Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Respir Res ; 15: 133, 2014 Oct 29.
Artículo en Inglés | MEDLINE | ID: mdl-25359169

RESUMEN

BACKGROUND: Receptors for advanced glycation end-products (RAGE) are multiligand cell-surface receptors expressed abundantly by distal pulmonary epithelium. Our lab has discovered RAGE-mediated effects in the orchestration of lung inflammation induced by tobacco smoke and environmental pollutants; however, the specific contribution of RAGE to the progression of proximal airway inflammation is still inadequately characterized. METHODS AND RESULTS: We generated a Tet-inducible transgenic mouse that conditionally overexpressed RAGE using the club cell (Clara) secretory protein (CCSP) promoter expressed by club (Clara) cells localized to the proximal airway. RAGE was induced for 40 days from weaning (20 days of age) until sacrifice date at 60 days. Immunohistochemistry, immunoblotting, and qPCR revealed significant RAGE up-regulation when compared to non-transgenic controls; however, H&E staining revealed no detectible morphological abnormalities and apoptosis was not enhanced during the 40 days of augmentation. Freshly procured bronchoalveolar lavage fluid (BALF) from CCSP-RAGE TG mice had significantly more total leukocytes and PMNs compared to age-matched control littermates. Furthermore, CCSP-RAGE TG mice expressed significantly more tumor necrosis factor alpha (TNF-α), interleukin 7 (IL-7), and interleukin 14 (IL-14) in whole lung homogenates compared to controls. CONCLUSIONS: These data support the concept that RAGE up-regulation specifically in lung airways may function in the progression of proximal airway inflammation.


Asunto(s)
Células Epiteliales Alveolares/metabolismo , Neumonía/metabolismo , Receptor para Productos Finales de Glicación Avanzada/metabolismo , Células Epiteliales Alveolares/inmunología , Animales , Líquido del Lavado Bronquioalveolar/química , Líquido del Lavado Bronquioalveolar/inmunología , Genotipo , Mediadores de Inflamación/metabolismo , Interleucina-7/metabolismo , Interleucinas/metabolismo , Ratones Transgénicos , Infiltración Neutrófila , Fenotipo , Neumonía/genética , Neumonía/inmunología , Regiones Promotoras Genéticas , Receptor para Productos Finales de Glicación Avanzada/genética , Factor de Necrosis Tumoral alfa/metabolismo , Regulación hacia Arriba , Uteroglobina/genética , Proteínas de Transporte Vesicular
2.
Med Phys ; 34(10): 3971-81, 2007 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17985642

RESUMEN

The purpose of this study was to examine the effects of different resolution and noise levels on task performance in digital mammography. This study created an image set with images at three different resolution levels, corresponding to three digital display devices, and three different noise levels, with noise magnitudes similar to full clinical dose, half clinical dose, and quarter clinical dose. The images were read by five experienced breast imaging radiologists. The data were then analyzed to compute two accuracy statistics (overall classification accuracy and lesion detection accuracy) and performance at four diagnostic tasks (detection of microcalcifications, benign masses, malignant masses, and discrimination of benign and malignant masses). Human observer results showed decreasing display resolution had little effect on overall classification accuracy and individual diagnostic task performance, but increasing noise caused overall classification accuracy to decrease by a statistically significant 21% as the breast dose went to one quarter of its normal clinical value. The noise effects were most prominent for the tasks of microcalcification detection and mass discrimination. When the noise changed from full clinical dose to quarter clinical dose, the microcalcification detection performance fell from 89% to 67% and the mass discrimination performance decreased from 93% to 79%, while malignant mass detection performance remained relatively constant with values of 88% and 84%, respectively. As a secondary aim, the image set was also analyzed by two observer models to examine whether their performance was similar to humans. Observer models differed from human observers and each other in their sensitivity to resolution degradation and noise. The primary conclusions of this study suggest that quantum noise appears to be the dominant image quality factor in digital mammography, affecting radiologist performance much more profoundly than display resolution.


Asunto(s)
Mamografía/métodos , Mamografía/normas , Radiología/métodos , Artefactos , Presentación de Datos , Humanos , Procesamiento de Imagen Asistido por Computador , Variaciones Dependientes del Observador , Intensificación de Imagen Radiográfica , Magnificación Radiográfica , Reproducibilidad de los Resultados , Técnica de Sustracción
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA