1.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 76(10): 1035-1043, 2020.
Artículo en Japonés | MEDLINE | ID: mdl-33087649

RESUMEN

This study evaluated the effects of three types of hybrid iterative reconstruction (IR) on image quality of pediatric body computed tomography images. The image quality components evaluated were noise power spectrum (NPS), task-based modulation transfer function (TTF), and system performance function (SPF). As the IR strength was increased while reducing the radiation dose, the NPS increased in a low-frequency range and the TTF decreased in low-contrast regions. In the low-contrast regions, the calculated SPF decreased over the entire frequency range. Alternatively, in the high-contrast regions, the SPF decreased in the low-frequency regions and increased in the high-frequency regions. The radiation dose reduction using the hybrid IR resulted in the deterioration of the image quality in the low-contrast regions and changes in the spatial frequency characteristics in the high-contrast regions.


Asunto(s)
Algoritmos , Tomografía Computarizada por Rayos X , Niño , Recolección de Datos , Humanos , Fantasmas de Imagen , Dosis de Radiación
2.
Artículo en Japonés | MEDLINE | ID: mdl-30662031

RESUMEN

In many facilities, the displayed dose of dose-area product (DAP) is used for the dose management of interventional radiology. In this study, we investigated the measured dose at the patient entrance reference point (interventional reference point) and the displayed dose on each angiography systems. Also, we investigated the calibration method of each DAP. The errors of the measured dose and the displayed dose were less than 35%, but that dispersion was wide between the systems. The calibration methods varies according to a system. And even in the same manufacturer, the calibration methods were different. Therefore, to use the displayed dose of DAP for patient dose management, we need to compare that with the measured dose regularly. The differences of calibration methods induce the wide dispersion of the errors of the measured and the displayed dose. So the standardization of the calibration method in each manufacturer is expected.


Asunto(s)
Angiografía , Radiología Intervencionista , Calibración , Humanos , Control de Calidad , Dosis de Radiación , Encuestas y Cuestionarios