Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Cytometry A ; 99(1): 107-116, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33090656

RESUMEN

Results from the first gating proficiency panel of intracellular cytokine staining (ICS) highlighted the value of using a consensus gating approach to reduce the variability across laboratories in reported %CD8+ or %CD4+ cytokine-positive cells. Based on the data analysis from the first proficiency panel, harmonization guidelines for a consensus gating protocol were proposed. To validate the recommendations from the first panel and to examine factors that were not included in the first panel, a second ICS gating proficiency panel was organized. All participants analyzed the same set of Flow Cytometry Standard (FCS) files using their own gating protocol. An optional learning module was provided to demonstrate how to apply the previously established gating recommendations and harmonization guidelines to actual ICS data files. Eighty-three participants took part in this proficiency panel. The results from this proficiency panel confirmed the harmonization guidelines from the first panel. These recommendations addressed the (1) placement of the cytokine-positive gate, (2) identification of CD4+ CD8+ double-positive T cells, (3) placement of lymphocyte gate, (4) inclusion of dim cells, (5) gate uniformity, and (6) proper adjustment of the biexponential scaling. In addition, based on the results of this proficiency gating panel, two new recommendations were added to expand the harmonization guidelines: (1) inclusion of dump channel marker to gate all live and dump negative cells and (2) backgating to confirm the correct placement of gates across all populations. © 2020 International Society for Advancement of Cytometry.


Asunto(s)
Citocinas , Neoplasias , Citometría de Flujo , Humanos , Inmunoterapia , Neoplasias/terapia , Reproducibilidad de los Resultados , Coloración y Etiquetado
2.
Immunity ; 31(4): 527-8, 2009 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-19833080

RESUMEN

Immunotherapy, especially therapeutic vaccination, has a great deal of potential in the treatment of cancer and certain infectious diseases such as HIV (Allison et al., 2006; Fauci et al., 2008; Feldmann and Steinman, 2005). Numerous vaccine candidates have been tested in patients with a variety of tumor types and chronic viral diseases. Often, the best way to assess the clinical potential of these vaccines is to monitor the induced T cell response, and yet there are currently no standards for reporting these results. This letter is an effort to address this problem.


Asunto(s)
Vacunas contra el Cáncer/uso terapéutico , Inmunoensayo/normas , Monitorización Inmunológica/normas , Neoplasias/terapia , Guías de Práctica Clínica como Asunto/normas , Linfocitos T/inmunología , Vacunas Virales/uso terapéutico , Virosis/terapia , Vacunas contra el Cáncer/inmunología , Humanos , Inmunoterapia , Vacunas Virales/inmunología
3.
Methods Mol Biol ; 2768: 1-13, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38502384

RESUMEN

The ELISpot assay has a solid place in the immune monitoring field for over 40 years. It is an assay that can assess the function of single immune cells in a straightforward and easy-to-learn approach. Its use in basic research, translational, and clinical work has been documented in countless publications. Harmonization guidelines and invaluable tools for optimal assay performance and evaluation exist. However, the validation of an established ELISpot protocol has been left to diverse opinions about how to interpret and tackle typical validation parameters. This chapter addresses important considerations for ELISpot validation, including the interpretations of validation parameters for a meaningful description of assay performance.


Asunto(s)
Interferón gamma , Ensayo de Immunospot Ligado a Enzimas/métodos
4.
Methods Mol Biol ; 2768: 305-316, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38502401

RESUMEN

Interferon-gamma (IFNγ) ELISpot and FluoroSpot are widely used assays to detect functional cell responses in immunotherapy clinical studies. Recognized for their importance in vaccine development studies to quantitate immune responses, these assays have more recently risen to the forefront in cell and gene therapy as well as cancer immunotherapy fields where responses against cancer neoantigens are not easily detectable above assay background. Here, we test a new class of fetal bovine serum (FBS), CultraPure FBS, in ex vivo ELISpot and FluoroSpot assays and cultured FluoroSpot assays following in vitro expansion. Several CultraPure FBS lots that have been specially formulated through the process of lyophilization (lyo-FBS) were compared to liquid CultraPure FBS. We stimulated human PBMCs with antigen-specific peptide pools diluted in media supplemented with liquid CultraPure FBS or lyo-FBS and found equivalent cytokine production with negligible to no assay background with both liquid and lyo-FBS formats. Moreover, the lyo-FBS showed lot-to-lot consistency and 90-day refrigerated (4 °C) stability in both ex vivo direct and in vitro cultured assays. In addition, we present here a method using lyo-FBS for the expansion of low-frequency antigen-specific T cells, mimicking the low frequency seen with cancer neoantigens by utilizing a cultured FluoroSpot assay. Our results demonstrate the presence of Granzyme B, interferon-gamma (IFNγ), and tumor necrosis factor (TNF) production by antigen-specific polyfunctional T cells following a 9-day culture using media supplemented with lyo-FBS.


Asunto(s)
Neoplasias , Vacunas , Humanos , Albúmina Sérica Bovina , Interferón gamma , Inmunidad
5.
Cancer Immunol Immunother ; 62(4): 615-27, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23138872

RESUMEN

Robust and sensitive ELISPOT protocols are commonly applied concomitant with the development of new immunotherapeutics. Despite the knowledge that individual serum batches differ in their composition and may change properties over time, serum is still commonly used in immunologic assays. Commercially available serum batches are expensive, limited in quantity and need to be pretested for suitability in immunologic assays, which is a laborious process. The aim of this study was to test whether serum-free freezing media can lead to high cell viability and favorable performance across multiple ELISPOT assay protocols. Thirty-one laboratories from ten countries participated in a proficiency panel organized by the Cancer Immunotherapy Immunoguiding Program to test the influence of different freezing media on cell quality and immunologic function. Each center received peripheral blood mononuclear cells which were frozen in three different media. The participants were asked to quantify antigen-specific CD8+ T-cell responses against model antigens using their locally established IFN-gamma ELISPOT protocols. Self-made and commercially available serum-free freezing media led to higher cell viability and similar cell recovery after thawing and resting compared to freezing media supplemented with human serum. Furthermore, the test performance as determined by (1) background spot production, (2) replicate variation, (3) frequency of detected antigen-specific spots and (4) response detection rate was similar for serum and serum-free conditions. We conclude that defined and accessible serum-free freezing media should be recommended for freezing cells stored for subsequent ELISPOT analysis.


Asunto(s)
Medio de Cultivo Libre de Suero/química , Ensayo de Immunospot Ligado a Enzimas/métodos , Leucocitos Mononucleares/química , Animales , Bovinos , Supervivencia Celular , Ensayo de Immunospot Ligado a Enzimas/normas , Epítopos de Linfocito T/análisis , Epítopos de Linfocito T/inmunología , Congelación , Antígeno HLA-A2/química , Antígeno HLA-A2/inmunología , Humanos , Interferón gamma/química , Interferón gamma/inmunología , Leucocitos Mononucleares/inmunología , Fragmentos de Péptidos/química , Fragmentos de Péptidos/inmunología , Linfocitos T/química , Linfocitos T/inmunología
6.
Cytometry A ; 83(8): 728-38, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23788464

RESUMEN

Previous results from two proficiency panels of intracellular cytokine staining (ICS) from the Cancer Immunotherapy Consortium and panels from the National Institute of Allergy and Infectious Disease and the Association for Cancer Immunotherapy highlight the variability across laboratories in reported % CD8+ or % CD4+ cytokine-positive cells. One of the main causes of interassay variability in flow cytometry-based assays is due to differences in gating strategies between laboratories, which may prohibit the generation of robust results within single centers and across institutions. To study how gating strategies affect the variation in reported results, a gating panel was organized where all participants analyzed the same set of Flow Cytometry Standard (FCS) files from a four-color ICS assay using their own gating protocol (Phase I) and a gating protocol drafted by consensus from the organizers of the panel (Phase II). Focusing on analysis removed donor, assay, and instrument variation, enabling us to quantify the variability caused by gating alone. One hundred ten participating laboratories applied 110 different gating approaches. This led to high variability in the reported percentage of cytokine-positive cells and consequently in response detection in Phase I. However, variability was dramatically reduced when all laboratories used the same gating strategy (Phase II). Proximity of the cytokine gate to the negative population most impacted true-positive and false-positive response detection. Recommendations are provided for the (1) placement of the cytokine-positive gate, (2) identification of CD4+ CD8+ double-positive T cells, (3) placement of lymphocyte gate, (4) inclusion of dim cells, (5) gate uniformity, and 6) proper adjustment of the biexponential scaling.


Asunto(s)
Citocinas/metabolismo , Citometría de Flujo/normas , Neoplasias/terapia , Linfocitos T CD4-Positivos/metabolismo , Linfocitos T CD8-positivos/metabolismo , Citometría de Flujo/métodos , Humanos , Inmunoterapia , Cooperación Internacional , Laboratorios/normas , Ensayos de Aptitud de Laboratorios , Neoplasias/inmunología , Neoplasias/patología , Reproducibilidad de los Resultados , Coloración y Etiquetado
7.
J Immunol Methods ; 515: 113452, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36858170

RESUMEN

The use of conventional serum for supplementation of media in cell-based and single-cell functional assays has been a major challenge for assay performance, standardization, optimization, and reproducibility. It has been identified as the leading cause of variability and suboptimal performance in large, international Elispot proficiency panels (Janetzki et al., 2008; Rountree et al., 2016). Extensive pretesting and optimization activities are one approach to overcome these challenges, but they are time-consuming and resource-intensive because suitable lots of serum are difficult to identify and secure in sufficient quantities to provide stability in long-term studies. Advancements in manufacturing methods have resulted in a new class of serum with the potential to solve these challenges. An IFNÉ£ Elispot study was designed by the External Quality Assurance Program Oversight Laboratory (EQAPOL) at Duke Human Vaccine Institute's (DHVI) Immunology and Virology Quality Assessment Center (IVQAC) to test this new class of serum against their in-house, validated control serum, which is regarded as a global standard in performance for high functionality, recovery, and viability. Commonly used serum-free media were also included in the study. The results of this study compellingly demonstrate that this new class of serum produces high responses and low background reactivity comparable to the included serum standard, with excellent recovery and viability of cells. A protocol for ongoing testing has been developed to continuously validate new batches of this serum with the goal to make available to the field a pretested and validated serum that can be used with confidence in functional cell-based assays.


Asunto(s)
Laboratorios , Humanos , Reproducibilidad de los Resultados , Ensayo de Immunospot Ligado a Enzimas , Estándares de Referencia
8.
AAPS J ; 25(3): 47, 2023 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-37101079

RESUMEN

The number of approved or investigational late phase viral vector gene therapies (GTx) has been rapidly growing. The adeno-associated virus vector (AAV) technology continues to be the most used GTx platform of choice. The presence of pre-existing anti-AAV immunity has been firmly established and is broadly viewed as a potential deterrent for successful AAV transduction with a possibility of negative impact on clinical efficacy and a connection to adverse events. Recommendations for the evaluation of humoral, including neutralizing and total antibody based, anti-AAV immune response have been presented elsewhere. This manuscript aims to cover considerations related to the assessment of anti-AAV cellular immune response, including review of correlations between humoral and cellular responses, potential value of cellular immunogenicity assessment, and commonly used analytical methodologies and parameters critical for monitoring assay performance. This manuscript was authored by a group of scientists involved in GTx development who represent several pharma and contract research organizations. It is our intent to provide recommendations and guidance to the industry sponsors, academic laboratories, and regulatory agencies working on AAV-based GTx viral vector modalities with the goal of achieving a more consistent approach to anti-AAV cellular immune response assessment.


Asunto(s)
Dependovirus , Terapia Genética , Dependovirus/genética , Terapia Genética/métodos , Inmunidad Celular , Vectores Genéticos
9.
J Transl Med ; 9: 108, 2011 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-21745365

RESUMEN

BACKGROUND: The introduction of antibody markers to identify undesired cell populations in flow-cytometry based assays, so called DUMP channel markers, has become a practice in an increasing number of labs performing HLA-peptide multimer assays. However, the impact of the introduction of a DUMP channel in multimer assays has so far not been systematically investigated across a broad variety of protocols. METHODS: The Cancer Research Institute's Cancer Immunotherapy Consortium (CRI-CIC) conducted a multimer proficiency panel with a specific focus on the impact of DUMP channel use. The panel design allowed individual laboratories to use their own protocol for thawing, staining, gating, and data analysis. Each experiment was performed twice and in parallel, with and without the application of a dump channel strategy. RESULTS: The introduction of a DUMP channel is an effective measure to reduce the amount of non-specific MULTIMER binding to T cells. Beneficial effects for the use of a DUMP channel were observed across a wide range of individual laboratories and for all tested donor-antigen combinations. In 48% of experiments we observed a reduction of the background MULTIMER-binding. In this subgroup of experiments the median background reduction observed after introduction of a DUMP channel was 0.053%. CONCLUSIONS: We conclude that appropriate use of a DUMP channel can significantly reduce background staining across a large fraction of protocols and improve the ability to accurately detect and quantify the frequency of antigen-specific T cells by multimer reagents. Thus, use of a DUMP channel may become crucial for detecting low frequency antigen-specific immune responses. Further recommendations on assay performance and data presentation guidelines for publication of MULTIMER experimental data are provided.


Asunto(s)
Biomarcadores/metabolismo , Antígenos HLA/metabolismo , Péptidos/metabolismo , Multimerización de Proteína , Coloración y Etiquetado/métodos , Linfocitos T CD8-positivos/citología , Linfocitos T CD8-positivos/inmunología , Supervivencia Celular , Colorantes/metabolismo , Biología Computacional , Humanos , Recuento de Linfocitos , Unión Proteica , Reproducibilidad de los Resultados , Fracciones Subcelulares/metabolismo
10.
J Transl Med ; 9: 214, 2011 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-22168571

RESUMEN

Scientific discoveries that provide strong evidence of antitumor effects in preclinical models often encounter significant delays before being tested in patients with cancer. While some of these delays have a scientific basis, others do not. We need to do better. Innovative strategies need to move into early stage clinical trials as quickly as it is safe, and if successful, these therapies should efficiently obtain regulatory approval and widespread clinical application. In late 2009 and 2010 the Society for Immunotherapy of Cancer (SITC), convened an "Immunotherapy Summit" with representatives from immunotherapy organizations representing Europe, Japan, China and North America to discuss collaborations to improve development and delivery of cancer immunotherapy. One of the concepts raised by SITC and defined as critical by all parties was the need to identify hurdles that impede effective translation of cancer immunotherapy. With consensus on these hurdles, international working groups could be developed to make recommendations vetted by the participating organizations. These recommendations could then be considered by regulatory bodies, governmental and private funding agencies, pharmaceutical companies and academic institutions to facilitate changes necessary to accelerate clinical translation of novel immune-based cancer therapies. The critical hurdles identified by representatives of the collaborating organizations, now organized as the World Immunotherapy Council, are presented and discussed in this report. Some of the identified hurdles impede all investigators; others hinder investigators only in certain regions or institutions or are more relevant to specific types of immunotherapy or first-in-humans studies. Each of these hurdles can significantly delay clinical translation of promising advances in immunotherapy yet if overcome, have the potential to improve outcomes of patients with cancer.


Asunto(s)
Inmunoterapia , Neoplasias/terapia , Humanos , Cooperación Internacional , Investigación Biomédica Traslacional
11.
Mol Ther Methods Clin Dev ; 22: 183-195, 2021 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-34485604

RESUMEN

Adeno-associated virus (AAV)-based gene therapies have recently shown promise as a novel treatment for hereditary diseases. Due to the viral origin of the vector capsid, however, cellular immune response may be elicited that could eliminate transduced target cells. To monitor cellular immune responses in clinical trials, we optimized and bioanalytically validated a sensitive, robust, and reliable interferon-γ (IFN-γ) enzyme-linked immunospot (ELISpot) assay. For method performance validation, human peripheral blood mononuclear cells (PBMCs) were stimulated with peptides derived from AAV5 capsid proteins and the encoded transgene product, human blood clotting factor VIII (FVIII), in addition to positive controls, such as peptides from the 65-kDa phosphoprotein of cytomegalovirus. We statistically assessed the limit of detection and confirmatory cutpoint, evaluated precision and linearity, and confirmed specificity using HIV peptides. Robustness parameter ranges and sample stability periods were established. The validated IFN-γ ELISpot assay was then implemented in an AAV5-FVIII gene therapy clinical trial. Cellular immune responses against the AAV5 capsid were observed in most participants as soon as 2 weeks following dose administration; only limited responses against the transgene product were detected. These data underscore the value of using validated methods for monitoring cellular immunity in AAV gene therapy trials.

12.
Cancer Immunol Immunother ; 59(4): 609-18, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19894047

RESUMEN

The choice of serum for supplementation of media for T cell assays and in particular, Elispot has been a major challenge for assay performance, standardization, optimization, and reproducibility. The Assay Working Group of the Cancer Vaccine Consortium (CVC-CRI) has recently identified the choice of serum to be the leading cause for variability and suboptimal performance in large international Elispot proficiency panels. Therefore, a serum task force was initiated to compare the performance of commercially available serum-free media to laboratories' own medium/serum combinations. The objective of this project was to investigate whether a serum-free medium exists that performs as well as lab-own serum/media combinations with regard to antigen-specific responses and background reactivity in Elispot. In this way, a straightforward solution could be provided to address the serum challenge. Eleven laboratories tested peripheral blood mononuclear cells (PBMC) from four donors for their reactivity against two peptide pools, following their own Standard Operating Procedure (SOP). Each laboratory performed five simultaneous experiments with the same SOP, the only difference between the experiments was the medium used. The five media were lab-own serum-supplemented medium, AIM-V, CTL, Optmizer, and X-Vivo. The serum task force results demonstrate compellingly that serum-free media perform as well as qualified medium/serum combinations, independent of the applied SOP. Recovery and viability of cells are largely unaffected by serum-free conditions even after overnight resting. Furthermore, one serum-free medium was identified that appears to enhance antigen-specific IFNgamma-secretion.


Asunto(s)
Técnicas de Laboratorio Clínico/normas , Medio de Cultivo Libre de Suero/farmacología , Ensayo de Inmunoadsorción Enzimática/métodos , Inmunoensayo/métodos , Interferón gamma/inmunología , Leucocitos Mononucleares/inmunología , Linfocitos T/inmunología , Técnicas de Laboratorio Clínico/estadística & datos numéricos , Humanos , Inmunoensayo/normas , Estándares de Referencia
13.
Front Immunol ; 11: 576756, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33488576

RESUMEN

Background and Aims: Photochemical internalization (PCI) is a technology for inducing release of endocytosed antigens into the cell cytosol via a light-induced process. Preclinical experiments have shown that PCI improves MHC class I antigen presentation, resulting in strongly enhanced CD8+ T-cell responses to polypeptide antigens. In PCI vaccination a mixture of the photosensitizing compound fimaporfin, vaccine antigens, and an adjuvant is administered intradermally followed by illumination of the vaccination site. This work describes an open label, phase I study in healthy volunteers, to assess the safety, tolerability, and immune response to PCI vaccination in combination with the adjuvant poly-ICLC (Hiltonol) (ClinicalTrials.gov Identifier: NCT02947854). Methods: The primary objective of the study was to assess the safety and local tolerance of PCI mediated vaccination, and to identify a safe fimaporfin dose for later clinical studies. A secondary objective was to analyze the immunological responses to the vaccination. Each subject received 3 doses of HPV16 E7 peptide antigens and two doses of Keyhole Limpet Hemocyanin (KLH) protein. A control group received Hiltonol and vaccine antigens only, whereas the PCI groups in addition received fimaporfin + light. Local and systemic adverse effects were assessed by standard criteria, and cellular and humoral immune responses were analyzed by ELISpot, flow cytometry, and ELISA assays. Results: 96 healthy volunteers were vaccinated with fimaporfin doses of 0.75-50 µg. Doses below 17.5 µg were safe and tolerable, higher doses exhibited local tolerability issues in some study subjects, mainly erythema, and pain during illumination. There were few, and only mild and expected systemic adverse events. The employment of PCI increased the number of subjects exhibiting a T-cell response to the HPV peptide vaccine about 10-fold over what was achieved with the antigen/Hiltonol combination without PCI. Moreover, the use of PCI seemed to result in a more consistent and multifunctional CD8+ T-cell response. An enhancement of the humoral immune response to KLH vaccination was also observed. Conclusions: Using PCI in combination with Hiltonol for intradermal vaccination is safe at fimaporfin doses below 17.5 µg, and gives encouraging immune responses to peptide and protein based vaccination.


Asunto(s)
Papillomavirus Humano 16/fisiología , Proteínas E7 de Papillomavirus/inmunología , Infecciones por Papillomavirus/inmunología , Vacunas contra Papillomavirus/inmunología , Péptidos/inmunología , Fármacos Fotosensibilizantes/inmunología , Linfocitos T/inmunología , Vacunación/métodos , Adulto , Células Cultivadas , Femenino , Voluntarios Sanos , Humanos , Inmunidad Celular , Iluminación , Masculino , Persona de Mediana Edad , Procesos Fotoquímicos , Vacunas de Subunidad , Adulto Joven
14.
J Immunother Cancer ; 8(2)2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33268350

RESUMEN

Since the publication of the Society for Immunotherapy of Cancer's (SITC) original cancer immunotherapy biomarkers resource document, there have been remarkable breakthroughs in cancer immunotherapy, in particular the development and approval of immune checkpoint inhibitors, engineered cellular therapies, and tumor vaccines to unleash antitumor immune activity. The most notable feature of these breakthroughs is the achievement of durable clinical responses in some patients, enabling long-term survival. These durable responses have been noted in tumor types that were not previously considered immunotherapy-sensitive, suggesting that all patients with cancer may have the potential to benefit from immunotherapy. However, a persistent challenge in the field is the fact that only a minority of patients respond to immunotherapy, especially those therapies that rely on endogenous immune activation such as checkpoint inhibitors and vaccination due to the complex and heterogeneous immune escape mechanisms which can develop in each patient. Therefore, the development of robust biomarkers for each immunotherapy strategy, enabling rational patient selection and the design of precise combination therapies, is key for the continued success and improvement of immunotherapy. In this document, we summarize and update established biomarkers, guidelines, and regulatory considerations for clinical immune biomarker development, discuss well-known and novel technologies for biomarker discovery and validation, and provide tools and resources that can be used by the biomarker research community to facilitate the continued development of immuno-oncology and aid in the goal of durable responses in all patients.


Asunto(s)
Biomarcadores de Tumor/inmunología , Inmunoterapia/métodos , Neoplasias/inmunología , Neoplasias/terapia , Humanos
15.
Cancer Immunol Immunother ; 58(10): 1701-13, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19259668

RESUMEN

PURPOSE: The Cancer Vaccine Consortium of the Cancer Research Institute (CVC-CRI) conducted a multicenter HLA-peptide multimer proficiency panel (MPP) with a group of 27 laboratories to assess the performance of the assay. EXPERIMENTAL DESIGN: Participants used commercially available HLA-peptide multimers and a well characterized common source of peripheral blood mononuclear cells (PBMC). The frequency of CD8+ T cells specific for two HLA-A2-restricted model antigens was measured by flow cytometry. The panel design allowed for participants to use their preferred staining reagents and locally established protocols for both cell labeling, data acquisition and analysis. RESULTS: We observed significant differences in both the performance characteristics of the assay and the reported frequencies of specific T cells across laboratories. These results emphasize the need to identify the critical variables important for the observed variability to allow for harmonization of the technique across institutions. CONCLUSIONS: Three key recommendations emerged that would likely reduce assay variability and thus move toward harmonizing of this assay. (1) Use of more than two colors for the staining (2) collect at least 100,000 CD8 T cells, and (3) use of a background control sample to appropriately set the analytical gates. We also provide more insight into the limitations of the assay and identified additional protocol steps that potentially impact the quality of data generated and therefore should serve as primary targets for systematic analysis in future panels. Finally, we propose initial guidelines for harmonizing assay performance which include the introduction of standard operating protocols to allow for adequate training of technical staff and auditing of test analysis procedures.


Asunto(s)
Vacunas contra el Cáncer/inmunología , Técnicas de Laboratorio Clínico/normas , Guías como Asunto , Cooperación Internacional , Fragmentos de Péptidos/metabolismo , Bioensayo , Antígeno HLA-A2/inmunología , Antígeno HLA-A2/metabolismo , Humanos , Fragmentos de Péptidos/inmunología , Multimerización de Proteína
17.
J Transl Med ; 6: 81, 2008 Dec 23.
Artículo en Inglés | MEDLINE | ID: mdl-19105846

RESUMEN

The International Society for the Biological Therapy of Cancer (iSBTc) has initiated in collaboration with the United States Food and Drug Administration (FDA) a programmatic look at innovative avenues for the identification of relevant parameters to assist clinical and basic scientists who study the natural course of host/tumor interactions or their response to immune manipulation. The task force has two primary goals: 1) identify best practices of standardized and validated immune monitoring procedures and assays to promote inter-trial comparisons and 2) develop strategies for the identification of novel biomarkers that may enhance our understating of principles governing human cancer immune biology and, consequently, implement their clinical application. Two working groups were created that will report the developed best practices at an NCI/FDA/iSBTc sponsored workshop tied to the annual meeting of the iSBTc to be held in Washington DC in the Fall of 2009. This foreword provides an overview of the task force and invites feedback from readers that might be incorporated in the discussions and in the final document.


Asunto(s)
Biomarcadores , Inmunoterapia , Investigación , Ensayos Clínicos como Asunto , Educación , Humanos , Neoplasias/diagnóstico , Neoplasias/inmunología , Neoplasias/patología , Neoplasias/fisiopatología , Reproducibilidad de los Resultados , Investigación/economía , Proyectos de Investigación , Estados Unidos , United States Food and Drug Administration
18.
Methods Mol Biol ; 1808: 9-30, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29956170

RESUMEN

Much has been written about Elispot and how to optimally run the assay for a wide variety of applications. But only a limited number of articles exist addressing the analysis step, the plate evaluation. Comparing that fact with the vast amount of analysis advise available for other single cell immune assay, for example, intracellular cytokine staining, the overall impression may be that Elispot evaluation is just simple enough to not require extensive elaboration and guidance. At first thought this appears reasonable because how difficult can it be counting colored spots on a white background. In addition, automated Elispot readers were already introduced more than 20 years ago (Herr et al., J Immunol Methods 203, 141-152, 1997), easing the strenuous load of manual counting and providing means to decrease the subjectivity in Elispot analysis. Just shortly thereafter however, the first report was published about the subjectivity and operator-dependency of plate evaluation even when using automated reader systems (Janetzki et al., J Immunol Methods 291, 175-183, 2004). Later, the plate evaluation was identified as a main factor causing variability in Elispot results, triggering the inclusion of recommendations on handling of artifacts and the audits of plate reading results in the Initial Elispot Harmonization guidelines (Janetzki et al., Cancer Immunol Immunother 57, 303-315, 2008; Britten et al., Cancer Immunol Immunother 57, 289-302, 2008). In follow-up, a large international study with 75 laboratories was conducted to address the current approaches taken to evaluate Elispot plates and to establish consensus guidelines for plate evaluation (Janetzki et al., Nat Protoc 10, 1098-1115, 2015). This article addresses the special challenges of plate evaluation, gives explanations for unusual observation, and provides overall recommendations on how to work through the labyrinth of available algorithms and reader settings to obtain reliable Elispot data.


Asunto(s)
Biología Computacional , Ensayo de Immunospot Ligado a Enzimas , Algoritmos , Biología Computacional/métodos , Análisis de Datos , Ensayo de Immunospot Ligado a Enzimas/métodos , Ensayo de Immunospot Ligado a Enzimas/normas , Programas Informáticos
19.
J Immunol Methods ; 459: 90-93, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29859231

RESUMEN

The ELISpot assay prevails as one of the most sensitive and meaningful assays for the detection of antigen-specific, effector immune responses. Acquisition of cellular analyte for ELISpot analysis is typically not problematic when derived from tissues enriched in lymphocytes (e.g., lymphoid organs and blood); however, cell processing becomes more difficult when lymphocytes represent only a very minor population relative to the source tissue, especially when the source tissue is in limited supply (e.g., small mouse tumors). Traditional enzymatic-based methods for dissociating tumors often result in poor yields, inconsistent lymphocyte enrichment, and can have deleterious effects on lymphocyte phenotype and function. To address these limitations, we have developed an enzyme-free protocol for processing tumor infiltrating lymphocytes (TILs) from small mouse tumors, which enables the enumeration of antigen-specific effector lymphocytes using ELISpot analysis. This procedure is predicated on the dissociation of tumor tissue using gentle agitation with a paddle blender followed by a brief in vitro culture period to remove adherent cells, as well as to revive lymphocytes from a non-responsive state. Although this method is demonstrated with mouse intracerebral tumors, we have found that this protocol is applicable to peripheral tumors and may likely extend to alternative tissue sources wherein lymphocytes exist in low numbers.


Asunto(s)
Separación Celular/métodos , Ensayo de Immunospot Ligado a Enzimas , Linfocitos Infiltrantes de Tumor/citología , Neoplasias/inmunología , Linfocitos T/citología , Animales , Enzimas , Ratones , Ratones Endogámicos C57BL
20.
J Immunother Cancer ; 5(1): 29, 2017 03 21.
Artículo en Inglés | MEDLINE | ID: mdl-28653584

RESUMEN

This report summarizes the symposium, 'Immunotherapy Biomarkers 2016: Overcoming the Barriers', which was held on April 1, 2016 at the National Institutes of Health in Bethesda, Maryland. The symposium, cosponsored by the Society for Immunotherapy of Cancer (SITC) and the National Cancer Institute (NCI), focused on emerging immunotherapy biomarkers, new technologies, current hurdles to further progress, and recommendations for advancing the field of biomarker development.


Asunto(s)
Biomarcadores de Tumor/metabolismo , Inmunoterapia/métodos , Neoplasias/terapia , Congresos como Asunto , Humanos , Maryland , National Cancer Institute (U.S.) , Microambiente Tumoral , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA