Hepatol Res ; 53(8): 749-760, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37036153

RESUMEN

AIM: We aimed to verify the therapeutic efficacy and safety of stereotactic body radiotherapy (SBRT) for previously untreated initial small hepatocellular carcinoma (HCC) in a multicenter, retrospective study. METHODS: Patients who underwent SBRT for HCC at the Japanese Society of Clinical Oncology (JCOG) member hospitals in Japan between July 2013 and December 2017 and met the following eligibility criteria were included: (1) initial HCC; (2) ≤3 nodules, ≤5 cm in diameter; (3) Child-Pugh score of A or B; and (4) unsuitability for or refusal of standard treatment. We analyzed the overall survival, recurrence-free survival, and cumulative incidence of local recurrence rate, and adverse events directly related to SBRT. RESULTS: Seventy-three patients with 79 lesions from 14 hospitals were analyzed. The median age was 77 years (range: 50-89 years), and the median tumor size was 23 mm (range: 6-50 mm). The median radiation dose was 40 Gy (range: 35-60 Gy) in five fractions (range: 4-8). The median follow-up period was 45 months (range: 0-103 months). The 3-year overall survival, recurrence-free survival, and cumulative incidence of local recurrence rates were 69.9% (95% CI: 58.7%-81%), 57.9% (95% CI: 45.2%-70.5%), and 20.0% (95% CI: 11.2%-30.5%), respectively. Four cases (5.5%) of adverse events of grade 3 or higher were reported: three cases of grade 3 and one case of grade 4 (duodenal ulcer). No grade 5 toxicities were observed. CONCLUSION: SBRT is a promising treatment modality, particularly for small HCCs, as they are not suitable for standard treatment.

2.
Hepatol Res ; 51(4): 461-471, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33217113

RESUMEN

AIM: To prospectively evaluate the efficacy and safety of stereotactic body radiotherapy (SBRT) for patients with previously untreated solitary primary hepatocellular carcinoma (HCC). METHODS: The main eligibility criteria included the following: (1) primary solitary HCC; (2) no prior treatment for HCC; (3) Child-Turcotte-Pugh score of seven or less; and (4) unsuitability for or refusal of surgery and radiofrequency ablation (RFA). The prescribed dose of SBRT was 40 Gy in five fractions. The primary endpoint was 3-year overall survival (OS); the secondary endpoints included local progression-free survival (LPFS), local control (LC), and adverse events. The accrual target was 60 patients, expecting a 3-year OS of 70% with a 50% threshold. RESULTS: Between 2014 and 2018, 36 patients were enrolled; enrollment was closed early because of slow accrual. The median tumor size was 2.3 cm. The median follow-up at the time of evaluation was 20.8 months. The 3-year OS was 78% (95% confidence interval [CI]: 53%-90%). The 3-year LPFS and LC proportion were 73% (95% CI: 48%-87%) and 90% (95% CI: 65%-97%), respectively. Grade 3 or higher SBRT-related toxicities were observed in four patients (11%), and grade five toxicities were not observed. CONCLUSIONS: This study showed acceptably low incidence of SBRT-related toxicities. LC and OS after SBRT were comparable for previously untreated solitary HCC for patients unfit for resection and RFA. Although a definitive conclusion cannot be drawn by this study, the promising results indicate that SBRT may be an alternative option in the management of early HCC.

3.
Hepatol Res ; 51(8): 870-879, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33894086

RESUMEN

AIM: To report the outcomes of stereotactic body radiotherapy using a real-time tumor-tracking radiotherapy system for hepatocellular carcinoma patients. METHODS: From January 2005 to July 2018, 63 patients with 74 lesions with a maximum diameter ≤52 mm were treated by stereotactic body radiotherapy using a real-time tumor-tracking radiotherapy system. No patient with a Child-Pugh Score ≥9 was included, and 85.6% had a score of 5 or 6. Using the biological effective dose (BED) with an α/ß ratio of 10 (BED10 ), the median dose in BED10 at the reference point was 76.8 Gy (range 60-122.5 Gy). Overall survival (OS) and local control rates were assessed using the Kaplan-Meier method. RESULTS: With a median follow-up period of 24.6 months (range 0.9-118.4 months), the 1-year and 2-year OS rates were 86.8% (95% confidence interval [95% CI] 75.8-93.3) and 71.1% (57.8-81.6), respectively. The 2-year OS was 89.6% in patients with the baseline modified albumin-bilirubin (mALBI) grade =1, and 61.7% in patients with grade ≥2a. In the multivariate analysis, the mALBI grade (=1 vs. ≥2a) was a significant factor for OS (p = 0.028, 95% CI 1.11-6.18). The 1-year and 2-year local control rates were 100% (100-100%) and 92.0% (77.5-97.5%). The local control rates were significantly higher in the BED10 ≥100 Gy group than in the BED10 <100 Gy group (2-year 100% vs. 86.5%, p = 0.049) at the reference point. CONCLUSION: This retrospective study of stereotactic body radiotherapy using real-time tumor-tracking radiotherapy for hepatocellular carcinoma showed favorable outcomes with lower incidence of toxicities, especially in patients treated with BED10 ≥100 Gy to the reference point.

4.
J Appl Clin Med Phys ; 21(2): 38-49, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31886616

RESUMEN

We developed a synchrotron-based real-time-image gated-spot-scanning proton-beam therapy (RGPT) system and utilized it to clinically operate on moving tumors in the liver, pancreas, lung, and prostate. When the spot-scanning technique is linked to gating, the beam delivery time with gating can increase, compared to that without gating. We aim to clarify whether the total treatment process can be performed within approximately 30 min (the general time per session in several proton therapy facilities), even for gated-spot-scanning proton-beam delivery with implanted fiducial markers. Data from 152 patients, corresponding to 201 treatment plans and 3577 sessions executed from October 2016 to June 2018, were included in this study. To estimate the treatment process time, we utilized data from proton beam delivery logs during the treatment for each patient. We retrieved data, such as the disease site, total target volume, field size at the isocenter, and the number of layers and spots for each field, from the treatment plans. We quantitatively analyzed the treatment process, which includes the patient load (or setup), bone matching, marker matching, beam delivery, patient unload, and equipment setup, using the data obtained from the log data. Among all the cases, 90 patients used the RGPT system (liver: n = 34; pancreas: n = 5; lung: n = 4; and prostate: n = 47). The mean and standard deviation (SD) of the total treatment process time for the RGPT system was 30.3 ± 7.4 min, while it was 25.9 ± 7.5 min for those without gating treatment, excluding craniospinal irradiation (CSI; head and neck: n = 16, pediatric: n = 31, others: n = 15); for CSI (n = 11) with two or three isocenters, the process time was 59.9 ± 13.9 min. Our results demonstrate that spot-scanning proton therapy with a gating function can be achieved in approximately 30-min time slots.


Asunto(s)
Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias de la Próstata/diagnóstico por imagen , Terapia de Protones/métodos , Radioterapia Guiada por Imagen/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Femenino , Marcadores Fiduciales , Humanos , Lactante , Recién Nacido , Modelos Lineales , Neoplasias Hepáticas/radioterapia , Neoplasias Pulmonares/radioterapia , Masculino , Persona de Mediana Edad , Neoplasias Pancreáticas/radioterapia , Neoplasias de la Próstata/radioterapia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Reproducibilidad de los Resultados , Sincrotrones , Factores de Tiempo , Adulto Joven
5.
J Appl Clin Med Phys ; 21(12): 10-19, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33151643

RESUMEN

A synchrotron-based real-time image gated spot-scanning proton beam therapy (RGPT) system with inserted fiducial markers can irradiate a moving tumor with high accuracy. As gated treatments increase the beam delivery time, this study aimed to investigate the frequency of intra-field adjustments corresponding to the baseline shift or drift and the beam delivery efficiency of a synchrotron-based RGPT system. Data from 118 patients corresponding to 127 treatment plans and 2810 sessions between October 2016 and March 2019 were collected. We quantitatively analyzed the proton beam delivery time, the difference between the ideal beam delivery time based on a simulated synchrotron magnetic excitation pattern and the actual treatment beam delivery time, frequency corresponding to the baseline shift or drift, and the gating efficiency of the synchrotron-based RGPT system according to the proton beam delivery machine log data. The mean actual beam delivery time was 7.1 min, and the simulated beam delivery time in an ideal environment with the same treatment plan was 2.9 min. The average difference between the actual and simulated beam delivery time per session was 4.3 min. The average frequency of intra-field adjustments corresponding to baseline shift or drift and beam delivery efficiency were 21.7% and 61.8%, respectively. Based on our clinical experience with a synchrotron-based RGPT system, we determined the frequency corresponding to baseline shift or drift and the beam delivery efficiency using the beam delivery machine log data. To maintain treatment accuracy within ± 2.0 mm, intra-field adjustments corresponding to baseline shift or drift were required in approximately 20% of cases. Further improvements in beam delivery efficiency may be realized by shortening the beam delivery time.


Asunto(s)
Neoplasias , Terapia de Protones , Marcadores Fiduciales , Humanos , Neoplasias/radioterapia , Cintigrafía , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Sincrotrones
6.
Minim Invasive Ther Allied Technol ; 29(6): 334-343, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31516050

RESUMEN

Purpose: This study evaluated the success rate and complications of percutaneous implantation of hepatic fiducial true-spherical gold markers for real-time adaptive radiotherapy (RAR), which constitutes real-time image-guided radiotherapy with gating.Material and methods: We retrospectively evaluated 100 patients who underwent 116 percutaneous intrahepatic implantations of 2-mm-diameter, spherical, gold fiducial markers before RAR from 1999 to 2016, with Seldinger's method. We defined technical success as marker placement at the intended liver parenchyma, without mispositioning, and clinical success as successful tracking of the gold marker and completion of planned RAR. Complications related to marker placement were assessed.Results: The technical success rate for true-spherical gold marker implantation was 92.2% (107/116). Nine of 116 markers migrated (intra-procedurally in seven patients, delayed in two patients). Migration out of the liver (n = 4) or intrahepatic vessels (n = 5) occurred without complications; these markers were not retrieved. The clinical success rate was 100.0% (115/115). Abdominal pain occurred in 16 patients, fever and hemorrhage in seven patients each, and pneumothorax and nausea in one patient each. No major complications were encountered.Conclusions: Percutaneous transhepatic implantation of true-spherical gold markers for RAR is feasible and can be conducted with a high success rate and low complication rate.


Asunto(s)
Neoplasias Hepáticas , Radioterapia Guiada por Imagen , Marcadores Fiduciales , Humanos , Estudios Retrospectivos
7.
J Appl Clin Med Phys ; 20(8): 78-86, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31400082

RESUMEN

PURPOSE: Interplay effects may influence dose distributions to a moving target when using dynamic delivery techniques such as intensity-modulated radiotherapy (IMRT). The aim of this study was to evaluate the impact of organ motion on volumetric and dosimetric parameters in stomach lymphomas treated with IMRT. METHODS: Ten patients who had been treated with IMRT for stomach lymphomas were enrolled. The clinical target volume (CTV) was contoured as the whole stomach. Considering interfractional uncertainty, the internal target volume (ITV) margin was uniformly 1.5 cm to the CTV and then modified based on the 4DCT images in case of the large respiratory motion. The planning target volume (PTV) was created by adding 5 mm to the ITV. The impact of organ motion on the volumetric and dosimetric parameters was evaluated retrospectively (4D simulation). The organ motion was reproduced by shifting the isocenter on the radiation treatment planning system. Several simulation plans were created to test the influence of the beam-on timing in the respiration cycle on the dose distribution. The homogeneity index (HI), volume percentage of stomach covered by the prescribed dose (Vp ), and D99 of the CTV were evaluated. RESULTS: The organ motion was the largest in the superior-inferior direction (10.1 ± 4.5 mm [average ± SD]). Stomach volume in each respiratory phase compared to the mean volume varied approximately within a ± 5% range in most of the patients. The PTV margin was sufficiently large to cover the CTV during the IMRT. There was a significant reduction in Vp and D99 but not in HI in the 4D simulation in free-breathing and multiple fractions compared to the clinically-used plan (P < 0.05) suggesting that interplay effects deteriorate the dose distribution. The absolute difference of D99 was less than 1% of the prescribed dose. CONCLUSIONS: There were significant interplay effects affecting the dose distribution in stomach IMRT. The magnitude of the dose reduction was small when patients were treated on free-breathing and multiple fractions.


Asunto(s)
Linfoma/radioterapia , Movimientos de los Órganos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Respiración , Neoplasias Gástricas/radioterapia , Humanos , Linfoma/fisiopatología , Órganos en Riesgo/efectos de la radiación , Pronóstico , Dosificación Radioterapéutica , Estudios Retrospectivos , Neoplasias Gástricas/fisiopatología
8.
J Radiat Res ; 65(1): 92-99, 2024 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-37996094

RESUMEN

The SyncTraX series enables real-time tumor-tracking radiotherapy through the real-time recognition of a fiducial marker using fluoroscopic images. In this system, the isocenter should be located within approximately 5-7.5 cm from the marker, depending on the version, owing to the limited field of view. If the marker is placed away from the tumor, the isocenter should be shifted toward the marker. This study aimed to investigate stereotactic body radiotherapy (SBRT) outcomes of primary liver tumors treated with SyncTraX in cases where the isocenter was shifted marginally or outside the planning target volume (PTV). Twelve patients with 13 liver tumors were included in the analysis. Their isocenter was shifted toward the marker and was placed marginally or outside the PTV. The prescribed doses were generally 40 Gy in four fractions or 48 Gy in eight fractions. The overall survival (OS) and local control (LC) rates were calculated using the Kaplan-Meier method. All patients completed the scheduled SBRT. The median distance between the fiducial marker and PTV centroid was 56.0 (interquartile range [IQR]: 52.7-66.7) mm. By shifting the isocenter toward the marker, the median distance between the marker and isocenter decreased to 34.0 (IQR: 33.4-39.7) mm. With a median follow-up period of 25.3 (range: 6.9-70.0) months, the 2-year OS and LC rates were 100.0% (95% confidence interval: 100-100). An isocenter shift makes SBRT with SyncTraX feasible in cases where the fiducial marker is distant from the tumor.


Asunto(s)
Neoplasias Hepáticas , Radiocirugia , Radioterapia de Intensidad Modulada , Humanos , Dosificación Radioterapéutica , Estudios Retrospectivos , Neoplasias Hepáticas/radioterapia , Radiocirugia/métodos , Radioterapia de Intensidad Modulada/métodos , Planificación de la Radioterapia Asistida por Computador/métodos
9.
Phys Imaging Radiat Oncol ; 31: 100623, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39224689

RESUMEN

Real-time tumor-tracking volumetric modulated arc therapy (RT-VMAT) enabling beam-gating based on continuous X-ray tracking of the three-dimensional position of internal markers is relevant for moving tumors. Dose-volume characteristics and treatment time were evaluated in ten consecutive patients who underwent liver stereotactic body radiation therapy with RT-VMAT. Target dose conformity and sparing of the stomach and the intestine were improved comparing RT-VMAT with RT-3D conformal radiotherapy. The mean treatment time for each fraction was less than 10 min. RT-VMAT could be effective, especially for targets located adjacent to organs at risk.

10.
J Radiat Res ; 2024 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-39376078

RESUMEN

To assess the interfractional anatomical range variations (ARVs) with beam directions and their impact on dose distribution in intensity modulated proton therapy, we analyzed water equivalent thickness (WET) from 10 patients with pancreatic cancer. The distributions of the interfractional WET difference ($\Delta{\mathrm{WET}}^{\theta }$) across 360° were visualized using polar histograms. Interfractional ARVs were evaluated using the mean absolute error and ΔWET pass rate, indicating the percentage of $\Delta \mathrm{WE}{\mathrm{T}}^{\theta }$ < thresholds. The impact on dose distribution in proton therapy was evaluated based on two treatment plans for 40 Gy(RBE)/5 fractions: 'Plan A', using two beam angles, in which the target was closest to the body surface among four perpendicular directions; and 'Plan B', using two beam angles with small ARVs. Analysis revealed individual variations in angular trends of interfractional ARVs. Three distinct trends were identified: Group 1 exhibited small ARVs around posterior directions; Group 2 exhibited small ARVs except ~60°; Group 3 demonstrated minimal ARVs only ~90°. In dose evaluation, while 150° and 210° were selected in Plan B for 9 out of 10 patients, for the remaining patient, 60° and 90° were chosen. Comparing dose volume histogram parameters for all patients, Plan B significantly reduced target coverage loss while maintaining organ-at-risk sparing comparable to Plan A. These results demonstrated that selecting beam angles with small interfractional ARVs for each patient enhances the robustness of dose distribution, reducing target coverage loss.

11.
Phys Med ; 125: 104507, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39217787

RESUMEN

PURPOSE: To demonstrate the possibility of using a lower imaging rate while maintaining acceptable accuracy by applying motion prediction to minimize the imaging dose in real-time image-guided radiation therapy. METHODS: Time-series of three-dimensional internal marker positions obtained from 98 patients in liver stereotactic body radiation therapy were used to train and test the long-short-term memory (LSTM) network. For real-time imaging, the root mean squared error (RMSE) of the prediction on three-dimensional marker position made by LSTM, the residual motion of the target under respiratory-gated irradiation, and irradiation efficiency were evaluated. In the evaluation of the residual motion, the system-specific latency was assumed to be 100 ms. RESULTS: Except for outliers in the superior-inferior (SI) direction, the median/maximum values of the RMSE for imaging rates of 7.5, 5.0, and 2.5 frames per second (fps) were 0.8/1.3, 0.9/1.6, and 1.2/2.4 mm, respectively. The median/maximum residual motion in the SI direction at an imaging rate of 15.0 fps without prediction of the marker position, which is a typical clinical setting, was 2.3/3.6 mm. For rates of 7.5, 5.0, and 2.5 fps with prediction, the corresponding values were 2.0/2.6, 2.2/3.3, and 2.4/3.9 mm, respectively. There was no significant difference between the irradiation efficiency with and that without prediction of the marker position. The geometrical accuracy at lower frame rates with prediction applied was superior or comparable to that at 15 fps without prediction. In comparison with the current clinical setting for real-time image-guided radiation therapy, which uses an imaging rate of 15.0 fps without prediction, it may be possible to reduce the imaging dose by half or more. CONCLUSIONS: Motion prediction can effectively lower the frame rate and minimize the imaging dose in real-time image-guided radiation therapy.


Asunto(s)
Movimiento , Radiocirugia , Radioterapia Guiada por Imagen , Humanos , Radioterapia Guiada por Imagen/métodos , Radiocirugia/métodos , Dosis de Radiación , Factores de Tiempo , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/diagnóstico por imagen , Dosificación Radioterapéutica , Redes Neurales de la Computación , Memoria a Corto Plazo/efectos de la radiación
12.
J Radiat Res ; 65(1): 63-70, 2024 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-37952082

RESUMEN

The objective of this study was to determine the outcomes of radical radiotherapy for early glottic squamous cell carcinoma (EGSCC) with the policy of increasing the fraction size during radiotherapy when the overall treatment time (OTT) was expected to be prolonged. Patients diagnosed with clinical T1-2N0M0 EGSCC, who were treated with radical radiotherapy between 2008 and 2019 at Hokkaido University Hospital, were included. Patients received 66 Gy in 33 fractions for T1 disease and 70 Gy in 35 fractions for T2 disease as our standard regimen (usual group [UG]). If the OTT was expected to extend for >1 week, the dose fraction size was increased from 2.0 to 2.5 Gy from the beginning or during radiotherapy (adjusted group [AG]). At this time, we performed a statistical analysis between UG and AG. In total, 116 patients were identified, and the treatment schedules of 29 patients were adjusted. The median follow-up was 60.9 months. In the T1 group, the cumulative 5-year local failure rate was 12.0% in the AG and 15.4% in the UG, and in the T2 group, the rate was 40.7% in the AG and 25.3% in the UG. There were no significant differences between the AG and UG. Similarly, no significant differences were observed for overall survival and progression-free survival rates. Our single-institutional retrospective analysis of EGSCC patients suggested that a method of adjusting the radiotherapy schedule to increase fraction size from the beginning or during the course may be effective in maintaining treatment outcomes.


Asunto(s)
Carcinoma de Células Escamosas , Neoplasias de Cabeza y Cuello , Neoplasias Laríngeas , Humanos , Estudios Retrospectivos , Neoplasias Laríngeas/radioterapia , Neoplasias Laríngeas/patología , Dosificación Radioterapéutica , Carcinoma de Células Escamosas de Cabeza y Cuello/patología , Estadificación de Neoplasias
13.
Liver Cancer ; 13(2): 161-168, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38751552

RESUMEN

Introduction: Intrahepatic cholangiocarcinoma (ICC) can be treated with chemotherapy in unresectable cases, but outcomes are poor. Proton beam therapy (PBT) may provide an alternative treatment and has good dose concentration that may improve local control. Methods: Fifty-nine patients who received initial PBT for ICC from May 2016 to June 2018 at nine centers were included in the study. The treatment protocol was based on the policy of the Japanese Society for Radiation Oncology. Forty patients received 72.6-76 Gy (RBE) in 20-22 fr, 13 received 74.0-76.0 Gy (RBE) in 37-38 fr, and 6 received 60-70.2 Gy (RBE) in 20-30 fr. Overall survival (OS) and progression-free survival (PFS) were estimated by Kaplan-Meier analysis. Results: The 59 patients (35 men, 24 women; median age: 71 years; range: 41-91 years) had PS of 0 (n = 47), 1 (n = 10), and 2 (n = 2). Nine patients had hepatitis and all 59 cases were considered inoperable. The Child-Pugh class was A (n = 46), B (n = 7), and unknown (n = 6); the median maximum tumor diameter was 5.0 cm (range 2.0-15.2 cm); and the clinical stage was I (n = 12), II (n = 19), III (n = 10), and IV (n = 18). At the last follow-up, 17 patients were alive (median follow-up: 36.7 months; range: 24.1-49.9 months) and 42 had died. The median OS was 21.7 months (95% CI: 14.8-34.4 months). At the last follow-up, 37 cases had recurrence, including 10 with local recurrence. The median PFS was 7.5 months (95% CI: 6.1-11.3 months). In multivariable analyses, Child-Pugh class was significantly associated with OS and PFS, and Child-Pugh class and hepatitis were significantly associated with local recurrence. Four patients (6.8%) had late adverse events of grade 3 or higher. Conclusion: PBT gives favorable treatment outcomes for unresectable ICC without distant metastasis and may be particularly effective in cases with large tumors.

14.
J Radiat Res ; 65(3): 369-378, 2024 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-38499489

RESUMEN

This retrospective treatment-planning study was conducted to determine whether intensity-modulated proton therapy with robust optimization (ro-IMPT) reduces the risk of acute hematologic toxicity (H-T) and acute and late gastrointestinal toxicity (GI-T) in postoperative whole pelvic radiotherapy for gynecologic malignancies when compared with three-dimensional conformal radiation therapy (3D-CRT), intensity-modulated X-ray (IMXT) and single-field optimization proton beam (SFO-PBT) therapies. All plans were created for 13 gynecologic-malignancy patients. The prescribed dose was 45 GyE in 25 fractions for 95% planning target volume in 3D-CRT, IMXT and SFO-PBT plans and for 99% clinical target volume (CTV) in ro-IMPT plans. The normal tissue complication probability (NTCP) of each toxicity was used as an in silico surrogate marker. Median estimated NTCP values for acute H-T and acute and late GI-T were 0.20, 0.94 and 0.58 × 10-1 in 3D-CRT; 0.19, 0.65 and 0.24 × 10-1 in IMXT; 0.04, 0.74 and 0.19 × 10-1 in SFO-PBT; and 0.06, 0.66 and 0.15 × 10-1 in ro-IMPT, respectively. Compared with 3D-CRT and IMXT plans, the ro-IMPT plan demonstrated significant reduction in acute H-T and late GI-T. The risk of acute GI-T in ro-IMPT plan is equivalent with IMXT plan. The ro-IMPT plan demonstrated potential clinical benefits for reducing the risk of acute H-T and late GI-T in the treatment of gynecologic malignances by reducing the dose to the bone marrow and bowel bag while maintaining adequate dose coverage to the CTV. Our results indicated that ro-IMPT may reduce acute H-T and late GI-T risk with potentially improving outcomes for postoperative gynecologic-malignancy patients with concurrent chemotherapy.


Asunto(s)
Neoplasias de los Genitales Femeninos , Terapia de Protones , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Femenino , Neoplasias de los Genitales Femeninos/radioterapia , Radioterapia de Intensidad Modulada/efectos adversos , Terapia de Protones/efectos adversos , Pelvis/efectos de la radiación , Traumatismos por Radiación/etiología , Traumatismos por Radiación/prevención & control , Probabilidad , Tracto Gastrointestinal/efectos de la radiación , Persona de Mediana Edad , Periodo Posoperatorio , Órganos en Riesgo/efectos de la radiación , Anciano , Dosificación Radioterapéutica , Estudios Retrospectivos , Adulto
15.
Radiat Oncol J ; 42(1): 74-82, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38549386

RESUMEN

PURPOSE: To investigate the clinical significance of adaptive radiotherapy (ART) in locally advanced nasopharyngeal carcinoma treated with intensity-modulated radiotherapy (IMRT). MATERIALS AND METHODS: Eligible patients were treated with concurrent chemoradiotherapy using IMRT. Planning computed tomography in ART was performed during radiotherapy, and replanning was performed. Since ART was started in May 2011 (ART group), patients who were treated without ART up to April 2011 (non-ART group) were used as the historical control. The Kaplan-Meier method was used to calculate overall survival (OS), locoregional recurrence-free survival (LRFS), progression-free survival (PFS), and distant metastasis-free survival (DMFS). LRFS for the primary tumor (LRFS_P) and regional lymph node (LRFS_LN) were also studied for more detailed analysis. Statistical significance was evaluated using the log-rank test for survival. RESULTS: The ART group tended to have higher radiation doses. The median follow-up period was 127 months (range, 10 to 211 months) in the non-ART group and 61.5 months (range, 5 to 129 months) in the ART group. Compared to the non-ART group, the ART group showed significantly higher 5-year PFS (53.8% vs. 81.3%, p = 0.015) and LRFS (61.2% vs. 85.3%, p = 0.024), but not OS (80.7% vs. 80.8%, p = 0.941) and DMFS (84.6% vs. 92.7%, p = 0.255). Five-year LRFS_P was higher in the ART group (61.3% vs. 90.6%, p = 0.005), but LRFS_LN did not show a significant difference (91.9% vs. 96.2%, p = 0.541). CONCLUSION: Although there were differences in the patient backgrounds between the two groups, this study suggests the potential effectiveness of ART in improving locoregional control, especially in the primary tumor.

16.
Adv Radiat Oncol ; 9(5): 101464, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38560429

RESUMEN

Purpose: In real-time image-gated spot-scanning proton therapy (RGPT), the dose distribution is distorted by gold fiducial markers placed in the prostate. Distortion can be suppressed by using small markers and more than 2 fields, but additional fields may increase the dose to organs at risk. Therefore, we conducted a prospective study to evaluate the safety and short-term clinical outcome of RGPT for prostate cancer. Methods and Materials: Based on the previously reported frequency of early adverse events (AE) and the noninferiority margin of 10%, the required number of cases was calculated to be 43 using the one-sample binomial test by the Southwest Oncology Group statistical tools with the one-sided significance level of 2.5% and the power 80%. Patients with localized prostate cancer were enrolled and 3 to 4 pure gold fiducial markers of 1.5-mm diameter were inserted in the prostate. The prescribed dose was 70 Gy(relative biologic effectiveness) in 30 fractions, and treatment was performed with 3 fields from the left, right, and the back, or 4 fields from either side of slightly anterior and posterior oblique fields. The primary endpoint was the frequency of early AE (≥grade 2) and the secondary endpoint was the biochemical relapse-free survival rate and the frequency of late AE. Results: Forty-five cases were enrolled between 2015 and 2017, and all patients completed the treatment protocol. The median follow-up period was 63.0 months. The frequency of early AE (≥grade 2) was observed in 4 cases (8.9%), therefore the noninferiority was verified. The overall 5-year biochemical relapse-free survival rate was 88.9%. As late AE, grade 2 rectal bleeding was observed in 8 cases (17.8%). Conclusions: The RGPT for prostate cancer with 1.5-mm markers and 3- or 4- fields was as safe as conventional proton therapy in early AE, and its efficacy was comparable with previous studies.

17.
Int J Radiat Oncol Biol Phys ; 118(3): 725-733, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-37778422

RESUMEN

PURPOSE: A prospective multicenter registry study was started May 2016 in Japan to evaluate the efficacy and safety of proton beam therapy (PBT) for hepatocellular carcinoma (HCC). METHODS AND MATERIALS: Patients who received PBT for HCC from May 2016 to June 2018 were registered in the database of the Particle Beam Therapy Committee and Subcommittee of the Japanese Society for Radiation Oncology. Overall survival (OS), progression-free survival (PFS), and local recurrence were evaluated. RESULTS: Of the 755 registered patients, 576 with initial PBT and no duplicate cancer were evaluated. At final follow-up, 322 patients were alive and 254 had died. The median follow-up period for survivors was 39 months (0-58 months). The median OS time of the 576 patients was 48.8 months (95% CI, 42.0-55.6 months) and the 1-, 2-, 3-, and 4-year OS rates were 83.8% (95% CI, 80.5%-86.6%), 68.5% (64.5%-72.2%), 58.2% (53.9%-62.2%), and 50.1% (44.9%-55.0%), respectively. Recurrence was observed in 332 patients, including local recurrence in 45 patients. The median PFS time was 14.7 months (95% CI, 12.4-17.0 months) and the 1-, 2-, 3-, and 4-year PFS rates were 55.2% (95% CI, 51.0%-59.2%), 37.5% (33.5%-41.5%), 30.2% (26.3%-34.2%), and 22.8% (18.5%-27.4%), respectively. The 1-, 2-, 3-, and 4-year OS rates were significantly higher for tumor size <5 versus 5 to 10 cm (P < .001) and <5 versus ≥10 cm (P < .001); Child-Pugh score A/B versus C (P < .001); and distance of the tumor from the gastrointestinal tract <1 versus 1 to 2 cm (P < .008) and <1 versus >2 cm (P < .001). At final follow-up, 27 patients (4.7%) had late adverse events of grade 3 or higher, with liver failure (n = 7), and dermatitis (n = 7) being most common. CONCLUSIONS: This multicenter prospective data registry indicated that PBT for HCC gives good therapeutic effects (3-year local control rate of 90%) with a low risk of severe late adverse events.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Terapia de Protones , Humanos , Carcinoma Hepatocelular/radioterapia , Terapia de Protones/efectos adversos , Terapia de Protones/métodos , Japón , Neoplasias Hepáticas/radioterapia , Sistema de Registros
18.
J Radiat Res ; 65(5): 701-711, 2024 Sep 24.
Artículo en Inglés | MEDLINE | ID: mdl-39162649

RESUMEN

Purpose of this study is to evaluate patient characteristics, treatments and outcomes in bone metastasis radiotherapy practice. Patients for whom radiotherapy for bone metastasis was planned at 26 institutions in Japan between December 2020 and March 2021 were consecutively registered in this prospective, observational study. Study measures included patient characteristics, pain relief, skeletal-related events (SREs), overall survival and incidence of radiation-related adverse events. Pain was evaluated using a numerical rating scale (NRS) from 0 to 10. Irradiated dose was analyzed by the biologically effective dose (BED) assuming α/ß = 10. Overall, 232 patients were registered; 224 patients and 302 lesions were fully analyzed. Eastern Cooperative Oncology Group Performance Status was 0/1/2/3/4 in 23%/38%/22%/13%/4%; 59% of patients had spinal metastases and 84% had painful lesions (NRS ≥ 2). BED was <20 Gy (in 27%), 20-30 Gy (24%), 30-40 Gy (36%) and ≥ 40 Gy (13%); 9% of patients were treated by stereotactic body radiotherapy. Grade 3 adverse events occurred in 4% and no grade 4-5 toxicity was reported. Pain relief was achieved in 52% at 2 months. BED is not related to pain relief. The cumulative incidence of SREs was 6.5% (95% confidence interval (CI) 3.1-9.9) at 6 months; no factors were significantly associated with SREs. With spinal lesions, 18% of patients were not ambulatory at baseline and 50% of evaluable patients in this group could walk at 2 months. The 6-month overall survival rate was 70.2% (95% CI 64.2-76.9%). In conclusion, we report real-world details of radiotherapy in bone metastasis.


Asunto(s)
Neoplasias Óseas , Humanos , Masculino , Femenino , Neoplasias Óseas/radioterapia , Neoplasias Óseas/secundario , Anciano , Estudios Prospectivos , Persona de Mediana Edad , Anciano de 80 o más Años , Adulto , Resultado del Tratamiento , Japón , Dolor/radioterapia , Dolor/etiología , Dosificación Radioterapéutica
19.
J Radiat Res ; 64(6): 926-932, 2023 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-37697668

RESUMEN

A nationwide multicenter cohort study on particle therapy was launched by the Japanese Society for Radiation Oncology in Japan in May 2016. We analyzed the outcome of proton beam therapy (PBT) for liver oligometastasis of esophagogastric cancers. Cases in which PBT was performed at all PBT facilities in Japan between May 2016 and February 2019 were enrolled. The patients were selected based on the following criteria: controlled primary cancer, liver recurrence without extrahepatic tumors and no more than three liver lesions. Twenty-two males and two females with a median age of 69 (range, 52-80) years and 35 lesions were included. This study included 6 patients with esophageal and 18 patients with gastric cancer. The median lesion size, fraction size and biological effective dose (BED)10 were 32 (7-104) mm, 3.8 gray (relative biological effect)/fractions (Gy (RBE)/fr) (2-8 Gy (RBE)/fr) and 96.9 (88.8-115.2) Gy, respectively. The median follow-up period was 18 (4-47) months. The 1-, 2- and 3-year overall survival (OS) rates were 75, 51.8 and 45.3%, respectively, and the median OS was 25.3 months. The 1-, 2- and 3-year cumulative local recurrence (LR) rates were 3, 6 and 6%, respectively. Patients' age (P < 0.01), performance status (P = 0.017) and tumor size (P = 0.024) were significant OS-related factors. No Grade 3 or higher adverse events (AEs) were observed. Owing to the low incidence of AEs and the low LR cumulative incidence, PBT is a feasible option for liver oligometastasis of esophagogastric cancers.


Asunto(s)
Neoplasias Esofágicas , Terapia de Protones , Neoplasias Gástricas , Masculino , Femenino , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Terapia de Protones/efectos adversos , Neoplasias Esofágicas/radioterapia , Neoplasias Gástricas/radioterapia , Estudios de Cohortes , Pueblos del Este de Asia , Hígado
20.
Med Phys ; 50(2): 993-999, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36427355

RESUMEN

PURPOSE: To quantitatively evaluate the achievable performance of volumetric imaging based on lung motion modeling by principal component analysis (PCA). METHODS: In volumetric imaging based on PCA, internal deformation was represented as a linear combination of the eigenvectors derived by PCA of the deformation vector fields evaluated from patient-specific four-dimensional-computed tomography (4DCT) datasets. The volumetric image was synthesized by warping the reference CT image with a deformation vector field which was evaluated using optimal principal component coefficients (PCs). Larger PCs were hypothesized to reproduce deformations larger than those included in the original 4DCT dataset. To evaluate the reproducibility of PCA-reconstructed volumetric images synthesized to be close to the ground truth as possible, mean absolute error (MAE), structure similarity index measure (SSIM) and discrepancy of diaphragm position were evaluated using 22 4DCT datasets of nine patients. RESULTS: Mean MAE and SSIM values for the PCA-reconstructed volumetric images were approximately 80 HU and 0.88, respectively, regardless of the respiratory phase. In most test cases including the data of which motion range was exceeding that of the modeling data, the positional error of diaphragm was less than 5 mm. The results suggested that large deformations not included in the modeling 4DCT dataset could be reproduced. Furthermore, since the first PC correlated with the displacement of the diaphragm position, the first eigenvector became the dominant factor representing the respiration-associated deformations. However, other PCs did not necessarily change with the same trend as the first PC, and no correlation was observed between the coefficients. Hence, randomly allocating or sampling these PCs in expanded ranges may be applicable to reasonably generate an augmented dataset with various deformations. CONCLUSIONS: Reasonable accuracy of image synthesis comparable to those in the previous research were shown by using clinical data. These results indicate the potential of PCA-based volumetric imaging for clinical applications.


Asunto(s)
Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Análisis de Componente Principal , Reproducibilidad de los Resultados , Movimiento (Física) , Diagnóstico por Imagen , Respiración , Tomografía Computarizada Cuatridimensional/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA