Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 172
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Phys Chem Chem Phys ; 26(16): 12738-12744, 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38618908

RESUMEN

Recently, hydrogen boride (HB) with a pseudo-two-dimensional sheet structure was successfully synthesized, and it is theoretically predicted to have high potential as a negative electrode material for alkali metal ion batteries, making it a promising new candidate. This study represents the first experimental examination of the negative electrode properties of HB. HB was synthesized via cation exchange from MgB2. The confirmation of HB synthesis was achieved through various spectroscopic experiments, including synchrotron radiation X-ray diffraction and X-ray photoelectron spectroscopy, in addition to direct observation using transmission electron microscopy. The HB electrode was prepared by mixing the HB powder sample with conductive additive carbon black and a polymer binder. A test cell was assembled with the HB electrode as the working electrode, and lithium metal as the counter and reference electrodes, and its battery electrode properties were evaluated. Although reversible charge-discharge curves with good reversibility were observed, the reversible capacity was 100 ± 20 mA h g-1 which is significantly smaller than the theoretical predictions. Nitrogen gas adsorption experiments were performed on the HB powder sample to determine the specific surface area indicating that the HB sheets were stacked together. It is plausible to consider that this stacking structure led to a reduced lithium-ion storage capacity compared to the theoretical predictions.

2.
Ann Vasc Surg ; 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-39025215

RESUMEN

OBJECTIVES: The association between the occlusion rate of the side branch arteries branching from the abdominal aortic aneurysm sac and aneurysm sac shrinkage is unclear. We aimed to evaluate the efficacy of preemptive embolization of multiple side branch arteries branching from the abdominal aortic aneurysm sac in early aneurysm sac shrinkage after endovascular aneurysm repair. METHODS: Patients undergoing endovascular aneurysm repair of abdominal aortic aneurysms, with or without preemptive embolization of multiple side branch arteries, including the inferior mesenteric artery and lumbar arteries, between January 2016 and August 2021, were retrospectively evaluated. Preemptive embolization was introduced at our institution in January 2018 and has been performed in all patients who undergo endovascular aneurysm repair since then. We compared occlusion rates of the side branch arteries, frequency of type 2 endoleaks, changes in aneurysm sac size, percentage of aneurysm sac size decrease, and frequency of reduction in the aneurysm sac diameter by >5 mm. RESULTS: The study included 43 patients in the embolization group and 20 in the non-embolization group. Preemptive embolization was successfully performed without any ischemic complications. The total occlusion rate of side branch arteries was significantly higher in the embolization group than in the non-embolization group (70.2% vs. 29.3%, P<0.05). At 24 months of follow-up, the type 2 endoleak frequency was significantly lower in the embolization group than in the non-embolization group (6.9% vs. 31.6%, P<0.05). The frequency of reduction in the aneurysm sac diameter by >5 mm was significantly higher in the embolization group than in the non-embolization group at 24 months (62.1% vs. 31.6% P<0.05). The optimal cutoff value for the total occlusion rate of the side branch arteries to achieve reduction in the aneurysm sac diameter by >5 mm at 24 months, after endovascular aneurysm repair, was 66.7% in all patients (area under the curve=0.634; sensitivity=62.5%; specificity=70.8%). These findings suggest that occluding 66.7% or more of the side branch arteries may result in early aneurysmal shrinkage. CONCLUSION: Preemptive embolization of multiple side branch arteries, branching from the abdominal aortic aneurysm sac, may contribute to early aneurysm sac shrinkage; this may serve as a marker for fewer late complications after endovascular aneurysm repair.

3.
Kyobu Geka ; 77(1): 50-54, 2024 Jan.
Artículo en Japonés | MEDLINE | ID: mdl-38459846

RESUMEN

Atrial fibrillation surgery is beneficial for restoring sinus rhythm and maintaining the physiological atrial contraction to prevent left atrial thrombus formation. The radial procedure, a good alternative to the maze procedure, has been performed at Nippon Medical School;it was designed to maintain physiological atrial excitation and blood flow. The design reduces the incision line and avoids conduction delay in the atrium through the use of ablation devices and intraoperative mapping of atrial excitation patterns. In addition, it preserves sinus node function and cardiac conduction pathway;this could prevent postoperative pacemaker implantation.


Asunto(s)
Fibrilación Atrial , Procedimientos Quirúrgicos Cardíacos , Ablación por Catéter , Humanos , Procedimiento de Laberinto , Facultades de Medicina , Atrios Cardíacos/cirugía , Fibrilación Atrial/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos
4.
Chemistry ; 29(70): e202302479, 2023 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-37720978

RESUMEN

The four phenyl groups of 1,1,3,3-tetraphenyl-2,2,4,4-tetrakis(trimethylsilyl)cyclotetrasilane were partially replaced by chlorine atom(s) by successive treatment with trifluoromethanesulfonic acid and lithium chloride. The replacement of all phenyl groups was carried out with hydrogen chloride in the presence of aluminum chloride. The structural features of the resulting mono-, di-, and tetrachlorocyclotetrasilanes were compared by X-ray crystallography.

5.
Somatosens Mot Res ; : 1-11, 2023 Dec 25.
Artículo en Inglés | MEDLINE | ID: mdl-38145411

RESUMEN

PURPOSE: This study aimed to identify the contribution of the common synaptic drives to motor units during obstacle avoidance, using coherence analysis between a-pair electromyography (EMG) signals (EMG-EMG coherence). MATERIALS AND METHODS: Fourteen healthy volunteers walked on a treadmill with and without obstacle avoidance. During obstacle gait, subjects were instructed to step over an obstacle with their right leg while walking that would randomly and unpredictably appear. Surface EMG signals were recorded from the following muscles of the right leg: the proximal and distal ends of tibialis anterior (TAp and TAd), biceps femoris (BF), semitendinosus (ST), lateral gastrocnemius (LG), and medial gastrocnemius (MG). Beta-band (13-30 Hz) EMG-EMG coherence was analysed. RESULTS: Beta-band EMG-EMG coherence of TAp-TAd during swing phase and BF-ST during pre and initial swing phase when stepping over an obstacle were significantly higher compared to normal gait (both p < 0.05). Beta-band EMG-EMG coherence of TAp-TAd, BF-ST, and LG-MG during stance phase were not significantly different between the two gait conditions (all p > 0.05). CONCLUSIONS: The present findings suggest increased common synaptic drives to motor units in ankle dorsiflexor and knee flexor muscles during obstacle avoidance. It also may reflect an increased cortical contribution to modify the gait patterns to avoid an obstacle.

6.
BMC Musculoskelet Disord ; 24(1): 272, 2023 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-37038148

RESUMEN

BACKGROUND: In the dynamic condition, knee osteoarthritis (OA) usually presents with pain. In the weight-bearing condition, a medial meniscus extrusion (MME) may cause severe symptoms and pathological progression. However, the correlation between a dynamic MME and pain has not been elucidated. Now, an MME can be evaluated under dynamic conditions and reflect the characteristics of symptomatic knee OA. This study investigated MMEs during walking and their correlation with knee pain. METHODS: Thirty-two symptomatic patients with knee OA (mean age, 60.5 ± 9.9 years) were enrolled in this study. The medial meniscus was evaluated using ultrasonograms during walking, and in the static supine and unipedal standing positions, as dynamic and static conditions, respectively. The ΔMME (the difference between the maximum and minimum MMEs) was obtained in each condition. The intensity of the knee pain during walking was measured by the visual analog scale (VAS). RESULTS: The ΔMME in the dynamic condition was significantly higher than that in the static condition (P < 0.01). There was a significant correlation between VAS and ΔMME only in the dynamic condition. CONCLUSIONS: The dynamic evaluation is a valid tool for understanding the mechanisms of knee pain and the behavior of the medial meniscus in symptomatic knee OA.


Asunto(s)
Articulación de la Rodilla , Meniscos Tibiales , Osteoartritis de la Rodilla , Meniscos Tibiales/diagnóstico por imagen , Meniscos Tibiales/patología , Imagen por Resonancia Magnética , Osteoartritis de la Rodilla/complicaciones , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/patología , Articulación de la Rodilla/diagnóstico por imagen , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano
7.
Circ J ; 87(1): 103-110, 2022 12 23.
Artículo en Inglés | MEDLINE | ID: mdl-36476494

RESUMEN

BACKGROUND: Although surgical approaches for infected or failing cardiac implantable electronic device (CIED) leads are more invasive than transvenous approaches, they are still required for patients considered unsuitable for transvenous procedures. In this study, surgical management with transvenous equipment for CIED complications was examined in patients unsuitable for transvenous lead extraction.Methods and Results: We retrospectively examined 152 consecutive patients who underwent CIED extraction between April 2009 and December 2021 at the Department of Cardiovascular Surgery, Nippon Medical School. Nine patients (5.9%; mean [±SD] age 61.7±16.7 years) who underwent open heart surgery were identified as unsuitable for the isolated transvenous approach. CIED types included 5 pacemakers and 4 implantable cardioverter-defibrillators; the mean [±SD] lead age was 19.5±7.0 years. Indications for surgical management according to Heart Rhythm Society guidelines included failed prior to transvenous CIED extraction (n=6), intracardiac vegetation (n=2), and severe lead adhesion (n=1). Transvenous CIED extraction tools were used in all patients during or before surgery. Additional surgical procedures with CIED extraction included epicardial lead implantation (n=4) and tricuspid valve repair (n=3). All patients were discharged; during the follow-up period (mean 5.7±3.7 years), only 1 patient died (non-cardiac cause). CONCLUSIONS: Surgical procedures and transvenous extraction tools were combined in the removal strategy for efficacious surgical management of CIED leads. Intensive surgical procedures were safely performed in patients unsuitable for transvenous extraction.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Desfibriladores Implantables , Marcapaso Artificial , Humanos , Persona de Mediana Edad , Anciano , Niño , Adolescente , Adulto Joven , Adulto , Estudios Retrospectivos , Resultado del Tratamiento , Desfibriladores Implantables/efectos adversos , Corazón , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Marcapaso Artificial/efectos adversos
8.
J Card Surg ; 37(4): 1028-1030, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35040518

RESUMEN

BACKGROUND: Four-dimensional flow magnetic resonance imaging (4D flow MRI) can directly estimate turbulent kinetic energy (TKE) which is associated with pressure loss that are not assessable by other imaging modalities. METHODS AND RESULTS: A 55-year-old woman developed hemolytic anemia after emergency ascending aortic replacement for acute type A aortic dissection. Although computed tomographic angiography or doppler echocardiography could not identify the culprit stenotic legion, 4D flow MRI revealed jet flow and highly elevated TKE at the highly stenosed proximal anastomosis of a replaced ascending aorta. CONCLUSION: Our findings suggest that 4D flow MRI evaluation and TKE estimation enable more accurate and detailed assessment of abnormal flow dynamics than conventional imaging modalities.


Asunto(s)
Anemia Hemolítica , Disección Aórtica , Anemia Hemolítica/etiología , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Aorta/diagnóstico por imagen , Aorta/cirugía , Velocidad del Flujo Sanguíneo , Femenino , Humanos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Persona de Mediana Edad
9.
Int J Mol Sci ; 23(24)2022 Dec 17.
Artículo en Inglés | MEDLINE | ID: mdl-36555746

RESUMEN

Kawasaki disease (KD) is an acute inflammatory syndrome of unknown etiology that is complicated by cardiovascular sequelae. Chronic inflammation (vasculitis) due to KD might cause vascular cellular senescence and vascular endothelial cell damage, and is a potential cause of atherosclerosis in young adults. This study examined the effect of KD and HMG-CoA inhibitors (statins) on vascular cellular senescence and vascular endothelial cells. Candida albicans water-soluble fraction (CAWS) was administered intraperitoneally to 5-week-old male apolipoprotein E-deficient (ApoE-) mice to induce KD-like vasculitis. The mice were then divided into three groups: control, CAWS, and CAWS+statin groups. Ten weeks after injection, the mice were sacrificed and whole aortic tissue specimens were collected. Endothelial nitric oxide synthase (eNOS) expression in the ascending aortic intima epithelium was evaluated using immunostaining. In addition, eNOS expression and levels of cellular senescence markers were measured in RNA and proteins extracted from whole aortic tissue. KD-like vasculitis impaired vascular endothelial cells that produce eNOS, which maintains vascular homeostasis, and promoted macrophage infiltration into the tissue. Statins also restored vascular endothelial cell function by promoting eNOS expression. Statins may be used to prevent secondary cardiovascular events during the chronic phase of KD.


Asunto(s)
Aterosclerosis , Inhibidores de Hidroximetilglutaril-CoA Reductasas , Síndrome Mucocutáneo Linfonodular , Vasculitis , Masculino , Ratones , Animales , Síndrome Mucocutáneo Linfonodular/metabolismo , Inhibidores de Hidroximetilglutaril-CoA Reductasas/farmacología , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Células Endoteliales/metabolismo , Vasculitis/etiología , Aterosclerosis/etiología , Aterosclerosis/complicaciones , Óxido Nítrico Sintasa de Tipo III/metabolismo
10.
J Stroke Cerebrovasc Dis ; 31(8): 106593, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35696736

RESUMEN

BACKGROUND: Postoperative cerebral embolic stroke is a serious complication of pulmonary lobectomy, occurring in 1.1% of patients undergoing lobectomy through video-assisted thoracoscopic surgery (VATS). The mechanism of this complication is thought to be embolic stroke caused by thrombus formed due to stagnation in the pulmonary vein stump after VATS lobectomy. There have been few reports demonstrating the utility of endovascular treatment (EVT) for cerebral embolic stroke after VATS lobectomy. CASE DESCRIPTION: In our case series, cerebral embolic stroke occurred after VATS pulmonary lobectomy for lung cancer, including the left upper lobe in three cases and the right lobe in one. The median duration of ischemic stroke after VATS was 4.5 days (interquartile range, 2-9 days). The median time from stroke onset to puncture was 130 min. Successful recanalization was achieved in all cases, and two patients achieved favorable clinical outcomes (modified Rankin scale, 0-2). CONCLUSION: We report a case series of four patients who underwent EVT for acute embolic stroke after VATS lobectomy for lung cancer. EVT is considered a reasonable and feasible therapeutic option for this condition.


Asunto(s)
Accidente Cerebrovascular Embólico , Accidente Cerebrovascular Isquémico , Neoplasias Pulmonares , Accidente Cerebrovascular , Humanos , Neoplasias Pulmonares/complicaciones , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/cirugía , Neumonectomía/efectos adversos , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/terapia , Cirugía Torácica Asistida por Video/efectos adversos
11.
Neuroimage ; 233: 117955, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33716155

RESUMEN

Cerebrovascular reactivity (CVR) reflects the capacity of the brain to meet changing physiological demands and can predict the risk of cerebrovascular diseases. CVR can be obtained by measuring the change in cerebral blood flow (CBF) during a brain stress test where CBF is altered by a vasodilator such as acetazolamide. Although the gold standard to quantify CBF is PET imaging, the procedure is invasive and inaccessible to most patients. Arterial spin labeling (ASL) is a non-invasive and quantitative MRI method to measure CBF, and a consensus guideline has been published for the clinical application of ASL. Despite single post labeling delay (PLD) pseudo-continuous ASL (PCASL) being the recommended ASL technique for CBF quantification, it is sensitive to variations to the arterial transit time (ATT) and labeling efficiency induced by the vasodilator in CVR studies. Multi-PLD ASL controls for the changes in ATT, and velocity selective ASL is in theory insensitive to both ATT and labeling efficiency. Here we investigate CVR using simultaneous 15O-water PET and ASL MRI data from 19 healthy subjects. CVR and CBF measured by the ASL techniques were compared using PET as the reference technique. The impacts of blood T1 and labeling efficiency on ASL were assessed using individual measurements of hematocrit and flow velocity data of the carotid and vertebral arteries measured using phase-contrast MRI. We found that multi-PLD PCASL is the ASL technique most consistent with PET for CVR quantification (group mean CVR of the whole brain = 42±19% and 40±18% respectively). Single-PLD ASL underestimated the CVR of the whole brain significantly by 15±10% compared with PET (p<0.01, paired t-test). Changes in ATT pre- and post-acetazolamide was the principal factor affecting ASL-based CVR quantification. Variations in labeling efficiency and blood T1 had negligible effects.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Encéfalo/metabolismo , Trastornos Cerebrovasculares/metabolismo , Imagen por Resonancia Magnética/normas , Tomografía de Emisión de Positrones/normas , Marcadores de Spin , Adulto , Anciano , Encéfalo/diagnóstico por imagen , Circulación Cerebrovascular/fisiología , Trastornos Cerebrovasculares/diagnóstico por imagen , Femenino , Hematócrito/métodos , Hematócrito/normas , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Radioisótopos de Oxígeno/metabolismo , Tomografía de Emisión de Positrones/métodos , Factores de Tiempo , Agua/metabolismo
12.
Muscle Nerve ; 64(5): 610-613, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34378200

RESUMEN

INTRODUCTION/AIMS: The treatment of entrapment neuropathies, such as carpal tunnel syndrome or cubital tunnel syndrome, has significant challenges that have yet to be solved. To a large extent, the success of the treatment of peripheral nerve damage is dependent on brain plasticity during the recovery process. Recently, noninvasive brain stimulation procedures, such as transcranial direct current stimulation (tDCS), to modulate brain activity have been developed. This study aimed to determine whether tDCS can improve artificially induced ischemic sensory disturbances in the finger. METHODS: Ten right-handed, healthy volunteers, with an average age of 25.5 years, participated in this study. A rubber bandage at the base of the right index finger was used to induce a regional sensory disturbance for 30 minutes. An anodal tDCS was applied over their left M1 area 15 minutes into the session. The current perception threshold (CPT) in the index and little finger pad was evaluated using the PainVision system and used as a measure of the sensory threshold. RESULTS: In the index finger, the CPT increased significantly with time, a finding that was absent after tDCS application. DISCUSSION: It has been reported that anodal tDCS over M1 primarily modulates the functional connectivity of sensory networks, and our findings demonstrate that it improved ischemia-induced sensory disturbances. Modulating the central nervous system using tDCS represents a potential avenue for treating entrapment neuropathies.


Asunto(s)
Estimulación Transcraneal de Corriente Directa , Adulto , Voluntarios Sanos , Humanos , Isquemia/complicaciones , Isquemia/terapia , Plasticidad Neuronal/fisiología , Umbral Sensorial , Estimulación Transcraneal de Corriente Directa/métodos
13.
Ann Vasc Surg ; 75: 205-216, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33819584

RESUMEN

BACKGROUND: To evaluate outcomes of endovascular treatment (EVT) using a combination of multiple endovascular techniques for acute lower limb ischemia (ALLI) and to compare outcomes based on vessel type and artery location. METHODS: A total of 95 consecutive patients with ALLI (mean age, 72.0 years; 65 males; 104 lower limbs) who received emergency EVT using a combination of multiple endovascular techniques including thrombolysis, aspiration thrombectomy, stenting, and balloon angioplasty with or without surgical thromboembolectomy, between January 2005 and December 2017 were included. Vessel type was classified into native artery occlusion (native occlusion) and bypass graft occlusion (graft occlusion), including prosthetic and vein graft. Additionally, native arteries were categorized into below-knee occlusion and non-below-knee occlusion. Technical success, perioperative death (POD), ALLI-related death, amputation, amputation-free survival (AFS), and complications were compared according to vessel type (native occlusion vs. graft occlusion) and artery location (below-knee occlusion vs. non-below-knee occlusion). RESULTS: Of all patients with ALLI, 16.8% underwent a single endovascular technique, whereas 83.2% underwent a combination of multiple endovascular techniques. The technicalsuccess, POD, and ALLI-related death rates in the total number of patients were 94.7%, 11.6%, and 4.2%, respectively. A total of 67 patients (75 limbs) and 28 patients (29 limbs) were classified as having native occlusion and graft occlusion (prosthetic, 24 limbs; vein, 5 limbs), respectively. No significant differences in technical success (native occlusion: 92.5% vs. graft occlusion: 100%), POD (14.9% vs. 3.6%), and ALLI-related death (6.0% vs. 0%) were noted between native occlusion and graft occlusion. However, the 30-day AFS rate of native occlusion was significantly lower than that of graft occlusion (75.2% vs. 96.3%, P=0.01). The amputation rate (P=0.03) and AFS rate (P=0.03) of below-knee occlusion were significantly worse for below-knee occlusion patients than for non-below-knee occlusion patients. CONCLUSIONS: EVT using multiple endovascular techniques for ALLI is effective and safe. A combination of multiple endovascular techniques is crucial for successful treatment. However, native occlusion may have a lower AFS rate than graft occlusion, and below-knee occlusion may have a higher risk of amputation than non-below-knee occlusion.


Asunto(s)
Implantación de Prótesis Vascular , Procedimientos Endovasculares , Oclusión de Injerto Vascular/cirugía , Isquemia/cirugía , Pierna/irrigación sanguínea , Enfermedad Arterial Periférica/cirugía , Venas/trasplante , Enfermedad Aguda , Adulto , Anciano , Anciano de 80 o más Años , Amputación Quirúrgica , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Oclusión de Injerto Vascular/diagnóstico por imagen , Oclusión de Injerto Vascular/mortalidad , Oclusión de Injerto Vascular/fisiopatología , Humanos , Isquemia/diagnóstico por imagen , Isquemia/mortalidad , Isquemia/fisiopatología , Recuperación del Miembro , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/mortalidad , Enfermedad Arterial Periférica/fisiopatología , Supervivencia sin Progresión , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Grado de Desobstrucción Vascular , Venas/diagnóstico por imagen , Venas/fisiopatología
14.
Neuroimage ; 220: 117136, 2020 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-32634594

RESUMEN

Oxygen extraction fraction (OEF) and the cerebral metabolic rate of oxygen (CMRO2) are key cerebral physiological parameters to identify at-risk cerebrovascular patients and understand brain health and function. PET imaging with [15O]-oxygen tracers, either through continuous or bolus inhalation, provides non-invasive assessment of OEF and CMRO2. Numerous tracer delivery, PET acquisition, and kinetic modeling approaches have been adopted to map brain oxygenation. The purpose of this technical review is to critically evaluate different methods for [15O]-gas PET and its impact on the accuracy and reproducibility of OEF and CMRO2 measurements. We perform a meta-analysis of brain oxygenation PET studies in healthy volunteers and compare between continuous and bolus inhalation techniques. We also describe OEF metrics that have been used to detect hemodynamic impairment in cerebrovascular disease. For these patients, advanced techniques to accelerate the PET scans and potential synthesis with MRI to avoid arterial blood sampling would facilitate broader use of [15O]-oxygen PET for brain physiological assessment.


Asunto(s)
Encéfalo/metabolismo , Consumo de Oxígeno/fisiología , Oxígeno/metabolismo , Tomografía de Emisión de Positrones/métodos , Encéfalo/diagnóstico por imagen , Humanos
15.
Radiology ; 296(3): 627-637, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32662761

RESUMEN

Background Cerebrovascular reserve (CVR) may be measured by using an acetazolamide test to clinically evaluate patients with cerebrovascular disease. However, acetazolamide use may be contraindicated and/or undesirable in certain clinical settings. Purpose To predict CVR images generated from acetazolamide vasodilation with a deep learning network by using only images before acetazolamide administration. Materials and Methods Simultaneous oxygen 15 (15O)-labeled water PET/MRI before and after acetazolamide injection were retrospectively analyzed for patients with Moyamoya disease and healthy control participants from April 2017 to May 2019. Inputs to deep learning models were perfusion-based images (arterial spin labeling [ASL]), structural scans (T2 fluid-attenuated inversion-recovery, T1), and brain location. Two models, that is, 15O-labeled water PET cerebral blood flow (CBF) and MRI (PET-plus-MRI model) before acetazolamide administration and only MRI (MRI-only model) before acetazolamide administration, were trained and tested with sixfold cross-validation. The models learned to predict a voxelwise relative CBF change (rΔCBF) map by using rΔCBF measured with PET due to acetazolamide as ground truth. Quantitative analysis included image quality metrics (peak signal-to-noise ratio, root mean square error, and structural similarity index), as well as comparison between the various methods by using correlation and Bland-Altman analyses. Identification of vascular territories with impaired rΔCBF was evaluated by using receiver operating characteristic metrics. Results Thirty-six participants were included: 24 patients with Moyamoya disease (mean age ± standard deviation, 41 years ± 12; 17 women) and 12 age-matched healthy control participants (mean age, 39 years ± 16; nine women). The rΔCBF maps predicted by both deep learning models demonstrated better image quality metrics than did ASL (all P < .001 in patients) and higher correlation coefficient with PET than with ASL (PET-plus-MRI model, 0.704; MRI-only model, 0.690 vs ASL, 0.432; both P < .001 in patients). Both models also achieved high diagnostic performance in identifying territories with impaired rΔCBF (area under receiver operating characteristic curve, 0.95 for PET-plus-MRI model [95% confidence interval: 0.90, 0.99] and 0.95 for MRI-only model [95% confidence interval: 0.91, 0.98]). Conclusion By using only images before acetazolamide administration, PET-plus-MRI and MRI-only deep learning models predicted cerebrovascular reserve images without the need for vasodilator injection. © RSNA, 2020 Online supplemental material is available for this article.


Asunto(s)
Encéfalo/irrigación sanguínea , Encéfalo/diagnóstico por imagen , Aprendizaje Profundo , Imagen por Resonancia Magnética/métodos , Tomografía de Emisión de Positrones/métodos , Adolescente , Adulto , Circulación Cerebrovascular/fisiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermedad de Moyamoya/diagnóstico por imagen , Proyectos Piloto , Adulto Joven
16.
J Magn Reson Imaging ; 51(1): 183-194, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31044459

RESUMEN

BACKGROUND: H215 O-positron emission tomography (PET) is considered the reference standard for absolute cerebral blood flow (CBF). However, this technique requires an arterial input function measured through continuous sampling of arterial blood, which is invasive and has limitations with tracer delay and dispersion. PURPOSE: To demonstrate a new noninvasive method to quantify absolute CBF with a PET/MRI hybrid scanner. This blood-free approach, called PC-PET, takes the spatial CBF distribution from a static H215 O-PET scan, and scales it to the whole-brain average CBF value measured by simultaneous phase-contrast MRI. STUDY TYPE: Observational. SUBJECTS: Twelve healthy controls (HC) and 13 patients with Moyamoya disease (MM) as a model of chronic ischemic disease. FIELD STRENGTH/SEQUENCES: 3T/2D cardiac-gated phase-contrast MRI and H215 O-PET. ASSESSMENT: PC-PET CBF values from whole brain (WB), gray matter (GM), and white matter (WM) in HCs were compared with literature values since 2000. CBF and cerebrovascular reactivity (CVR), which is defined as the percent CBF change between baseline and post-acetazolamide (vasodilator) scans, were measured by PC-PET in MM patients and HCs within cortical regions corresponding to major vascular territories. Statistical Tests: Linear, mixed effects models were created to compare CBF and CVR, respectively, between patients and controls, and between different degrees of stenosis. RESULTS: The mean CBF values in WB, GM, and WM in HC were 42 ± 7 ml/100 g/min, 50 ± 7 ml/100 g/min, and 23 ± 3 ml/100 g/min, respectively, which agree well with literature values. Compared with normal regions (57 ± 23%), patients showed significantly decreased CVR in areas with mild/moderate stenosis (47 ± 17%, P = 0.011) and in severe/occluded areas (40 ± 16%, P = 0.016). Data Conclusion: PC-PET identifies differences in cerebrovascular reactivity between healthy controls and cerebrovascular patients. PC-PET is suitable for CBF measurement when arterial blood sampling is not accessible, and warrants comparison to fully quantitative H215 O-PET in future studies. LEVEL OF EVIDENCE: 3 Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2019. J. Magn. Reson. Imaging 2020;51:183-194.


Asunto(s)
Circulación Cerebrovascular/fisiología , Imagen por Resonancia Magnética/métodos , Enfermedad de Moyamoya/diagnóstico por imagen , Enfermedad de Moyamoya/fisiopatología , Imagen Multimodal/métodos , Tomografía de Emisión de Positrones/métodos , Adulto , Encéfalo/diagnóstico por imagen , Encéfalo/fisiopatología , Femenino , Humanos , Masculino , Radioisótopos de Oxígeno
17.
J Neuroeng Rehabil ; 17(1): 113, 2020 08 20.
Artículo en Inglés | MEDLINE | ID: mdl-32819412

RESUMEN

BACKGROUND: Regular body-powered (BP) prosthesis training facilitates the acquisition of skills through repeated practice but requires adequate time and motivation. Therefore, auxiliary tools such as indirect training may improve the training experience and speed of skill acquisition. In this study, we examined the effects of action observation (AO) using virtual reality (VR) as an auxiliary tool. We used two modalities during AO: three-dimensional (3D) VR and two-dimensional (2D) computer tablet devices (Tablet). Each modality was tested from first- and third-person perspectives. METHODS: We studied 40 healthy right-handed participants wearing a BP prosthesis simulator on their non-dominant hands. The participants were divided into five groups based on combinations of the different modalities and perspectives: first-person perspective on VR (VR1), third-person perspective on VR (VR3), first-person perspective on a tablet (Tablet1), third-person perspective on a tablet (Tablet3), and a control group (Control). The intervention groups observed and imitated the video image of prosthesis operation for 10 min in each of two sessions. We evaluated the level of immersion during AO using the visual analogue scale. Prosthetic control skills were evaluated using the Box and Block Test (BBT) and a bowknot task (BKT). RESULTS: In the BBT, there were no significant differences in the amount of change in the skills between the five groups. In contrast, the relative changes in the BKT prosthetic control skills in VR1 (p < 0.001, d = 3.09) and VR3 (p < 0.001, d = 2.16) were significantly higher than those in the control group. Additionally, the immersion scores of VR1 (p < 0.05, d = 1.45) and VR3 (p < 0.05, d = 1.18) were higher than those of Tablet3. There was a significant negative correlation between the immersion scores and the relative change in the BKT scores (Spearman's rs = - 0.47, p < 0.01). CONCLUSIONS: Using the BKT of bilateral manual dexterity, VR-based AO significantly improved short-term prosthetic control acquisition. Additionally, it appeared that the higher the immersion score was, the shorter the execution time of the BKT task. Our findings suggest that VR-based AO training may be effective in acquiring bilateral BP prosthetic control, which requires more 3D-based operation.


Asunto(s)
Modalidades de Fisioterapia , Realidad Virtual , Adulto , Amputados/rehabilitación , Miembros Artificiales , Computadoras de Mano , Femenino , Voluntarios Sanos , Humanos , Masculino , Modalidades de Fisioterapia/instrumentación , Interfaz Usuario-Computador , Adulto Joven
18.
J Orthop Sci ; 25(4): 640-646, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31350063

RESUMEN

BACKGROUND: Lateral thrust is known to be risk factors for knee osteoarthritis progression. Medial meniscus extrusion is also known to be risk factors for knee osteoarthritis progression; moreover, the amount of change in medial meniscus extrusion from non-weight bearing to weight bearing is an important factor for the progression of knee osteoarthritis. This study aimed to investigate the correlation between lateral thrust and the change in medial meniscus extrusion. METHODS: In total, 44 knees from 44 patients (mean age, 68.9 years) with knee osteoarthritis were divided into two groups according to the Kellgren-Lawrence grade: early-stage osteoarthritis (Kellgren-Lawrence = 2) and severe osteoarthritis (Kellgren-Lawrence = 3 or 4). The lateral thrust during gait, represented as the lateral acceleration peak immediately after heel strike, was recorded by an inertial sensor. The amount of change in medial meniscus extrusion, which was the difference between weight-bearing (unipedal standing) and non-weight-bearing (supine) conditions, was evaluated using ultrasonography. RESULTS: The mean value of the lateral acceleration peak in the severe osteoarthritis group was higher than that of the early-stage osteoarthritis group (p < 0.05). The non-weight-bearing and weight-bearing medial meniscus extrusion in the severe OA group were significantly higher than those of the early-stage osteoarthritis group (p < 0.001). However, the amount of change in medial meniscus extrusion in severe osteoarthritis group was significantly lower than in the early-stage osteoarthritis group (p < 0.05). The amount of change in medial meniscus extrusion showed a significant correlation with the lateral acceleration peak in the early-stage osteoarthritis group (r = 0.56, p < 0.001). On the other hand, there was no significant correlation in the severe osteoarthritis group. CONCLUSION: The lateral thrust shows a positive correlation with the amount of change in medial meniscus extrusion by weight bearing in patients with early-stage knee osteoarthritis.


Asunto(s)
Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/fisiopatología , Lesiones de Menisco Tibial/diagnóstico por imagen , Lesiones de Menisco Tibial/fisiopatología , Anciano , Progresión de la Enfermedad , Femenino , Marcha/fisiología , Humanos , Masculino , Persona de Mediana Edad , Factores de Riesgo , Ultrasonografía , Soporte de Peso
19.
Stroke ; 50(2): 373-380, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30636572

RESUMEN

Background and Purpose- Noninvasive imaging of brain perfusion has the potential to elucidate pathophysiological mechanisms underlying Moyamoya disease and enable clinical imaging of cerebral blood flow (CBF) to select revascularization therapies for patients. We used hybrid positron emission tomography (PET)/magnetic resonance imaging (MRI) technology to characterize the distribution of hypoperfusion in Moyamoya disease and its relationship to vessel stenosis severity, through comparisons with a normative perfusion database of healthy controls. Methods- To image CBF, we acquired [15O]-water PET as a reference and simultaneously acquired arterial spin labeling (ASL) MRI scans in 20 Moyamoya patients and 15 age-matched, healthy controls on a PET/MRI scanner. The ASL MRI scans included a standard single-delay ASL scan with postlabel delay of 2.0 s and a multidelay scan with 5 postlabel delays (0.7-3.0s) to estimate and account for arterial transit time in CBF quantification. The percent volume of hypoperfusion in patients (determined as the fifth percentile of CBF values in the healthy control database) was the outcome measure in a logistic regression model that included stenosis grade and location. Results- Logistic regression showed that anterior ( P<0.0001) and middle cerebral artery territory regions ( P=0.003) in Moyamoya patients were susceptible to hypoperfusion, whereas posterior regions were not. Cortical regions supplied by arteries with stenosis on MR angiography showed more hypoperfusion than normal arteries ( P=0.001), but the extent of hypoperfusion was not different between mild-moderate versus severe stenosis. Multidelay ASL did not perform differently from [15O]-water PET in detecting perfusion abnormalities, but standard ASL overestimated the extent of hypoperfusion in patients ( P=0.003). Conclusions- This simultaneous PET/MRI study supports the use of multidelay ASL MRI in clinical evaluation of Moyamoya disease in settings where nuclear medicine imaging is not available and application of a normative perfusion database to automatically identify abnormal CBF in patients.


Asunto(s)
Bases de Datos Factuales , Imagen por Resonancia Magnética , Arteria Cerebral Media , Enfermedad de Moyamoya , Tomografía de Emisión de Positrones , Adolescente , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Arteria Cerebral Media/diagnóstico por imagen , Arteria Cerebral Media/fisiopatología , Enfermedad de Moyamoya/diagnóstico por imagen , Enfermedad de Moyamoya/fisiopatología , Marcadores de Spin
20.
Surg Today ; 49(2): 124-129, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30178212

RESUMEN

PURPOSE: We examined the outcome of modified-maze procedures reflecting a single-center strategy in the treatment of atrial fibrillation (AF) associated with atrial septal defect (ASD) in adults. METHODS: A retrospective chart review was performed for 29 patients who underwent surgical ASD closure and 2 types of maze procedures (full and simplified maze procedures) for AF. The outcome related to the each procedure was examined. A Cox proportional hazards analysis was performed to assess the independent predictors of AF and atrial tachycardia (AT) recurrence. RESULTS: The rates of freedom from AF and AT recurrence at 1 and 4 years were 86.6% and 72.2% in the full maze group and 78.5% and 62.8% in the simplified maze group, respectively (p = 0.70). The only risk factor for recurrence was the age at the time of surgery. A receiver operating characteristic curve analysis gave an optimum cut-off value of 58 years of age for predicting recurrence within 2 years (58.4% for ≥ 58 years versus 5.9% for < 58 years, p = 0.003). CONCLUSIONS: Simplification of the maze procedure was not associated with AF or AT recurrence. The age at the time of surgery might be a clinical predictor of success or failure in adult patients.


Asunto(s)
Fibrilación Atrial/etiología , Fibrilación Atrial/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos , Defectos del Tabique Interatrial/complicaciones , Defectos del Tabique Interatrial/cirugía , Adulto , Factores de Edad , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Curva ROC , Ablación por Radiofrecuencia , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA