Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 204
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Circulation ; 147(9): 759-767, 2023 02 28.
Artículo en Inglés | MEDLINE | ID: mdl-36848410

RESUMEN

The notion that the risk of sudden cardiac death (SCD) in patients with heart failure (HF) is declining seems to be gaining traction. Numerous editorials and commentaries have suggested that SCD, specifically arrhythmic SCD, is no longer a significant risk for patients with HF on guideline-directed medical therapy. In this review, we question whether the risk of SCD has indeed declined in HF trials and in the real world. We also explore whether, despite relative risk reductions, the residual SCD risk after guideline-directed medical therapy still suggests a need for implantable cardioverter defibrillator therapy. Among our arguments is that SCD has not decreased in HF trials, nor in the real world. Moreover, we argue that data from HF trials, which have not adhered to guideline-directed device therapy, do not obviate or justify delays to implantable cardioverter defibrillator therapy. In this context, we underline the challenges of translating the findings of HF randomized, controlled trials of guideline-directed medical therapy to the real world. We also make the case for HF trials that adhere to current guideline-directed device therapy so that we can better understand the role of implantable cardioverter defibrillators in chronic HF.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/terapia , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control
2.
Cerebrovasc Dis ; 53(1): 115-124, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37276846

RESUMEN

INTRODUCTION: The World Stroke Organization (WSO) Brain & Heart Task Force developed the Brain & hEart globAl iniTiative (BEAT), a pilot feasibility implementation program to establish clinical collaborations between cardiologists and stroke physicians who work at large healthcare facilities. METHODS: The WSO BEAT pilot project focused on atrial fibrillation (AF) and patent foramen ovale (PFO) detection and management, and poststroke cardiovascular complications known as the stroke-heart syndrome. The program included 10 sites from 8 countries: Brazil, China, Egypt, Germany, Japan, Mexico, Romania, and the USA The primary composite feasibility outcome was the achievement of the following 3 implementation metrics (1) developing site-specific clinical pathways for the diagnosis and management of AF, PFO, and the stroke-heart syndrome; (2) establishing regular Neurocardiology rounds (e.g., monthly); and (3) incorporating a cardiologist to the stroke team. The secondary objectives were (1) to identify implementation challenges to guide a larger program and (2) to describe qualitative improvements. RESULTS: The WSO BEAT pilot feasibility program achieved the prespecified primary composite outcome in 9 of 10 (90%) sites. The most common challenges were the limited access to specific medications (e.g., direct oral anticoagulants) and diagnostic (e.g., prolonged cardiac monitoring) or therapeutic (e.g., PFO closure devices) technologies. The most relevant qualitative improvement was the achievement of a more homogeneous diagnostic and therapeutic approach. CONCLUSION: The WSO BEAT pilot program suggests that developing neurocardiology collaborations is feasible. The long-term sustainability of the WSO BEAT program and its impact on quality of stroke care and clinical outcomes needs to be tested in a larger and longer duration program.


Asunto(s)
Fibrilación Atrial , Foramen Oval Permeable , Accidente Cerebrovascular , Humanos , Proyectos Piloto , Factores de Riesgo , Cateterismo Cardíaco/efectos adversos , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/terapia , Accidente Cerebrovascular/etiología , Foramen Oval Permeable/diagnóstico , Foramen Oval Permeable/diagnóstico por imagen , Fibrilación Atrial/diagnóstico , Prevención Secundaria , Encéfalo , Resultado del Tratamiento , Recurrencia
3.
Europace ; 26(6)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38918179

RESUMEN

AIMS: Persistent reluctance to perform magnetic resonance imaging (MRI) in patients with abandoned and/or epicardial leads of cardiac implantable electronic devices is related to in vitro studies reporting tip heating. While there is a plethora of data on the safety of MRI in conditional and non-conditional implantable devices, there is a clear lack of safety data in patients with abandoned and/or epicardial leads. METHODS AND RESULTS: Relevant literature was identified in Medline and CINAHL using the key terms 'magnetic resonance imaging' AND 'abandoned leads' OR 'epicardial leads'. Secondary literature and cross-references were supplemented. For reporting guidance, the Preferred Reporting Items for Systematic reviews and Meta-Analyses 2020 was used. International Prospective Register of Systematic Reviews (PROSPERO) registration number 465530. Twenty-one publications with a total of 656 patients with 854 abandoned and/or epicardial leads and 929 MRI scans of different anatomical regions were included. No scan-related major adverse cardiac event was documented, although the possibility of under-reporting of critical events in the literature should be considered. Furthermore, no severe device dysfunction or severe arrhythmia was reported. Mainly transient lead parameter changes were observed in 2.8% in the subgroup of patients with functional epicardial leads. As a possible correlate of myocardial affection, subjective sensations occurred mainly in the subgroup with abandoned epicardial leads (4.0%), but no change in myocardial biomarkers was observed. CONCLUSION: Existing publications did not report any relevant adverse events for MRI in patients with abandoned and/or epicardial leads if performed according to strict safety guidelines. However, a more rigorous risk-benefit calculation should be made for patients with epicardial leads.


Asunto(s)
Desfibriladores Implantables , Imagen por Resonancia Magnética , Marcapaso Artificial , Humanos , Imagen por Resonancia Magnética/efectos adversos , Seguridad del Paciente
4.
Europace ; 25(4): 1208-1236, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-37061848

RESUMEN

Conduction system pacing (CSP) has emerged as a more physiological alternative to right ventricular pacing and is also being used in selected cases for cardiac resynchronization therapy. His bundle pacing was first introduced over two decades ago and its use has risen over the last five years with the advent of tools which have facilitated implantation. Left bundle branch area pacing is more recent but its adoption is growing fast due to a wider target area and excellent electrical parameters. Nevertheless, as with any intervention, proper technique is a prerequisite for safe and effective delivery of therapy. This document aims to standardize the procedure and to provide a framework for physicians who wish to start CSP implantation, or who wish to improve their technique.


Asunto(s)
Terapia de Resincronización Cardíaca , Sistema de Conducción Cardíaco , Humanos , América Latina , Canadá , Trastorno del Sistema de Conducción Cardíaco , Fascículo Atrioventricular
5.
Europace ; 25(4): 1237-1248, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-37061850

RESUMEN

Conduction system pacing (CSP) has emerged as a more physiological alternative to right ventricular pacing and is also being used in selected cases for cardiac resynchronization therapy. His bundle pacing was first introduced over two decades ago and its use has risen over the last years with the advent of tools which have facilitated implantation. Left bundle branch area pacing is more recent but its adoption is growing fast due to a wider target area and excellent electrical parameters. Nevertheless, as with any intervention, proper technique is a prerequisite for safe and effective delivery of therapy. This document aims to standardize the procedure and to provide a framework for physicians who wish to start CSP implantation, or who wish to improve their technique. A synopsis is provided in this print edition of EP-Europace. The full document may be consulted online, and a 'Key Messages' App can be downloaded from the EHRA website.


Asunto(s)
Sistema de Conducción Cardíaco , Humanos , Canadá , Trastorno del Sistema de Conducción Cardíaco , Asia
6.
Europace ; 25(3): 1077-1086, 2023 03 30.
Artículo en Inglés | MEDLINE | ID: mdl-36352513

RESUMEN

Guidelines recommend patients undergoing a first pacemaker implant who have even mild left ventricular (LV) impairment should receive biventricular or conduction system pacing (CSP). There is no corresponding recommendation for patients who already have a pacemaker. We conducted a meta-analysis of randomized controlled trials (RCTs) and observational studies assessing device upgrades. The primary outcome was the echocardiographic change in LV ejection fraction (LVEF). Six RCTs (randomizing 161 patients) and 47 observational studies (2644 patients) assessing the efficacy of upgrade to biventricular pacing were eligible for analysis. Eight observational studies recruiting 217 patients of CSP upgrade were also eligible. Fourteen additional studies contributed data on complications (25 412 patients). Randomized controlled trials of biventricular pacing upgrade showed LVEF improvement of +8.4% from 35.5% and observational studies: +8.4% from 25.7%. Observational studies of left bundle branch area pacing upgrade showed +11.1% improvement from 39.0% and observational studies of His bundle pacing upgrade showed +12.7% improvement from 36.0%. New York Heart Association class decreased by -0.4, -0.8, -1.0, and -1.2, respectively. Randomized controlled trials of biventricular upgrade found improvement in Minnesota Heart Failure Score (-6.9 points) and peak oxygen uptake (+1.1 mL/kg/min). This was also seen in observational studies of biventricular upgrades (-19.67 points and +2.63 mL/kg/min, respectively). In studies of the biventricular upgrade, complication rates averaged 2% for pneumothorax, 1.4% for tamponade, and 3.7% for infection over 24 months of mean follow-up. Lead-related complications occurred in 3.3% of biventricular upgrades and 1.8% of CSP upgrades. Randomized controlled trials show significant physiological and symptomatic benefits of upgrading pacemakers to biventricular pacing. Observational studies show similar effects between biventricular pacing upgrade and CSP upgrade.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Marcapaso Artificial , Disfunción Ventricular Izquierda , Humanos , Terapia de Resincronización Cardíaca/efectos adversos , Estimulación Cardíaca Artificial/efectos adversos , Trastorno del Sistema de Conducción Cardíaco/terapia , Sistema de Conducción Cardíaco , Función Ventricular Izquierda , Volumen Sistólico/fisiología , Resultado del Tratamiento , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia
7.
Europace ; 25(4): 1249-1276, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-37061780

RESUMEN

There is an increasing proportion of the general population surviving to old age with significant chronic disease, multi-morbidity, and disability. The prevalence of pre-frail state and frailty syndrome increases exponentially with advancing age and is associated with greater morbidity, disability, hospitalization, institutionalization, mortality, and health care resource use. Frailty represents a global problem, making early identification, evaluation, and treatment to prevent the cascade of events leading from functional decline to disability and death, one of the challenges of geriatric and general medicine. Cardiac arrhythmias are common in advancing age, chronic illness, and frailty and include a broad spectrum of rhythm and conduction abnormalities. However, no systematic studies or recommendations on the management of arrhythmias are available specifically for the elderly and frail population, and the uptake of many effective antiarrhythmic therapies in these patients remains the slowest. This European Heart Rhythm Association (EHRA) consensus document focuses on the biology of frailty, common comorbidities, and methods of assessing frailty, in respect to a specific issue of arrhythmias and conduction disease, provide evidence base advice on the management of arrhythmias in patients with frailty syndrome, and identifies knowledge gaps and directions for future research.


Asunto(s)
Fragilidad , Humanos , Anciano , Fragilidad/diagnóstico , Fragilidad/epidemiología , Fragilidad/terapia , Anciano Frágil , Consenso , América Latina , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/terapia , Trastorno del Sistema de Conducción Cardíaco
8.
Eur Heart J Suppl ; 25(Suppl G): G44-G55, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37970517

RESUMEN

Pacing from the right atrial appendage (RAA) prolongs the P wave duration and can induce interatrial and especially left-sided atrio-ventricular dyssynchrony. Pacing from Bachmann's bundle closely reproduces normal physiology and has the potential to avoid the electromechanical dysfunction associated with conventional RAA pacing. Interatrial conduction delay is associated with an increased risk of stroke, heart failure, and death. In addition to a reduction in atrial fibrillation, Bachmann's bundle pacing has emerging applications as a hemodynamic pacing modality. This review outlines the pathophysiology of atrial conduction disturbances and their potential remedies and provides the reader with a practical guide to implementing Bachmann's bundle pacing with an emphasis on the recapitulation of normal electrical and mechanical function.

9.
Heart Fail Rev ; 27(6): 2165-2176, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35670890

RESUMEN

Cardiac resynchronization therapy (CRT) may improve not only impaired left ventricular contractility but can also induce reverse remodeling of native conduction system. Measurement of intrinsic QRS complex width during follow-up is the simplest method to assess reverse electrical remodeling (RER). We aimed to provide a literature review and meta-analysis on incidence and impact of RER and its association with mechanical remodeling. A systematic review and random-effect meta-analysis of studies reporting data on RER was performed. A total of 16 studies were included in this meta-analysis with 930 patients undergoing CRT (mean age 64.0 years, 64.1% males). The weighted mean incidence of RER was 42%. Reverse mechanical remodeling assessed by echocardiography was more frequently observed in patients with RER compared to patients without RER (75.7% vs. 46.6%; odds ratio [OR] 3.7, 95% confidence interval [CI] 2.24-6.09, p < 0.01). Mechanical responders had a mean iQRS shortening of 7.7 ms, while mechanical non-responders experienced a mean widening of iQRS by 5.2 ms (p < 0.01). Clinical improvement was more frequent in patients with RER vs. patients without RER (82.9% vs. 49.0%; OR 5.26; 95% CI 2.92-9.48; p < 0.01). No significant difference in all-cause mortality between patients with and without RER was found. Mean difference between baseline intrinsic QRS and post-implantation paced QRS was significant in patients with later RER (21.2 ms, 95% CI 9.4-32.9, p < 0.01), but not in patients without RER (6.6 ms, 95% CI -2.2-15.4, p = 0.14). Gender, initial left bundle block morphology and heart failure etiology were found not to be predictive for RER. Our meta-analysis demonstrates that shortening of iQRS duration is a common finding during follow-up of patients undergoing CRT and is associated with mechanical reverse remodeling and clinical improvement. Clinical Trial Registration: Prospero Database-CRD42021253336.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Terapia de Resincronización Cardíaca/métodos , Electrocardiografía/métodos , Femenino , Sistema de Conducción Cardíaco , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Remodelación Ventricular
10.
Europace ; 24(7): 1058-1064, 2022 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-35061877

RESUMEN

AIMS: There is uncertainty about whether and how to perform screening for atrial fibrillation (AF). To estimate the incidence of previously undetected AF that would be captured using a continuous 14-day ECG monitor and the associated risk of stroke. METHODS AND RESULTS: We analysed data from a cohort of patients >65 years old with hypertension and a pacemaker, but without known AF. For each participant, we simulated 1000 ECG monitors by randomly selecting 14-day windows in the 6 months following enrolment and calculated the average AF burden (total time in AF). We used Cox proportional hazards models adjusted for CHA2DS2-VASc score to estimate the risk of subsequent ischaemic stroke or systemic embolism (SSE) associated with burdens of AF > and <6 min. Among 2470 participants, the median CHA2DS2-VASc score was 4.0, and 44 patients experienced SSE after 6 months following enrolment. The proportion of participants with an AF burden >6 min was 3.10% (95% CI 2.53-3.72). This was consistent across strata of age and CHA2DS2-VASc scores. Over a mean follow-up of 2.4 years, the rate of SSE among patients with <6 min of AF was 0.70%/year, compared to 2.18%/year (adjusted HR 3.02; 95% CI 1.39-6.56) in those with >6 min of AF. CONCLUSIONS: Approximately 3% of individuals aged >65 years with hypertension may have more than 6 min of AF detected by a 14-day ECG monitor. This is associated with a stroke risk of over 2% per year. Whether oral anticoagulation will reduce stroke in these patients is unknown.


Asunto(s)
Fibrilación Atrial , Isquemia Encefálica , Hipertensión , Accidente Cerebrovascular , Anciano , Anticoagulantes , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Isquemia Encefálica/diagnóstico , Electrocardiografía , Humanos , Hipertensión/diagnóstico , Hipertensión/epidemiología , Incidencia , Medición de Riesgo , Factores de Riesgo , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA