Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Hum Mol Genet ; 31(13): 2262-2278, 2022 07 07.
Artículo en Inglés | MEDLINE | ID: mdl-35137071

RESUMEN

Recessive mutations in the CTNS gene encoding the lysosomal transporter cystinosin cause cystinosis, a lysosomal storage disease leading to kidney failure and multisystem manifestations. A Ctns knockout mouse model recapitulates features of cystinosis, but the delayed onset of kidney manifestations, phenotype variability and strain effects limit its use for mechanistic and drug development studies. To provide a better model for cystinosis, we generated a Ctns knockout rat model using CRISPR/Cas9 technology. The Ctns-/- rats display progressive cystine accumulation and crystal formation in multiple tissues including kidney, liver and thyroid. They show an early onset and progressive loss of urinary solutes, indicating generalized proximal tubule dysfunction, with development of typical swan-neck lesions, tubulointerstitial fibrosis and kidney failure, and decreased survival. The Ctns-/- rats also present crystals in the cornea, and bone and liver defects, as observed in patients. Mechanistically, the loss of cystinosin induces a phenotype switch associating abnormal proliferation and dedifferentiation, loss of apical receptors and transporters, and defective lysosomal activity and autophagy in the cells. Primary cultures of proximal tubule cells derived from the Ctns-/- rat kidneys confirmed the key changes caused by cystine overload, including reduced endocytic uptake, increased proliferation and defective lysosomal dynamics and autophagy. The novel Ctns-/- rat model and derived proximal tubule cell system provide invaluable tools to investigate the pathogenesis of cystinosis and to accelerate drug discovery.


Asunto(s)
Sistemas de Transporte de Aminoácidos Neutros , Cistinosis , Síndrome de Fanconi , Insuficiencia Renal , Sistemas de Transporte de Aminoácidos Neutros/genética , Animales , Autofagia/genética , Cistina , Cistinosis/genética , Cistinosis/patología , Lisosomas/metabolismo , Ratones , Ratas
2.
Hum Mol Genet ; 29(1): 132-148, 2020 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-31696227

RESUMEN

Optic nerve hypoplasia (ONH) is a congenital optic nerve abnormality caused by underdevelopment of retinal ganglion cells (RGCs). Despite being a rare disease, ONH is the most common optic disk anomaly in ophthalmological practice. So far, mutations in several genes have been identified as causative; however, many cases of ONH remain without a molecular explanation. The early transcription factor atonal basic-helix-loop-helix (bHLH) transcription factor 7 (ATOH7) is expressed in retinal progenitor cells and has a crucial role in RGC development. Previous studies have identified several mutations in the ATOH7 locus in cases of eye developmental diseases such as non-syndromic congenital retinal non-attachment and persistent hyperplasia of the primary vitreous. Here we present two siblings with a phenotype predominated by bilateral ONH, with additional features of foveal hypoplasia and distinct vascular abnormalities, where whole-exome sequencing identified two compound heterozygous missense mutations affecting a conserved amino acid residue within the bHLH domain of ATOH7 (NM_145178.3:c.175G>A; p.(Ala59Thr) and c.176C>T; p.(Ala59Val)). ATOH7 expression constructs with patient single nucleotide variants were cloned for functional characterization. Protein analyses revealed decreased protein amounts and significantly enhanced degradation in the presence of E47, a putative bHLH dimerization partner. Protein interaction assays revealed decreased heterodimerization and DNA-binding of ATOH7 variants, resulting in total loss of transcriptional activation of luciferase reporter gene expression. These findings strongly support pathogenicity of the two ATOH7 mutations, one of which is novel. Additionally, this report highlights the possible impact of altered ATOH7 dimerization on protein stability and function.


Asunto(s)
Factores de Transcripción con Motivo Hélice-Asa-Hélice Básico/metabolismo , Enfermedades del Nervio Óptico/congénito , Hipoplasia del Nervio Óptico/metabolismo , Hipoplasia del Nervio Óptico/patología , Adolescente , Factores de Transcripción con Motivo Hélice-Asa-Hélice Básico/genética , Niño , Femenino , Pruebas Genéticas , Humanos , Masculino , Persona de Mediana Edad , Mutación/genética , Mutación Missense/genética , Enfermedades del Nervio Óptico/genética , Enfermedades del Nervio Óptico/metabolismo , Enfermedades del Nervio Óptico/patología , Hipoplasia del Nervio Óptico/genética , Linaje , Células Ganglionares de la Retina/metabolismo
3.
Doc Ophthalmol ; 145(3): 175-184, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36199003

RESUMEN

PURPOSE: To develop and validate a flicker electroretinogram (ERG) protocol in term-born neonates as a potential tool for assessing preterm infants at risk of developing retinopathy of prematurity. METHODS: A custom flicker ERG protocol was developed for use with the hand-held RETeval® electrophysiology device. Feasibility of measuring flicker ERG through closed eyelids and without mydriasis was established in a pilot study enabling optimisation of the test protocol. Following this, healthy term-born neonates (gestational age 37-42 weeks) were recruited at the Neonatology clinic of the University Hospital Zurich. Flicker ERG recordings were performed using proprietary disposable skin electrodes during the first four days of life when the infants were sleeping. Flicker stimuli were presented at 28.3 Hz for a stimulus series at 3, 6, 12, 30, and 50 cd·s/m2, with two measurements at each stimulus level. Results were analysed offline. Flicker ERG peak times and amplitudes were derived from the averaged measurements per stimulus level for each subject. RESULTS: 28 term-born neonates were included in the analysis. All infants tolerated the testing procedure well. Flicker ERG recording was achieved in all subjects with reproducible flicker ERG waveforms for 30 and 50 cd·s/m2 stimuli. Reproducible ERGs were recorded in the majority of infants for the weaker stimuli (with detectable ERGs in 20/28, 25/28, and 27/28 at 3, 6, and 12 cd·s/m2, respectively). Flicker ERG amplitudes increased with increasing stimulus strength, with peak times concurrently decreasing slightly. CONCLUSION: Flicker ERG recording is feasible and reliably recorded in sleeping neonates through closed eyelids using skin electrodes and without mydriasis. Flicker ERG amplitude decreases for lower luminance flicker but remains detectable for 3 cd·s/m2 flicker in the majority of healthy term-born neonates. These data provide a basis to study retinal function in premature infants using this protocol.


Asunto(s)
Electrorretinografía , Midriasis , Recién Nacido , Lactante , Humanos , Electrorretinografía/métodos , Proyectos Piloto , Estimulación Luminosa/métodos , Recien Nacido Prematuro , Retina
4.
Doc Ophthalmol ; 144(1): 3-16, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34705132

RESUMEN

BACKGROUND: Researchers have in recent years begun to investigate ophthalmological manifestations of multiple sclerosis (MS) other than optic neuritis (ON), and it is now clear that changes to retinal function (measured using the electroretinogram, ERG) and structure (measured using optical coherence tomography, OCT) are found in MS patients irrespective of prior ON episodes. ERG results are consistent with dysfunctional bipolar cells, as in other autoimmune diseases. To date, studies have presented only cross-sectional data regarding ERG and OCT. We, therefore, studied the longitudinal course of ERG and OCT in patients with MS, as well as the effect of disability changes and non-ON clinical relapses on these functional and structural measures. METHODS: MS patients (n = 23) participating in an ongoing longitudinal observational study were invited to take part in a 3-year ophthalmological substudy. ERG and OCT were performed, and measures of MS-related disability and relapse history were obtained. Study visits were repeated annually. ERG peak times, rod b-wave amplitude, mixed rod/cone and cone b-/a-wave amplitude ratios, thickness of the peripapillary retinal nerve fibre layer, and volumes of the segmented retinal layers/complexes were analysed. Using generalised estimating equation models adjusted for age, ON, and MS treatment status, we assessed changes to ERG and OCT over the study duration, the effect of changes in disability and recent non-ON MS relapses on ERG and OCT, and the effect of selected OCT parameters on corresponding ERG parameters. RESULTS: At the group level, small fluctuations of several ERG peak times were recorded, with OCT values remaining stable. Increased disability between visits was associated with significant prolongation of mixed rod-cone ERG b-wave peak times. No evidence of associations between OCT and ERG parameters was observed. CONCLUSIONS: Retinal bipolar cell function may be affected by changes in disability in patients with MS; however, recent non-ON MS clinical relapses appear not to affect ERG or OCT results. As ERG changes in MS patients over 3 years are likely to be small and of uncertain clinical relevance, longitudinal studies of retinal function in MS should be planned over an extended period.


Asunto(s)
Esclerosis Múltiple , Neuritis Óptica , Estudios Transversales , Electrorretinografía , Humanos , Estudios Longitudinales , Esclerosis Múltiple/complicaciones , Esclerosis Múltiple/diagnóstico , Recurrencia , Tomografía de Coherencia Óptica/métodos
5.
Int J Mol Sci ; 22(4)2021 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-33546218

RESUMEN

The purpose of this study was to develop a flexible, cost-efficient, next-generation sequencing (NGS) protocol for genetic testing. Long-range polymerase chain reaction (PCR) amplicons of up to 20 kb in size were designed to amplify entire genomic regions for a panel (n = 35) of inherited retinal disease (IRD)-associated loci. Amplicons were pooled and sequenced by NGS. The analysis was applied to 227 probands diagnosed with IRD: (A) 108 previously molecularly diagnosed, (B) 94 without previous genetic testing, and (C) 25 undiagnosed after whole-exome sequencing (WES). The method was validated with 100% sensitivity on cohort A. Long-range PCR-based sequencing revealed likely causative variant(s) in 51% and 24% of proband from cohorts B and C, respectively. Breakpoints of 3 copy number variants (CNVs) could be characterized. Long-range PCR libraries spike-in extended coverage of WES. Read phasing confirmed compound heterozygosity in 5 probands. The proposed sequencing protocol provided deep coverage of the entire gene, including intronic and promoter regions. Our method can be used (i) as a first-tier assay to reduce genetic testing costs, (ii) to elucidate missing heritability cases, (iii) to characterize breakpoints of CNVs at nucleotide resolution, (iv) to extend WES data to non-coding regions by spiking-in long-range PCR libraries, and (v) to help with phasing of candidate variants.


Asunto(s)
Transportadoras de Casetes de Unión a ATP/genética , Bestrofinas/genética , Secuenciación de Nucleótidos de Alto Rendimiento , Periferinas/genética , Enfermedades de la Retina/genética , Análisis de Secuencia de ADN , Adolescente , Adulto , Anciano , Niño , Preescolar , Canales Catiónicos Regulados por Nucleótidos Cíclicos/genética , Variaciones en el Número de Copia de ADN , Proteínas del Ojo/genética , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Proteínas de la Membrana/genética , Proteínas Asociadas a Microtúbulos/genética , Persona de Mediana Edad , Mutación , Proteínas del Tejido Nervioso/genética , Reacción en Cadena de la Polimerasa , Enfermedades de la Retina/congénito , Enfermedades de la Retina/diagnóstico , Adulto Joven
6.
J Neuroophthalmol ; 39(1): 3-7, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30015656

RESUMEN

BACKGROUND: Recurrent optic neuritis (rON) associated with myelin oligodendrocyte glycoprotein (MOG)-specific antibodies has been initially reported to show a better clinical outcome than aquaporin-4 (AQP4)-seropositive ON in neuromyelitis optica spectrum disorder (NMOSD). Here, we characterize clinical and neuroimaging findings in severe cases of MOG antibody-positive and AQP4 antibody-negative bilateral rON. METHODS: Three male adults with rON (ages 18, 44, and 63 years) were evaluated with optical coherence tomography (OCT), MRI, cerebrospinal fluid (CSF), and serological studies. RESULTS: All patients experienced >7 relapses of ON with severe reduction of visual acuity and partial response to steroid treatment. Optic nerves were affected bilaterally, although unilateral relapses were more frequent than simultaneous bilateral recurrences. Patients were MOG-seropositive but repeatedly tested negative for AQP4 antibodies. OCT showed severe thinning of the peripapillary retinal nerve fiber layer. On MRI, contrast-enhancing lesions extended over more than half the length of the optic nerve. CSF analyses during ON episodes were normal. Severe visual deficits accumulated over time in 2 of 3 patients, despite immunosuppressive therapy. CONCLUSIONS: MOG-seropositive and AQP4-seronegative rON may be associated with an aggressive disease course and poor functional and structural outcomes. In contrast to previous reports, the severity and pattern of retinal and optic nerve damage closely resembled phenotypes commonly observed in AQP4-seropositive rON without fulfilling current diagnostic criteria for NMOSD.


Asunto(s)
Autoanticuerpos/inmunología , Glicoproteína Mielina-Oligodendrócito/inmunología , Nervio Óptico/patología , Neuritis Óptica/diagnóstico , Agudeza Visual , Adolescente , Anciano , Acuaporina 4/inmunología , Humanos , Masculino , Persona de Mediana Edad , Nervio Óptico/fisiopatología , Neuritis Óptica/inmunología , Neuritis Óptica/fisiopatología , Pronóstico , Recurrencia , Tomografía de Coherencia Óptica
7.
Curr Opin Neurol ; 31(5): 662-668, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30074495

RESUMEN

PURPOSE OF REVIEW: Optical coherence tomography (OCT) is a noninvasive in-vivo imaging tool that enables the quantification of the various retinal layer thicknesses. Given the frequent involvement of the visual pathway in multiple sclerosis, OCT has become an important tool in clinical practice, research and clinical trials. In this review, the role of OCT as a means to investigate visual pathway damage in multiple sclerosis is discussed. RECENT FINDINGS: Evidence from recent OCT studies suggests that the peripapillary retinal nerve fibre layer (pRNFL) appears to be an ideal marker of axonal integrity, whereas the macular ganglion cell and inner plexiform layer (GCIP) thickness enables early detection of neuronal degeneration in multiple sclerosis. The thickness of the macular inner nuclear layer (INL) has been suggested as a biomarker for inflammatory disease activity and treatment response in multiple sclerosis. OCT parameters may also be used as an outcome measure in clinical trials evaluating the neuroprotective or regenerative potential of new treatments. SUMMARY: OCT provides insights into multiple sclerosis beyond the visual pathway. It is capable of quantifying the major pathological hallmarks of the disease, specifically inflammation and neuroaxonal degeneration. OCT, therefore, has the potential to become another mainstay in the monitoring of multiple sclerosis patients.


Asunto(s)
Esclerosis Múltiple/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos , Humanos , Vías Visuales/diagnóstico por imagen
8.
J Neuroophthalmol ; 38(2): 172-178, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29210928

RESUMEN

BACKGROUND: To investigate and quantify the impact of intracranial lesions at different locations within the visual pathway on the ganglion cell layer-inner plexiform layer (GCL-IPL) complex and the retinal nerve fiber layer (RNFL). METHODS: Patients with intracranial lesions affecting the optic chiasm (Group I) or the optic tract and/or lateral geniculate nucleus (Group II) were included. All patients received kinetic visual field assessment and underwent spectral domain optical coherence tomography. Peripapillary and papillomacular bundle (PMB) RNFL and macular GCL-IPL thickness in 4 perifoveal areas were measured and compared with normal values derived from 52 age-matched healthy control subjects. Z-scores for each parameter of every patient were calculated and compared with the normative data. Z-scores less than -2.0 (e.g., -2.5) were considered as being statistically significant. RESULTS: Twenty-two patients (Group I and II: 13 and 9, respectively) were included. Ten of 13 patients in Group I showed significant binasal GCL-IPL thinning, with associated temporal sector thinning in 8 patients. In Group II, all 9 patients showed significant reduction of the GCL-IPL corresponding to the homonymous visual field defect, but only 4 demonstrated RNFL thinning. Contralateral RNFL thinning within the PMB clinically similar to bow-tie atrophy was evident in all patients in Group II. GCL-IPL and RNFL thinning varied in severity from mild (isolated PMB RNFL thickness reduction) to severe (bilateral asymmetrical reduction of PMB RNFL associated with asymmetric, predominantly nasal reduction of GCL-IPL) in Group I. CONCLUSION: Clinical abnormalities in patients with visual pathway lesions are more likely to demonstrate abnormalities of GCL-IPL than global peripapillary RNFL thickness. However, PMB thickness measurement appears to be a valuable tool to detect abnormalities of the anterior visual pathways. If peripapillary RNFL measurements are performed in such patients, PMB thickness should be considered the most useful quantitative parameter.


Asunto(s)
Cuerpos Geniculados/patología , Fibras Nerviosas/patología , Quiasma Óptico/patología , Enfermedades del Nervio Óptico/diagnóstico , Tracto Óptico/patología , Células Ganglionares de la Retina/patología , Vías Visuales/patología , Adulto , Femenino , Cuerpos Geniculados/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Quiasma Óptico/diagnóstico por imagen , Tracto Óptico/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos , Trastornos de la Visión/diagnóstico , Agudeza Visual , Campos Visuales , Vías Visuales/diagnóstico por imagen , Adulto Joven
9.
Mol Psychiatry ; 21(7): 936-45, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-26370147

RESUMEN

Autism spectrum disorder (ASD) is a common neurodevelopmental condition characterized by marked genetic heterogeneity. Recent studies of rare structural and sequence variants have identified hundreds of loci involved in ASD, but our knowledge of the overall genetic architecture and the underlying pathophysiological mechanisms remains incomplete. Glycine receptors (GlyRs) are ligand-gated chloride channels that mediate inhibitory neurotransmission in the adult nervous system but exert an excitatory action in immature neurons. GlyRs containing the α2 subunit are highly expressed in the embryonic brain, where they promote cortical interneuron migration and the generation of excitatory projection neurons. We previously identified a rare microdeletion of the X-linked gene GLRA2, encoding the GlyR α2 subunit, in a boy with autism. The microdeletion removes the terminal exons of the gene (GLRA2(Δex8-9)). Here, we sequenced 400 males with ASD and identified one de novo missense mutation, p.R153Q, absent from controls. In vitro functional analysis demonstrated that the GLRA2(Δex8)(-)(9) protein failed to localize to the cell membrane, while the R153Q mutation impaired surface expression and markedly reduced sensitivity to glycine. Very recently, an additional de novo missense mutation (p.N136S) was reported in a boy with ASD, and we show that this mutation also reduced cell-surface expression and glycine sensitivity. Targeted glra2 knockdown in zebrafish induced severe axon-branching defects, rescued by injection of wild type but not GLRA2(Δex8-9) or R153Q transcripts, providing further evidence for their loss-of-function effect. Glra2 knockout mice exhibited deficits in object recognition memory and impaired long-term potentiation in the prefrontal cortex. Taken together, these results implicate GLRA2 in non-syndromic ASD, unveil a novel role for GLRA2 in synaptic plasticity and learning and memory, and link altered glycinergic signaling to social and cognitive impairments.


Asunto(s)
Glicina/metabolismo , Receptores de Glicina/genética , Receptores de Glicina/metabolismo , Adolescente , Adulto , Animales , Trastorno del Espectro Autista/metabolismo , Trastorno Autístico/metabolismo , Niño , Preescolar , Glicina/genética , Humanos , Potenciación a Largo Plazo/efectos de los fármacos , Masculino , Ratones , Ratones Endogámicos C57BL , Neurogénesis/efectos de los fármacos , Plasticidad Neuronal/efectos de los fármacos , Neuronas/metabolismo , Transducción de Señal/efectos de los fármacos , Transmisión Sináptica/fisiología , Pez Cebra
10.
Semin Neurol ; 36(2): 177-84, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27116724

RESUMEN

Retinal optical coherence tomography (OCT) has recently become a vital tool for clinicians and researchers in ophthalmology and, increasingly, in neurology. Optical coherence tomography is quickly and easily performed, well-tolerated by patients, and allows high-resolution viewing of unmyelinated axons and other retinal structures in vivo. These factors have led OCT to find favor as a method of quantifying neuroaxonal loss in multiple sclerosis (MS), and the increasing acceptance of the anterior visual pathway as a model to investigate MS in humans.In this short review, the authors discuss OCT findings in MS research, and the relationships of these structural findings with established functional outcome measures such as visual acuity and electrophysiological examinations. The utility of OCT in patients with acute optic neuritis is emphasized. Optical coherence tomography is a particularly powerful tool when the individual retinal layers are visualized and quantified following the segmentation of scans; this technique shows promise as a method for defining novel MS phenotypes.


Asunto(s)
Esclerosis Múltiple/diagnóstico por imagen , Neuritis Óptica/diagnóstico , Tomografía de Coherencia Óptica , Humanos , Esclerosis Múltiple/complicaciones , Neuritis Óptica/etiología , Retina , Células Ganglionares de la Retina
11.
Doc Ophthalmol ; 132(2): 147-55, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26921203

RESUMEN

PURPOSE: Laser pointer devices have become increasingly available in recent years, and their misuse has caused a number of ocular injuries. Online distribution channels permit trade in devices which may not conform to international standards in terms of their output power and spectral content. We present a case study of ocular injury caused by one such device. METHODS: The patient was examined approximately 9 months following laser exposure using full-field and multifocal electroretinography (ERG and MF-ERG), electrooculography (EOG), and optical coherence tomography (OCT), in addition to a full ophthalmological examination. MF-ERG, OCT, and the ophthalmological examination were repeated 7 months after the first examination. The output of the laser pointer was measured. RESULTS: Despite severe focal damage to the central retina visible fundoscopically and with OCT, all electrophysiological examinations were quantitatively normal; however, qualitatively the central responses of the MF-ERG appeared slightly reduced. When the MF-ERG was repeated 7 months later, all findings were normal. The laser pointer was found to emit both visible and infrared radiation in dangerous amounts. CONCLUSION: Loss of retinal function following laser pointer injury may not always be detectable using standard electrophysiological tests. Exposure to non-visible radiation should be considered as a possible aggravating factor when assessing cases of alleged laser pointer injury.


Asunto(s)
Rayos Infrarrojos/efectos adversos , Rayos Láser/efectos adversos , Luz/efectos adversos , Retina/efectos de la radiación , Enfermedades de la Retina/diagnóstico , Niño , Electrooculografía , Electrorretinografía/métodos , Femenino , Humanos , Retina/fisiopatología , Enfermedades de la Retina/etiología , Enfermedades de la Retina/fisiopatología , Estudios Retrospectivos , Tomografía de Coherencia Óptica , Agudeza Visual
12.
Int J Mol Sci ; 17(11)2016 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-27854301

RESUMEN

Irreversible disability in multiple sclerosis (MS) and neuromyelitis optica spectrum disorder (NMOSD) is largely attributed to neuronal and axonal degeneration, which, along with inflammation, is one of the major pathological hallmarks of these diseases. Optical coherence tomography (OCT) is a non-invasive imaging tool that has been used in MS, NMOSD, and other diseases to quantify damage to the retina, including the ganglion cells and their axons. The fact that these are the only unmyelinated axons within the central nervous system (CNS) renders the afferent visual pathway an ideal model for studying axonal and neuronal degeneration in neurodegenerative diseases. Structural magnetic resonance imaging (MRI) can be used to obtain anatomical information about the CNS and to quantify evolving pathology in MS and NMOSD, both globally and in specific regions of the visual pathway including the optic nerve, optic radiations and visual cortex. Therefore, correlations between brain or optic nerve abnormalities on MRI, and retinal pathology using OCT, may shed light on how damage to one part of the CNS can affect others. In addition, these imaging techniques can help identify important differences between MS and NMOSD such as disease-specific damage to the visual pathway, trans-synaptic degeneration, or pathological changes independent of the underlying disease process. This review focuses on the current knowledge of the role of the visual pathway using OCT and MRI in patients with MS and NMOSD. Emphasis is placed on studies that employ both MRI and OCT to investigate damage to the visual system in these diseases.


Asunto(s)
Esclerosis Múltiple/diagnóstico por imagen , Neuromielitis Óptica/diagnóstico por imagen , Nervio Óptico/diagnóstico por imagen , Células Ganglionares de la Retina/patología , Corteza Visual/diagnóstico por imagen , Axones/patología , Axones/ultraestructura , Humanos , Imagen por Resonancia Magnética , Esclerosis Múltiple/patología , Esclerosis Múltiple/fisiopatología , Fibras Nerviosas/patología , Neuromielitis Óptica/patología , Neuromielitis Óptica/fisiopatología , Nervio Óptico/patología , Nervio Óptico/fisiopatología , Sinapsis/patología , Sinapsis/ultraestructura , Tomografía de Coherencia Óptica , Corteza Visual/patología , Corteza Visual/fisiopatología
13.
Eur J Paediatr Neurol ; 48: 113-120, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38217965

RESUMEN

BACKGROUND: Myelin oligodendrocyte glycoprotein antibody-associated disease (MOGAD) comprises various age-dependent clinical phenotypes and may be monophasic, multiphasic, or chronic. Optic neuritis (ON) is a common manifestation and frequently appears in combination with other MOGAD phenotypes, particularly in young children. Despite permanent structural damage to the retinal nerve fiber layer (RNFL), children often experience complete visual recovery. AIMS: To analyze the progression and impact of MOGAD on the visual system of pediatric patients independently of the history of ON. METHODS: This retrospective study included children who met specific criteria: myelin oligodendrocyte glycoprotein (MOG) immunoglobulin G (IgG) seropositivity, acute presentation of MOGAD, and written general consent. Main outcome measures were global peripapillary retinal nerve fiber layer (pRNFL) thickness, and near and distance visual acuity, analyzed using descriptive statistics. RESULTS: We identified 10 patients with median age of 7.7 years at first event: 7 patients manifested with acute disseminated encephalomyelitis (ADEM) (with ON 5/7, ADEM only 1/7, with transverse myelitis (TM) 1/7), 2 with isolated ON, and 1 patient with neuromyelitis optica spectrum disorder (NMOSD)-like phenotype with ON. Among ON patients, 5/8 were affected bilaterally, with 3 initially diagnosed with unilateral ON but experiencing subsequent involvement of the fellow eye. None of the patients without previous ON showed a deterioration of visual acuity and, if evaluated, a reduction of the pRNFL. CONCLUSION: Most pediatric MOGAD-ON patients in our cohort presented with acute vison loss and optic disc edema. All patients achieved complete visual recovery, independent of number of relapses or initial visual loss. The pRNFL thickness decreased for several months and stabilized at reduced levels after 12 months in the absence of further relapses. MOGAD may not have subclinical/'silent' effects on the visual system, as visual acuity and pRNFL were not affected in patients without ON.


Asunto(s)
Encefalomielitis Aguda Diseminada , Neuromielitis Óptica , Neuritis Óptica , Humanos , Niño , Preescolar , Glicoproteína Mielina-Oligodendrócito , Estudios Retrospectivos , Autoanticuerpos , Recurrencia Local de Neoplasia , Evaluación de Resultado en la Atención de Salud , Recurrencia
14.
Eye (Lond) ; 2024 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-38783086

RESUMEN

BACKGROUND: Infants born prematurely are at risk of developing retinopathy of prematurity, which is associated with abnormalities in retinal function as measured using electroretinography. The aim of this study was to record non-invasive flicker electroretinograms (ERGs) in preterm infants and compare function of moderate and very or extremely preterm infants. METHODS: In this non-randomized, cross-sectional study, 40 moderate preterm (gestational age (GA) 34 0/7 to 36 6/7 weeks, Group A) and 40 very or extremely preterm infants (GA ≤ 31 weeks, Group B) were recruited for flicker ERG recording through closed eyelids using the RETeval® device and skin electrodes. Group A was tested within the first week of life and Group B between 34th and 37th week postmenstrual age. Flicker stimuli were presented at 28.3 Hz with stimulus levels of 3, 6, 12, 30 and 50 cd•s/m2. Primary endpoints were peak time (ms) and amplitude (µV). RESULTS: Flicker ERGs were recordable in most infants with the highest proportion of reproducible ERGs at 30 cd•s/m2. Amplitudes increased with stronger flicker stimulation, while peak times did not differ significantly between stimulus levels nor groups. Amplitudes were significantly greater in Group B at the strongest stimulus level (Mann-Whitney-U-Test=198.00, Z = 4.097, p = <0.001). CONCLUSIONS: Feasibility of collecting flicker ERG data in most preterm infants was confirmed. We found no evidence of reduced retinal responses to flicker stimuli associated with extreme prematurity. Higher amplitudes in very and extremely preterm infants could indicate acceleration of retinal development following birth, triggered by visual stimulation.

15.
Am J Ophthalmol ; 2024 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-38880371

RESUMEN

PURPOSE: To study the long-term effects of perinatal high-dose recombinant human erythropoietin (rhEPO) on macular structural and vascular development in preterm children. DESIGN: Randomized, double-blind clinical trial follow-up plus cohort study. METHODS: Setting: Department of Ophthalmology, University Hospital Zurich, Zurich, Switzerland. STUDY POPULATION: extremely or very preterm born children aged 7-15 years from an ongoing neuropediatric study (EpoKids). These had been previously randomized to receive either high-dose rhEPO or placebo perinatally. INCLUSION CRITERIA: participation in the EpoKids Study, written informed consent (IC). EXCLUSION CRITERIA: previous ocular trauma or surgery; retinal or developmental disease unrelated to prematurity. Term-born children of comparable age were enrolled as a healthy control (HC) group. INCLUSION CRITERIA: term birth, IC. EXCLUSION CRITERIA: any ocular or visual abnormality, high refractive error. Examiners were blinded regarding intervention status until completion of all analyses. (Participants/guardians remain blinded). OBSERVATION PROCEDURES: Spectral-domain OCT scans (Heidelberg Spectralis system) and OCTA imaging (Zeiss PlexElite 9000) were obtained. Ophthalmological and orthoptic examinations excluded ocular comorbidities. MAIN OUTCOME MEASURES: OCT (central retinal thickness, CRT; total macular volume, TMV), superficial plexus OCTA (foveal avascular zone, FAZ; vessel density, VD; vessel length density, VLD) parameters and foveal hypoplasia grade according to published criteria. RESULTS: Macular vessel density parameters (VD and VLD) were significantly lower (p =0.015, CI-95: 0.01 to 0.06 and p=0.015, CI-95: 0.74 to 3.64) in the EPO group (n= 52) when compared to placebo (n=35). No other significant differences were observed between the EPO and placebo group. When comparing the intervention subgroups to HC we found six significant differences in OCT and OCTA parameters (FAZ, VD, VLD and CRT comparing HC and EPO group; FAZ and CRT when comparing HC and placebo group). CONCLUSIONS: Early high-dose rhEPO in infants born extremely or very preterm affects macular vessel density parameters compared to placebo. Premature birth (regardless of intervention status) affects retinal structure and vascular development. Our findings on macular vascular development do not contraindicate the administration of early high-dose EPO in preterm infants. For further understanding of the role of EPO on macular development and its clinical significance, future studies are needed.

16.
BMC Ophthalmol ; 13: 44, 2013 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-24006952

RESUMEN

BACKGROUND: Icare PRO (ICP) is a new Rebound tonometer that is able to measure intraocular pressure (IOP) in both sitting and reclining positions. In this study, the gold standard Goldmann tonometer (GAT) was compared to ICP and Tono-Pen AVIA (TPA). Hypothesis was that repeatability of GAT is superior to ICP and TPA. METHODS: 36 eyes of 36 healthy caucasian individuals, 13 male and 26 females, 17 right and 19 left eyes have been included in this prospective, randomized, cross-sectional study. The study was conducted at a single site (Dept. of Ophthalmology, University Hospital Zurich, Switzerland). Primary outcome measures were Intraclass correlation coefficients (ICC) and coefficients of variation (COV) and test-retest repeatability as visualized by Bland-Altman analysis. Secondary outcome measures were IOP in sitting (GAT, ICP and TPA) and in reclining (ICP and TPA) position. RESULTS: Mean IOP measured by GAT was 14.9 ± 3.5 mmHg. Mean IOP measured by ICP was 15.6 ± 3.1 mmHg (with TPA 14.8 ± 2.7 mmHg) in sitting and 16.5 ± 3.5 mmHg (with TPA 17.0 ± 3.0 mmHg) in reclining positions. COVs ranged from 2.9% (GAT) to 6.9% (ICP reclining) and ICCs from 0.819 (ICP reclining) to 0.972 (GAT). CONCLUSIONS: Repeatability is good with all three devices. GAT has higher repeatability compared to the two tested hand-held devices with lowest COVs and highest ICCs. IOP was higher in the reclining compared to the sitting position. TRIAL REGISTRATION: The study was registered to the Clinical Trials Register of the US National Institute of Health, NCT01325324.


Asunto(s)
Glaucoma/diagnóstico , Presión Intraocular/fisiología , Posicionamiento del Paciente/métodos , Tonometría Ocular/instrumentación , Adulto , Estudios Transversales , Femenino , Glaucoma/fisiopatología , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Tonometría Ocular/normas
17.
Artículo en Inglés | MEDLINE | ID: mdl-36857194

RESUMEN

PURPOSE: Hydroxychloroquine (HCQ) can cause irreversible damage to the retina, especially when taken over longer periods. The American Academy of Ophthalmology recommends a regimen for dosing, screening and monitoring of patients treated with HCQ. We present an unusual case of a rapid development of severe HCQ-associated-retinopathy already after 2 years after commencing HCQ treatment. METHODS: Observational case report. Clinical examination, optical coherence tomography (OCT), fundus autofluorescence imaging (FAF), perimetry, full-field & multifocal electroretinography (ERG) were performed. Ancillary tests included neoplastic and paraneoplastic work-up, vitamin levels and whole exome sequencing, in order to rule out other potential causes of a panretinal degeneration. RESULTS: We report on a 58-year-old woman with rheumatoid arthritis, treated initially with 200mg HCQ daily for 1 year (daily dose 3.6mg/kg), then 400mg daily for 1 year (daily dose 7.2mg/kg), and a cumulative dose of 216 g. Her medical history was otherwise unremarkable. No family history for inherited retinal conditions. She was referred due to a rapid and sudden progressive and severe concentric visual field constriction, two years after commencing HCQ treatment. CONCLUSION: This case of a rapid-onset, severe panretinal degeneration shortly after start of HCQ treatment suggests underlying mechanisms and risk factors for HCQ toxicity in addition to those previously reported, and a potential need for supplementary screening tests to prevent HCQ toxicity. AAO dosing guidelines of 5 MG/KG should be strictly adhered to in patients receiving HCQ therapy.

18.
Acta Ophthalmol ; 101(2): 200-206, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36073938

RESUMEN

PURPOSE: Hyperreflective foci are poorly understood transient elements seen on optical coherence tomography (OCT) of the retina in both healthy and diseased eyes. Systematic studies may benefit from the development of automated tools that can map and track such foci. The outer nuclear layer (ONL) of the retina is an attractive layer in which to study hyperreflective foci as it has no fixed hyperreflective elements in healthy eyes. In this study, we intended to evaluate whether automated image analysis can identify, quantify and visualize hyperreflective foci in the ONL of the retina. METHODS: This longitudinal exploratory study investigated 14 eyes of seven patients including six patients with optic neuropathy and one with mild non-proliferative diabetic retinopathy. In total, 2596 OCT B-scan were obtained. An image analysis blob detector algorithm was used to detect candidate foci, and a convolutional neural network (CNN) trained on a manually labelled subset of data was then used to select those candidate foci in the ONL that fitted the characteristics of the reference foci best. RESULTS: In the manually labelled data set, the blob detector found 2548 candidate foci, correctly detecting 350 (89%) out of 391 manually labelled reference foci. The accuracy of CNN classifier was assessed by manually splitting the 2548 candidate foci into a training and validation set. On the validation set, the classifier obtained an accuracy of 96.3%, a sensitivity of 88.4% and a specificity of 97.5% (AUC 0.989). CONCLUSION: This study demonstrated that automated image analysis and machine learning methods can be used to successfully identify, quantify and visualize hyperreflective foci in the ONL of the retina on OCT scans.


Asunto(s)
Retinopatía Diabética , Retina , Humanos , Estudios Retrospectivos , Retina/diagnóstico por imagen , Retinopatía Diabética/diagnóstico , Tomografía de Coherencia Óptica/métodos
19.
Biomedicines ; 11(6)2023 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-37371724

RESUMEN

PURPOSE: To evaluate the impact of drusen-like deposits (DLD) on retinal layer integrity and retinal function by optical coherence tomography (OCT) and multifocal electroretinography (mfERG) in patients with systemic lupus erythematosus (SLE). METHODS: We identified 66 eyes of 33 SLE patients treated with hydroxychloroquine (HCQ) that were categorized into two groups according to whether DLDs were present (34 eyes, Group One) or absent (32 eyes, Group Two). The groups were matched for age, sex, HCQ treatment duration, daily, and cumulative dosage. OCT (retinal layer thicknesses, central retinal thickness, CRT) and mfERG concentric ring analysis were analyzed and compared. RESULTS: CRT was significantly thicker in Group One compared to Group Two (273.21 ± 3.96 vs. 254.5 ± 7.62) (p = 0.023). Group One also demonstrated an overall thicker retinal pigment epithelium compared to Group Two; however, the other outer retinal layers, outer nuclear layer, and photoreceptor layer were found to be significantly thinner in Group One compared to Group Two. We found no differences in mfERG parameters between the two groups. CONCLUSIONS: DLDs in SLE patients lead to abnormal central retinal layer thickness, which has no measurable impact on cone-mediated retinal function assessed by mfERG.

20.
Swiss Med Wkly ; 153: 40097, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37921090

RESUMEN

AIMS OF THE STUDY: Vitamin A deficiency retinopathy is a potentially blinding disease. In developed countries, vitamin A deficiency due to malnutrition is rare. However, vitamin A deficiency can be caused by malabsorption resulting from bowel resection or medication. In this retrospective study, we present five cases of vitamin A deficiency retinopathy related to malabsorption secondary to medical interventions. METHODS: Electronic charts over a ten-year period (2012-2022) were screened for vitamin A deficiency retinopathy. Only patients with vitamin A deficiency confirmed by laboratory tests were included. Symptoms, medical history, visual acuity, optical coherence tomography, fundus autofluorescence, electrophysiological examination, and vitamin A levels were reviewed. RESULTS: Five eligible cases were identified. Median age was 44.7 years (range 22.2-88.9), median duration of ocular symptoms prior to diagnosis was 14 months, and median visual acuity was 1.0 (range 0.5-1.0, Snellen, decimal). Three patients had a history of bariatric surgery, one patient had a small bowel resection and was on octreotide treatment, and one patient suffered from cystic fibrosis and had a history of small bowel resection and severe hepatopathy. Optical coherence tomography showed various abnormalities, including a reduced interdigitation zone, subretinal drusenoid deposits, and a thinned outer nuclear layer. Electroretinogram findings ranged from abnormal oscillatory potentials to non-recordable rod responses. CONCLUSIONS: Vitamin A deficiency retinopathy can occur following medical interventions associated with malabsorption. In cases of night blindness, vitamin A levels should be measured.


Asunto(s)
Enfermedades de la Retina , Deficiencia de Vitamina A , Adulto , Anciano , Anciano de 80 o más Años , Humanos , Persona de Mediana Edad , Adulto Joven , Enfermedades de la Retina/complicaciones , Estudios Retrospectivos , Suiza , Vitamina A , Deficiencia de Vitamina A/complicaciones , Deficiencia de Vitamina A/diagnóstico , Deficiencia de Vitamina A/tratamiento farmacológico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA