Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 93(3): 398-403, 2019 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-30341836

RESUMEN

OBJECTIVES: The goal of this analysis was to evaluate the final 5-year safety and effectiveness of the PROMUS Element platinum-chromium everolimus-eluting stent in unselected patients treated in routine clinical practice. BACKGROUND: The prospective, open-label PROMUS Element™ European Post-Approval Surveillance Study (PE-PROVE) enrolled 1,010 "real-world" patients who received the PROMUS Element stent. Adverse event rates were low at 1-year, and the incidence of stent thrombosis was 0.6%. METHODS: The primary endpoint was target vessel failure (TVF; overall and PE stent-related), a composite of cardiac death, myocardial infarction (MI) related to the target vessel, or target vessel revascularization (TVR) at 1-year post-implantation. Five-year clinical outcomes were evaluated in overall as well as high-risk patient subgroups. RESULTS: The overall 5-year TVF rate was 14.9%, with 7.0% being related to the study stent. Cardiac death, MI and TVR related to the study stent occurred in 0.5%, 3.2%, and 5.7%, respectively. Stent thrombosis through 5-year follow-up was 1.0%. The rates of overall and study stent related TVF were numerically higher in patients with medically treated diabetes, long lesions (≥28 mm), and small diameter vessels (≤2.5 mm) compared to the overall study population. Additionally, favorable stent thrombosis rates through 5 years were reported for the PROMUS Element stent in these high-risk subgroups. CONCLUSIONS: The final 5-year data from the PE-PROVE study demonstrate favorable outcomes and low rates of adverse events with the PE stent when used in "real-world" patients with coronary artery disease.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Cromo , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Platino (Metal) , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/mortalidad , Europa (Continente) , Everolimus/efectos adversos , Femenino , Humanos , Masculino , Infarto del Miocardio/mortalidad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
2.
J Electrocardiol ; 53: 100-108, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30739055

RESUMEN

AIMS: Remote monitoring by implantable devices substantially improves management of heart failure (HF) patients by providing diagnostic day-to-day data. The use of thoracic impedance (TI) as a surrogate measure of fluid accumulation is still strongly debated. The multicenter HomeCARE-II study evaluated clinically apparent HF events in the context of remote device diagnostics, focusing on the controversial role of TI. METHODS AND RESULTS: We followed 497 patients (66.6 ±â€¯10.1 years, 77% male, QRS 139.8 ±â€¯36.0 ms, ejection fraction 26.8 ±â€¯7.0%) implanted with a CRT-D (67%) or an ICD (33%) for 21.4 ±â€¯8.1 months. An independent event committee confirmed 171 HF events of which 82 were used to develop a TI-based algorithm for the prediction of imminent cardiac decompensation. Highly inter-individual variations in patterns of TI trends were observed. The algorithm resulted in a sensitivity of 41.5% (50.0%) with 0.95 (1.34) false alerts per patient year, and a positive predictive value of 7.9% overall and 27.9% in the HF event group of patients. Averaged ratio statistics showed a significant pre-hospital decrease and a highly significant in-hospital increase in TI after intensified diuresis. Recurrent decompensations turned out to be preceded by a significantly stronger decrease of TI compared to first events with a higher chance for detection (63.6% sensitivity, p < 0.05). CONCLUSIONS: Overall performance in predicting imminent decompensation by monitoring TI alone is limited due to its high inter-patient variability. TI stand-alone applications should be redirected towards a target population with more advanced symptoms where post-hospital observation aimed to maintain the patient's discharge status might be the most valuable approach. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier NCT00711360 (HomeCARE-II) and NCT01221649 (J-HomeCARE-II).


Asunto(s)
Cardiografía de Impedancia/instrumentación , Insuficiencia Cardíaca/fisiopatología , Anciano , Algoritmos , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Impedancia Eléctrica , Femenino , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Estudios Prospectivos , Sensibilidad y Especificidad , Volumen Sistólico
3.
Europace ; 19(3): 335-345, 2017 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-27702851

RESUMEN

The wearable cardioverter-defibrillator has been available for over a decade and now is frequently prescribed for patients deemed at high arrhythmic risk in whom the underlying pathology is potentially reversible or who are awaiting an implantable cardioverter-defibrillator. The use of the wearable cardioverter-defibrillator is included in the new 2015 ESC guidelines for the management of ventricular arrhythmias and prevention of sudden cardiac death. The present review provides insight into the current technology and an overview of this approach.


Asunto(s)
Arritmias Cardíacas/terapia , Muerte Súbita Cardíaca/prevención & control , Desfibriladores , Cardioversión Eléctrica/instrumentación , Arritmias Cardíacas/economía , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/fisiopatología , Análisis Costo-Beneficio , Desfibriladores/economía , Difusión de Innovaciones , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/economía , Cardioversión Eléctrica/mortalidad , Diseño de Equipo , Costos de la Atención en Salud , Humanos , Cooperación del Paciente , Satisfacción del Paciente , Factores de Riesgo , Resultado del Tratamiento
4.
Artículo en Inglés | MEDLINE | ID: mdl-28117536

RESUMEN

BACKGROUND: The majority of sudden cardiac death (SCD) in patients with heart failure occurs in those with mild-moderate left ventricular (LV) systolic dysfunction (LVEF 36-50%) who under current guidelines are ineligible for primary prevention implantable cardiac defibrillator (ICD) therapy. Recent data suggest that cardiac magnetic resonance (CMR) evidence of replacement fibrosis forms a substrate for malignant arrhythmia and therefore potentially identifies a subgroup at increased risk of SCD. Our hypothesis is that among patients with mild-moderate LV systolic dysfunction, a CMR-guided management strategy for ICD insertion based on the presence of scar or fibrosis is superior to a current strategy of standard care. METHODS/DESIGN: CMR GUIDE is a prospective, multicenter randomized control trial enrolling patients with mild-moderate LV systolic dysfunction and CMR evidence of fibrosis on optimal heart failure therapy. Participants will be randomized to receive either a primary prevention ICD or an implantable loop recorder (ILR). The primary endpoint is the time to SCD or hemodynamically significant ventricular arrhythmia (VF or VT) during an average 4-year follow-up. Secondary endpoints include quality of life assessed by Minnesota Living with Heart Failure Questionnaire, heart failure related hospitalizations, and a cost-utility analysis. Clinical trials.gov identifier NCT01918215. DISCUSSION: CMR GUIDE trial will add substantially to our understanding of the role of myocardial fibrosis and the risk of developing life-threatening ventricular arrhythmias. If the superiority of a CMR-guided approach over standard care is proven, it may change international clinical guidelines, with the potential to considerably increase survival in this growing patient population.


Asunto(s)
Desfibriladores Implantables , Imagen por Resonancia Magnética Intervencional/métodos , Marcapaso Artificial , Disfunción Ventricular Izquierda/terapia , Adulto , Australia , Europa (Continente) , Femenino , Humanos , Masculino , Sistema de Registros , Índice de Severidad de la Enfermedad , Adulto Joven
5.
J Cardiovasc Electrophysiol ; 27(12): 1403-1410, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27565119

RESUMEN

INTRODUCTION: Reliable detection and monitoring of atrial fibrillation (AF) is essential for accurate clinical decision making, which can now be done continuously with the introduction of implantable cardiac monitors (ICM) The DETECT AF study evaluated the performance of the Confirm DM2102 ICM (St. Jude Medical, St. Paul, MN, USA) to accurately detect and monitor AF. METHODS: Ninety patients previously implanted with the ICM and with either suspected or known paroxysmal AF were enrolled at 12 centers in Germany and The Netherlands. At least 2 weeks after ICM implant, patients wore a Holter monitor for 4 days, while the ICM monitored for AF episodes lasting at least 2 minutes. Holter monitor data was analyzed by a blinded, independent core laboratory and compared to the ICM AF detections. Patient and episode sensitivity (SE), specificity (SP), positive predictive value (PPV), and negative predictive (NPV) were calculated using standard analysis and a generalized estimation equation method where appropriate. RESULTS: A total of 79/90 subjects (61% male, 65.7 ± 9.6 years old) were included in the analysis, totaling 6,894 hours of Holter monitoring. Using a per patient analysis SE was 100%, PPV was 64.0%, SP was 85.7%, and NPV was 100%. Using a per episode analysis, SE was 94.0% and PPV was 64.0%. With an AF duration analysis, the SE was 83.9%, PPV was 97.3%, SP was 99.4% with an NPV of 98.5%. CONCLUSION: The SJM Confirm DM2102 can accurately and repeatedly detect paroxysmal AF episodes of at least 2 minutes in length.


Asunto(s)
Fibrilación Atrial/diagnóstico , Electrocardiografía Ambulatoria/instrumentación , Sistema de Conducción Cardíaco/fisiopatología , Transductores , Potenciales de Acción , Anciano , Fibrilación Atrial/fisiopatología , Diseño de Equipo , Femenino , Alemania , Frecuencia Cardíaca , Humanos , Masculino , Ensayo de Materiales , Persona de Mediana Edad , Países Bajos , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Procesamiento de Señales Asistido por Computador
6.
Curr Opin Cardiol ; 30(1): 65-73, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25469592

RESUMEN

PURPOSE OF REVIEW: To assess the current knowledge about the potential hazard from MRI in patients with devices such as pacemakers and implantable cardioverter defibrillators (ICDs). RECENT FINDINGS: Most data concern 'MRI unsafe' devices, with only a few studies on 'MRI conditional' devices. No 'MRI safe' cardiac devices are currently available. Studies on 'MRI unsafe' devices tend to be small scale and reflect the experience of individual centres; few provide long-term follow-up data. Many newer devices are approved as 'MRI conditional' based on technical simulations or postmarket surveillance studies. With adequate measures taken before performing an MRI scan, reported complication rates are generally low, but there is a nonnegligible residual risk for power-on reset and lead heating. The presence of abandoned, older leads may affect the propensity for lead heating during MRI with newer devices, including those designated 'MRI conditional'. Very little research has been carried out on the hazard from MRI scans in patients with ICDs, but registry data indicate more events with ICDs than with pacemakers. SUMMARY: The limited available data indicate a manageable but not negligible MRI-associated hazard in patients with implantable cardiac devices. Further controlled studies and large, independent registries, particularly in Europe, are needed to provide important safety information.


Asunto(s)
Desfibriladores Implantables/estadística & datos numéricos , Imagen por Resonancia Magnética/efectos adversos , Marcapaso Artificial/estadística & datos numéricos , Seguridad del Paciente , Femenino , Humanos , Masculino , Evaluación de Necesidades , Pronóstico , Medición de Riesgo
7.
BMC Cardiovasc Disord ; 15: 67, 2015 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-26162888

RESUMEN

BACKGROUND: Studies have associated obesity with better outcomes in comparison to non-obese patients after elective and emergency coronary revascularization. However, these findings might have been influenced by patient selection. Therefore we thought to look into the obesity paradox in a consecutive network STEMI population. METHODS: The database of two German myocardial infarction network registries were combined and data from a total of 890 consecutive patients admitted and treated for acute STEMI including cardiogenic shock and cardiopulmonary resuscitation according to standardized protocols were analyzed. Patients were categorized in normal weight (≤24.9 kg/m(2)), overweight (25-30 kg/m(2)) and obese (>30 kg/m(2)) according to BMI. RESULTS: Baseline clinical parameters revealed a higher comorbidity index for overweight and obese patients; 1-year follow-up comparison between varying groups revealed similar rates of all-cause death (9.1 % vs. 8.3 % vs. 6.2 %; p = 0.50), major adverse cardiac and cerebrovascular [MACCE (15.1 % vs. 13.4 % vs. 10.2 %; p = 0.53)] and target vessel revascularization in survivors [TVR (7.0 % vs. 5.0 % vs. 4.0 %; p = 0.47)] with normal weight when compared to overweight or obese patients. These results persisted after risk-adjustment for heterogeneous baseline characteristics of groups. An analysis of patients suffering from cardiogenic shock showed no impact of BMI on clinical endpoints. CONCLUSION: Our data from two network systems in Germany revealed no evidence of an "obesity paradox"in an all-comer STEMI population including patients with cardiogenic shock.


Asunto(s)
Infarto del Miocardio/mortalidad , Revascularización Miocárdica/estadística & datos numéricos , Obesidad/epidemiología , Sistema de Registros , Choque Cardiogénico/mortalidad , Accidente Cerebrovascular/epidemiología , Anciano , Índice de Masa Corporal , Causas de Muerte , Estudios de Cohortes , Comorbilidad , Femenino , Alemania , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/complicaciones , Infarto del Miocardio/cirugía , Sobrepeso/epidemiología , Intervención Coronaria Percutánea , Pronóstico , Estudios Prospectivos , Recurrencia , Factores de Riesgo , Choque Cardiogénico/etiología , Choque Cardiogénico/cirugía
8.
BMC Cardiovasc Disord ; 14: 71, 2014 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-24893930

RESUMEN

BACKGROUND: It is uncertain whether gender differences in outcome after primary percutaneous coronary intervention (PCI) are only attributable to different baseline characteristics or additional factors. METHODS: Databases of two German myocardial infarction network registries were combined with a total of 1104 consecutive patients admitted with acute ST-elevation myocardial infarction (STEMI) and treated according to standardized protocols. RESULTS: Approximately 25% of patients were females. Mean age (69 vs 61 years), incidence of diabetes (28% vs 20%), hypertension (68 vs 58%) and renal insufficiency (26% vs 19%) was significantly higher compared to males. Mean prehospital delay was numerically longer in females (227 vs 209 min) as was in hospital delay (35 vs 30 min). PCI was finally performed in 92% of females and 95% of males with comparable procedural success (95% vs 97%). Use of drug eluting stents (55% vs 68%) and application of GP 2b 3a blockers (75% vs 89%) was significantly less frequent in women. At discharge, prescription of beta blockers and lipid lowering drugs was also significantly lower in females (84% vs 90% and 71% vs 84%). Unadjusted in-hospital mortality was significantly higher in females (10% vs 5%) without attenuation after 12 months. Adjusted mortality however did not differ significantly between genders. CONCLUSION: Higher unadjusted mortality in females after primary PCI was accompanied by significant differences in baseline characteristics, interventional approach and secondary prophylaxis in spite of the same standard of care. Lower guideline adherence seems to be less gender specific but rather a manifestation of the risk-treatment paradox.


Asunto(s)
Adhesión a Directriz , Disparidades en el Estado de Salud , Disparidades en Atención de Salud , Infarto del Miocardio/terapia , Intervención Coronaria Percutánea/mortalidad , Guías de Práctica Clínica como Asunto , Pautas de la Práctica en Medicina , Antagonistas Adrenérgicos beta/uso terapéutico , Anciano , Anciano de 80 o más Años , Stents Liberadores de Fármacos , Femenino , Alemania/epidemiología , Adhesión a Directriz/normas , Disparidades en Atención de Salud/normas , Mortalidad Hospitalaria , Humanos , Hipolipemiantes/uso terapéutico , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/mortalidad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/normas , Inhibidores de Agregación Plaquetaria/uso terapéutico , Guías de Práctica Clínica como Asunto/normas , Pautas de la Práctica en Medicina/normas , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores Sexuales , Factores de Tiempo , Tiempo de Tratamiento , Resultado del Tratamiento
9.
NEJM Evid ; 3(1): EVIDoa2300235, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38320511

RESUMEN

BACKGROUND: Rivaroxaban and dabigatran were not superior to aspirin in trials of patients with embolic stroke of undetermined source (ESUS). It is unknown whether apixaban is superior to aspirin in patients with ESUS and known risk factors for cardioembolism. METHODS: We conducted a multicenter, randomized, open-label, blinded-outcome trial of apixaban (5 mg twice daily) compared with aspirin (100 mg once daily) initiated within 28 days after ESUS in patients with at least one predictive factor for atrial fibrillation or a patent foramen ovale. Cardiac monitoring was mandatory, and aspirin treatment was switched to apixaban in case of atrial fibrillation detection. The primary outcome was any new ischemic lesion on brain magnetic resonance imaging (MRI) during 12-month follow-up. Secondary outcomes included major and clinically relevant nonmajor bleeding. RESULTS: A total of 352 patients were randomly assigned to receive apixaban (178 patients) or aspirin (174 patients) at a median of 8 days after ESUS. At 12-month follow-up, MRI follow-up was available in 325 participants (92.3%). New ischemic lesions occurred in 23 of 169 (13.6%) participants in the apixaban group and in 25 of 156 (16.0%) participants in the aspirin group (adjusted odds ratio, 0.79; 95% confidence interval, 0.42 to 1.48; P=0.57). Major and clinically relevant nonmajor bleeding occurred in five and seven participants, respectively (1-year cumulative incidences, 2.9 and 4.2; hazard ratio, 0.68; 95% confidence interval, 0.22 to 2.16). Serious adverse event rates were 43.9 per 100 person-years in those given apixaban and 45.7 per 100 person-years in those given aspirin. The Apixaban for the Treatment of Embolic Stroke of Undetermined Source trial was terminated after a prespecified interim analysis as a result of futility. CONCLUSIONS: Apixaban treatment was not superior to cardiac monitoring-guided aspirin in preventing new ischemic lesions in an enriched ESUS population. (Funded by Bristol-Myers Squibb and Medtronic Europe; ClinicalTrials.gov number, NCT02427126.)


Asunto(s)
Accidente Cerebrovascular Embólico , Pirazoles , Piridonas , Accidente Cerebrovascular , Humanos , Aspirina , Método Doble Ciego , Accidente Cerebrovascular/prevención & control
10.
J Cardiovasc Electrophysiol ; 24(1): 40-6, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23131063

RESUMEN

BACKGROUND: Pulmonary vein isolation (PVI) has become the cornerstone procedure for the treatment of symptomatic drug-resistant atrial fibrillation (AF). At the present time, circumferential PVI (CPVI) using irrigated radiofrequency (RF) is the mostly used ablation technique. However, for CPVI, precise catheter navigation and excellent catheter stability is crucial thereby requiring experienced operators. Robotic navigation systems have been introduced to facilitate catheter navigation and to improve catheter stability, therefore potentially increasing procedural success and making CPVI accessible to less experienced operators. To date, no prospective randomized trial has evaluated the efficacy and safety of CPVI using RNS compared to manually performed ablation. METHODS: In this prospective international multicenter noninferiority trial, 258 patients with either paroxysmal or short-standing persistent AF will be randomized for comparison of PVI using either manual or robotic ablation. In all patients, CPVI will be performed using irrigated RF ablation in combination with a 3D mapping system. The primary endpoint of the trial is the absence of AF or atrial tachycardia without antiarrhythmic drug therapy during 12-month follow-up. Secondary endpoints will be evaluation of periprocedural complications and procedural data such as procedure time, fluoroscopy time, as well as the incidence of esophageal injury assessed by endoscopy within 48 hours after the procedure. CONCLUSION: The "Man and Machine Trial" is the first prospective international randomized controlled multicenter noninferiority trial to compare manually performed CPVI with robotically navigated CPVI, evaluating both the safety and efficacy of the 2 techniques during a 12-month follow-up period.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Robótica/métodos , Cirugía Asistida por Computador/métodos , Adulto , Anciano , Femenino , Humanos , Internacionalidad , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Proyectos de Investigación , Resultado del Tratamiento
12.
Pacing Clin Electrophysiol ; 36(2): 194-202, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23379836

RESUMEN

PURPOSE: Cavotricuspid isthmus-dependent atrial flutter (AFL) can occur in a paroxysmal or persistent pattern. The aim of this study was to identify clinical, echocardiographic, and electrophysiological risk factors independently associated with persistence of AFL. METHODS: Patients of the recently published AURUM 8 study with paroxysmal versus persistent AFL were compared with respect to clinical and echocardiographic baseline characteristics as well as procedural parameters. The AURUM 8 study is a randomized, multicenter clinical trial comparing the efficacy and safety of gold versus platinum-iridium 8-mm-tip ablation. AFL was paroxysmal in 218 patients and persistent in 210 patients. RESULTS: Univariate analysis revealed that patients with persistent AFL had higher New York Heart Association class (P = 0.002), shorter time since 1st AFL episode (median 0.18 vs 0.34, P = 0.037), a higher prevalence of previous coronary artery bypass grafting surgery (17% vs 9%, P = 0.02), left ventricular hypertrophy (17% vs 8%, P = 0.005), dyspnea during AFL (P < 0.001), mitral regurgitation (P = 0.002), tricuspid regurgitation (P = 0.049), and pulmonary hypertension (P = 0.01). Palpitations during AFL were less frequent in patients with persistent AFL (P = 0.001). Multivariate analysis revealed that age, weight, AFL diagnosis after initiation of class IC or III antiarrhythmic drugs for atrial fibrillation, history of left ventricular hypertrophy, dyspnea during AFL and mitral regurgitation on echocardiography were significant independent variables associated with persistent AFL. A history of atrial fibrillation and palpitations during AFL were independently associated with paroxysmal AFL. CONCLUSIONS: We were able to identify clinical and echocardiographic risk factors associated with persistence of typical AFL. Treatment of these risk factors can potentially not only prevent the transition from paroxysmal to persistent AFL, but maybe also the development or initiation of AFL in general.


Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Aleteo Atrial/diagnóstico , Aleteo Atrial/epidemiología , Ecocardiografía/estadística & datos numéricos , Anciano , Fibrilación Atrial/prevención & control , Aleteo Atrial/prevención & control , Enfermedad Crónica , Comorbilidad , República Checa/epidemiología , Femenino , Alemania/epidemiología , Humanos , Incidencia , Masculino , Reproducibilidad de los Resultados , Medición de Riesgo , Sensibilidad y Especificidad
13.
J Arrhythm ; 39(1): 1-9, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36733321

RESUMEN

Background: While prior Micra trials demonstrated a high implant success rate and favorable safety and efficacy results, changes in implant populations and safety over time is not well studied. The objective of this analysis was to report the performance of Micra in European and Middle Eastern patients and compare to the Micra Investigational Device Exemption (IDE) and Micra Post Approval Registry (PAR) studies. Methods: The prospective, single-arm Micra Acute Performance European and Middle Eastern (MAP EMEA) registry was designed to further study the performance of Micra in patients from EMEA. The primary endpoint was to characterize acute (30-day) major complications. Electrical performance was analyzed. The major complication rate through 12 months was compared with the IDE and PAR studies. Results: The MAP EMEA cohort (n = 928 patients) had an implant success rate of 99.9% and were followed for an average of 9.7 ± 6.5 months. Compared to prior studies, MAP EMEA patients were more likely to have undergone dialysis and have a condition which precluded the use of a transvenous pacemaker (p < .001). Within 30 days of implantation, the MAP EMEA cohort had a major complication rate of 2.59%. Mean pacing thresholds were low and stable through 12 months (0.61 ± 0.40 V at 0.24 ms at implant and 12 months). Through 12 months post-implantation, the major complication rate for MAP EMEA was not significantly different from IDE (p = .56) or PAR (p = .79). Conclusion: Despite patient differences over time, the Micra leadless pacemaker was implanted with a high success rate and low complication rate, in-line with prior reports.

14.
Heart Rhythm ; 20(4): 501-509, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36509321

RESUMEN

BACKGROUND: Because of its antiarrhythmic potency and due to the lack of alternatives, amiodarone is often used for antiarrhythmic therapy in patients with implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy-defibrillator systems. To date, robust data on the safety and clinical benefit of amiodarone therapy in these patients are missing. OBJECTIVE: The purpose of this study was to assess the periprocedural and postprocedural outcomes of combined therapy with beta-blockers plus amiodarone compared to treatment with single beta-blockers in the "real-life" cohort of ICD recipients of the German DEVICE registry. METHODS: A total of 4499 patients who underwent ICD implantation, revision, or upgrade in 49 centers participating in the German DEVICE registry were enrolled from March 2007 to February 2014. RESULTS: Amiodarone had no significant effect on the success of defibrillation testing. Early implantation-associated complications were similar between the groups. However, 1-year overall mortality was significantly higher in the beta-blocker plus amiodarone cohort (adjusted hazard ratio 2.09; P <.001). Interestingly, among the surviving patients, amiodarone was not associated with a significantly reduced risk of ICD discharges or syncopal events. Furthermore, the occurrence of ventricular tachycardia (VT) storm or incessant VTs and the number of patients scheduled for intracardiac ablation did not differ among both groups, whereas the rate of rehospitalization was lower in the cohort with only beta-blockers. CONCLUSIONS: Although amiodarone has no adverse effect on the success of defibrillation testing, our data suggest an increased all-cause mortality under amiodarone therapy, especially in the subgroups of patients with sinus rhythm or severely reduced left ventricular function. In surviving patients, rates of arrhythmic events were comparable.


Asunto(s)
Amiodarona , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Amiodarona/uso terapéutico , Desfibriladores Implantables/efectos adversos , Terapia de Resincronización Cardíaca/efectos adversos , Antiarrítmicos , Antagonistas Adrenérgicos beta/uso terapéutico , Sistema de Registros , Taquicardia Ventricular/terapia
15.
Clin Res Cardiol ; 2023 Nov 03.
Artículo en Inglés | MEDLINE | ID: mdl-37921923

RESUMEN

BACKGROUND AND OBJECTIVES: Long-term oral anticoagulation (OAC) following successful catheter ablation of atrial fibrillation (AF) remains controversial. Prospective data are missing. The ODIn-AF study aimed to evaluate the effect of OAC on the incidence of silent cerebral embolic events and clinically relevant cardioembolic events in patients at intermediate to high risk for embolic events, free from AF after pulmonary vein isolation (PVI). METHODS: This prospective, randomized, multicenter, open-label, blinded endpoint interventional trial enrolled patients who were scheduled for PVI to treat paroxysmal or persistent AF. Six months after PVI, AF-free patients were randomized to receive either continued OAC with dabigatran or no OAC. The primary endpoint was the incidence of new silent micro- and macro-embolic lesions detected on brain MRI at 12 months of follow-up compared to baseline. Safety analysis included bleedings, clinically evident cardioembolic, and serious adverse events (SAE). RESULTS: Between 2015 and 2021, 200 patients were randomized into 2 study arms (on OAC: n = 99, off OAC: n = 101). There was no significant difference in the occurrence of new cerebral microlesions between the on OAC and off OAC arm [2 (2%) versus 0 (0%); P = 0.1517] after 12 months. MRI showed no new macro-embolic lesion, no clinical apparent strokes were present in both groups. SAE were more frequent in the OAC arm [on OAC n = 34 (31.8%), off OAC n = 18 (19.4%); P = 0.0460]; bleedings did not differ. CONCLUSION: Discontinuation of OAC after successful PVI was not found to be associated with an elevated risk of cerebral embolic events compared with continued OAC after a follow-up of 12 months.

16.
J Cardiovasc Electrophysiol ; 23(5): 479-85, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22458432

RESUMEN

INTRODUCTION: The recently proposed "maximum voltage-guided" (MVG) technique for radiofrequency catheter ablation of atrial flutter targets high-voltage electrograms along cavotricuspid isthmus (CTI) to ablate the functionally important anatomic muscle bundles alone, without drawing a complete anatomic line across the CTI. This innovative approach may shorten ablation time and procedure duration. METHODS AND RESULTS: Within the multicenter AURUM 8 study, which compared 8-mm gold- and Pt-Ir-tip catheters in atrial flutter ablation, we made a post hoc comparison of procedural data from 72 patients treated with MVG technique with data from 281 patients undergoing anatomic CTI ablation (unmatched) and with data from 72 patients selected from among those 281 patients such that they were matched with the MVG group with respect to selected baseline parameters and catheter type (matched). The MVG technique markedly reduced (P < 0.001) ablation time (mean 6.9 minutes vs 10.9/9.7 minutes [unmatched/matched]), number of lesions (8.3 vs 13.7/12.9), fluoroscopy time (9.5 minutes vs 20.6/17.9 minutes), procedure duration (59 minutes vs 93/86 minutes), and energy delivered (19 kJ vs 34/30 kJ) compared with anatomic CTI ablation. The incidence of charring was higher for MVG than for anatomic ablation technique (31.9% vs 18.5/15.3%, P < 0.05), where Pt-Ir tip catheters were 6-fold more susceptible to charring than gold-tip catheters (P < 0.001), likely because of a lower thermal conductivity of the Pt-Ir material. The acute success rate was slightly better for MVG than for anatomic ablation technique (97.2% vs 92.2/91.7%, P = n.s.). CONCLUSION: Major procedural parameters are remarkably improved with MVG technique. Gold-tip catheters are substantially less susceptible to charring and may therefore be preferred over Pt-Ir-tip catheters for MVG ablation technique.


Asunto(s)
Aleteo Atrial/cirugía , Ablación por Catéter/métodos , Adulto , Anciano , Aleteo Atrial/diagnóstico , Aleteo Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Catéteres , Distribución de Chi-Cuadrado , Técnicas Electrofisiológicas Cardíacas , Diseño de Equipo , Femenino , Alemania , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/prevención & control , Valor Predictivo de las Pruebas , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
17.
Europace ; 14(5): 631-7, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22237585

RESUMEN

Magnetic resonance imaging (MRI) is the imaging modality of choice in many clinical situations, and its use is likely to grow due to expanding indications and an ageing population. Many patients with implantable devices are denied MRI except in cases of urgent need, and when scans must be performed they are complicated by the need for burdensome and costly personnel and monitoring requirements that have the net effect of restricting access to scans. Several small studies, enrolling a total of 344 patients, suggest that some patients with conventional systems may undergo MR examinations without clinically overt adverse events. However, a number of potential interactions exist between implantable cardiac devices and the static and gradient magnetic fields and modulated radio frequency (RF) fields generated during MR scans; nearly all studies have reported pacing capture threshold changes, troponin elevations, ectopy, unpredictable reed switch behaviour, and other 'subclinical' issues with pacemakers and implantable cardioverter-defibrillators (ICDs) in patients who have undergone MRI. Attention has turned to devices that are specifically designed to be safe in the MRI environment. A clinical study of one such device documented its ability to be exposed to MRI in a 1.5 T scanner without adverse impact on patient outcomes or pacemaker system function. Such new technologies may enable scanning of pacemaker and ICD patients with reduced concerns regarding the short- and long-term effects of MRI. As importantly, these devices may increase the number of centres that are able to safely perform MRI and, thus, expand access to scans for patients with these devices.


Asunto(s)
Arritmias Cardíacas/terapia , Desfibriladores Implantables , Imagen por Resonancia Magnética/tendencias , Marcapaso Artificial , Guías de Práctica Clínica como Asunto , Desfibriladores Implantables/normas , Humanos , Campos Magnéticos , Imagen por Resonancia Magnética/efectos adversos , Imagen por Resonancia Magnética/normas , Marcapaso Artificial/normas
19.
Europace ; 14(12): 1793-8, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22791298

RESUMEN

AIMS: Cardiogoniometry (CGM) is a spatio-temporal five-lead resting electrocardiographic method utilizing automated analysis. The purpose of this study was to determine CGM's and electrocardiography (ECG)'s accuracy for detecting myocardial ischaemia and/or lesions in comparison with perfusion cardiac magnetic resonance imaging (CMRI) and late gadolinium enhancement (LGE). METHODS AND RESULTS: Forty (n= 40) patients with suspected or known stable coronary artery disease were examined by CGM and resting ECG directly prior to CMRI including adenosine stress perfusion (ASP) and LGE. The investigators visually reading the CMRI were blinded to the CGM and ECG results. Half of the patients (n= 20) had a normal CMRI while the other half presented with either abnormal ASP and/or detectable LGE. Cardiogoniometry yielded an accuracy of 83% (sensitivity 70%) and ECG of 63% (sensitivity 35%) compared with CMRI. CONCLUSIONS: In this pilot study CGM compares more favourably than ECG with the detection of ischaemia and/or structural myocardial lesions on CMRI.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico , Electrocardiografía/métodos , Compuestos Heterocíclicos , Angiografía por Resonancia Magnética/métodos , Isquemia Miocárdica/diagnóstico , Imagen de Perfusión Miocárdica/métodos , Compuestos Organometálicos , Adenosina , Anciano , Medios de Contraste , Enfermedad de la Arteria Coronaria/complicaciones , Prueba de Esfuerzo , Femenino , Gadolinio , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/etiología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Vasodilatadores
20.
Europace ; 14(3): 365-72, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21993431

RESUMEN

AIMS: Cardiac resynchronization therapy (CRT) is sometimes complicated by elevated pacing thresholds and phrenic nerve stimulation (PNS), both of which may require that the coronary sinus lead be repositioned. The purpose of this study was to evaluate the performance of a novel quadripolar electrode lead and cardiac resynchronization therapy-defibrillator (CRT-D) device that enables electrical repositioning, potentially obviating a lead reposition procedure. METHODS AND RESULTS: Patients indicated for CRT were enrolled and received a quadripolar electrode lead and CRT-D device (Quartetmodel 1458Q and Promote Q; St Jude Medical, Sylmar, CA, USA). Electrical data, and the presence of PNS during pacing from each left ventricular (LV) configuration, were documented at pre-hospital discharge and at 1 month. Seventy-five patients were enrolled and 71 were successfully implanted with a Quartetlead. Electrical measurements were stable over the follow-up period. Ninety-seven per cent (64 of 66) of patients had one or more programmable configurations with a threshold < 2.5 V and no PNS vs. 86% (57 of 66) if only conventional bipolar configurations were considered. Physicians were able to use the increased programming options to manage threshold changes and PNS. CONCLUSION: The new quadripolar electrode LV lead provides more programming options to address common problems faced when managing CRT patients. Electrical measurements from new vectors are comparable with conventional configurations. Furthermore, 11% of patients in the study suffered PNS on all conventional bipolar vectors.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Electrodos Implantados , Insuficiencia Cardíaca/terapia , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/terapia , Nervio Frénico/fisiopatología , Resultado del Tratamiento , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA