Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Eur J Pediatr ; 182(10): 4759-4766, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37792091

RESUMEN

Pediatric septic shock is defined as progressive multi-organ dysfunction and cardiovascular dysfunction accompanying sepsis. Studies showing myocardial dysfunction associated with pediatric septic shock are very limited. The aim of this study was to evaluate the relationship between myocardial functions calculated by echocardiography, disease severity, and clinical outcomes in children with septic shock. This observational prospective study was conducted in a pediatric intensive care at a university-affiliated tertiary hospital. The patients diagnosed with septic shock between January 2021 and February 2022 were included in the study. The study was conducted with 56 patients. The rate of myocardial dysfunction (systolic and/or diastolic dysfunction) was 50%. Of these, 39.3% (n = 22) had systolic dysfunction, 17.9% (n = 10) had diastolic dysfunction, and 8.9% (n = 5) had both systolic and diastolic dysfunction. PRISM III score (p = 0.004), VIS (p < 0.001), lactate (p = 0.002), CK-MB (p = 0.023), troponin (p = 0.038), EF (p = 0.004) EF z-score (p = 0.003), MAPSE z-score (p = 0.049), TAPSE (p = 0.010), TAPSE z-score (p = 0.003), and mitral valve E/e ´z-score (p = 0.028) were statistically significant difference with mortality. No significant difference was found for mortality with MAPSE (p = 0.090), mitral valve E/A (p = 0.624), and mitral valve E/A z-score (p = 0.327). EF z-score was found to be associated with 30-day mortality (OR = 0,681, 95% CI 0,480 to 0.991, p = 0,045). We found the TAPSE z-score to be the most significant parameter with 30-day mortality (OR = 0,690, 95% CI 0,489 to 0.998, p = 0,032).  Conclusion: We found left ventricular dysfunction associated factor with mortality. TAPSE showing right ventricular dysfunction was found to be the independent risk factor most associated with mortality. What is Known: • Studies showing myocardial dysfunction associated with pediatric septic shock are limited. • Little is known about the use of echocardiography in pediatric septic shock, and there are no specific guidelines for treatment and follow-up in pediatric patients. What is New: • Characteristics, echocardiographic measurements, and outcomes were comprehensively assessed in children with septic shock. • As a result of our analysis, we found that TAPSE, which is easily measured at the bedside, is the most critical parameter in relation to mortality. • We offer recommendations for its use in the follow-up of children with septic shock.


Asunto(s)
Sepsis , Choque Séptico , Disfunción Ventricular Izquierda , Niño , Humanos , Choque Séptico/complicaciones , Estudios Prospectivos , Sepsis/complicaciones , Ecocardiografía
2.
Acta Paediatr ; 2022 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-35818128

RESUMEN

AIM: This study was aimed at characterizing the prevalence, management, and outcomes of pediatric severe sepsis and septic shock in tertiary pediatric intensive care units (PICUs) in Turkey. METHODS: A point prevalence study was conducted on five days over the course of one year in 29 PICUs in Turkey. Outcomes included severe sepsis and septic shock point prevalence, therapies used, duration of PICU stay, and mortality at day 28. RESULTS: Of the 1757 children who were admitted to the PICU during the study period, 141 (8.0%) children met the consensus criteria for severe sepsis and 23 (1.3%) children met the criteria for septic shock. Pediatric severe sepsis and septic shock accounted for 8% and 1.3% of all PICU admissions, respectively. The median age of the patients was 2.6 years (interquartile range (IQR), 0.7-8.6 years). Enteral nutrition (79.3%) was preferred compared to parenteral nutrition (31.1%) for the first 3 days after PICU admission. A total of 39 patients died while in the PICU, for a 23.8% mortality rate, which did not vary by age. CONCLUSION: The mortality rate was similar to that in other studies. Hematologic-immunologic comorbidity, parenteral nutrition and the use of vasoactive drugs were independently associated with mortality.

3.
Klin Padiatr ; 233(5): 231-236, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33601431

RESUMEN

BACKGROUND: Cystic fibrosis (CF) is a multisystemic disease that prevalently involves the lungs. Hypoxemia occurs due to the existing of progressive damage to the pulmonary parenchyma and pulmonary vessels. The condition may cause systolic and diastolic dysfunction to the right ventricle due to the effects of high pulmonary artery systolic pressure (PASP). The study aimed to determine echocardiographic alterations in PASP, right ventricle (RV) anatomy, and functions in mild CF children. MATERIALS AND METHODS: RV anatomy, systolic, and diastolic functions were evaluated with conventional echocardiographic measurements. Estimated PASP was used measured with new echocardiographic modalities, including pulmonary artery acceleration time (PAAT), right ventricular ejection time (RVET), and their ratio (PAAT/RVET). The obtained echocardiographic data were statistically compared between the patient group and the control group. RESULTS: The study consisted of 30 pediatric patients with mild CF and 30 healthy children with similar demographics. In patient group, conventional parameters disclosed differences in RV anatomy, both systolic and diastolic functions of RV compared with the healthy group. We did not compare the patient group with published standard data because of the wide range variability. However, new echocardiographic parameters showed notable increase in pulmonary artery pressure compared with values of control group and published standard data (p<0.001). CONCLUSION: Elevated PASP, RV failure, and Cor pulmonale usually begin early in children with mild CF. In addition to routine echocardiographic measurements to evaluate RV, we recommend the use of new echocardiographic modalities for routine examinations and in the follow up of children with mild CF.


Asunto(s)
Fibrosis Quística , Hipertensión Pulmonar , Disfunción Ventricular Derecha , Niño , Fibrosis Quística/diagnóstico por imagen , Ecocardiografía , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Estudios Prospectivos , Arteria Pulmonar/diagnóstico por imagen , Disfunción Ventricular Derecha/diagnóstico por imagen
4.
Psychiatr Danub ; 33(Suppl 13): 364-371, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35150510

RESUMEN

BACKGROUND: Coronavirus disease 2019 (COVID-19) may affect the mental status of health care professionals. The purpose of our study is to evaluate the mental health effects of the COVID-19 epidemic on health care professionals in the pediatric intensive care units (PICUs). SUBJECTS AND METHODS: Our study was conducted prospectively between 01.04.20 and 10.04.20. The created questionnaire was applied to health care professionals through online platforms. Thus it was involved in 5 different institutions that participated from different regions of Turkey. With the questionnaire, we applied; the participants' age, gender, the general status of contamination and the level of COVID-19 knowledge were questioned. Besides; Beck Anxiety Scale, Acute Stress Scale (PCL-5), STAI-1 and STAI-2 (State and Trait Anxiety Inventory 1-2) scales were used to determine the anxiety levels. RESULTS: A survey of 210 participants, 86 (41%) doctors, 124 (59%) nurses, were included in our study. When we evaluate the Beck anxiety levels, the majority of the participants (44%) were normal, while about one third had mild anxiety. When we evaluated the acute stress scale, all participants had a certain amount of stress levels. The majority (80 people each (38%)) experienced mild and moderate acute stress. Being female and having chronic disease poses a high risk for anxiety (OR, 0.330; 95% CI, 0.087-1.250, p<0.05 and OR, 0.246; 95% CI, 0.068-1.116, p<0.05), preoccupation (OR, 0.603; 95% CI 0.261-1.395, p<0.05 and OR, 0.433; 95% CI, 0.122-1.538, p<0.05) and acute stress (OR, 0.294; 95% CI, 0.033-2.649, p<0.05 and OR, 0.317; 95% CI 0.060-1.679, p<0.05). Professional definition, marital status and having a child do not pose any risk factors. CONCLUSION: Our study has shown that the COVID-19 outbreak affects the mental status of health care professionals working at PICU at various levels.


Asunto(s)
COVID-19 , Ansiedad , Niño , Depresión , Brotes de Enfermedades , Femenino , Personal de Salud , Humanos , Unidades de Cuidado Intensivo Pediátrico , SARS-CoV-2 , Encuestas y Cuestionarios
5.
Pediatr Crit Care Med ; 21(5): e253-e258, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32168304

RESUMEN

OBJECTIVES: To investigate conventional mechanical ventilation weaning characteristics of patients requiring conventional mechanical ventilation support for greater than 48 hours within the PICU. DESIGN: The prospective observational multicenter cohort study was conducted at 15 hospitals. Data were being collected from November 2013 to June 2014, with two designated researchers from each center responsible for follow-up and data entry. SETTING: Fifteen tertiary PICUs in Turkey. PATIENTS: Patients between 1 month and 18 years old requiring conventional mechanical ventilation for greater than 48 hours were included. A single-center was not permitted to surpass 20% of the total sample size. Patients with no plans for conventional mechanical ventilation weaning were excluded. INTERVENTIONS: Conventional mechanical ventilation MEASUREMENTS AND MAIN RESULTS:: Pertinent variables included PICU and patient demographics, including clinical data, chronic diseases, comorbid conditions, and reasons for intubation. Conventional mechanical ventilation mode and weaning data were characterized by daily ventilator parameters and blood gases. Patients were monitored until hospital discharge. Of the 410 recruited patients, 320 were included for analyses. A diagnosis of sepsis requiring intubation and high initial peak inspiratory pressures correlated with a longer weaning period (mean, 3.65 vs 1.05-2.17 d; p < 0.001). Conversely, age, admission Pediatric Risk of Mortality III scores, days of conventional mechanical ventilation before weaning, ventilator mode, and chronic disease were not related to weaning duration. CONCLUSIONS: Pediatric patients requiring conventional mechanical ventilation with a diagnosis of sepsis and high initial peak inspiratory pressures may require longer conventional mechanical ventilation weaning prior to extubation. Causative factors and optimal weaning for this cohort needs further consideration.


Asunto(s)
Respiración Artificial , Desconexión del Ventilador , Niño , Estudios de Cohortes , Humanos , Lactante , Unidades de Cuidado Intensivo Pediátrico , Estudios Prospectivos , Encuestas y Cuestionarios , Turquía
6.
Pediatr Emerg Care ; 34(9): 661-664, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27668917

RESUMEN

OBJECTIVE: An electrical injury (EI) is an emergency that causes high morbidity and mortality each year. The aim of this study was to define the epidemiological, clinical, and laboratory factors that might predict severe patients and cardiac arrest in pediatric EI cases. METHODS: All of the patients' medical files were reviewed retrospectively through a 2-year period for the demographic, clinical, and laboratory findings. The patients were classified into the severe injury group or the mild injury group. The SPSS (Chicago, Ill) software was used to analyze the data. RESULTS: Among the 38 patients, 18 patients (47.4%) were in the mild group, and 20 patients (52.6%) were in the severe group. Low-voltage injuries were observed in 35 (92.1%) of the patients. Most of the severe patients were injured with low voltage (75%) and in household settings (85%). Plug and sockets were the most observed source of the injuries in all of the patients, whereas water-related injuries were most prevalent in the severe group. The source of injury was different in the mild and severe groups (P = 0.009). In the severe group, 13 patients (34.2%) were resuscitated after cardiopulmonary arrest. In the multivariate analysis of the demographic data, the most predictive parameters for cardiac arrest and the clinical severity in EIs are the factors of electrical cables and water. CONCLUSIONS: Electrical injuries are a significant concern in the pediatric population. Our results showed that low voltage and household electricity could cause morbidity and mortality.


Asunto(s)
Traumatismos por Electricidad/epidemiología , Paro Cardíaco/epidemiología , Adolescente , Reanimación Cardiopulmonar/estadística & datos numéricos , Niño , Preescolar , Traumatismos por Electricidad/complicaciones , Femenino , Paro Cardíaco/etiología , Humanos , Lactante , Masculino , Estudios Retrospectivos , Factores de Riesgo , Turquía/epidemiología
7.
J Obstet Gynaecol ; 38(1): 16-21, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28631496

RESUMEN

The aim of this study is to detect preeclampsia-related cardiac dysfunction within 24-48 hours of delivery in newborns born from preeclamptic mothers. Forty newborns from mildly preeclamptic mothers formed the study group and the control group was formed by 40 healthy newborns. Cardiac function for the groups were evaluated using conventional echocardiography and myocardial performance index (MPI) within the first 24-48 hours of their lifetime and the results of both groups were compared. A significant difference between the groups was observed especially in the PW Doppler MPI measurements (the left ventricle MPI 0.37 ± 0.09 and 0.26 ± 0.11, p < .001; the right ventricle MPI 0.29 ± 0.08 and 0.26 ± 0.07, p < .035) for the control group and the study group. Elongation in the left and right ventricle MPI was detected to be more significant in terms of comparing systolic and diastolic functions to determine preeclampsia-related cardiac injury in newborns from preeclamptic mothers within the first 24-48 hours of their lifetime. Impact statement Today, the methods which may detect cardiac injury earlier than conventional echocardiographic methods are used for evaluating cardiac functions. Among them, myocardial performance index (MPI) measurement with PW Doppler is the most common ones. While studies are available in the literature evaluating foetal cardiac functions with MPI in foetuses of preeclamptic women, studies evaluating cardiac functions with MPI index within the first 24-48 hours in postnatal period are not available. This is the first study to detect cardiac injury by measuring cardiac functions of the newborns of preeclamptic babies using conventional echocardiography (EF, SF, mitral and tricuspid E/A) and myocardial performance index within the first 24-48 hours of life and compare these values with those of a control group composed of healthy newborns with similar demographic characteristics. According to the results of the study, elongation in right and left ventricle MPI was detected to be more significant compared to systolic and diastolic functions for determining preeclampsia-related cardiac injury in newborns of preeclamptic mothers within 24-48 hours of delivery. Ventricle functions of the newborns of preeclamptic mothers should also be evaluated with MPI measurement besides conventional echocardiographic measurements.


Asunto(s)
Ecocardiografía/métodos , Cardiopatías/diagnóstico por imagen , Preeclampsia , Efectos Tardíos de la Exposición Prenatal/diagnóstico por imagen , Adulto , Estudios de Casos y Controles , Femenino , Corazón/diagnóstico por imagen , Corazón/fisiopatología , Cardiopatías/fisiopatología , Humanos , Recién Nacido , Periodo Posparto , Embarazo , Efectos Tardíos de la Exposición Prenatal/fisiopatología , Función Ventricular/fisiología , Adulto Joven
8.
Minerva Pediatr ; 70(4): 365-370, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26041003

RESUMEN

BACKGROUND: The aim of the study was to perform a neurodevelopmental evaluation of the children with cyanotic congenital heart disease and to determine the factors that affect the neurodevelopmental status. METHODS: The study was performed in the Pediatric Cardiology Department of Behcet Uz Children's Hospital between February and August 2013. Children between the age of six to forty-two months were included in the study and were evaluated in three groups (two patient groups and the control group). In group A, patients with isolated cyanotic congenital heart disease were enrolled. Group B consisted of the patients with cyanotic congenital heart disease with other concomitant diseases. Group C included the healthy control group. For the neurodevelopmental evaluation Bayley Scale of Infant Development- II (BSID-II) was used. Mental Developmental Index (MDI) and Psychmotor Developmental Index (PDI) scores were calculated. Factors possibly effective on neurodevelopment were evaluated. RESULTS: Thirty eight patients (32 in group A and 6 in group B) and 33 healthy subjects in group C were included in the study. Mean age of the patient group was 22.5±11.2 months. In group A mean MDI Score (82.5±14.7) was significantly lower than group C (92.3±6.9) (P=0.001). Similarly mean PDI Score in group A (82.0±18.2) was found significantly lower than group C (92.5±7.4) (P=0.003). When group A and B were compared, mean MDI and PDI scores were lower in group B, but the difference was not statistically significant. For group A, according to the psychomotor development index, 41.6% of the patients were found to be mildly to severely retarded. In terms of the mental development index, 34.4% of the patients had moderate or mild retardation. The sex, socioeconomic status, gestational age, birth weight, comorbidities, history of surgery and reoperation, length of stay in intensive care unit were not found influential on the MDI and PDI scores of the patients. CONCLUSIONS: Mental-motor retardation is frequently encountered in children with cyanotic congenital heart disease. These patients may benefit from motor, language, speech, developmental and educational therapies. For this reason, these children have to be under regular follow up for neurodevelopmental status.


Asunto(s)
Desarrollo Infantil/fisiología , Cianosis/congénito , Discapacidades del Desarrollo/epidemiología , Cardiopatías Congénitas/complicaciones , Estudios de Casos y Controles , Preescolar , Cianosis/complicaciones , Femenino , Humanos , Lactante , Discapacidad Intelectual/epidemiología , Discapacidad Intelectual/fisiopatología , Masculino , Factores de Riesgo , Índice de Severidad de la Enfermedad , Turquía
9.
Ann Noninvasive Electrocardiol ; 21(4): 369-75, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26524222

RESUMEN

BACKGROUND: We aimed to examine microvolt T wave alternans (MTWA) in 24-hour Holter electrocardiography (ECG) of children with repaired tetralogy of Fallot (TOF) to assess associations of MTWA with ventricular arrhythmias, ECG parameters, and echocardiographic findings. METHODS: Holter ECG records and archive files of 56 repaired TOF patients (62.5% male) who were analyzed retrospectively. Subjects' ECG parameters and MTWA values were compared with age-sex-matched control group. T wave changes were analyzed by time-domain-modified moving average method from the three channels of 24-hour Holter ECG. RESULTS: Mean age was 123.4 ± 48.3 months. Median MTWA value was 55.5 µV in the control group, whereas 95.5 µV in patients group (P < 0.001). A significant weak positive correlation was found between the presence of ventricular extrasystoles and tricuspid regurgitation. There was no correlation between ECG parameters, echocardiographic findings, and MTWA. CONCLUSIONS: MTWA was increased in children with repaired TOF as reported before. To our knowledge, this is the first study analyzing MTWA with 24-hour Holter ECG in repaired TOF patients.


Asunto(s)
Electrocardiografía/métodos , Tetralogía de Fallot/fisiopatología , Adolescente , Niño , Preescolar , Ecocardiografía , Electrocardiografía Ambulatoria , Femenino , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Masculino , Estudios Retrospectivos , Tetralogía de Fallot/cirugía
10.
J Clin Ultrasound ; 44(3): 170-4, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26402028

RESUMEN

PURPOSE: The purpose of this study was to investigate fetal ductus venosus (DV) wave velocities, DV velocity ratios, and DV diastolic time intervals to derive additional information on fetal cardiac function in the presence of an intracardiac echogenic focus (IEF). METHODS: Seventy fetuses at 19-28 weeks of gestation with an IEF and 63 control fetuses were screened using two-dimensional and power Doppler echocardiography. DV wave velocities, DV velocity ratios, and diastolic time intervals were measured. The aortic peak velocity, pulmonary artery peak velocity, left ventricular shortening fraction, and right ventricular shortening fraction, atrioventricular early-diastolic filling velocity (E), atrial contraction velocity (A), and E/A ratio were also measured. RESULTS: The study and control groups were similar in terms of maternal age, body mass index, and gestational age in weeks at the time of examination (p > 0.05). Significant between-group differences were found in DV v-descent (p = 0.03) and a-wave velocities (p = 0.04). CONCLUSIONS: Although the presence of an IEF in the fetal heart does not influence conventional measurements (DV velocity ratios and DV diastolic time intervals), it is associated with changes in DV v-descent and a-wave velocities. These changes may be indirectly related to reduced end-systolic relaxation and augmented atrial contraction in the fetal heart. We therefore suggest examination of DV flow velocities in fetuses with IEF.


Asunto(s)
Corazón Fetal/diagnóstico por imagen , Corazón Fetal/fisiología , Ultrasonografía Prenatal/métodos , Adulto , Velocidad del Flujo Sanguíneo/fisiología , Ecocardiografía Doppler/métodos , Femenino , Humanos , Embarazo , Reproducibilidad de los Resultados
11.
Cardiol Young ; 25(5): 911-7, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25022620

RESUMEN

OBJECTIVE: To assess haemodynamic patterns in head-up tilt testing on 400 paediatric cases with unexplained syncope. METHODS: Medical records of 520 children who underwent head-up tilt testing in the preceding year were retrospectively evaluated, and 400 children, 264 (66%) girls and 136 (34%) boys, aged 12.6±2.6 years (median 13; range 5-18), with unexplained syncope were enrolled in the study. Age, sex, baseline heart rate, baseline blood pressure, frequency of symptoms, and/or fainting attacks were recorded. The test protocol consisted of 25 minutes of supine resting followed by 20 minutes of 70° upright positioning. Subjects were divided into nine groups according to their differing haemodynamic patterns. RESULTS: There were no statistically significant differences between the groups with regard to age, gender, baseline blood pressure, and frequency of syncope (p>0.05). The response was compatible with orthostatic intolerance in 28 cases (7.0%), postural orthostatic tachycardia syndrome in 24 cases (6.0%), asymptomatic postural orthostatic tachycardia syndrome in 26 cases (6.5%), orthostatic hypotension in seven cases (1.7%), vasovagal syncope in 38 cases (9.5%), and negative in 274 cases (69.2%). Vasovagal syncope response patterns were of type 3 in nine cases (2.2%), type 2A in 10 cases (2.5%), type 2B in two cases (0.5%), and type 1 (mixed) in 17 cases (4.25%). CONCLUSIONS: In the 400 paediatric cases with unexplained syncope, nine different haemodynamic response patterns to head-up tilt testing were discerned. Children with orthostatic intolerance syndromes are increasingly referred to hospitals because of difficulty in daily activities. Therefore, there is need for further clinical trials in these patient groups.


Asunto(s)
Hemodinámica/fisiología , Síndrome de Taquicardia Postural Ortostática/diagnóstico , Síncope/diagnóstico , Pruebas de Mesa Inclinada , Adolescente , Niño , Preescolar , Femenino , Humanos , Masculino , Síndrome de Taquicardia Postural Ortostática/fisiopatología , Estudios Retrospectivos , Síncope/fisiopatología , Síncope Vasovagal/diagnóstico , Síncope Vasovagal/fisiopatología
12.
Pediatr Cardiol ; 35(8): 1344-8, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24859169

RESUMEN

Reports state that Down syndrome (DS) patients with congenitally normal hearts might experience the development of cardiac abnormalities such as cardiac autonomic dysfunction, valvular lesions, bradycardia, and atrioventricular block. However, the presence of any difference in terms of P-wave dispersion (PWd) and QT dispersion (QTd) was not evaluated previously. This study prospectively investigated 100 DS patients with structurally normal hearts and 100 age- and sex-matched healthy control subjects. Standard 12-lead electrocardiograms were used to assess and compare P-wave and QT durations together with PWd and QTd. The median age of the DS patients and control subjects was 48 months. Heart rates and P-wave and QT dispersions were significantly greater in the DS group than in the control group (113 ± 22.9 vs 98.8 ± 16.6 bpm, p < 0.001; 31.3 ± 9.5 vs 24 ± 8.6 ms, p < 0.001; and 46.6 ± 15.9 vs 26 ± 9.1 ms, p < 0.001, respectively). A positive correlation was found between PWd and age in the DS patients (p < 0.05; r = 0.2). All children with DS should be followed up carefully with electrocardiography in terms of increased P-wave and QT dispersions even in the absence of concomitant congenital heart disease for management of susceptibility to arryhthmias.


Asunto(s)
Arritmias Cardíacas/diagnóstico , Síndrome de Down/fisiopatología , Electrocardiografía , Frecuencia Cardíaca/fisiología , Arritmias Cardíacas/etiología , Arritmias Cardíacas/fisiopatología , Estudios de Casos y Controles , Preescolar , Síndrome de Down/complicaciones , Diagnóstico Precoz , Femenino , Humanos , Masculino , Estudios Prospectivos
13.
Healthcare (Basel) ; 12(10)2024 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-38786453

RESUMEN

Aim: To evaluate using different iron preparations for iron deficiency and/or iron deficiency anemia prophylaxis in infants and their iron status. Methods: In this study, we retrospectively evaluated the electronic patient records of 651 healthy children aged 9 to 13 months who met the inclusion criteria and who were followed up in pediatric follow-up outpatient clinics between January 2023 and June 2023. Results: A total of 651 children with a mean age of 11.2 ± 1.4 months, 54.7% of whom were boys, who met the inclusion criteria were included in the study; 56.5% of the children were using Fe + 3 salt and the others were using Fe + 2 salt, microencapsulated iron, or sucrosomial iron drops. After the fifth month of prophylaxis, when the effects of the iron preparations used on the mean laboratory values were evaluated, it was found that hemoglobin, serum iron, and ferritin levels were lower in sucrosomial iron and microencapsulated iron users compared to other preparations (p = 0.001). When statistically pairwise comparisons were made between the groups, hemoglobin and serum iron values were found to be lower in the group using sucrosomial iron compared to the groups using Fe + 2 and Fe + 3 salts (p < 0.0001). Hemoglobin and ferritin levels were higher in the group using Fe + 2 salt compared to both sucrosomial iron and microencapsulated iron groups (p < 0.0001). When the infants were evaluated according to iron status, it was found that 208 (31.9%) had iron deficiency. Iron deficiency was found to be less in infants of families who defined their economic status as rich and in infants who used iron regularly (p-values 0.044 and 0.001, respectively). Iron deficiency/iron deficiency anemia was observed at a higher rate in the group using sucrosomial iron and microencapsulated iron prophylaxis (p = 0.001). Conclusions: To prevent iron deficiency, it is very important to use appropriate iron preparations for prophylaxis and to feed foods with high iron content. Although we found that families were willing to use different iron preparations other than iron salts for their infants, the results presented herein indicate that the rate of iron deficiency was lower in patients using iron salts. However, randomized controlled studies are needed to determine whether these preparations are effective in iron prophylaxis in infants.

14.
J Pediatr Endocrinol Metab ; 26(1-2): 129-31, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23457314

RESUMEN

Attempted suicide with levothyroxine is very rare and has been described only in a few case reports. Although acute accidental or intentional overdoses of thyroid hormones can lead to marked elevations in serum T4 levels, many children who take as much as 5-10 mg of levothyroxine as a single dose have few or no symptoms of thyrotoxicosis. We report an adolescent girl who attempted suicide by ingesting levothyroxine. She responded well to ß-adrenergic blockade.


Asunto(s)
Intento de Suicidio , Tirotoxicosis/inducido químicamente , Tiroxina/toxicidad , Adolescente , Antagonistas Adrenérgicos beta/uso terapéutico , Femenino , Humanos , Tirotoxicosis/diagnóstico , Tirotoxicosis/tratamiento farmacológico
15.
Paediatr Anaesth ; 23(4): 368-70, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23302011

RESUMEN

Following a propofol anesthetic, a 5-year-old girl with lower extremity spasticity seized and developed hypertriglyceridemia, hyperkalemia, and metabolic acidosis. A presumed diagnosis of propofol infusion syndrome (PRIS) was made, but further investigation revealed neonatal adrenoleukodystrophy. PRIS should be considered with this constellation of symptoms, but other neurometabolic disorders must always be ruled out.


Asunto(s)
Anestésicos Intravenosos/efectos adversos , Enfermedades Mitocondriales/diagnóstico , Trastorno Peroxisomal/diagnóstico , Propofol/efectos adversos , Acidosis/complicaciones , Análisis de los Gases de la Sangre , Parálisis Cerebral/complicaciones , Preescolar , Femenino , Humanos , Pruebas de Función Hepática , Imagen por Resonancia Magnética , Enfermedades Mitocondriales/terapia , Trastorno Peroxisomal/terapia
16.
Pediatr Emerg Care ; 29(9): 992-7, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23974719

RESUMEN

INTRODUCTION: The aim of this study was to compare the body temperature measurements of infrared tympanic and forehead noncontact thermometers with the axillary digital thermometer. METHODS: Randomly selected 50 pediatric patients who were hospitalized in Dr Behcet Uz Children's Training and Research Hospital, Pediatric Infectious Disease Unit, between March 2012 and September 2012 were included in the study. Body temperature measurements were performed using an axillary thermometer (Microlife MT 3001), a tympanic thermometer (Microlife Ear Thermometer IR 100), and a noncontact thermometer (ThermoFlash LX-26). RESULTS: Fifty patients participated in this study. We performed 1639 temperature readings for every method. The average difference between the mean (SD) of both axillary and tympanic temperatures was -0.20°C (0.61°C) (95% confidence interval, -1.41°C to 1.00°C). The average difference between the mean (SD) of both axillary and forehead temperatures was -0.38 (0.55°C) (95% confidence interval, -1.47°C to 0.70°C). The Bland-Altman plot showed that most of the data points were tightly clustered around the zero line of the difference between the 2 temperature readings. With the use of the axillary method as the criterion standard, positive likelihood ratios were 17.9 and 16.5 and negative likelihood ratios were 0.2 and 0.4 for tympanic and forehead measurements, respectively. DISCUSSION: The results demonstrated that the infrared tympanic thermometer could be a good option in the measurement of fever in the pediatric population. The noncontact infrared thermometer is very useful for the screening of fever in the pediatric population, but it must be used with caution because it has a high value of bias.


Asunto(s)
Temperatura Corporal , Pediatría/instrumentación , Termómetros , Adolescente , Axila , Niño , Preescolar , Oído Medio , Diseño de Equipo , Femenino , Fiebre/diagnóstico , Frente , Hospitales Pediátricos , Humanos , Lactante , Infectología , Rayos Infrarrojos , Masculino , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Muestreo , Sensibilidad y Especificidad , Temperatura Cutánea , Termómetros/clasificación
17.
Exp Clin Transplant ; 21(6): 540-542, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37455474

RESUMEN

Sevoflurane is a volatile anesthetic agent that does not tend to cause clinically significant hepatotoxicity, but there are some reported hepatotoxicity cases in the literature. In the case presented here, adenotonsillectomy was performed during influenza infection, and sevoflurane was administered, after which acute fulminant hepatitis developed. At hour 24 of hospitalization after fulminant hepatic failure, liver transplant was performed in a 3.5-year-old patient without any known diseases. In such cases, etiology investigations should be planned, life support therapy should be administered, and information should be given to the patient to avoid exposure to sevoflurane in the future.


Asunto(s)
Enfermedad Hepática Inducida por Sustancias y Drogas , Hepatitis , Gripe Humana , Fallo Hepático Agudo , Humanos , Preescolar , Sevoflurano/efectos adversos , Gripe Humana/complicaciones , Gripe Humana/diagnóstico , Gripe Humana/tratamiento farmacológico , Fallo Hepático Agudo/inducido químicamente , Fallo Hepático Agudo/diagnóstico , Fallo Hepático Agudo/cirugía
18.
Front Pediatr ; 11: 1326550, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38313403

RESUMEN

Background: In pediatric intensive care units, extubation failure following invasive mechanical ventilation poses significant health risks. Determining readiness for extubation in children can minimize associated morbidity and mortality. This study investigates the potential role of renal near-infrared spectroscopy (RrSO2) in predicting extubation failure in pediatric patients. Methods: A total of 84 patients aged between 1 month and 18 years, mechanically ventilated for at least 24 h, were included in this prospective study. RrSO2 levels were measured using near-infrared spectroscopy before and during an extubation readiness test (ERT). The primary outcome measure was extubation failure, defined as a need for reintubation within 48 h. Results: Of the 84 patients, 71 (84.6%) were successfully extubated, while 13 (15.4%) failed extubation. RrSO2 was found to be lower in the failed extubation group, also decrease in RrSO2 values during ERT was significantly greater in patients with extubation failure. ROC analysis indicated a decrease in ΔRrSO2 of more than 6.15% from baseline as a significant predictor of extubation failure, with a sensitivity of 0.984 and a specificity of 0.889. Conclusion: Monitoring changes in RrSO2 values may serve as a helpful tool to predict extubation failure in pediatric patients. Further multi-center research is warranted to improve the generalizability and reliability of these findings.

19.
Arch Pediatr ; 29(2): 140-144, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35039188

RESUMEN

OBJECTIVE: The aim of this study was to determine the association between the use of intravenous N-acetylcysteine (NAC) and hepatic healing in pediatric intensive care unit (PICU) patients with non-acetaminophen-induced hepatic injury, except for acute liver failure. METHODS: The data of patients who received intravenous NAC as adjuvant therapy for transaminase levels more than sixfold normal values during their PICU stay between 2010 and 2014 were retrospectively collected from the medical records database. The patients who did not receive NAC with elevated transaminase levels during their PICU stay between 2014 and 2018 were also collected as the standard of care (SOC) cohort. RESULTS: More than 50% of the liver injuries were secondary to acute hypoxia, hypotension, sepsis, and inflammation. The median number of elevated transaminase period (ETP) days of the NAC and SOC groups were 5 (IQR: 4) and 4 (IQR: 4), respectively (p = 0.17). There was no significant difference between the groups in terms of minimum and maximum laboratory values during ETP. There was no significant difference in terms of ETP and maximum ALT levels between the NAC and SOC groups in the hypoxia-hypotension subgroup. CONCLUSION: This study did not show an association between indirect measures of hepatic healing and post-insult use of NAC in pediatric liver injury in the PICU setting.


Asunto(s)
Acetilcisteína/uso terapéutico , Enfermedad Hepática Inducida por Sustancias y Drogas , Fallo Hepático Agudo/tratamiento farmacológico , Acetaminofén , Analgésicos no Narcóticos/uso terapéutico , Enfermedad Hepática Inducida por Sustancias y Drogas/etiología , Niño , Cuidados Críticos , Femenino , Humanos , Fallo Hepático Agudo/etiología , Masculino , Estudios Retrospectivos , Transaminasas/sangre , Resultado del Tratamiento
20.
Front Med (Lausanne) ; 9: 1046902, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36465920

RESUMEN

Background: We assessed the effect of a closed-loop oxygen control system in pediatric patients receiving high-flow nasal oxygen therapy (HFNO). Methods: A multicentre, single-blinded, randomized, and cross-over study. Patients aged between 1 month and 18 years of age receiving HFNO for acute hypoxemic respiratory failure (AHRF) were randomly assigned to start with a 2-h period of closed-loop oxygen control or a 2-h period of manual oxygen titrations, after which the patient switched to the alternative therapy. The endpoints were the percentage of time spent in predefined SpO2 ranges (primary), FiO2, SpO2/FiO2, and the number of manual adjustments. Findings: We included 23 patients, aged a median of 18 (3-26) months. Patients spent more time in a predefined optimal SpO2 range when the closed-loop oxygen controller was activated compared to manual oxygen titrations [91⋅3% (IQR 78⋅4-95⋅1%) vs. 63⋅0% (IQR 44⋅4-70⋅7%)], mean difference [28⋅2% (95%-CI 20⋅6-37⋅8%); P < 0.001]. Median FiO2 was lower [33⋅3% (IQR 26⋅6-44⋅6%) vs. 42⋅6% (IQR 33⋅6-49⋅9%); P = 0.07], but median SpO2/FiO2 was higher [289 (IQR 207-348) vs. 194 (IQR 98-317); P = 0.023] with closed-loop oxygen control. The median number of manual adjustments was lower with closed-loop oxygen control [0⋅0 (IQR 0⋅0-0⋅0) vs. 0⋅5 (IQR 0⋅0-1⋅0); P < 0.001]. Conclusion: Closed-loop oxygen control improves oxygenation therapy in pediatric patients receiving HFNO for AHRF and potentially leads to more efficient oxygen use. It reduces the number of manual adjustments, which may translate into decreased workloads of healthcare providers. Clinical trial registration: [www.ClinicalTrials.gov], identifier [NCT05032365].

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA