Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Opt Express ; 30(10): 17230-17242, 2022 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-36221550

RESUMEN

The flexible membranes used in MEMS tunable VCSELs are so small and light that thermally induced vibrations can impact laser performance. We measure the thermal vibration spectrum of such a membrane showing peaks at the spatial vibration mode resonant frequencies of the membrane/plate. These vibrations result in a theoretical floor to the linewidth of the VCSEL. Frequency domain LiDAR and optical coherence tomography systems can get around this thermal linewidth limit with adequate clock measurement and processing. Essentially an OCT/LiDAR sweep with a concomitantly measured clock is a feed-forward linewidth reduction scheme. This can be achieved because the membrane resonances are relatively low frequency. LiDAR ranging out to 9 meters has been demonstrated with a resolution of 13 µm, close to the transform limit for the 70 nm sampling range.

2.
Opt Express ; 22(10): 12255-72, 2014 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-24921344

RESUMEN

Multispectral fluorescence lifetime imaging (m-FLIM) can potentially allow identifying the endogenous fluorophores present in biological tissue. Quantitative description of such data requires estimating the number of components in the sample, their characteristic fluorescent decays, and their relative contributions or abundances. Unfortunately, this inverse problem usually requires prior knowledge about the data, which is seldom available in biomedical applications. This work presents a new methodology to estimate the number of potential endogenous fluorophores present in biological tissue samples from time-domain m-FLIM data. Furthermore, a completely blind linear unmixing algorithm is proposed. The method was validated using both synthetic and experimental m-FLIM data. The experimental m-FLIM data include in-vivo measurements from healthy and cancerous hamster cheek-pouch epithelial tissue, and ex-vivo measurements from human coronary atherosclerotic plaques. The analysis of m-FLIM data from in-vivo hamster oral mucosa identified healthy from precancerous lesions, based on the relative concentration of their characteristic fluorophores. The algorithm also provided a better description of atherosclerotic plaques in term of their endogenous fluorophores. These results demonstrate the potential of this methodology to provide quantitative description of tissue biochemical composition.


Asunto(s)
Algoritmos , Procesamiento de Imagen Asistido por Computador/métodos , Microscopía Fluorescente/métodos , Placa Aterosclerótica/patología , Animales , Cricetinae , Humanos , Análisis de Regresión
3.
Opt Lett ; 38(9): 1515-7, 2013 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-23632536

RESUMEN

Fluorescence lifetime imaging (FLIM) offers a noninvasive approach for characterizing the biochemical composition of biological tissue. There has been an increasing interest in the application of multispectral FLIM for medical diagnosis. Central to the clinical translation of FLIM technology is the development of compact and high-speed endoscopy systems. Unfortunately, the predominant multispectral FLIM approaches suffer from limitations that impede the development of endoscopy systems that are suitable for in vivo tissue imaging. We present a compact wide-field time-gated FLIM flexible endoscope capable of continuous lifetime imaging of up to three fluorescence emission bands simultaneously. This endoscope design will facilitate the evaluation of FLIM for in vivo applications.


Asunto(s)
Endoscopios , Imagen Molecular/instrumentación , Animales , Mejilla , Cricetinae , Espectrometría de Fluorescencia
4.
Photochem Photobiol ; 92(5): 694-701, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-27499123

RESUMEN

Successful early detection and demarcation of oral carcinoma can greatly impact the associated morbidity and mortality rates. Current methods for detection of oral cancer include comprehensive visual examination of the oral cavity, typically followed by tissue biopsy. A noninvasive means to guide the clinician in making a more objective and informed decision toward tissue biopsy can potentially improve the diagnostic yield of this process. To this end, we investigate the potential of fluorescence lifetime imaging (FLIM) for objective detection of oral carcinoma in the hamster cheek pouch model of oral carcinogenesis in vivo. We report that systematically selected FLIM features can differentiate between low-risk (normal, benign and low-grade dysplasia) and high-risk (high-grade dysplasia and cancer) oral lesions with sensitivity and specificity of 87.26% and 93.96%, respectively. We also show the ability of FLIM to generate "disease" maps of the tissue which can be used to evaluate relative risk of neoplasia. The results demonstrate the potential of multispectral FLIM with objective image analysis as a noninvasive tool to guide comprehensive oral examination.


Asunto(s)
Mejilla/diagnóstico por imagen , Neoplasias de la Boca/diagnóstico por imagen , Imagen Óptica , Animales , Mejilla/patología , Cricetinae , Humanos
5.
Oral Surg Oral Med Oral Pathol Oral Radiol ; 121(3): 290-300.e2, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26725720

RESUMEN

OBJECTIVES: Several imaging techniques have been advocated as clinical adjuncts to improve identification of suspicious oral lesions. However, these have not yet shown superior sensitivity or specificity over conventional oral examination techniques. We developed a multimodal, multi-scale optical imaging system that combines macroscopic biochemical imaging of fluorescence lifetime imaging with subcellular morphologic imaging of reflectance confocal microscopy for early detection of oral cancer. We tested our system on excised human oral tissues. STUDY DESIGN: In total, 4 tissue specimens were imaged. These specimens were diagnosed as either clinically normal, oral lichen planus, gingival hyperplasia, or superficially invasive squamous cell carcinoma. The optical and fluorescence lifetime properties of each specimen were recorded. RESULTS: Both quantitative and qualitative differences among normal, benign, and squamous cell carcinoma lesions can be resolved with fluorescence lifetime imaging reflectance confocal microscopy. The results demonstrate that an integrated approach based on these two methods can potentially enable rapid screening and evaluation of large areas of oral epithelial tissue. CONCLUSIONS: Early results from ongoing studies of imaging human oral cavity illustrate the synergistic combination of the 2 modalities. An adjunct device based on such optical characterization of oral mucosa can potentially be used to detect oral carcinogenesis in early stages.


Asunto(s)
Detección Precoz del Cáncer , Microscopía de Fluorescencia por Excitación Multifotónica , Neoplasias de la Boca/diagnóstico por imagen , Imagen Multimodal , Lesiones Precancerosas/diagnóstico por imagen , Diagnóstico Diferencial , Humanos
6.
PLoS One ; 10(3): e0122368, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25816131

RESUMEN

Automatic segmentation of nuclei in reflectance confocal microscopy images is critical for visualization and rapid quantification of nuclear-to-cytoplasmic ratio, a useful indicator of epithelial precancer. Reflectance confocal microscopy can provide three-dimensional imaging of epithelial tissue in vivo with sub-cellular resolution. Changes in nuclear density or nuclear-to-cytoplasmic ratio as a function of depth obtained from confocal images can be used to determine the presence or stage of epithelial cancers. However, low nuclear to background contrast, low resolution at greater imaging depths, and significant variation in reflectance signal of nuclei complicate segmentation required for quantification of nuclear-to-cytoplasmic ratio. Here, we present an automated segmentation method to segment nuclei in reflectance confocal images using a pulse coupled neural network algorithm, specifically a spiking cortical model, and an artificial neural network classifier. The segmentation algorithm was applied to an image model of nuclei with varying nuclear to background contrast. Greater than 90% of simulated nuclei were detected for contrast of 2.0 or greater. Confocal images of porcine and human oral mucosa were used to evaluate application to epithelial tissue. Segmentation accuracy was assessed using manual segmentation of nuclei as the gold standard.


Asunto(s)
Epitelio/ultraestructura , Mucosa Bucal/patología , Neoplasias/patología , Animales , Núcleo Celular/patología , Núcleo Celular/ultraestructura , Citoplasma/patología , Citoplasma/ultraestructura , Epitelio/patología , Humanos , Imagenología Tridimensional , Microscopía Confocal , Mucosa Bucal/ultraestructura , Porcinos
7.
Biomed Opt Express ; 5(3): 921-31, 2014 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-24688824

RESUMEN

There is an increasing interest in the application of fluorescence lifetime imaging (FLIM) for medical diagnosis. Central to the clinical translation of FLIM technology is the development of compact and high-speed clinically compatible systems. We present a handheld probe design consisting of a small maneuverable box fitted with a rigid endoscope, capable of continuous lifetime imaging at multiple emission bands simultaneously. The system was characterized using standard fluorescent dyes. The performance was then further demonstrated by imaging a hamster cheek pouch in vivo, and oral mucosa tissue both ex vivo and in vivo, all using safe and permissible exposure levels. Such a design can greatly facilitate the evaluation of FLIM for oral cancer imaging in vivo.

8.
Biomed Opt Express ; 5(2): 645-52, 2014 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-24575357

RESUMEN

This paper presents the use and characterization of an electrically focus tunable lens to perform axial scanning in a confocal microscope. Lateral and axial resolution are characterized over a >250 µm axial scan range. Confocal microscopy using optical axial scanning is demonstrated in epithelial tissue and compared to traditional stage scanning. By enabling rapid axial scanning, minimizing motion artifacts, and reducing mechanical complexity, this technique has potential to enhance in vivo three-dimensional imaging in confocal endomicroscopy.

9.
Biomed Opt Express ; 5(11): 3781-91, 2014 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-25426310

RESUMEN

This paper presents the design and evaluation of a reflectance confocal laser endomicroscope using a miniature objective lens within a rigid probe in conjunction with an electrically tunable lens for axial scanning. The miniature lens was characterized alone as well as in the endoscope across a 200 µm axial scan range using the tunable lens. The ability of the confocal endoscope to probe the human oral cavity is demonstrated by imaging of the oral mucosa in vivo. The results indicate that reflectance confocal endomicroscopy has the potential to be used in a clinical setting and guide diagnostic evaluation of biological tissue.

10.
Artículo en Inglés | MEDLINE | ID: mdl-29503493

RESUMEN

We present the use of a commercially available electrically tunable lens to achieve axial scanning in a reflectance confocal microscope. Over a 255 µm axial scan range, the lateral and axial resolutions varied from 1-2 µm and 4-14 µm, respectively, dependent on the variable focal length of the tunable lens. Confocal imaging was performed on normal human biopsies from the oral cavity ex vivo. Sub-cellular morphologic features were seen throughout the depth of the epithelium while axially scanning using the focus tunable lens.

11.
J Biomed Opt ; 18(4): 046012, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23595826

RESUMEN

Optical imaging techniques using a variety of contrast mechanisms are under evaluation for early detection of epithelial precancer; however, tradeoffs in field of view (FOV) and resolution may limit their application. Therefore, we present a multiscale multimodal optical imaging system combining macroscopic biochemical imaging of fluorescence lifetime imaging (FLIM) with subcellular morphologic imaging of reflectance confocal microscopy (RCM). The FLIM module images a 16×16 mm² tissue area with 62.5 µm lateral and 320 ps temporal resolution to guide cellular imaging of suspicious regions. Subsequently, coregistered RCM images are acquired at 7 Hz with 400 µm diameter FOV, <1 µm lateral and 3.5 µm axial resolution. FLIM-RCM imaging was performed on a tissue phantom, normal porcine buccal mucosa, and a hamster cheek pouch model of oral carcinogenesis. While FLIM is sensitive to biochemical and macroscopic architectural changes in tissue, RCM provides images of cell nuclear morphology, all key indicators of precancer progression.


Asunto(s)
Microscopía Confocal/métodos , Neoplasias de la Boca/diagnóstico , Imagen Óptica/métodos , Lesiones Precancerosas/diagnóstico , Animales , Mejilla/patología , Cricetinae , Diseño de Equipo , Microscopía Confocal/instrumentación , Mucosa Bucal/patología , Neoplasias de la Boca/patología , Imagen Óptica/instrumentación , Fantasmas de Imagen , Lesiones Precancerosas/patología , Porcinos
12.
Ann Biomed Eng ; 40(2): 378-97, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21994069

RESUMEN

Advances in fiber optic technology and miniaturized optics and mechanics have propelled confocal endomicroscopy into the clinical realm. This high resolution, non-invasive imaging technology provides the ability to microscopically evaluate cellular and sub-cellular features in tissue in vivo by optical sectioning. Because many cancers originate in epithelial tissues accessible by endoscopes, confocal endomicroscopy has been explored to detect regions of possible neoplasia at an earlier stage by imaging morphological features in vivo that are significant in histopathologic evaluation. This technique allows real-time assessment of tissue which may improve diagnostic yield by guiding biopsy. Research and development continues to reduce the overall size of the imaging probe, increase the image acquisition speed, and improve resolution and field of view of confocal endomicroscopes. Technical advances will continue to enable application to less accessible organs and more complex systems in the body. Lateral and axial resolutions down to 0.5 and 3 µm, respectively, field of view as large as 800 × 450 µm, and objective lens and total probe outer diameters down to 0.35 and 1.25 mm, respectively, have been achieved. We provide a review of the historical developments of confocal imaging in vivo, the evolution of endomicroscope instrumentation, and the medical applications of confocal endomicroscopy.


Asunto(s)
Endoscopios , Microscopía Confocal/instrumentación , Endoscopía/instrumentación , Endoscopía/métodos , Humanos , Microscopía Confocal/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA