Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Europace ; 25(1): 40-48, 2023 02 08.
Artículo en Inglés | MEDLINE | ID: mdl-36037026

RESUMEN

AIMS: The recurrence rates after catheter ablation (CA) and direct current (DC) cardioversion remain high, although they have been established treatments of rhythm control of atrial fibrillation (AF). This umbrella review systematically appraises published meta-analyses of both observational and randomized controlled trials (RCTs) for the association of risk and protective factors for arrhythmia recurrence after CA and DC cardioversion of AF. METHODS AND RESULTS: Three bibliographic databases were searched up to June 2021. Evidence of association was rated as convincing, highly suggestive, suggestive, weak, or not significant with respect to observational studies and as high, moderate, low, or very low with respect to RCTs, according to established criteria. Thirty-one meta-analyses were included. Of the 28 associations between CA and the risk of arrhythmia recurrence, none presented convincing evidence, and only the time from diagnosis to ablation over 1 year provided highly suggestive evidence. The association between hypertension and metabolic profile provided suggestive evidence. The associations of Class IC and III antiarrhythmic drugs use with the recurrence after DC cardioversion were supported by an intermediate level of evidence. CONCLUSION: Although AF is a major health issue, few risk- and protective factors for AF recurrence have been identified. None of these factors examined were supported by convincing evidence, whereas established factors such as female gender and left atrial volume showed only weak association. An early CA strategy combined with treatment of metabolic syndrome and hypertension prior to CA may reduce the risk of arrhythmia recurrence. The use of antiarrhythmics can increase the success rate of DC cardioversion. SYSTEMATIC REVIEW REGISTRATION: PROSPERO registry number: CRD42021270613.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Femenino , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico , Cardioversión Eléctrica/efectos adversos , Recurrencia , Antiarrítmicos/uso terapéutico , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Resultado del Tratamiento
2.
Heart ; 110(3): 163-169, 2024 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-37657914

RESUMEN

OBJECTIVE: Catheter ablation of atrial fibrillation effectively reduces symptomatic burden. However, its long-term effect on mortality and stroke is unclear. We investigated if patients with atrial fibrillation who undergo catheter ablation have lower risk for all-cause mortality or stroke than patients who are managed medically. METHODS: We retrospectively included 5628 consecutive patients who underwent first-time catheter ablation for atrial fibrillation between 2008 and 2018 at three major Swedish electrophysiology units. Control individuals with an atrial fibrillation diagnosis but without previous stroke were selected from the Swedish National Patient Register, resulting in a control group of 48 676 patients. Propensity score matching was performed to produce two cohorts of equal size (n=3955) with similar baseline characteristics. The primary endpoint was a composite of all-cause mortality or stroke. RESULTS: Patients who underwent catheter ablation were healthier (mean CHA2DS2-VASc score 1.4±1.4 vs 1.6±1.5, p<0.001), had a higher median income (288 vs 212 1000 Swedish krona [KSEK]/year, p<0.001) and had more frequently received university education (45.1% vs 28.9%, p<0.001). Mean follow-up was 4.5±2.8 years. After propensity score matching, catheter ablation was associated with lower risk for the combined primary endpoint (HR 0.58, 95% CI 0.48 to 0.69). The result was mainly driven by a decrease in all-cause mortality (HR 0.51, 95% CI 0.41 to 0.63), with stroke reduction showing a trend in favour of catheter ablation (HR 0.75, 95% CI 0.53 to 1.07). CONCLUSIONS: Catheter ablation of atrial fibrillation was associated with a reduction in the primary endpoint of all-cause mortality or stroke. This result was driven by a marked reduction in all-cause mortality.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Accidente Cerebrovascular , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Factores de Riesgo , Medición de Riesgo/métodos , Estudios Retrospectivos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Resultado del Tratamiento
3.
J Atr Fibrillation ; 14(1): 20200454, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34950357

RESUMEN

BACKGROUND: Radiofrequency ablation (RFA)is an important treatment option for patients with atrial fibrillation (AF). During RFA, a significant amount of energy is delivered into the left atrium (LA), resulting in considerable LA-injury. The impact of this damage on mechanical and endocrine LA-function, however, is often disregarded.We therefore aimed to evaluate the endocrine- and mechanical function of the heart 4-months after RFA of AF. METHODS: In total 189 patients eligible for RFA of AF were studied. The levels of the N-terminal pro-B-natriuretic peptide (NT-proBNP) and the mid-regional fragment of the N-terminal pro-atrial natriuretic peptide (MR-proANP)were measured. The maximum LAvolume (LAVmax),the LAejection fraction (LAEF) and the LA peak longitudinal strain (PALS), were measured usingtransthoracic echocardiography. The measurements were performed before and 4-months after the intervention. RESULTS: 87 patients had a recurrence during a mean follow-up of 143±36 days.NT-proBNPand MR-proANPdecreased significantly at follow-up. This reduction was greater in patients who did not suffer any recurrence after RFA.The LAVmax decreased significantly, whereasthe PALS only improved in patients who did not suffer from any recurrence. On the other hand, LAEF did not change significantly after RFA of AF. CONCLUSIONS: Despite extensiveablation during RFA of AF, the endocrine function of the heart improved 4-months after the index procedure. Patients with no arrhythmia recurrence showed a more pronounced improvement in their endocrinal function. Mechanically, the LAVmax was reduced, and the LA strain improved significantly.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA