Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39256193

RESUMEN

Ticagrelor is a key antiplatelet agent used to prevent thrombotic events in patients with acute coronary syndrome. This open-label, 2-period, crossover Phase I study assessed the pharmacokinetics and bioequivalence of a generic ticagrelor 90-mg formulation compared to the innovator product under fasting conditions. Twenty-eight healthy White adults participated in the study. Each participant received a single dose of either the test or reference formulation, followed by a 7-day washout period before switching to the alternate formulation. Plasma concentrations of ticagrelor were measured using a validated high-performance liquid chromatography-tandem mass spectrometry method. Statistical analysis of primary pharmacokinetic parameters, including maximum concentration and area under the plasma concentration-time curve from time 0 to the last quantifiable concentration, showed bioequivalence with test/reference ratios of 110.9% and 107.1%, respectively, and 90% confidence intervals within the 80%-125% regulatory range. Treatment-emergent adverse events, such as headache, dysphagia, and dizziness, were moderate and transient and resolved promptly, with no significant difference in incidence between the formulations. These results confirm that the generic ticagrelor formulation is bioequivalent to the innovator product, supporting its use as an interchangeable option in clinical practice.

2.
Bioanalysis ; 16(11): 505-517, 2024 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-38864397

RESUMEN

The 16th GCC Closed Forum was held in Orlando, FL, USA, on 23 June 2023. Representatives from international bioanalytical Contract Research Organizations were in attendance in order to discuss scientific and regulatory issues specific to bioanalysis. The issues discussed at the meeting included: IS response, flow cytometry, changes to the bioanalytical industry, NGS assays, biomarker assay for tissues, dPCR validation, immunogenicity harmonization and ICH M10 implementation. Conclusions and consensus from discussions of these topics are included in this article.


Asunto(s)
Biomarcadores , Citometría de Flujo , Citometría de Flujo/normas , Citometría de Flujo/métodos , Biomarcadores/análisis , Humanos , Secuenciación de Nucleótidos de Alto Rendimiento , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos
3.
Anal Bioanal Chem ; 401(3): 1023-34, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21656175

RESUMEN

A new sensitive and fast quantitative analytical method for the simultaneous determination of clopidogrel, its main metabolite clopidogrel carboxylic acid, and the newly described acyl glucuronide metabolite, in human plasma samples, is presented. The analytical procedures (plasma storage, handling, and extract storage in the autosampler) were optimized in order to avoid back-conversion; a known drawback in measurements of clopidogrel. Clopidogrel acyl glucuronide was confirmed as a major source of back-conversion to the parent drug in the presence of methanol, and thorough stability experiments were carried out to find the most appropriate conditions for an accurate analysis of clopidogrel and the two metabolites. The method was validated by assessing selectivity, sensitivity, linearity, accuracy, and precision for all three analytes, in accordance to Food and Drug Administration guidelines. Spiked quality controls in plasma as well as incurred samples were used to verify back-conversion in the selected conditions, with results meeting European Medicines Agency acceptance criteria (concentrations within 80-120% of the first reading). The method was then applied to a pharmacokinetic study, and for the first time, a pharmacokinetic curve of clopidogrel acyl glucuronide in human plasma is presented. The concentrations ranged up to 1,048.684 ng/mL, with a mean of 470.268 ng/mL, while clopidogrel had a mean C(max) of 1.348 ng/mL; these orders of magnitude show how much the back-conversion of this metabolite may influence clopidogrel quantification if it is not properly controlled.


Asunto(s)
Análisis Químico de la Sangre/métodos , Cromatografía Líquida de Alta Presión , Espectrometría de Masas en Tándem , Ticlopidina/análogos & derivados , Clopidogrel , Humanos , Reproducibilidad de los Resultados , Ticlopidina/sangre
4.
Clin Pharmacol Drug Dev ; 9(7): 797-804, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-31793229

RESUMEN

Duloxetine is a combined serotonin and norepinephrine reuptake inhibitor indicated in adults for the treatment of major depressive disorder, diabetic peripheral neuropathic pain, and generalized anxiety disorder. The aim of these studies was to evaluate the effect of food on the pharmacokinetics and safety of duloxetine 60-mg gastroresistant hard capsules following single-dose administration. The data were obtained from 2 phase 1 bioequivalence studies, 1 in a fasting state and the other under fed conditions. Both studies have shown that, when administered as a single dose in the same prandial state, the test and reference duloxetine treatments were bioequivalent and exhibited similar safety profiles. The mean fed and fasting pharmacokinetic parameters and drug-related adverse events from the 2 studies were compared in order to assess the effect of food on the duloxetine bioavailability and respectively, tolerability. Administration of duloxetine in fed conditions increased peak plasma concentration by up to 30% and delayed mean time to peak concentration by an average of 1.15 hours while having an insignificant effect on extent of absorption (area under the plasma concentration-time curve in fed state within ±6% as compared with fasting conditions). Even though peak plasma levels were substantially higher in the fed state, there was no negative impact on the drug's safety profile. Actually, administration with food resulted in a lower average number of adverse events per single dose exposure. The negligible variation in overall systemic exposure suggests that efficacy remains unchanged irrespective of administration conditions; however, a better tolerability of the 60-mg dose is expected when the drug is taken with food.


Asunto(s)
Trastorno Depresivo Mayor/tratamiento farmacológico , Clorhidrato de Duloxetina/farmacocinética , Alimentos/efectos adversos , Inhibidores de Captación de Serotonina y Norepinefrina/farmacocinética , Adulto , Trastornos de Ansiedad/tratamiento farmacológico , Disponibilidad Biológica , Estudios Cruzados , Neuropatías Diabéticas/tratamiento farmacológico , Composición de Medicamentos/métodos , Clorhidrato de Duloxetina/administración & dosificación , Clorhidrato de Duloxetina/efectos adversos , Ayuno/sangre , Femenino , Interacciones Alimento-Droga/fisiología , Humanos , Masculino , Persona de Mediana Edad , Seguridad , Inhibidores de Captación de Serotonina y Norepinefrina/administración & dosificación , Inhibidores de Captación de Serotonina y Norepinefrina/efectos adversos , Equivalencia Terapéutica , Resultado del Tratamiento
5.
Bioanalysis ; 11(18s): 1-228, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31565956

RESUMEN

The 13th GCC Closed Forum for Bioanalysis was held in New Orleans, Louisiana, USA on April 5th, 2019. This GCC meeting was organized to discuss the contents of the 2019 ICH M10 Bioanalytical Method Validation Draft Guideline published in February 2019 and consolidate the feedback of the GCC members. In attendance were 63 senior-level participants from eight countries representing 44 bioanalytical CRO companies/sites. This event represented a unique opportunity for CRO bioanalytical experts to share their opinions and concerns regarding the ICH M10 Bioanalytical Method Validation Draft Guideline and to build unified comments to be provided to the ICH.


Asunto(s)
Biomarcadores/análisis , Guías como Asunto , Humanos , Reproducibilidad de los Resultados , Proyectos de Investigación
6.
Bioanalysis ; 9(7): 505-516, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28339299

RESUMEN

The 10th Global CRO Council (GCC) Closed Forum was held in Orlando, FL, USA on 18 April 2016. In attendance were decision makers from international CRO member companies offering bioanalytical services. The objective of this meeting was for GCC members to meet and discuss scientific and regulatory issues specific to bioanalysis. The issues discussed at this closed forum included reporting data from failed method validation runs, GCP for clinical sample bioanalysis, extracted sample stability, biomarker assay validation, processed batch acceptance criteria, electronic laboratory notebooks and data integrity, Health Canada's Notice regarding replicates in matrix stability evaluations, critical reagents and regulatory approaches to counteract fraud. In order to obtain the pharma perspectives on some of these topics, the first joint CRO-Pharma Scientific Interchange Meeting was held on 12 November 2016, in Denver, Colorado, USA. The five topics discussed at this Interchange meeting were reporting data from failed method validation runs, GCP for clinical sample bioanalysis, extracted sample stability, processed batch acceptance criteria and electronic laboratory notebooks and data integrity. The conclusions from the discussions of these topics at both meetings are included in this report.


Asunto(s)
Biomarcadores/análisis , Técnicas de Química Analítica/normas , Recolección de Datos/normas , Guías como Asunto , Preparaciones Farmacéuticas/análisis , Estabilidad de Medicamentos , Regulación Gubernamental , Humanos , Informe de Investigación
7.
J Chromatogr B Analyt Technol Biomed Life Sci ; 878(30): 3134-42, 2010 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-20956093

RESUMEN

Quantitative methods using LC-MS/MS allow achievement of adequate sensitivity for pharmacokinetic studies with clopidogrel; three such methods, with LLOQs as low as 5 pg/mL, were developed and fully validated according to the well established FDA 2001 guidelines. The chromatographic separations were performed on reversed phase columns Ascentis RP-Amide (15 cm x 2.1 mm, 5 µm), Ascentis Express C8 (10 cm x 2.1 mm, 2.7 µm) and Ascentis Express RP Amide (10 cm x 2.1 mm, 2.7 µm), respectively. Positive electrospray ionization in MRM mode was employed for the detection and a deuterated analogue (d3-clopidogrel) was used as internal standard. Linearity, precision, extraction recovery, matrix effects and stability tests on blank plasma spiked with clopidogrel and stored in different conditions met the acceptance criteria. During the analysis of the real samples from the first pharmacokinetic study, a significant increase (>100%) of the measured clopidogrel concentrations in the extracts kept in the autosampler at 10 °C was observed. Investigations led to the conclusion that most probably a back-conversion of one or more of the clopidogrel metabolites is occurring. The next methods were optimized in order to minimize this back-conversion. After a series of experiments, the adjustment of the sample preparation (e.g. processing at low temperature and introducing a clean-up step on Supelco HybridSPE-Precipitation cartridges) has proven to be the most effective in order to improve the stability of the extracts. Incurred samples of real subjects were successfully used in the validation of the last two analytical methods to evaluate the back-conversion, while tests using only the known metabolites could not detect this important problem.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Inhibidores de Agregación Plaquetaria/sangre , Espectrometría de Masas en Tándem/métodos , Ticlopidina/análogos & derivados , Cromatografía Líquida de Alta Presión/normas , Clopidogrel , Humanos , Estándares de Referencia , Espectrometría de Masa por Ionización de Electrospray/métodos , Espectrometría de Masa por Ionización de Electrospray/normas , Espectrometría de Masas en Tándem/normas , Ticlopidina/sangre
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA