium-metal batteries (KMBs). Double-coated tape-cast microscale AlF3 on polypropylene (AlF3 @PP) yields state-of-the-art electrochemical performance: symmetric cells are stable after 1000 cycles (2000 h) at 0.5 mA cm-2 and 0.5 mAh cm-2 , with 0.042 V overpotential. Stability is maintained at 5.0 mA cm-2 for 600 cycles (240 h), with 0.138 V overpotential. Postcycled plated surface is dendrite-free, while stripped surface contains smooth solid electrolyte interphase (SEI). Conventional PP cells fail rapidly, with dendrites at plating, and "dead metal" and SEI clumps at stripping. Potassium hexacyanoferrate(III) cathode KMBs with AlF3 @PP display enhanced capacity retention (91% at 100 cycles vs 58%). AlF3 partially reacts with K to form an artificial SEI containing KF, AlF3 , and Al2 O3 phases. The AlF3 @PP promotes complete electrolyte wetting and enhances uptake, improves ion conductivity, and increases ion transference number. The higher of K+ transference number is ascribed to the strong interaction between AlF3 and FSI- anions, as revealed through 19 F NMR. The enhancement in wetting and performance is general, being demonstrated with ester- and ether-based solvents, with K-, Na-, or Li- salts, and with different commercial separators. In full batteries, AlF3 prevents Fe crossover and cycling-induced cathode pulverization.

17.
Langmuir ; 27(12): 7587-94, 2011 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-21619016

RESUMEN

Steady-state and time-resolved emission techniques have been employed to study the fluorescence properties of thioflavin-T (ThT) adsorbed on oxidized porous silicon (PSi) surfaces, with an average pore size of ∼10 nm. We found that the average fluorescence decay time of ThT, when it is adsorbed on the PSi surface, is rather long, τ(av) = 1.3 ns. We attribute this relatively long emission lifetime to the effect of the immobilization of ThT on the PSi surface, which inhibit the rotation of the aniline with respect to the benzothiazole moieties of ThT. We also measured the fluorescence properties of ThT in PSi samples in equilibrium with vapors of several liquids, such as methanol, acetonitrile, and water. We found that the fluorescence intensity drops by a factor of 10, and the average decay time, measured by a time-correlated single-photon counting technique, decreases by a factor of 3. We explain these results in terms of liquid condensation of the vapors in the PSi pores, which leads to partial dissolution of the ThT molecules in the liquid pools.


Asunto(s)
Silicio/química , Tiazoles/química , Benzotiazoles , Fluorescencia , Microscopía Electrónica de Rastreo , Propiedades de Superficie
18.
Appl Opt ; 49(8): 1341-9, 2010 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-20220890

RESUMEN

We investigate the basic chromatic properties of dispersive surface relief diffractive optical elements with porous silicon (PSi) layers. Rigorous and scalar wavelength-dependent diffraction efficiencies are juxtaposed and compared to reflection coefficients of uniform silicon and PSi layers. The application of the device as an enhanced sensor is discussed. A spectral covariance criterion for efficient evaluation of the spectral changes induced by analyte filling the pores is presented. Experimental results for the device reveal an increased spectral selectivity of the diffractively structured PSi layers compared to uniform PSi layers.

19.
ACS Omega ; 5(29): 18073-18079, 2020 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-32743181

RESUMEN

The detection of trace amounts of explosives in the vapor phase is of great importance. Preconcentration of the analyte is a useful technique to lower the detection limit of existing sensors. A nanoporous silica (pSiO2) substrate was evaluated as a preconcentrator for gas-phase 2,3-dimethyl-2,3-dinitrobutane (DMNB), a volatile detection taggant added by law to plastic explosives. After collection in pSiO2, the DMNB vapor was thermally desorbed at 70 °C into a gas chromatography-mass spectrometry sorbent tube. This was analyzed for the total mass of DMNB collected in pSiO2. The loading time and loading temperature of pSiO2 were varied systematically between 15 and 60 min and 5-20 °C, respectively. The preconcentrator's performance was compared to that of a nonporous substrate of the same material as a control. The collection efficiency of pSiO2 was calculated as approximately 20% of the total DMNB that passed over it in 30 min, at a concentration of 0.5 ppm in N2 carrier gas. It had enhancement factors compared to the nonporous substrate of 12 and 16 for 0.5 and 4.1 ppm DMNB, respectively, under the same conditions. No advantage was found with cooling pSiO2 below room temperature during the loading phase, which removes any need for a cooling system to aid preconcentration. The low desorption temperature of 70 °C is an advantage over other preconcentration systems, although a higher temperature could decrease the desorption time.

20.
RSC Adv ; 9(37): 21186-21191, 2019 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-35521343

RESUMEN

The increasing awareness of the harsh environmental and health risks associated with air pollution has placed volatile organic compounds (VOCs) sensor technologies in elevated demand. While the currently available VOC-monitoring technologies are either bulky and expensive, or only capable of measuring a total VOC concentration, the selective detection of VOCs in the gas-phase remains a challenge. To overcome this, a novel method and device based on mid-IR evanescent-wave fiber-optic spectroscopy, which enables enhanced detection of VOCs, is hereby proposed. This is achieved by increasing the number of analyte molecules in the proximity of the evanescent field via capillary condensation inside nano-porous microparticles coated on the fiber surface. The nano-porous structure of the coating allows the VOC analytes to rapidly diffuse into the pores and become concentrated at the surface of the fiber, thereby allowing the utilization of highly sensitive evanescent-wave spectroscopy. To ascertain the effectiveness and performance of the sensor, different VOCs are measured, and the enhanced sensitivity is analyzed using a custom-built gas cell. According to the results presented here, our VOC sensor shows a significantly increased sensitivity compared to that of an uncoated fiber.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA