Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Clin Gastroenterol Hepatol ; 22(7): 1416-1426.e5, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38615727

RESUMEN

BACKGROUND & AIMS: Despite previously reported treatment strategies for nonfunctioning small (≤20 mm) pancreatic neuroendocrine neoplasms (pNENs), uncertainties persist. We aimed to evaluate the surgically resected cases of nonfunctioning small pNENs (NF-spNENs) in a large Japanese cohort to elucidate an optimal treatment strategy for NF-spNENs. METHODS: In this Japanese multicenter study, data were retrospectively collected from patients who underwent pancreatectomy between January 1996 and December 2019, were pathologically diagnosed with pNEN, and were treated according to the World Health Organization 2019 classification. Overall, 1490 patients met the eligibility criteria, and 1014 were included in the analysis cohort. RESULTS: In the analysis cohort, 606 patients (59.8%) had NF-spNENs, with 82% classified as grade 1 (NET-G1) and 18% as grade 2 (NET-G2) or higher. The incidence of lymph node metastasis (N1) by grade was significantly higher in NET-G2 (G1: 3.1% vs G2: 15.0%). Independent factors contributing to N1 were NET-G2 or higher and tumor diameter ≥15 mm. The predictive ability of tumor size for N1 was high. Independent factors contributing to recurrence included multiple lesions, NET-G2 or higher, tumor diameter ≥15 mm, and N1. However, the independent factor contributing to survival was tumor grade (NET-G2 or higher). The appropriate timing for surgical resection of NET-G1 and NET-G2 or higher was when tumors were >20 and >10 mm, respectively. For neoplasms with unknown preoperative grades, tumor size >15 mm was considered appropriate. CONCLUSIONS: NF-spNENs are heterogeneous with varying levels of malignancy. Therefore, treatment strategies based on tumor size alone can be unreliable; personalized treatment strategies that consider tumor grading are preferable.


Asunto(s)
Pancreatectomía , Neoplasias Pancreáticas , Humanos , Neoplasias Pancreáticas/cirugía , Neoplasias Pancreáticas/patología , Neoplasias Pancreáticas/mortalidad , Masculino , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Anciano , Japón/epidemiología , Adulto , Tumores Neuroendocrinos/cirugía , Tumores Neuroendocrinos/patología , Tumores Neuroendocrinos/terapia , Tumores Neuroendocrinos/diagnóstico , Anciano de 80 o más Años , Metástasis Linfática , Clasificación del Tumor , Carga Tumoral
2.
Gastrointest Endosc ; 98(1): 36-42.e1, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36646149

RESUMEN

BACKGROUND AND AIMS: Acute cholecystitis is occasionally observed after biliary drainage using a covered self-expandable metal stent (CSEMS) for distal biliary obstruction (DBO). Gallbladder drainage before CSEMS placement may reduce cholecystitis. This study aimed to examine the preventive effect of endoscopic gallbladder stent placement (EGBS) on cholecystitis with CSEMSs. METHODS: We retrospectively analyzed patients with DBO who underwent CSEMS placement across the orifice of the cystic duct between November 2014 and October 2021 and were negative for cholecystitis on biliary drainage. Prophylactic EGBS was attempted before CSEMS placement. The incidence of cholecystitis was compared between patients with and without EGBS. RESULTS: In total, 286 patients (128 men; median age, 75 years) were included in this study. EGBS was attempted in 32 patients before CSEMS placement, and technical success was achieved in 24 patients (75%). Adverse events were noted in 3 patients (9.4%; penetration of cystic duct in 1 and acute pancreatitis in 2). The cumulative incidence of cholecystitis was significantly lower in patients with EGBS than in those without EGBS (1 [4.2%] vs 56 [21.4%], P = .045). In multivariable analysis, EGBS was a significant protective factor against cholecystitis (hazard ratio, .11; 95% confidence interval, .01-.79; P = .028). CONCLUSIONS: Although the transpapillary approach to the gallbladder is not easy for patients with DBO, EGBS is effective in preventing cholecystitis associated with CSEMS placement.


Asunto(s)
Colecistitis , Colestasis , Pancreatitis , Anciano , Humanos , Masculino , Enfermedad Aguda , Colecistitis/etiología , Colestasis/etiología , Colestasis/prevención & control , Colestasis/cirugía , Pancreatitis/epidemiología , Pancreatitis/etiología , Pancreatitis/prevención & control , Estudios Retrospectivos , Stents , Femenino
3.
Dig Endosc ; 35(3): 369-376, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36129765

RESUMEN

OBJECTIVES: Although covered self-expandable metal stents (CSEMSs) are associated with the risk of postendoscopic retrograde cholangiopancreatography (ERCP) pancreatitis due to pancreatic duct (PD) orifice obstruction, they are often used for biliary drainage treatment in malignant biliary obstruction (MBO). This study aimed to investigate the efficacy of PD stenting in preventing post-ERCP pancreatitis after CSEMS implantation. METHODS: This retrospective cohort study analyzed 554 patients with transpapillary CSEMS for MBO. Patients with noninitial deployment, benign disease, CSEMS deployment above the papilla, surgically altered anatomy, uncovered self-expandable metal stents, multiple thin self-expandable metal stents, and unavailable procedure videos were excluded. Logistic regression analysis estimated the association between PD stenting and post-ERCP pancreatitis incidence. We adjusted for age, sex, pancreatitis history, prophylactic rectal nonsteroidal anti-inflammatory drug use, naïve papilla, MBO etiology, and prolonged biliary cannulation time. RESULTS: Among 554 patients, 67 (12.1%) experienced post-ERCP pancreatitis. Post-ERCP pancreatitis was recorded in 13.7% of patients in the non-PD stenting and 4.3% in the PD stenting groups. Pancreatic duct stenting was associated with lower risks of post-ERCP pancreatitis (odds ratio [OR] 0.28; 95% confidence interval [CI] 0.099-0.79; P = 0.028). In multivariable analysis, the association between PD stenting and lower post-ERCP pancreatitis incidence was consistent (OR 0.19; 95% CI 0.062-0.58; P = 0.0034). CONCLUSIONS: Pancreatic duct stenting could reduce the risk of post-ERCP pancreatitis after CSEMSs.


Asunto(s)
Enfermedades Pancreáticas , Pancreatitis , Humanos , Colangiopancreatografia Retrógrada Endoscópica/efectos adversos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Estudios Retrospectivos , Conductos Pancreáticos/cirugía , Pancreatitis/epidemiología , Pancreatitis/etiología , Pancreatitis/prevención & control , Stents/efectos adversos
4.
Gastrointest Endosc ; 93(4): 952-959, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-32730821

RESUMEN

BACKGROUND AND AIMS: Cold snare defect protrusions (CSDPs) include muscularis mucosa (MM) and submucosa tissue. CSDPs are thought to result from fragmentation of the specimen during shallow excision. Our aim in this study was to clarify whether CSDPs are associated with polyp fragmentation. METHODS: We retrospectively analyzed 1026 neoplastic colorectal polyps resected by cold snare polypectomy for which the presence or absence of CSDPs was assessed from the endoscopic image. All prepared specimens were reviewed and assessed for the presence or absence of polyp fragmentation, and the proportion of MM on the stump was measured. In addition, the risk factors for CSDP occurrence were evaluated. RESULTS: CSDPs occurred in 116 of the 1026 polyps (11.3%). Polyp fragmentation was significantly associated with the occurrence of CSDP on univariate analysis (odds ratio [OR], 3.74; P < .001) and multivariate analysis (OR, 3.13; P < .001). The proportion of MM >50% was significantly lower in the CSDP group than in the non-CSDP group (51.5% vs 70.9%, P < .001). CSDPs were significantly associated with a large polyp size (OR, 1.32; P = .007) and a large specimen size (OR, 1.24; P < .001) on multivariate analysis. CONCLUSIONS: The occurrence of CSDP was associated with less MM on the stump and fragmentation of the specimen. Clinically, the presence of CSDP is a good indicator of polyp fragmentation.


Asunto(s)
Pólipos del Colon , Pólipos del Colon/cirugía , Colonoscopía , Humanos , Estudios Retrospectivos , Factores de Riesgo
5.
J Gastroenterol Hepatol ; 36(1): 131-136, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32511793

RESUMEN

BACKGROUND AND AIM: Conventional endoscopy for the early detection of esophageal and esophagogastric junctional adenocarcinoma (E/J cancer) is limited because early lesions are asymptomatic, and the associated changes in the mucosa are subtle. There are no reports on artificial intelligence (AI) diagnosis for E/J cancer from Asian countries. Therefore, we aimed to develop a computerized image analysis system using deep learning for the detection of E/J cancers. METHODS: A total of 1172 images from 166 pathologically proven superficial E/J cancer cases and 2271 images of normal mucosa in esophagogastric junctional from 219 cases were used as the training image data. A total of 232 images from 36 cancer cases and 43 non-cancerous cases were used as the validation test data. The same validation test data were diagnosed by 15 board-certified specialists (experts). RESULTS: The sensitivity, specificity, and accuracy of the AI system were 94%, 42%, and 66%, respectively, and that of the experts were 88%, 43%, and 63%, respectively. The sensitivity of the AI system was favorable, while its specificity for non-cancerous lesions was similar to that of the experts. Interobserver agreement among the experts for detecting superficial E/J was fair (Fleiss' kappa = 0.26, z = 20.4, P < 0.001). CONCLUSIONS: Our AI system achieved high sensitivity and acceptable specificity for the detection of E/J cancers and may be a good supporting tool for the screening of E/J cancers.


Asunto(s)
Adenocarcinoma/diagnóstico por imagen , Inteligencia Artificial , Aprendizaje Profundo , Detección Precoz del Cáncer/métodos , Neoplasias Esofágicas/diagnóstico por imagen , Unión Esofagogástrica/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Neoplasias Gástricas/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Asia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad
7.
Dig Dis Sci ; 64(10): 2982-2991, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31011943

RESUMEN

BACKGROUND: Although endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) has been widely used for the diagnosis of pancreatic tumors, the ability to obtain adequate pancreatic tumor tissue needs to be improved. AIMS: This study was performed to compare a newly designed 21-gauge needle (EUS Sonopsy CY; Hakko Medical, Nagano, Japan) and a standard 22-gauge needle for tissue sampling of solid pancreatic masses. METHODS: Consecutive patients with solid pancreatic masses who underwent EUS-FNA with either the EUS Sonopsy CY or the 22-gauge needle from June 2014 to December 2016 were enrolled. The primary outcome was comparison of the diagnostic yield of the FNA samples. The secondary outcomes were comparison of technical success, diagnostic ability for malignancy, and complications. RESULTS: A total of 93 patients (40.9% female; mean age, 70.1 years) underwent EUS-FNA with the EUS Sonopsy CY (n = 47) or the standard 22-gauge needle (n = 46). The technical success rate was 100% in both groups, and the overall diagnostic accuracy for malignancy was similar between the groups (100% in the EUS Sonopsy CY group vs. 95.7% in the 22-gauge needle group, P = 0.242). Nevertheless, the EUS Sonopsy CY resulted in significantly higher scores for cellularity (P = 0.006) and lower scores for blood contamination (P < 0.001). The procedure-related complication rate was comparable between the groups (P = 0.148). CONCLUSIONS: The EUS Sonopsy CY provided higher-quality specimens for histological evaluation in terms of both sample cellularity and blood contamination for the diagnosis of solid pancreatic masses. TRIAL REGISTRATION: The study was registered in a clinical trial registry, No. UMIN000032598.


Asunto(s)
Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico , Agujas/normas , Páncreas/patología , Neoplasias Pancreáticas/patología , Manejo de Especímenes , Anciano , Investigación sobre la Eficacia Comparativa , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/instrumentación , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/métodos , Diseño de Equipo , Femenino , Humanos , Japón , Masculino , Evaluación de Resultado en la Atención de Salud , Neoplasias Pancreáticas/diagnóstico , Manejo de Especímenes/instrumentación , Manejo de Especímenes/métodos
9.
Int J Neuropsychopharmacol ; 20(12): 957-962, 2017 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-29016875

RESUMEN

Background: The norepinephrine transporter in the brain has been targeted in the treatment of psychiatric disorders. Duloxetine is a serotonin and norepinephrine reuptake inhibitor that has been widely used for the treatment of depression. However, the relationship between dose and plasma concentration of duloxetine and norepinephrine transporter occupancy in the human brain has not been determined. In this study, we examined norepinephrine transporter occupancy by different doses of duloxetine. Methods: We calculated norepinephrine transporter occupancies from 2 positron emission tomography scans using (S,S)-[18F]FMeNER-D2 before and after a single oral dose of duloxetine (20 mg, n = 3; 40 mg, n = 3; 60 mg, n =2). Positron emission tomography scans were performed from 120 to 180 minutes after an i.v. bolus injection of (S,S)-[18F]FMeNER-D2. Venous blood samples were taken to measure the plasma concentration of duloxetine just before and after the second positron emission tomography scan. Results: Norepinephrine transporter occupancy by duloxetine was 29.7% at 20 mg, 30.5% at 40 mg, and 40.0% at 60 mg. The estimated dose of duloxetine inducing 50% norepinephrine transporter occupancy was 76.8 mg, and the estimated plasma drug concentration inducing 50% norepinephrine transporter occupancy was 58.0 ng/mL. Conclusions: Norepinephrine transporter occupancy by clinical doses of duloxetine was approximately 30% to 40% in human brain as estimated using positron emission tomography with (S,S)-[18F]FMeNER-D2.


Asunto(s)
Antidepresivos/farmacología , Encéfalo/efectos de los fármacos , Encéfalo/diagnóstico por imagen , Clorhidrato de Duloxetina/farmacología , Morfolinas/farmacocinética , Tomografía de Emisión de Positrones , Adulto , Relación Dosis-Respuesta a Droga , Clorhidrato de Duloxetina/sangre , Radioisótopos de Flúor , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Masculino , Proteínas de Transporte de Noradrenalina a través de la Membrana Plasmática/metabolismo , Unión Proteica/efectos de los fármacos , Adulto Joven
10.
Oncology ; 93 Suppl 1: 43-48, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29258112

RESUMEN

OBJECTIVES: This study aimed to evaluate the characteristics and the feasibility of 18-mm-diameter stents for obstructive colorectal cancer, comparing the clinical courses with 22- mm-diameter stents. METHODS: We retrospectively compared 33 consecutive cases treated with 18-mm-diameter stents (bridge to surgery [BTS] in 25, palliative therapy [PAL] in 8) with 27 consecutive cases treated with 22-mm-diameter stents (BTS in 21, PAL in 6) for obstructive colorectal cancer between May 2013 and November 2015 in our institution. RESULTS: There were no significant differences between the 18-mm and 22-mm groups in technical success rates (97 and 96%, respectively) and clinical success rates (100 and 100%, respectively). As a BTS, the rates of complications and stoma formation were not significantly different between groups. For PAL, although the rates of complications and stent patency were similar, stent occlusion occurred in 1 patient (12.5%) in the 18-mm group. CONCLUSIONS: The 18-mm-diameter stents were similarly effective when compared with 22-mm-diameter stents. Because 18-mm-diameter stents are easy to handle and produce less mechanical stress, they have the potential to decrease the perforation rate and mitigate the stent's impact on the tumors. 18-mm-diameter stents can be useful and safe, especially as a BTS.


Asunto(s)
Neoplasias Colorrectales/cirugía , Obstrucción Intestinal/cirugía , Stents , Anciano , Anciano de 80 o más Años , Neoplasias Colorrectales/patología , Bases de Datos Factuales , Procedimientos Quirúrgicos del Sistema Digestivo/instrumentación , Procedimientos Quirúrgicos del Sistema Digestivo/métodos , Estudios de Factibilidad , Femenino , Humanos , Obstrucción Intestinal/etiología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
19.
Nihon Hinyokika Gakkai Zasshi ; 108(2): 114-117, 2017.
Artículo en Japonés | MEDLINE | ID: mdl-29669975

RESUMEN

The patient was a 61-year old male on maintenance dialysis who underwent transrectal prostate biopsy due to a high PSA level. The patient started suffering from intense pain in the anal region 1 hour after the biopsy, and in 7 hours, intense lower abdominal pain and bilious vomiting developed. Progressive anemia was observed with a giant retroperitoneal hematoma which had partially extended intraperitoneally on a non-contrast CT image. These findings might have been caused by arterial bleeding which occurred during the prostate biopsy. The general condition was stable, and the symptoms were improved by blood transfusion and conservative treatments.

20.
Eur J Nucl Med Mol Imaging ; 43(9): 1653-63, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26902370

RESUMEN

PURPOSE: The histamine H3 receptors are presynaptic neuroreceptors that inhibit the release of histamine and other neurotransmitters. The receptors are considered a drug target for sleep disorders and neuropsychiatric disorders with cognitive decline. We developed a novel PET ligand for the H3 receptors, [(11)C]TASP0410457 ([(11)C]TASP457), with high affinity, selectivity and favorable kinetic properties in the monkey, and evaluated its kinetics and radiation safety profile for quantifying the H3 receptors in human brain. METHODS: Ten healthy men were scanned for 120 min with a PET scanner for brain quantification and three healthy men were scanned for radiation dosimetry after injection of 386 ± 6.2 MBq and 190 ± 7.5 MBq of [(11)C]TASP457, respectively. For brain quantification, arterial blood sampling and metabolite analysis were performed using high-performance liquid chromatography. Distribution volumes (V T) in brain regions were determined by compartment and graphical analyses using the Logan plot and Ichise multilinear analysis (MA1). For dosimetry, radiation absorbed doses were estimated using the Medical Internal Radiation Dose scheme. RESULTS: [(11)C]TASP457 PET showed high uptake (standardized uptake values in the range of about 3 - 6) in the brain and fast washout in cortical regions and slow washout in the pallidum. The two-tissue compartment model and graphical analyses estimated V T with excellent identification using 60-min scan data (about 16 mL/cm(3) in the pallidum, 9 - 14 in the basal ganglia, 6 - 9 in cortical regions, and 5 in the pons), which represents the known distribution of histamine H3 receptors. For parametric imaging, MA1 is recommended because of minimal underestimation with small intersubject variability. The organs with the highest radiation doses were the pancreas, kidneys, and liver. The effective dose delivered by [(11)C]TASP457 was 6.9 µSv/MBq. CONCLUSION: [(11)C]TASP457 is a useful novel PET ligand for the investigation of the density of histamine H3 receptors in human brain.


Asunto(s)
Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Radioisótopos de Carbono/metabolismo , Tomografía de Emisión de Positrones/métodos , Receptores Histamínicos H3/metabolismo , Adulto , Transporte Biológico , Radioisótopos de Carbono/sangre , Radioisótopos de Carbono/farmacocinética , Voluntarios Sanos , Humanos , Cinética , Ligandos , Masculino , Radiometría
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA