Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Appl Opt ; 63(5): 1241-1246, 2024 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-38437303

RESUMEN

We demonstrate a Sagnac-interferometer-based multiwavelength fiber laser with an intensity-dependent loss (IDL) mechanism in the L-band region using a semiconductor optical amplifier (SOA) as the gain medium. The IDL mechanism flattens and stabilizes the multiwavelength spectrum. We also investigate the effect of rotation angles of polarization controllers (PCs) at different polarization devices on multiwavelength performance. At best settings, 31 lasing lines within 3 dB uniformity were generated with an extinction ratio (ER) of 17 dB. Adjusting the half-wave plate of PC1 and PC2 from 0° to 90° shifted the multiwavelength output by 0.01 nm and 0.072 nm, respectively. PC2 adjustment also affects the multiwavelength flatness as compared to PC1. Furthermore, the number of lasing lines and the ER were directly influenced by the SOA current.

2.
Sensors (Basel) ; 21(21)2021 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-34770602

RESUMEN

The color of transformer oil can be one of the first indicators determining the quality of the transformer oil and the condition of the power transformer. The current method of determining the color index (CI) of transformer oil utilizes a color comparator based on the American Society for Testing and Materials (ASTM) D1500 standard, which requires a human observer, leading to human error and a limited number of samples tested per day. This paper reports on the utilization of ultra violet-blue laser at 405- and 450-nm wavelengths to measure the CI of transformer oil. In total, 20 transformer oil samples with CI ranging from 0.5 to 7.5 were measured at optical pathlengths of 10 and 1 mm. A linear regression model was developed to determine the color index of the transformer oil. The equation was validated and verified by measuring the output power of a new batch of transformer oil samples. Data obtained from the measurements were able to quantify the CI accurately with root-mean-square errors (RMSEs) of 0.2229 for 405 nm and 0.4129 for 450 nm. This approach shows the commercialization potential of a low-cost portable device that can be used on-site for the monitoring of power transformers.


Asunto(s)
Suministros de Energía Eléctrica , Rayos Láser , Humanos
3.
Sensors (Basel) ; 21(20)2021 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-34696079

RESUMEN

For most natural or naturally-derived liquid products, their color reflects on their quality and occasionally affects customer preferences. To date, there are a few subjective and objective methods for color measurement which are currently utilized by various industries. Researchers are also improving these methods and inventing new methods, as color is proven to have the ability to provide various information on the condition and quality of the liquid. However, a review on the methods, especially for amber-colored liquid, has not been conducted yet. This paper presents a comprehensive review on the subjective and objective methods for color measurement of amber-colored liquids. The pros and cons of the measurement methods, the effects of the color on customer preferences, and the international industry standards on color measurements are reviewed and discussed. In addition, this study elaborates on the issues and challenges related to the color measurement techniques as well as recommendations for future research. This review demonstrates that the existing color measurement technique can determine the color according to the standards and color scales. However, the efforts toward minimizing the complexity of the hardware while maximizing the signal processing through advanced computation are still lacking. Therefore, through this critical review, this review can hopefully intensify the efforts toward finding an optimized method or technique for color measurement of liquids and thus expedite the development of a portable device that can measure color accurately.


Asunto(s)
Estándares de Referencia , Color , Predicción
4.
Heliyon ; 9(10): e20585, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37842600

RESUMEN

Accurate spectral irradiance measurement in the near-infrared range is significant for the design and characterization of photodetector and photovoltaic cells. Approximation method is commonly used to solve for the input power using estimated spectral irradiance, where the dependency on wavelength and temperature remains uncertain. This study aims to determine the power spectrum at different radiation temperatures using a single pixel photodetector, taking into consideration factors such as transmission spectra of alumina radiator, CaF2 collimating lens, responsivity, and measured photocurrent information of photodetectors. Utilizing predictive mathematical model, five commercial photodetectors, including Silicon, Germanium, In0.53Ga0.47As, In0.73Ga0.27As, and In0.83Ga0.17As were used to solve for the power densities as a function of wavelengths at radiation temperatures of 1000 °C and 1500 °C. The spectral irradiance of photodetectors was determined with a percentage difference of <4.9 %, presenting an accurate power density estimation for the spectrum at a wide range of radiation temperatures. Power irradiance data obtained were validated in the narrow wavelength range with 1000 nm, 1400 nm, 1500 nm, and 2000 nm bandpass filters. The reported work demonstrates a simple and efficient way which could contribute to develop a cost-effective method of measuring and determining the spectrum irradiances of objects at different radiation temperatures. This predictive analysis method hopefully intensifies the progress of efforts to reduce the reliance on complex optoelectronic instruments in accurately solving power irradiance information.

5.
Materials (Basel) ; 14(17)2021 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-34501032

RESUMEN

Generally, waste heat is redundantly released into the surrounding by anthropogenic activities without strategized planning. Consequently, urban heat islands and global warming chronically increases over time. Thermophotovoltaic (TPV) systems can be potentially deployed to harvest waste heat and recuperate energy to tackle this global issue with supplementary generation of electrical energy. This paper presents a critical review on two dominant types of semiconductor materials, namely gallium antimonide (GaSb) and indium gallium arsenide (InGaAs), as the potential candidates for TPV cells. The advantages and drawbacks of non-epitaxy and epitaxy growth methods are well-discussed based on different semiconductor materials. In addition, this paper critically examines and summarizes the electrical cell performance of TPV cells made of GaSb, InGaAs and other narrow bandgap semiconductor materials. The cell conversion efficiency improvement in terms of structural design and architectural optimization are also comprehensively analyzed and discussed. Lastly, the practical applications, current issues and challenges of TPV cells are critically reviewed and concluded with recommendations for future research. The highlighted insights of this review will contribute to the increase in effort towards development of future TPV systems with improved cell conversion efficiency.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA