Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Ann Rheum Dis ; 79(11): 1485-1491, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32719042

RESUMEN

OBJECTIVES: To date, there is no valuable tool to assess fibrotic disease activity in humans in vivo in a non-invasive way. This study aims to uncouple inflammatory from fibrotic disease activity in fibroinflammatory diseases such as IgG4-related disease. METHODS: In this cross-sectional clinical study, 27 patients with inflammatory, fibrotic and overlapping manifestations of IgG4-related disease underwent positron emission tomography (PET) scanning with tracers specific for fibroblast activation protein (FAP; 68Ga-FAP inhibitor (FAPI)-04), 18F-fluorodeoxyglucose (FDG), MRI and histopathological assessment. In a longitudinal approach, 18F-FDG and 68Ga-FAPI-04 PET/CT data were evaluated before and after immunosuppressive treatment and correlated to clinical and MRI data. RESULTS: Using combination of 68Ga-FAPI-04 and 18F-FDG-PET, we demonstrate that non-invasive functional tracking of IgG4-related disease evolution from inflammatory towards a fibrotic outcome becomes feasible. 18F-FDG-PET positive lesions showed dense lymphoplasmacytic infiltration of IgG4+ cells in histology, while 68Ga-FAPI-04 PET positive lesions showed abundant activated fibroblasts expressing FAP according to results from RNA-sequencing of activated fibroblasts. The responsiveness of fibrotic lesions to anti-inflammatory treatment was far less pronounced than that of inflammatory lesions. CONCLUSION: FAP-specific PET/CT permits the discrimination between inflammatory and fibrotic activity in IgG4-related disease. This finding may profoundly change the management of certain forms of immune-mediated disease, such as IgG4-related disease, as subtypes dominated by fibrosis may require different approaches to control disease progression, for example, specific antifibrotic agents rather than broad spectrum anti-inflammatory treatments such as glucocorticoids.


Asunto(s)
Fibrosis/diagnóstico por imagen , Enfermedad Relacionada con Inmunoglobulina G4/diagnóstico por imagen , Enfermedad Relacionada con Inmunoglobulina G4/patología , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Adulto , Estudios Transversales , Endopeptidasas , Femenino , Fibroblastos/patología , Fibrosis/etiología , Fluorodesoxiglucosa F18 , Gelatinasas/análisis , Humanos , Interpretación de Imagen Asistida por Computador , Inflamación/diagnóstico por imagen , Inflamación/etiología , Inflamación/patología , Masculino , Proteínas de la Membrana/análisis , Persona de Mediana Edad , Quinolinas , Radiofármacos , Serina Endopeptidasas/análisis
2.
Eur J Nucl Med Mol Imaging ; 43(11): 1962-70, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27207281

RESUMEN

PURPOSE: Positron emission tomography (PET) agents targeting the prostate-specific membrane antigen (PSMA) are currently under broad clinical and scientific investigation. (68)Ga-PSMA HBED-CC constitutes the first (68)Ga-labelled PSMA-inhibitor and has evolved as a promising agent for imaging PSMA expression in vivo. The aim of this study was to evaluate the whole-body distribution and radiation dosimetry of this new probe. METHODS: Five patients with a history or high suspicion of prostate cancer were injected intravenously with a mean of 139.8 ± 13.7 MBq of (68)Ga-PSMA HBED-CC (range 120-158 MBq). Four static skull to mid-thigh scans using a whole-body fully integrated PET/MR-system were performed 10 min, 60 min, 130 min, and 175 min after the tracer injection. Time-dependent changes of the injected activity per organ were determined. Mean organ-absorbed doses and effective doses (ED) were calculated using OLINDA/EXM. RESULTS: Injection of a standard activity of 150 MBq (68)Ga-PSMA HBED-CC resulted in a median effective dose of 2.37 mSv (Range 1.08E-02 - 2.46E-02 mSv/MBq). The urinary bladder wall (median absorbed dose 1.64E-01 mGv/MBq; range 8.76E-02 - 2.91E-01 mGv/MBq) was the critical organ, followed by the kidneys (median absorbed dose 1.21E-01 mGv/MBq; range 7.16E-02 - 1.75E-01), spleen (median absorbed dose 4.13E-02 mGv/MBq; range 1.57E-02 - 7.32E-02 mGv/MBq) and liver (median absorbed dose 2.07E-02 mGv/MBq; range 1.80E-02 - 2.57E-02 mGv/MBq). No drug-related pharmacological effects occurred. CONCLUSION: The use of (68)Ga-PSMA HBED-CC results in a relatively low radiation exposure, delivering organ doses that are comparable to those of other (68)Ga-labelled PSMA-inhibitors used for PET-imaging. Total effective dose is lower than for other PET-agents used for prostate cancer imaging (e.g. (11)C- and (18)F-Choline).


Asunto(s)
Ácido Edético/análogos & derivados , Glutamato Carboxipeptidasa II/farmacocinética , Tomografía de Emisión de Positrones/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/metabolismo , Exposición a la Radiación/análisis , Absorción de Radiación , Anciano , Antígenos de Superficie , Ácido Edético/farmacocinética , Humanos , Masculino , Persona de Mediana Edad , Técnicas de Sonda Molecular , Especificidad de Órganos , Dosis de Radiación , Radiofármacos/farmacocinética , Distribución Tisular , Recuento Corporal Total
3.
Lancet Rheumatol ; 3(3): e185-e194, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38279381

RESUMEN

BACKGROUND: Interstitial lung disease (ILD) is the most common cause of death in systemic sclerosis. To date, the progression of systemic sclerosis-associated ILD is judged by the accrual of lung damage on CT and pulmonary function tests. However, diagnostic tools to assess disease activity are not available. Here, we tested the hypothesis that quantification of fibroblast activation by PET-CT using a 68Ga-labelled selective inhibitor of prolyl endopeptidase FAP (68Ga-FAPI-04) would correlate with ILD activity and disease progression in patients with systemic sclerosis-associated ILD. METHODS: Between Sept 10, 2018, and April 8, 2020, 21 patients with systemic sclerosis-associated ILD confirmed by high-resolution CT (HRCT) within 12 months of inclusion and with onset of systemic sclerosis-associated ILD within 5 years or signs of progressive ILD and 21 controls without ILD were consecutively enrolled. All participants underwent 68Ga-FAPI-04 PET-CT imaging and standard-of-care procedures, including HRCT and pulmonary function tests at baseline. Patients with systemic sclerosis-associated ILD were followed for 6 months with HRCT and pulmonary function tests. We compared baseline 68Ga-FAPI-04 PET-CT uptake with standard diagnostic tools and predictors of ILD progression. The association of 68Ga-FAPI-04 uptake with changes in forced vital capacity was analysed using mixed-effects models. Follow-up 68Ga-FAPI-04 PET-CT scans were obtained in a subset of patients treated with nintedanib (follow-up between 6-10 months) to assess change over time. FINDINGS: 68Ga-FAPI-04 accumulated in fibrotic areas of the lungs in patients with systemic sclerosis-associated ILD compared with controls, with a median standardised uptake value (SUV) mean over the whole lung of 0·80 (IQR 0·60-2·10) in the systemic sclerosis-ILD group and 0·50 (0·40-0·50) in the control group (p<0·0001) and a mean whole lung maximal SUV of 4·40 (range 3·05-5·20) in the systemic sclerosis-ILD group compared with 0·70 (0·65-0·70) in the control group (p<0·0001). Whole-lung FAPI metabolic active volume (wlFAPI-MAV) and whole-lung total lesion FAPI (wlTL-FAPI) were not measurable in control participants, because no 68Ga-FAPI-04 uptake above background level was observed. In the systemic sclerosis-ILD group the median wlFAPI-MAV was 254·00 cm3 (IQR 163·40-442·30), and the median wlTL-FAPI was 183·60 cm3 (98·04-960·70). 68Ga-FAPI-04 uptake was higher in patients with extensive disease, with previous ILD progression, or high EUSTAR activity scores than in those with with limited disease, previously stable ILD, or low EUSTAR activity scores. Increased 68Ga-FAPI-04 uptake at baseline was associated with progression of ILD independently of extent of involvement on HRCT scan and the forced vital capacity at baseline. In consecutive 68Ga-FAPI-04 PET-CTs, changes in 68Ga-FAPI-04 uptake was concordant with the observed response to the fibroblast-targeting antifibrotic drug nintedanib. INTERPRETATION: Our study presents the first in-human evidence that fibroblast activation correlates with fibrotic activity and disease progression in the lungs of patients with systemic sclerosis-associated ILD and that 68Ga-FAPI-04 PET-CT might improve risk assessment of systemic sclerosis-associated ILD. FUNDING: German Research Foundation, Erlangen Anschubs-und Nachwuchsfinanzierung, Interdisziplinäres Zentrum für Klinische Forschung Erlangen, Bundesministerium für Bildung und Forschung, Deutsche Stiftung Systemische Sklerose, Wilhelm-Sander-Foundation, Else-Kröner-Fresenius-Foundation, European Research Council, Ernst-Jung-Foundation, and Clinician Scientist Program Erlangen.

4.
Phys Med ; 56: 74-80, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30527092

RESUMEN

PURPOSE: The objective of this study was to evaluate the image degrading factors in quantitative 177Lu SPECT imaging when using both main gamma photopeak energies. METHODS: Phantom measurements with two different vials containing various calibrated activities in air or water were performed to derive a mean calibration factor (CF) for large and small volumes of interest (VOIs). In addition, Monte Carlo simulations were utilized to investigate the effect of scatter energy window width, scatter correction method, such as effective scatter source estimation (ESSE) and triple energy window (TEW), and attenuation map on the quantification of 177Lu. RESULTS: The measured mean CF using large and small VOIs in water was 4.50 ±â€¯0.80 and 4.80 ±â€¯0.72 cps MBq-1, respectively. Simulations showed a reference CF of 3.3 cps MBq-1 for the water-filled phantom considering all photons excluding scattered events. By using the attenuation map generated for 190 keV photons, the calculated CFs for 113 keV and 208 keV are 10% lower than by using the weighted mean energy of 175 keV for 177Lu. The calculated CF using the TEW correction was 17% higher than using the ESSE method for a water-filled phantom. However, our findings showed that an appropriate scatter window combination can reduce this difference between TEW and ESSE methods. CONCLUSIONS: The present work implies that choosing a suitable width of scatter energy windows can reduce uncertainties in radioactivity quantification. It is suggested to generate the attenuation map at 113 keV and 208 keV, separately. Furthermore, using small VOIs is suggested in CF calculation.


Asunto(s)
Lutecio , Radioisótopos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/métodos , Aire , Calibración , Simulación por Computador , Método de Montecarlo , Fantasmas de Imagen , Dispersión de Radiación , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/instrumentación , Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA