Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Ann Thorac Surg ; 101(6): 2373-5, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27211949

RESUMEN

Hemoglobin SC (HbSC) disease is a hemoglobinopathy that may produce sickling under conditions of hypoxemia, dehydration, and acidosis. We present a case of HbSC disease and tricuspid atresia, type IB. We describe management by cardiopulmonary bypass CPB using exchange transfusion at initiation of bypass and fractionation of collected blood, allowing platelet and plasma apheresis, as an option for patients unable to undergo this procedure off pump.


Asunto(s)
Puente Cardiopulmonar/métodos , Enfermedad de la Hemoglobina SC/complicaciones , Atresia Tricúspide/cirugía , Anticoagulantes/administración & dosificación , Transfusión de Sangre Autóloga , Preescolar , Cianosis , Recambio Total de Sangre , Femenino , Procedimiento de Fontan , Paro Cardíaco Inducido , Heparina/administración & dosificación , Humanos , Hipotermia Inducida , Cuidados Paliativos , Plasmaféresis , Plaquetoferesis , Cuidados Preoperatorios , Atresia Tricúspide/complicaciones
2.
Perfusion ; 21(6): 391-4, 2006 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17312864

RESUMEN

Two patients are presented with right atrial tumors, who were considered to be at risk for tumor thrombus migration down the venous line into the cardiopulmonary bypass (CPB) circuit during surgical excision, which may lead to compromised or interrupted venous drainage. An arterial line filter was placed in the venous line to capture any material that might become dislodged and embolize into the circuit. Vacuum-assisted venous drainage, at approximately -50 mmHg, was used to overcome any resistance caused by the filter in the venous line. In one case, tumor thrombus obstructed the filter, requiring the use of the bypass line around the filter, so venous return could be maintained. In both cases, thrombus was found in the filter. The first case was a 44-year-old female (81 kg, 137 cm, body surface area (BSA) 1.66 m2) who presented with a metastatic pheochromocytoma with associated thrombus arising from the left adrenal gland and extending into the inferior vena cava (IVC) and right atrium. The second case was a 37-year-old male (95 kg, 178 cm, BSA 2.17 m2), who presented with a very large angiosarcoma tumor involving almost the entire right atrium. We have shown that venous line filtration with vacuum-assisted venous drainage can be performed safely, and should be considered in cases where there is tumor thrombus in the vena cava or right atrium, which may threaten venous return.


Asunto(s)
Neoplasias Cardíacas/cirugía , Hemangiosarcoma/cirugía , Complicaciones Intraoperatorias/prevención & control , Células Neoplásicas Circulantes , Filtros de Vena Cava , Adulto , Puente Cardiopulmonar/instrumentación , Femenino , Atrios Cardíacos/cirugía , Neoplasias Cardíacas/patología , Hemangiosarcoma/patología , Humanos , Imagen por Resonancia Magnética , Masculino , Vena Cava Inferior
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA