Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Am Heart J ; 274: 65-74, 2024 08.
Artículo en Inglés | MEDLINE | ID: mdl-38701961

RESUMEN

BACKGROUND: There has not been a consensus on the prothesis sizing strategy in type 0 bicuspid aortic stenosis (AS) patients undergoing transcatheter aortic valve replacement (TAVR). Modifications to standard annular sizing strategies might be required due to the distinct anatomical characteristics. We have devised a downsizing strategy for TAVR using a self-expanding valve specifically for patients with type 0 bicuspid AS. The primary aim of this study is to compare the safety and efficacy of downsizing strategy with the Standard Annulus Sizing Strategy in TAVR for patients with type 0 bicuspid AS. TRIAL DESIGN: It is a prospective, multi-center, superiority, single-blinded, randomized controlled trial comparing the Down Sizing and Standard Annulus Sizing Strategy in patients with type 0 bicuspid aortic stenosis undergoing transcatheter aortic valve replacement. Eligible participants will include patients with severe type 0 bicuspid AS, as defined by criteria such as mean gradient across aortic valve ≥40 mmHg, peak aortic jet velocity ≥4.0 m/s, aortic valve area (AVA) ≤1.0 cm², or AVA index ≤0.6 cm2/m2. These patients will be randomly assigned, in a 1:1 ratio, to either the Down Sizing Strategy group or the Standard Sizing Strategy group. In the Down Sizing Strategy group, a valve one size smaller will be implanted if the "waist sign" manifests along with less than mild regurgitation during balloon pre-dilatation. The primary end point of the study is a composite of VARC-3 defined device success, absence of both permanent pacemaker implantation due to high-degree atrioventricular block and new-onset complete left bundle branch block. CONCLUSION: This study will compare the safety and efficacy of Down Sizing Strategy with the Standard Annulus Sizing Strategy and provide valuable insights into the optimal approach for sizing in TAVR patients with type 0 bicuspid AS. We hypothesize that the Down Sizing Strategy will demonstrate superiority when compared to the Standard Annulus Sizing Strategy. (Down Sizing Strategy (HANGZHOU Solution) vs Standard Sizing Strategy TAVR in Bicuspid Aortic Stenosis (Type 0) (TAILOR-TAVR), NCT05511792).


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/complicaciones , Estudios Prospectivos , Método Simple Ciego , Reemplazo de la Válvula Aórtica Transcatéter/métodos
2.
J Med Internet Res ; 26: e41843, 2024 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-39028996

RESUMEN

BACKGROUND: There are limited data available on the development of arrhythmias in patients at risk of high-degree atrioventricular block (HAVB) or complete heart block (CHB) following transcatheter aortic valve replacement (TAVR). OBJECTIVE: This study aimed to explore the incidence and evolution of arrhythmias by monitoring patients at risk of HAVB or CHB after TAVR using smartwatches. METHODS: We analyzed 188 consecutive patients in the prospective SMART TAVR (smartwatch-facilitated early discharge in patients undergoing TAVR) trial. Patients were divided into 2 groups according to the risk of HAVB or CHB. Patients were required to trigger a single-lead electrocardiogram (ECG) recording and send it to the Heart Health App via their smartphone. Physicians in the central ECG core lab would then analyze the ECG. The incidence and timing of arrhythmias and pacemaker implantation within a 30-day follow-up were compared. All arrhythmic events were adjudicated in a central ECG core lab. RESULTS: The mean age of the patients was 73.1 (SD 7.3) years, of whom 105 (55.9%) were men. The mean discharge day after TAVR was 2.0 (SD 1.8) days. There were no statistically significant changes in the evolution of atrial fibrillation or atrial flutter, Mobitz I, Mobitz II, and third-degree atrial ventricular block over time in the first month after TAVR. The incidence of the left bundle branch block (LBBB) increased in the first week and decreased in the subsequent 3 weeks significantly (P<.001). Patients at higher risk of HAVB or CHB received more pacemaker implantation after discharge (n=8, 9.6% vs n=2, 1.9%; P=.04). The incidence of LBBB was higher in the group with higher HAVB or CHB risk (n=47, 56.6% vs n=34, 32.4%; P=.001). The independent predictors for pacemaker implantation were age, baseline atrial fibrillation, baseline right bundle branch block, Mobitz II, and third-degree atrioventricular block detected by the smartwatch. CONCLUSIONS: Except for LBBB, no change in arrhythmias was observed over time in the first month after TAVR. A higher incidence of pacemaker implantation after discharge was observed in patients at risk of HAVB or CHB. However, Mobitz II and third-degree atrioventricular block detected by the smartwatch during follow-ups were more valuable indicators to predict pacemaker implantation after discharge from the index TAVR. TRIAL REGISTRATION: ClinicalTrials.gov NCT04454177; https://clinicaltrials.gov/study/NCT04454177.


Asunto(s)
Arritmias Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Masculino , Femenino , Anciano , Arritmias Cardíacas/etiología , Arritmias Cardíacas/fisiopatología , Estudios Prospectivos , Anciano de 80 o más Años , Electrocardiografía , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/terapia
3.
BMC Cardiovasc Disord ; 22(1): 164, 2022 04 12.
Artículo en Inglés | MEDLINE | ID: mdl-35413789

RESUMEN

BACKGROUND: Unlike N-terminal pro-B-type natriuretic peptide (NT-proBNP), which have been extensively studied, little is known about the role of N-terminal pro-C-type natriuretic peptide (NT-proCNP) for predicting survival post transcatheter aortic valve replacement (TAVR). METHODS: A total of 309 patients were included in the analysis. Patients were grouped into quartiles (Q1-4) according to the baseline NT-proCNP value. Blood for NT-proCNP analysis was obtained prior to TAVR procedure. The primary endpoint was mortality after a median follow-up of 32 months. Multivariable Cox proportional hazards regression models analyzed prognostic factors. The predictive capability was compared between NT-proBNP and NT-proCNP using receiver operator curve (ROC) analysis. RESULTS: A total of 309 subjects with the mean age of 76.8 ± 6.3 years, among whom 58.6% were male, were included in the analysis. A total of 58 (18.8%) patients died during follow-up. Cox multivariable analyses indicated society of thoracic surgeons (STS)-score was a strong independent predictor for mortality (hazard ratio (HR) 1.08, 95% confidential interval (CI) 1.05-1.12, P < 0.001). Elevated NT-proCNP was associated with a higher risk of cardiovascular mortality (HR 1.02, 95% CI 1.00-1.03, P = 0.025) and All-cause mortality (HR 1.01, 95% CI 1.00-1.03, P = 0.027), whereas NT-proBNP showed a small effect size on mortality. ROC analysis indicated that NT-proCNP was superior to NT-proBNP for TAVR risk evaluation in patients with left ventricular ejection fraction (LVEF) < 50% [(Area under the curve (AUC)-values of 0.79 (0.69; 0.87) vs. 0.59 (0.48; 0.69), P = 0.0453]. CONCLUSIONS: NT-proCNP and STS-Score were the independent prognostic factors of mortality among TAVR patients. Furthermore, NT-proCNP was superior to NT-proBNP for TAVR risk evaluation in patients with LVEF < 50%. Trial registration NCT02803294, 16/06/2016.


Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Biomarcadores , Diuréticos , Humanos , Masculino , Péptido Natriurético Encefálico , Péptido Natriurético Tipo-C , Fragmentos de Péptidos , Pronóstico , Volumen Sistólico , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Vasodilatadores , Función Ventricular Izquierda
4.
Cardiology ; 145(1): 27-34, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31722361

RESUMEN

AIMS: Permanent pacemaker (PPM) implantation is one of the most common complications after transcatheter aortic valve replacement (TAVR). We studied the incidence of PPM implantation and identified the predictors in patients who underwent TAVR in a Chinese population. METHODS AND RESULTS: A total of 256 patients who underwent TAVR with self-expandable valves were included. The incidence of PPM implantation in our study population was 14.8%. In patients who received PPM implantation, the proportion of bicuspid aortic valve (BAV) patients was much lower compared to tricuspid aortic valve (TAV) patients (18.4 vs. 81.6%, p < 0.05). Patients with BAV were associated with a significantly lower PPM implantation rate and shallower implantation depth compared to patients with TAV (6.4 vs. 21.7% and 4.2 ± 4.4 vs. 6.2 ± 5.0 mm, respectively, p < 0.05 for both). In the multivariable logistic regression analysis, prior right bundle branch block (RBBB; OR 8.3, 95% CI 2.2-32.1, p < 0.05), implantation depth (OR 1.3, 95% CI 1.1-1.5, p = 0.01), and TAV (OR 4.7, 95% CI 1.5-14.4, p < 0.05) were independent predictors of PPM implantation after TAVR. There was no difference in 30-day and 1-year all-cause mortality between the 2 groups. CONCLUSIONS: The incidence of PPM implantation in patients with self-expandable valves after TAVR was 14.8% in our cohort study. Independent predictors of PPM implantation included prior RBBB, TAV, and implantation depth at the noncoronary sinus side. TAVR in BAV with a supra-annular structure-based sizing strategy might decrease the risk of PPM implantation.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Arritmias Cardíacas/terapia , Estimulación Cardíaca Artificial/efectos adversos , Marcapaso Artificial/estadística & datos numéricos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/fisiopatología , Estimulación Cardíaca Artificial/mortalidad , China/epidemiología , Electrocardiografía , Femenino , Prótesis Valvulares Cardíacas , Humanos , Incidencia , Modelos Logísticos , Masculino , Análisis Multivariante , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
5.
Herz ; 45(8): 726-738, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31555891

RESUMEN

BACKGROUND: Obstructive sleep apnea syndrome (OSAS) is associated with cardiovascular mortality and morbidity. Several studies have reported that it affects the left ventricle; however, large randomized controlled trials are lacking. The current study aimed to summarize the association between OSAS and left ventricular (LV) structure and function. METHODS: Electronic databases (PubMed, Embase, and Cochrane) and references were searched for articles published until March 2018. A systematic review and meta-analysis were performed to assess LV structure and function in OSAS patients based on echocardiography. RESULTS: In total, 17 studies with 747 OSAS patients and 426 control participants were included. Patients with OSAS showed an increase in LV diastolic diameter (weighted mean difference [WMD], 95% CI: 1.24 [0.68, 1.80]; p < 0.001), LV systolic diameter (WMD, 95% CI: 1.14 [0.47, 1.81]; p = 0.001), and LV mass (WMD, 95% CI: 35.34 [20.67, 50.00]; p < 0.001). In addition, left ventricular ejection fraction (LVEF) significantly decreased in the OSAS group compared with the controls (WMD, 95% CIs: -1.82 [-2.76, -0.87]; p < 0.001), and the reduction in LVEF was consistent with the severity of OSAS. The OSAS group also showed an increase in left atrial diameter (WMD, 95% CI: 2.13 [1.48, 2.77]; p < 0.001) and left atrial diameter volume index (WMD, 95% CIs: 3.96 [3.32, 4.61]; p < 0.001). CONCLUSION: Obstructive sleep apnea syndrome leads to atrial dilatation, left ventricular hypertrophy, enlargement, mass increase and reduction of systolic function. Treatments for OSAS might be beneficial for the preservation of left cardiac structure and function.


Asunto(s)
Apnea Obstructiva del Sueño , Disfunción Ventricular Izquierda , Ecocardiografía , Humanos , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda , Remodelación Ventricular
6.
Cardiology ; 141(3): 132-140, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30517917

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a recent and an effective treatment option for high- or extreme-surgical-risk patients with symptomatic severe aortic stenosis. However, pure severe native aortic valve regurgitation (NAVR) without aortic stenosis remains a contraindication to TAVR. The aim of our systemic review analysis was to evaluate TAVR in patients with pure NAVR. METHODS: We searched the published articles in the PubMed and Web of Science databases (2002-2017) using the Boolean operators for studies of NAVR patients undergoing TAVR. Reference lists of all returned articles were searched recursively for other relevant citations. Pooled estimates were calculated using a random-effects meta-analysis. RESULTS: Finally, a total of 10 studies were included in this analysis. The CoreValve was more frequently used with a lower rate of device success and a higher rate of residual aortic regurgitation. The new-generation transcatheter heart valves (THVs) performed a significantly higher rate with less residual aortic regurgitation and a success rate close to 100%. The 30-day all-cause mortality rates ranged from 0 to 30% with an estimate summary rate of 9% (95% CI: 5-15%; I2 = 33%). Cerebrovascular events, major or life-threatening bleeding, major vascular complications, acute kidney disease, and new permanent pacemaker implantation occurred similarly in both the new- and old-generation THV devices. CONCLUSIONS: Aortic regurgitation remains a challenging pathology for TAVR. TAVR is a feasible and reasonable option for carefully selected patients with pure aortic regurgitation.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Falla de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/mortalidad , Humanos , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
7.
Cardiology ; 139(3): 151-158, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29353286

RESUMEN

OBJECTIVES: The importance of thrombocytopenia (TP) has been discussed previously. However, data are still limited, especially on predictors of TP. We sought to investigate predictors of TP after transcatheter aortic valve replacement (TAVR), in particular, clinically significant TP. METHODS: We reviewed a total of 123 consecutive patients undergoing TAVR in our medical center. They were stratified into 3 groups according to the nadir platelet count post-TAVR: no/mild TP, moderate TP, and severe TP. Clinically significant TP, also known as major TP, was defined as moderate-to-severe TP (a nadir platelet count <100 × 109/L and a >50% decrease in platelet count). RESULTS: Baseline platelet, baseline hemoglobin, general anesthesia (GA), valve malpositioning and post-TAVR left ventricular ejection fraction were found to be predictors of post-TAVR nadir platelet count. Major TP was associated with a higher risk of major bleeding (OR 3.524, 95% CI 1.546-8.031) and 1-month mortality (OR 11.226, 95% CI 1.208-104.328). Age (OR 1.110, 95% CI 1.014-1.215) and GA (OR 6.494, 95% CI 2.058-20.408) were predictors of major TP. CONCLUSION: Post-TAVR nadir platelet count can be predicted based on baseline and procedural data. Old age and GA contribute to clinically significant TP.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Trombocitopenia/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Anciano , Anciano de 80 o más Años , China , Femenino , Mortalidad Hospitalaria , Humanos , Modelos Logísticos , Masculino , Análisis Multivariante , Recuento de Plaquetas , Estudios Retrospectivos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Función Ventricular Izquierda
8.
Circ Cardiovasc Qual Outcomes ; 17(1): e010066, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38088154

RESUMEN

BACKGROUND: This study aims to evaluate limited data about daily physical activity patterns, influential factors, and their association with 1-year mortality or rehospitalization after transcatheter aortic valve replacement (TAVR) through smartwatches. METHODS: Consecutive severe aortic stenosis patients undergoing elective transfemoral TAVR in a Chinese tertiary hospital were enrolled from July 2021 to May 2022 and received a Huawei smartwatch at least 1 day before TAVR. The primary outcome was a composite of all-cause mortality or hospital readmission within 1 year. Linear mixed-effects models were applied to determine influential factors of daily step counts, and Cox proportional hazard regression models were to estimate the association between baseline step counts within 1 month since discharge and composite outcome from months 2 to 12. The dose-response association was assessed using restricted cubic spline curves. RESULTS: A total of 222 participants and 59 469 valid monitoring person-day records were included (mean age, 72.7 years; 61% women). Step counts increased rapidly within the first 2 months (P<0.001), followed by a slower increase for those without composite outcomes (P=0.029) and a gradual decrease for those who developed composite outcomes (P<0.001). In multivariate linear mixed models, a 1-m increase in baseline 6-minute walk test and a 1-month delay after discharge were associated with 4 (95% CI, 1-7) and 170 (95% CI, 145-194) additional step counts, respectively. In restricted cubic spline analysis, the hazard ratio declined progressively until ≈5000 steps per day, after which they leveled. Below 5000 steps, the adjusted hazard ratio of composite outcome associated with each 1000-step count increase was 0.67 (0.50-0.89; P=0.007). However, above 5000 steps, step counts were not significantly associated with the composite outcome (P=0.645), with a hazard ratio of 1.12 (0.70-1.79). CONCLUSIONS: Daily step counts rapidly increased within the first 2 months post-TAVR. Increased physical activity was associated with a lower risk of 1-year mortality or rehospitalization after TAVR for patients with daily step counts below 5000. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04454177.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Dispositivos Electrónicos Vestibles , Humanos , Femenino , Anciano , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Ejercicio Físico , Válvula Aórtica/cirugía , Factores de Riesgo , Índice de Severidad de la Enfermedad
9.
Insights Imaging ; 15(1): 125, 2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38816554

RESUMEN

OBJECTIVE: To observe prosthetic-associated subclinical thrombotic events (PASTE) after transcatheter aortic valve implantation (TAVI) by cardiac CTA, and assess their impact on long-term patient outcomes. MATERIALS: We prospectively and consecutively enrolled 188 patients with severe aortic stenosis treated with TAVI from February 2014 to April 2017. At 5 years, 61 of 141 survived patients who had completed annual follow-up CTA (≥ 5 years) were included. We analyzed PASTE by CTA, including hypoattenuated leaflet thickening (HALT), sinus filling defect (SFD), and prosthesis filling defect (PFD). The primary outcome was a major adverse cardiovascular composite outcome (MACCO) of stroke, cardiac re-hospitalization, and bioprosthetic valve dysfunction (BVD); the secondary outcomes were bioprosthetic hemodynamics deterioration (PGmean) and cardiac dysfunction (LVEF). RESULTS: During a median follow-up time of 5.25 years, long-term incidence of HALT, SFD, and PFD were 54.1%, 37.7%, and 73.8%, respectively. In the primary outcome, SFD and early SFD were associated with the MACCO (SFD: p = 0.005; early SFD: p = 0.018), and SFD was a predictor of MACCO (HR: 2.870; 95% CI: 1.010 to 8.154, p = 0.048). In the secondary outcomes, HALT was associated with increased PGmean (p = 0.031), while persistent HALT was correlated with ΔPGmean (ß = 0.38, p = 0.035). SFD was negatively correlated with ΔLVEF (ß = -0.39, p = 0.041), and early SFD was negatively correlated with LVEF and ΔLVEF (LVEF: r = -0.50, p = 0.041; ΔLVEF: r = -0.53, p = 0.030). CONCLUSIONS: PASTE were associated with adverse long-term outcomes, bioprosthetic hemodynamics deterioration, and cardiac dysfunction. In particular, SFD was a predictor of MACCO and may be a potential target for anticoagulation after TAVI (NCT02803294). REGISTRATION: URL: https://www. CLINICALTRIALS: gov ; Unique identifier: NCT02803294. CRITICAL RELEVANCE STATEMENT: PASTE, especially SFD, after TAVI based on cardiac CTA findings impacts the long-term outcomes of patients which is a predictor of long-term major adverse outcomes in patients and may be a potential target for anticoagulation after TAVI. KEY POINTS: Transcatheter aortic valve implantation is being used more often; associated subclinical thromboses have not been thoroughly evaluated. Prosthetic-associated subclinical thrombotic events were associated with adverse outcomes, bioprosthetic hemodynamics deterioration, and cardiac dysfunction. Studies should be directed at these topics to determine if they should be intervened upon.

10.
Front Cardiovasc Med ; 11: 1432235, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39484012

RESUMEN

Background: Coronary obstruction (CO) is a rare but devasting complication during transcatheter aortic valve replacement (TAVR). Objectives: We aim to demonstrate that the predicted distance between the coronary ostia and the closest structure derived with patient-specific computer simulation is associated with CO risk during TAVR. Methods: We retrospectively analysed 14 aortic stenosis patients who underwent TAVR through finite element simulation. The frame deformation predicted with patient-specific computer simulation was qualitatively and quantitatively compared to the post-operative device deformation. The minimum distance between each coronary ostium and the closest structure was calculated and compared in patients who developed CO, at high risk of CO, and at no risk of CO. Results: Four patients experienced CO during TAVR, 5 patients were at high risk of CO, and the remaining 5 patients had no risk of CO. A high coefficient of determination was obtained for all measurements extracted from the simulated device and the post-operative device (≥0.95). Simulations predicted shorter distance between the coronary ostium and the closest structure in patients who experienced CO, compared to patients at high risk of CO or who did not experience this complication (right coronary: 5.9 vs. 6.8 vs. 8.8 mm, left coronary: 3.0 vs. 3.3 vs. 6.5 mm respectively). Conclusions: The distance between the coronary ostium and the closest structure was lower in patients who experienced CO during TAVR through patient-specific computational simulation. This technology enables coronary obstruction analysis before TAVR in the future.

11.
World J Emerg Med ; 13(1): 32-39, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35003413

RESUMEN

BACKGROUND: Anemia is prevalent in patients undergoing transcatheter aortic valve replacement (TAVR) and has been linked to impaired outcomes after the procedure. Few studies have evaluated the impact of anemia and new ischemic lesions post TAVR. METHODS: We prospectively enrolled 158 patients who received TAVR in our center. Anemia was defined according to the World Health Organization criteria as hemoglobin <12 g/dL in women and <13 g/dL in men. All patients underwent diffusion-weighted magnetic resonance imaging (DW-MRI) procedure before and within 4-7 days after TAVR. RESULTS: Anemia was present in 85 (53.8%) patients who underwent TAVR, and 126 (79.7%) patients had 718 new DW-MRI positive lesions with a mean of 4.54±5.26 lesions per patient. The incidence of new ischemic lesions was 81.2% in patients with anemia versus 78.1% in patients without anemia (P=0.629). Moreover, anemic patients had bigger total volume/lesions in the anterior cerebral artery/middle cerebral artery (ACA/MCA) and MCA regions compared to the non-anemic patients (31.89±55.78 mm3 vs. 17.08±37.39 mm3, P=0.049; and 54.54±74.72 mm3 vs. 33.75±46.03 mm3, P=0.034). Anemia was independently associated with the volume/lesion in the ACA/MCA (ß=16.796, 95% confidence interval [95% CI] 2.001 to 31.591, P=0.026) and in the MCA zone (ß=0.020, 95% CI 0.001 to 0.040, P=0.041). CONCLUSIONS: Patients with pre-procedural anemia may have bigger total volume/lesions in the ACA/MCA and MCA regions compared to the non-anemic patients. Whether the consequences of bigger total volume/lesions impact neurological and cognitive outcomes remains to be investigated.

12.
Int J Cardiol Heart Vasc ; 42: 101101, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35937949

RESUMEN

Background: Decreased length of stay in the index hospitalization is a tendency in transcatheter aortic valve replacement (TAVR) era. In this study, we aim to evaluate the feasibility and safety of next-day discharge (NDD) in bicuspid aortic valve (BAV) patients following TAVR. Methods: The study analyzed patients who received TAVR in 2019 to 2022. Thirty-day mortality and readmission rate were compared between BAV and tricuspid aortic valve (TAV) patients. Results: The proportion of NDD was similar between the BAV and TAV group (45.3 % vs 41.3 %, p = 0.487). In NDD patients, the lower age (72.0 [67.0, 77.0] yrs vs 74.0 [70.0, 80.0] yrs, p = 0.011) and STS score (2.33 [1.56, 3.54] % vs 3.82 [2.38, 5.70] %, p < 0.001) were observed in the BAV group. The NDD BAV patients had higher proportion of post-dilatation (74.3 % vs 50.7 %, p = 0.003) when compared with the TAV patients. The NDD patients was safe with no death both in BAV and TAV patients at 30-day follow-up. Moreover, the readmission rate was comparable between BAV and TAV patients who discharged on the next day after TAVR (8.1 % vs 14.0 %, p = 0.397). Conclusions: NDD after TAVR was feasible and safe in both BAV and TAV patients. The younger BAV patients with fast recovery deserve the next-day discharge after TAVR.

13.
Front Cardiovasc Med ; 9: 931595, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35966563

RESUMEN

Background: Coronary occlusion is an uncommon but fatal complication of transcatheter aortic valve replacement (TAVR) with a poor prognosis. Case Presentation: A patient with symptomatic severe bicuspid aortic valve stenosis was admitted to a high-volume center specializing in transfemoral TAVR with self-expanding valves. No anatomical risk factors of coronary occlusion were identified on pre-procedural computed tomography analysis. The patient was scheduled for a transfemoral TAVR with a self-expanding valve. Balloon pre-dilatation prior to prosthesis implantation was routinely used for assessing the supra-annular structure and assessing the risk of coronary occlusion. Immediately after the tubular balloon inflation, fluoroscopy revealed that the right coronary artery was not visible, and the flow in the left coronary artery was reduced. The patient would be at high-risk of coronary occlusion if a long stent self-expanding valve was implanted. Therefore, our heart team decided to suspend the ongoing procedure. A transapical TAVR with a 23 mm J-valve was performed 3 days later. The prosthesis was deployed at a proper position without blocking the coronary ostia and the final fluoroscopy showed normal flow in bilateral coronary arteries with the same filling as preoperatively. Discussion: Our successful case highlights the importance of a comprehensive assessment of coronary risk and a thorough understanding of the TAVR procedure for the heart team. A short-stent prosthesis is feasible for patients at high risk of coronary occlusion. Most importantly TAVR should be called off even if the catheter has been introduced when an extremely high risk of coronary obstruction is identified during the procedure and no solution can be found.

14.
EuroIntervention ; 18(3): 193-202, 2022 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-35044300

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) might be a feasible treatment option for more patients with bicuspid aortic valve (BAV) stenosis. However, long-term follow-up data in this population are scarce. AIMS: The aim of this study was to evaluate three-year outcomes after TAVI in patients with BAV. METHODS: A total of 246 consecutive patients who underwent TAVI at a single centre in China between March 2013 and February 2018 were enrolled in this study. Clinical outcomes, health status and echocardiography were followed and recorded for three years. RESULTS: Among 109 (44.3%) BAV patients, 61.5% were Type 0 and 36.7% were Type 1 BAV patients. BAV patients were younger (75 vs 77 years, p=0.041) and had a lower Society of Thoracic Surgeons (STS) score (5.09 vs 6.00, p=0.026) compared to tricuspid aortic valve (TAV) patients. There were no differences in three-year survival rates between bicuspid and tricuspid patients (87.1% vs 79.5%, log-rank p=0.126). Multivariate Cox regression analysis adjusting for confounding factors revealed a similar risk of all-cause mortality in the BAV population (hazard ratio [HR] 0.86, 95% confidence interval [CI]: 0.44-1.70, p=0.666). Except for the rate of permanent pacemaker implantation that was lower in BAV patients (11.9% vs 21.9%, p=0.041), the incidence of other clinical adverse events was comparable between the two groups. Both BAV and TAV patients showed an obvious improvement in valve haemodynamics, which was sustained for three years. In addition, similar left ventricular reverse remodelling was found during follow-up. CONCLUSIONS: BAV patients showed similar satisfactory three-year clinical outcomes, persistent valve haemodynamics improvement, and obvious cardiac reverse remodelling after TAVI compared to TAV patients.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Estenosis de la Válvula Mitral , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Humanos , Estenosis de la Válvula Mitral/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Remodelación Ventricular
15.
Front Cardiovasc Med ; 8: 732784, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34708088

RESUMEN

Background: Patient-specific computer simulation of transcatheter aortic valve replacement (TAVR) can provide unique insights in device-patient interaction. Aims: This study was to compare transcatheter aortic valve sealing behavior in patients with bicuspid aortic valves (BAV) and tricuspid aortic valves (TAV) through patient-specific computational modeling. Methods: Patient-specific computer simulation was retrospectively performed with FEops HEARTguide for TAVR patients. Simulation output was compared with postprocedural computed tomography and echocardiography to validate the accuracy. Skirt malapposition was defined by a distance larger than 1 mm based on the predicted device-patient interaction by quantifying the distance between the transcatheter heart valve (THV) skirt and the surrounding anatomical regions. Results: In total, 43 patients were included in the study. Predicted and observed THV frame deformation showed good correlation (R 2 ≥ 0.90) for all analyzed measurements (maximum diameter, minimum diameter, area, and perimeter). The amount of predicted THV skirt malapposition was strongly linked with the echocardiographic grading of paravalvular leakage (PVL). More THV skirt malapposition was observed for BAV cases when compared to TAV cases (22.7 vs. 15.5%, p < 0.05). A detailed analysis of skirt malapposition showed a higher degree of malapposition in the interleaflet triangles section for BAV cases as compared to TAV patients (11.1 vs. 5.8%, p < 0.05). Conclusions: Patient-specific computer simulation of TAVR can accurately predict the behavior of the Venus A-valve. BAV patients are associated with more malapposition of the THV skirt as compared to TAV patients, and this is mainly driven by more malapposition in the interleaflet triangle region.

17.
World J Emerg Med ; 11(1): 33-36, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31893001

RESUMEN

BACKGROUND: MAVERIC (Mitral Valve Repair Clinical Trial) validates the safety and efficacy of the ARTO system. We here report the first two successful cases of utilizing the ARTO system in patients with symptomatic heart failure (HF) with functional mitral regurgitation (FMR) in Asia. METHODS: Two patients, aged 70 and 63, had severe HF with FMR. Transesophageal echocardiography confirmed that the left ventricular ejection fractions were less than 50% with severe mitral regurgitation (MR) in both patients. Optimizing drug treatment could not mitigate their symptoms. Therefore, we used the ARTO system to repair the mitral valve for these patients on March 5 and 6, 2019, respectively. RESULTS: Mitral valve repairs using the ARTO system were successfully performed under general anaesthesia for these two patients. MR was decreased immediately after the procedures in both patients. The 30-day and 3-month transthoracic echocardiography (TTE) revealed a moderate to severe MR in both patients, and the New York Heart Association (NYHA) scales were also partially improved. CONCLUSION: The first two cases in Asia indicate that the ARTO system is feasible for patients with heart failure with FMR, and the patient selection appears to be crucial.

18.
J Am Coll Cardiol ; 76(22): 2579-2590, 2020 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-33243378

RESUMEN

BACKGROUND: An increasing number of bicuspid aortic valve (BAV) patients are undergoing transcatheter aortic valve replacement (TAVR), but the risk of brain injury in diffusion-weighted magnetic resonance imaging (DW-MRI) is currently unknown. OBJECTIVES: This study sought to evaluate the risk of brain injury in BAV patients following TAVR. METHODS: A total of 204 consecutive severe aortic stenosis patients who underwent TAVR were enrolled. A total of 83 (40.7%) patients were BAV patients, and the other 121 patients were tricuspid aortic valve (TAV) patients. All patients received DW-MRI at baseline, and after TAVR. RESULTS: Median ages (76 years [interquartile range (IQR): 71 to 81 years] vs. 79 years [IQR: 74 to 83 years]; p = 0.004) and Society of Thoracic Surgeons scores (4.87 [IQR: 3.72 to 8.54] vs. 6.38 [IQR: 3.96 to 9.50]; p = 0.044) of the BAV and TAV patients were significantly different, while the overt stroke rates (2.4% vs. 1.7%; p = 0.704) were comparable between the 2 groups. BAV patients were associated with higher number of new lesions (4.0 [IQR: 1.0 to 8.0] vs. 2.0 [IQR: 1.0 to 5.0]; p = 0.008), total lesion volume (290 mm3 [IQR: 70 to 930 mm3] vs. 140 mm3 [IQR: 35 to 480 mm3]; p = 0.008), and the volume per lesion (70.0 mm3 [IQR: 45.0 to 115.0 mm3] vs. 57.5 mm3 [IQR: 24.5 to 93.0 mm3]; p = 0.037) in DW-MRI. Moreover, the proportion of patients with lesions larger than 1 cm3 (28.6% vs. 10.9%; p = 0.005) was higher in BAV patients than in TAV patients. CONCLUSIONS: BAV patients may encounter more severe brain injuries not only due to greater number of lesions, but also due to larger lesion size in the early phase after TAVR. (Transcatheter Aortic Valve Replacement Single Center Registry in Chinese Population [TORCH]; NCT02803294).


Asunto(s)
Válvula Aórtica , Encéfalo/diagnóstico por imagen , Accidente Cerebrovascular Isquémico , Complicaciones Posoperatorias , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Imagen de Difusión por Resonancia Magnética/métodos , Imagen de Difusión por Resonancia Magnética/estadística & datos numéricos , Femenino , Humanos , Accidente Cerebrovascular Isquémico/diagnóstico , Accidente Cerebrovascular Isquémico/etiología , Masculino , Evaluación de Procesos y Resultados en Atención de Salud , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos
19.
World J Emerg Med ; 10(4): 197-204, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31534592

RESUMEN

BACKGROUND: Current data is lacking about the progression of ascending aortic dilatation after transcatheter aortic valve replacement (TAVR) in aortic stenosis (AS) patients with bicuspid aortic valve (BAV) and tricuspid aortic valve (TAV). This study aims to assess the ascending aortic dilatation rate (mm/year) after TAVR in patients with BAV versus TAV using a multidetector computed tomography (MDCT) follow-up and to determine the predictors of ascending aortic dilatation rate. METHODS: Severe AS patients undergoing TAVR from March 2013 to March 2018 at our center with MDCT follow-ups were included. BAV and TAV were identified using baseline MDCT. Baseline and follow-up MDCT images were analyzed, and the diameters of ascending aorta were measured. Study end point is ascending aortic dilatation rate (mm/year). Furthermore, factors predicting ascending aortic dilatation rate were also investigated. RESULTS: Two hundred and eight patients were included, comprised of 86 BAV and 122 TAV patients. Five, 4, 3, 2, and 1-year MDCT follow-ups were achieved in 7, 9, 30, 46, and 116 patients. The ascending aortic diameter was significantly increased after TAVR in both BAV group (43.7±4.4 mm vs. 44.0±4.5 mm; P<0.001) and TAV group (39.1±4.8 mm vs. 39.7±5.1 mm; P<0.001). However, no difference of ascending aortic dilatation rate was found between BAV and TAV group (0.2±0.8 mm/year vs. 0.3±0.8 mm/year, P=0.592). Multivariate linear regression revealed paravalvular leakage (PVL) grade was independently associated with ascending aortic dilatation rate in the whole population and BAV group, but not TAV group. No aortic events occurred during follow-ups. CONCLUSION: Ascending aortic size continues to grow after TAVR in BAV patients, but the dilatation rate is mild and comparable to that of TAV patients. PVL grade is associated with ascending aortic dilatation rate in BAV patients post-TAVR.

20.
World J Emerg Med ; 10(3): 133-137, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31171942

RESUMEN

BACKGROUND: Transapical off-pump NeoChord procedure is a novel minimally invasive surgical repair of degenerative mitral regurgitation (MR). Here, we report the first four cases of NeoChord procedure in patients with mitral valve prolapse in mainland China. METHODS: Four patients, aged 86, 84, 80 and 60 years, with severe MR due to posterior middle scallop prolapse (P2), underwent transapical off-pump artificial chordae implantation on April 9 and 10, 2019. The procedure was performed by left mini-thoracotomy under general anaesthesia and guided by 2D and 3D dimensional transoesophageal echocardiography (TEE). RESULTS: Mitral valve repair via NeoChord procedure was successfully performed with implantation of 3 artificial chordae in the first patient and 3, 2, and 3 artificial chordae in the following patients, respectively. Intraoperative TEE and pre-discharge transthoracic echocardiography (TTE) showed only mild to moderate MR of these four patients and no postoperative complications were noted. There were no changes of TTE finding between one-month follow-up and pre-discharge. CONCLUSION: The successful NeoChord procedures in four Chinese indicate that the valve repair using the NeoChord system for Chinese population is feasible.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA