Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Eur Cell Mater ; 30: 232-47, 2015 Nov 04.
Artículo en Inglés | MEDLINE | ID: mdl-26535494

RESUMEN

Surgical implant-associated bone infections (osteomyelitis) have severe clinical and socioeconomic consequences. Treatment of chronic bone infections often involves antibiotics given systemically and locally to the affected site in poly (methyl methacrylate) (PMMA) bone cement. Given the high antibiotic concentrations required to affect bacteria in biofilm, local delivery is important to achieve high doses at the infection site. PMMA is not suitable to locally-deliver some biofilm-specific antibiotics, including rifampin, due to interference with PMMA polymerisation. To examine the efficacy of localised, combinational antibiotic delivery compared to PMMA standards, we fabricated rifampin- and vancomycin-laden calcium phosphate scaffolds (CPS) by three-dimensional (3D) printing to treat an implant-associated Staphylococcus aureus bone infection in a murine model. All vancomycin- and rifampin-laden CPS treatments significantly reduced the bacterial burden compared with vancomycin-laden PMMA. The bones were bacteria culture negative in 50 % of the mice that received sustained release vancomycin- and rifampin-laden CPS. In contrast, 100 % of the bones treated with vancomycin monotherapy using PMMA or CPS were culture positive. Yet, the monotherapy CPS significantly reduced the bacterial metabolic load following revision compared to PMMA. Biofilm persisted on the fixation hardware, but the infection-induced bone destruction was significantly reduced by local rifampin delivery. These data demonstrate that, despite the challenging implant-retaining infection model, co-delivery of rifampin and vancomycin from 3D printed CPS, which is not possible with PMMA, significantly improved the outcomes of implant-associated osteomyelitis. However, biofilm persistence on the fixation hardware reaffirms the importance of implant exchange or other biofilm eradication strategies to complement local antibiotics.


Asunto(s)
Antibacterianos/administración & dosificación , Cementos para Huesos , Osteomielitis/tratamiento farmacológico , Vancomicina/farmacología , Animales , Enfermedades Óseas/tratamiento farmacológico , Cerámica , Modelos Animales de Enfermedad , Ratones , Impresión Tridimensional , Infecciones Estafilocócicas/tratamiento farmacológico , Staphylococcus aureus/efectos de los fármacos
2.
Bone Joint Res ; 7(6): 422-429, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30034796

RESUMEN

AIMS: Plating displaced proximal humeral fractures is associated with a high rate of screw perforation. Dynamization of the proximal screws might prevent these complications. The aim of this study was to develop and evaluate a new gliding screw concept for plating proximal humeral fractures biomechanically. METHODS: Eight pairs of three-part humeral fractures were randomly assigned for pairwise instrumentation using either a prototype gliding plate or a standard PHILOS plate, and four pairs were fixed using the gliding plate with bone cement augmentation of its proximal screws. The specimens were cyclically tested under progressively increasing loading until perforation of a screw. Telescoping of a screw, varus tilting and screw migration were recorded using optical motion tracking. RESULTS: Mean initial stiffness (N/mm) was 581.3 (sd 239.7) for the gliding plate, 631.5 (sd 160.0) for the PHILOS and 440.2 (sd 97.6) for the gliding augmented plate without significant differences between the groups (p = 0.11). Mean varus tilting (°) after 7500 cycles was comparable between the gliding plate (2.6; sd 1.9), PHILOS (1.2; sd 0.6) and gliding augmented plate (1.7; sd 0.9) (p = 0.10). Similarly, mean screw migration(mm) after 7500 cycles was similar between the gliding plate (3.02; sd 2.85), PHILOS (1.30; sd 0.44) and gliding augmented plate (2.83; sd 1.18) (p = 0.13). Mean number of cycles until failure with 5° varus tilting were 12702 (sd 3687) for the gliding plate, 13948 (sd 1295) for PHILOS and 13189 (sd 2647) for the gliding augmented plate without significant differences between the groups (p = 0.66). CONCLUSION: Biomechanically, plate fixation using a new gliding screw technology did not show considerable advantages in comparison with fixation using a standard PHILOS plate. Based on the finding of telescoping of screws, however, it may represent a valid approach for further investigations into how to avoid the cut-out of screws.Cite this article: Y. P. Acklin, I. Zderic, J. A. Inzana, S. Grechenig, R. Schwyn, R. G. Richards, B. Gueorguiev. Biomechanical evaluation of a new gliding screw concept for the fixation of proximal humeral fractures. Bone Joint Res 2018;7:422-429. DOI: 10.1302/2046-3758.76.BJR-2017-0356.R1.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA