Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Dig Endosc ; 2024 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-39162053

RESUMEN

In recent years, the usefulness of endoscopic ultrasound (EUS) has been recognized in children. A dedicated pediatric EUS scope has not been developed; in our experience, however, an adult EUS scope can be used. The American Society for Gastrointestinal Endoscopy Technical Committee status assessment report on pediatric endoscopy equipment provides some guidance on the feasibility of EUS according to body size. Careful monitoring is required, keeping in mind potential adverse events such as cervical esophageal perforation and unstable breathing due to tracheal compression. Most devices designed for interventional pancreatobiliary endoscopy are also available for children. Sedation or intubated general anesthesia (GA) is mandatory when performing interventional EUS (I-EUS). I-EUS for children is generally performed using GA in the operating room, but sedation in the endoscopy room is also possible under appropriate monitoring by pediatricians. I-EUS in the operating room is sometimes difficult for endoscopists to perform because of the unsuitable fluoroscopic imaging and the lack of familiar equipment and staff. Compared to GA, sedation in the endoscopy room facilitates easier and quicker repetition of procedures when necessary. Adult pancreatobiliary endoscopists perform most I-EUS procedures in the pediatric population because most pediatric endoscopists have few opportunities to perform EUS-related procedures and thus have difficulty maintaining their skills. To popularize I-EUS techniques for children, it will be necessary to establish a training program for developing pediatric endoscopists.

2.
Dig Endosc ; 2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-38845085

RESUMEN

The consensus-based TOKYO criteria were proposed as a standardized reporting system for endoscopic transpapillary biliary drainage. The primary objective was to address issues arising from the inconsistent reporting of stent outcomes across studies, which has complicated the comparability and interpretation of study results. However, the original TOKYO criteria were not readily applicable to recent modalities of endoscopic biliary drainage such as biliary drainage based on endoscopic ultrasound or device-assisted endoscopy. There are increasing opportunities for managing hilar biliary obstruction and benign biliary strictures through endoscopic drainage. Biliary ablation has been introduced to manage benign and malignant biliary strictures. In addition, the prolonged survival times of cancer patients have increased the importance of evaluating overall outcomes during the period requiring endoscopic biliary drainage rather than solely focusing on the patency of the initial stent. Recognizing these unmet needs, a committee has been established within the Japan Gastroenterological Endoscopy Society to revise the TOKYO criteria for current clinical practice. The revised criteria propose not only common reporting items for endoscopic biliary drainage overall, but also items specific to various conditions and interventions. The term "stent-demanding time" has been defined to encompass the entire duration of endoscopic biliary drainage, during which the overall stent-related outcomes are evaluated. The revised TOKYO criteria 2024 are expected to facilitate the design and reporting of clinical studies, providing a goal-oriented approach to the evaluation of endoscopic biliary drainage.

6.
J Clin Med ; 13(10)2024 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-38792381

RESUMEN

Background/Objective: Interventional endoscopic ultrasound (I-EUS) is technically difficult and has risks of severe adverse events due to the scarcity of dedicated endoscopes and tools. A new EUS scope was developed for I-EUS and was modified to increase the puncture range, reduce the blind area, and overcome guidewire difficulties. We evaluated the usefulness and safety of a new EUS scope compared to a conventional EUS scope. Methods: All I-EUS procedures were performed at Juntendo University Hospital from April 2020 to April 2022. The primary outcomes included the procedure time and fluoroscopy time. The secondary outcomes included the technical success rate and the rates of procedure-related adverse events. Clinical data were retrospectively reviewed and statistically analyzed between the new and conventional EUS scopes. Results: In total, 143 procedures in 120 patients were analyzed. The procedure time was significantly shorter with the new EUS scope, but the fluoroscopy time was not different. Among the patients only undergoing EUS-guided biliary drainage (EUS-BD), 79 procedures in 74 patients were analyzed. Both the procedure time and fluoroscopy time were significantly shorter with the new EUS scope. Multivariate analysis revealed that a new EUS scope and use of covered metal stents could reduce the fluoroscopy time. The technical success rate and the adverse event rate were not significantly different between the total I-EUS and the EUS-BD only groups. However, the conventional scope showed stent deviation during stent placement, which did not happen with the new scope. Conclusions: The new EUS scope reduced procedure time for total I-EUS and fluoroscopy time for EUS-BD compared to a conventional EUS scope because of the improvement suitable for I-EUS.

7.
Artículo en Inglés | MEDLINE | ID: mdl-38854708

RESUMEN

Endoscopic ultrasound (EUS)-guided pancreatic duct drainage includes two procedures: EUS-guided drainage/anastomosis (EUS-D/A) and trans-papillary drainage with EUS-assisted pancreatic rendezvous. EUS-guided pancreatogastrostomy is the most common EUS-D/A procedure and is recommended as a salvage procedure in cases in which endoscopic retrograde cholangiopancreatography fails or is difficult. However, initial EUS-D/A is performed in patients with surgically altered anatomy at our institution. It is one of the most difficult interventional EUS procedures and has a high incidence of adverse events. The technical difficulties differ according to etiology, and the incidence of adverse events varies between initial EUS-D/A and subsequent trans-endosonographically/EUS-guided created route procedures. Hence, it is important to meticulously prepare a procedure based on the patient's condition and the available devices. The technical difficulties in EUS-D/A include: (1) determination of the puncture point, (2) selection of a puncture needle and guidewire, (3) guidewire manipulation, and (4) dilation of the puncture route and stenting. Proper technical procedures are important to increase the success rate and reduce the incidence and severity of adverse events. The complexity of EUS-D/A is also contingent on the severity of pancreatic fibrosis and stricture. In post-pancreatectomy cases, determination of the puncture site is important for success because of the remnant pancreas. Trans-endosonographically/EUS-guided created route procedures following initial EUS-D/A are also important for achieving the treatment goal. This article focuses on effective strategies for initial EUS-D/A, based on the etiology and condition of the pancreas. We mainly discuss EUS-D/A, including its indications, techniques, and success-enhancing strategies.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA