RESUMEN
A Microsoft Excel utility, HX-Express, that significantly accelerates the analysis of hydrogen exchange mass spectrometry data is described. HX-Express generates deuterium uptake and peak width plots from peaks in mass spectral data. Data analysis is intentionally semi-automated, requiring that the user find the peaks to be analyzed. The peaks are entered in the form of x, y lists of m/z versus intensity or can be directly imported from Waters MassLynx software. Analysis of data with HX-Express provides the same results as manual data processing but is substantially faster. In addition to speed, HX-Express provides and preserves visual and numeric displays of the analysis process for quality control.
Asunto(s)
Algoritmos , Medición de Intercambio de Deuterio/métodos , Modelos Químicos , Modelos Moleculares , Programas Informáticos , Espectrometría de Masa por Ionización de Electrospray/métodos , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Simulación por Computador , Hidrógeno/análisis , Hidrógeno/química , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Interfaz Usuario-ComputadorRESUMEN
The performance characteristics of multidimensional liquid chromatographic protein separations were evaluated using on-line electrospray mass detection, and a novel workflow for automated LC/MS data processing. Two-dimensional ion exchange/reversed-phase LC separations of Escherichia coli cytosol were conducted using either a continuous linear or discontinuous step gradient in the first dimension. Chromatographic profiles of the top 100 most abundant components were characterized to assess overall separation reproducibility within each mode, and to characterize differences in component distribution between the two modes of operation. Analysis of the resulting data indicates that multidimensional separations of complex protein mixtures can be done reproducibly. Furthermore, under the conditions employed within this study, a linear first dimension gradient was more effective at fractionating the protein mixture, distributing fewer major components to multiple second dimension cycles than an equivalent step gradient. The application of on line mass spectrometry, and automated processing of the resulting data, proved valuable for producing component level analysis of multidimensional protein separations.
Asunto(s)
Cromatografía por Intercambio Iónico/métodos , Cromatografía Liquida/métodos , Proteínas/aislamiento & purificación , Espectrometría de Masa por Ionización de Electrospray/métodos , Escherichia coli/química , Péptidos/aislamiento & purificación , Reproducibilidad de los ResultadosRESUMEN
BACKGROUND: The profiling and quantification of drug metabolites in discovery and development bioanalysis studies is playing an increasingly important role in early candidate selection. Using a conventional tandem quadrupole mass spectrometer this activity normally requires several analytical runs to acquire the necessary analytical data. RESULTS: In this article we present the use of a new tandem quadrupole mass spectrometer equipped with a novel collision cell design, which allows the rapid switching between multiple reaction monitoring and full-scan MS mode. This approach allowed for the collection of multiple reaction monitoring data and full-scan data with no loss in sensitivity, with analysis times in the 1-2 min range. CONCLUSION: A modified approach of using the multiple reaction monitoring data to trigger the acquisition of full scan MS/MS data is described, where the data is collected on the trailing edge of the LC-MS peak, thus improving data quality and throughput.
Asunto(s)
Cromatografía Liquida/métodos , Preparaciones Farmacéuticas/análisis , Preparaciones Farmacéuticas/metabolismo , Farmacocinética , Espectrometría de Masas en Tándem/métodos , Animales , Descubrimiento de Drogas , Glucurónidos/análisis , Glucurónidos/metabolismo , Glucurónidos/farmacocinética , Propranolol/análisis , Propranolol/metabolismo , Propranolol/farmacocinética , RatasRESUMEN
Current methodologies for protein quantitation include 2-dimensional gel electrophoresis techniques, metabolic labeling, and stable isotope labeling methods to name only a few. The current literature illustrates both pros and cons for each of the previously mentioned methodologies. Keeping with the teachings of William of Ockham, "with all things being equal the simplest solution tends to be correct", a simple LC/MS based methodology is presented that allows relative changes in abundance of proteins in highly complex mixtures to be determined. Utilizing a reproducible chromatographic separations system along with the high mass resolution and mass accuracy of an orthogonal time-of-flight mass spectrometer, the quantitative comparison of tens of thousands of ions emanating from identically prepared control and experimental samples can be made. Using this configuration, we can determine the change in relative abundance of a small number of ions between the two conditions solely by accurate mass and retention time. Employing standard operating procedures for both sample preparation and ESI-mass spectrometry, one typically obtains under 5 ppm mass precision and quantitative variations between 10 and 15%. The principal focus of this paper will demonstrate the quantitative aspects of the methodology and continue with a discussion of the associated, complementary qualitative capabilities.