Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 680
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
NMR Biomed ; : e5173, 2024 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-38783837

RESUMEN

PURPOSE: The purpose of this work is to apply multi-echo spin- and gradient-echo (SAGE) echo-planar imaging (EPI) combined with a navigator-based (NAV) prospective motion compensation method for a quantitative liver blood oxygen level dependent (BOLD) measurement with a breath-hold (BH) task. METHODS: A five-echo SAGE sequence was developed to quantitatively measure T2 and T2* to depict function with sufficient signal-to-noise ratio, spatial resolution and sensitivity to BOLD changes induced by the BH task. To account for respiratory motion, a navigator was employed in the form of a single gradient-echo projection readout, located at the diaphragm along the inferior-superior direction. Prior to each transverse imaging slice of the spin-echo EPI-based readouts, navigator acquisition and fat suppression were incorporated. Motion data was obtained from the navigator and transmitted back to the sequence, allowing real-time adjustments to slice positioning. Six healthy volunteers and three patients with liver carcinoma were included in this study. Quantitative T2 and T2* were calculated at each time point of the BH task. Parameters of t value from first-level analysis using a general linear model and hepatovascular reactivity (HVR) of Echo1, T2 and T2* were calculated. RESULTS: The motion caused by respiratory activity was successfully compensated using the navigator signal. The average changes of T2 and T2* during breath-hold were about 1% and 0.7%, respectively. With the help of NAV prospective motion compensation whole liver t values could be obtained without motion artifacts. The quantified liver T2 (34.7 ± 0.7 ms) and T2* (29 ± 1.2 ms) values agreed with values from literature. In healthy volunteers, the distribution of statistical t value and HVR was homogeneous throughout the whole liver. In patients with liver carcinoma, the distribution of t value and HVR was inhomogeneous due to metastases or therapy. CONCLUSIONS: This study demonstrates the feasibility of using a NAV prospective motion compensation technique in conjunction with five-echo SAGE EPI for the quantitative measurement of liver BOLD with a BH task.

2.
Eur Radiol ; 34(7): 4379-4392, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38150075

RESUMEN

OBJECTIVES: To quantify regional manifestations related to COPD as anomalies from a modeled distribution of normal-appearing lung on chest CT using a deep learning (DL) approach, and to assess its potential to predict disease severity. MATERIALS AND METHODS: Paired inspiratory/expiratory CT and clinical data from COPDGene and COSYCONET cohort studies were included. COPDGene data served as training/validation/test data sets (N = 3144/786/1310) and COSYCONET as external test set (N = 446). To differentiate low-risk (healthy/minimal disease, [GOLD 0]) from COPD patients (GOLD 1-4), the self-supervised DL model learned semantic information from 50 × 50 × 50 voxel samples from segmented intact lungs. An anomaly detection approach was trained to quantify lung abnormalities related to COPD, as regional deviations. Four supervised DL models were run for comparison. The clinical and radiological predictive power of the proposed anomaly score was assessed using linear mixed effects models (LMM). RESULTS: The proposed approach achieved an area under the curve of 84.3 ± 0.3 (p < 0.001) for COPDGene and 76.3 ± 0.6 (p < 0.001) for COSYCONET, outperforming supervised models even when including only inspiratory CT. Anomaly scores significantly improved fitting of LMM for predicting lung function, health status, and quantitative CT features (emphysema/air trapping; p < 0.001). Higher anomaly scores were significantly associated with exacerbations for both cohorts (p < 0.001) and greater dyspnea scores for COPDGene (p < 0.001). CONCLUSION: Quantifying heterogeneous COPD manifestations as anomaly offers advantages over supervised methods and was found to be predictive for lung function impairment and morphology deterioration. CLINICAL RELEVANCE STATEMENT: Using deep learning, lung manifestations of COPD can be identified as deviations from normal-appearing chest CT and attributed an anomaly score which is consistent with decreased pulmonary function, emphysema, and air trapping. KEY POINTS: • A self-supervised DL anomaly detection method discriminated low-risk individuals and COPD subjects, outperforming classic DL methods on two datasets (COPDGene AUC = 84.3%, COSYCONET AUC = 76.3%). • Our contrastive task exhibits robust performance even without the inclusion of expiratory images, while voxel-based methods demonstrate significant performance enhancement when incorporating expiratory images, in the COPDGene dataset. • Anomaly scores improved the fitting of linear mixed effects models in predicting clinical parameters and imaging alterations (p < 0.001) and were directly associated with clinical outcomes (p < 0.001).


Asunto(s)
Aprendizaje Profundo , Enfermedad Pulmonar Obstructiva Crónica , Índice de Severidad de la Enfermedad , Tomografía Computarizada por Rayos X , Humanos , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico por imagen , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Masculino , Femenino , Tomografía Computarizada por Rayos X/métodos , Persona de Mediana Edad , Anciano , Valor Predictivo de las Pruebas , Pulmón/diagnóstico por imagen , Estudios de Cohortes
3.
Eur Radiol ; 2024 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-38345607

RESUMEN

OBJECTIVES: A prospective, multi-centre study to evaluate concordance of morphologic lung MRI and CT in chronic obstructive pulmonary disease (COPD) phenotyping for airway disease and emphysema. METHODS: A total of 601 participants with COPD from 15 sites underwent same-day morpho-functional chest MRI and paired inspiratory-expiratory CT. Two readers systematically scored bronchial wall thickening, bronchiectasis, centrilobular nodules, air trapping and lung parenchyma defects in each lung lobe and determined COPD phenotype. A third reader acted as adjudicator to establish consensus. Inter-modality and inter-reader agreement were assessed using Cohen's kappa (im-κ and ir-κ). RESULTS: The mean combined MRI score for bronchiectasis/bronchial wall thickening was 4.5/12 (CT scores, 2.2/12 for bronchiectasis and 6/12 for bronchial wall thickening; im-κ, 0.04-0.3). Expiratory right/left bronchial collapse was observed in 51 and 47/583 on MRI (62 and 57/599 on CT; im-κ, 0.49-0.52). Markers of small airways disease on MRI were 0.15/12 for centrilobular nodules (CT, 0.34/12), 0.94/12 for air trapping (CT, 0.9/12) and 7.6/12 for perfusion deficits (CT, 0.37/12 for mosaic attenuation; im-κ, 0.1-0.41). The mean lung defect score on MRI was 1.3/12 (CT emphysema score, 5.8/24; im-κ, 0.18-0.26). Airway-/emphysema/mixed COPD phenotypes were assigned in 370, 218 and 10 of 583 cases on MRI (347, 218 and 34 of 599 cases on CT; im-κ, 0.63). For all examined features, inter-reader agreement on MRI was lower than on CT. CONCLUSION: Concordance of MRI and CT for phenotyping of COPD in a multi-centre setting was substantial with variable inter-modality and inter-reader concordance for single diagnostic key features. CLINICAL RELEVANCE STATEMENT: MRI of lung morphology may well serve as a radiation-free imaging modality for COPD in scientific and clinical settings, given that its potential and limitations as shown here are carefully considered. KEY POINTS: • In a multi-centre setting, MRI and CT showed substantial concordance for phenotyping of COPD (airway-/emphysema-/mixed-type). • Individual features of COPD demonstrated variable inter-modality concordance with features of pulmonary hypertension showing the highest and bronchiectasis showing the lowest concordance. • For all single features of COPD, inter-reader agreement was lower on MRI than on CT.

4.
Langenbecks Arch Surg ; 409(1): 167, 2024 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-38809279

RESUMEN

PURPOSE: Pancreatic cancer (PDAC) is characterized by infiltrative, spiculated tumor growth into the surrounding non-neoplastic tissue. Clinically, its diagnosis is often established by magnetic resonance imaging (MRI). At the invasive margin, tumor buds can be detected by histology, an established marker associated with poor prognosis in different types of tumors. METHODS: We analyzed PDAC by determining the degree of tumor spiculation on T2-weighted MRI using a 3-tier grading system. The grade of spiculation was correlated with the density of tumor buds quantified in histological sections of the respective surgical specimen according to the guidelines of the International Tumor Budding Consensus Conference (n = 28 patients). RESULTS: 64% of tumors revealed intermediate to high spiculation on MRI. In over 90% of cases, tumor buds were detected. We observed a significant positive rank correlation between the grade of radiological tumor spiculation and the histopathological number of tumor buds (rs = 0.745, p < 0.001). The number of tumor buds was not significantly associated with tumor stage, presence of lymph node metastases, or histopathological grading (p ≥ 0.352). CONCLUSION: Our study identifies a readily available radiological marker for non-invasive estimation of tumor budding, as a correlate for infiltrative tumor growth. This finding could help to identify PDAC patients who might benefit from more extensive peripancreatic soft tissue resection during surgery or stratify patients for personalized therapy concepts.


Asunto(s)
Imagen por Resonancia Magnética , Márgenes de Escisión , Invasividad Neoplásica , Neoplasias Pancreáticas , Humanos , Neoplasias Pancreáticas/patología , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/cirugía , Masculino , Femenino , Anciano , Persona de Mediana Edad , Invasividad Neoplásica/patología , Carcinoma Ductal Pancreático/patología , Carcinoma Ductal Pancreático/diagnóstico por imagen , Carcinoma Ductal Pancreático/cirugía , Anciano de 80 o más Años , Estudios Retrospectivos , Estadificación de Neoplasias , Clasificación del Tumor , Pancreatectomía
5.
BMC Pulm Med ; 24(1): 103, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38424530

RESUMEN

BACKGROUND: Randomized controlled trials described beneficial effects of inhaled triple therapy (LABA/LAMA/ICS) in patients with chronic obstructive pulmonary disease (COPD) and high risk of exacerbations. We studied whether such effects were also detectable under continuous treatment in a retrospective observational setting. METHODS: Data from baseline and 18-month follow-up of the COPD cohort COSYCONET were used, including patients categorized as GOLD groups C/D at both visits (n = 258). Therapy groups were defined as triple therapy at both visits (triple always, TA) versus its complement (triple not always, TNA). Comparisons were performed via multiple regression analysis, propensity score matching and inverse probability weighting to adjust for differences between groups. For this purpose, variables were divided into predictors of therapy and outcomes. RESULTS: In total, 258 patients were eligible (TA: n = 162, TNA: n = 96). Without adjustments, TA patients showed significant (p < 0.05) impairments regarding lung function, quality of life and symptom burden. After adjustments, most differences in outcomes were no more significant. Total direct health care costs were reduced but still elevated, with inpatient costs much reduced, while costs of total and respiratory medication only slightly changed. CONCLUSION: Without statistical adjustment, patients with triple therapy showed multiple impairments as well as elevated treatment costs. After adjusting for differences between treatment groups, differences were reduced. These findings are compatible with beneficial effects of triple therapy under continuous, long-term treatment, but also demonstrate the limitations encountered in the comparison of controlled intervention studies with observational studies in patients with severe COPD using different types of devices and compounds.


Asunto(s)
Enfermedad Pulmonar Obstructiva Crónica , Humanos , Administración por Inhalación , Corticoesteroides/uso terapéutico , Agonistas de Receptores Adrenérgicos beta 2/uso terapéutico , Broncodilatadores/uso terapéutico , Costo de Enfermedad , Quimioterapia Combinada , Antagonistas Muscarínicos , Calidad de Vida , Estudios Retrospectivos
6.
J Appl Clin Med Phys ; 25(4): e14300, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38386967

RESUMEN

PURPOSE: The aim of this study was to characterize a second-generation wide-detector dual-layer spectral computed tomography (CT) system for material quantification accuracy, acquisition parameter and patient size dependencies, and tissue characterization capabilities. METHODS: A phantom with multiple tissue-mimicking and material-specific inserts was scanned with a dual-layer spectral detector CT using different tube voltages, collimation widths, radiation dose levels, and size configurations. Accuracy of iodine density maps and virtual monoenergetic images (MonoE) were investigated. Additionally, differences between conventional and MonoE 70 keV images were calculated to evaluate acquisition parameter and patient size dependencies. To demonstrate material quantification and differentiation, liver-mimicking inserts with adipose and iron were analyzed with a two-base decomposition utilizing MonoE 50 and 150 keV, and root mean square error (RMSE) for adipose and iron content was reported. RESULTS: Measured inserts exhibited quantitative accuracy across a wide range of MonoE levels. MonoE 70 keV images demonstrated reduced dependence compared to conventional images for phantom size (1 vs. 27 HU) and acquisition parameters, particularly tube voltage (4 vs. 37 HU). Iodine density quantification was successful with errors ranging from -0.58 to 0.44 mg/mL. Similarly, inserts with different amounts of adipose and iron were differentiated, and the small deviation in values within inserts corresponded to a RMSE of 3.49 ± 1.76% and 1.67 ± 0.84 mg/mL for adipose and iron content, respectively. CONCLUSION: The second-generation dual-layer CT enables acquisition of quantitatively accurate spectral data without compromises from differences in patient size and acquisition parameters.


Asunto(s)
Yodo , Tomografía Computarizada por Rayos X , Humanos , Relación Señal-Ruido , Tomografía Computarizada por Rayos X/métodos , Fantasmas de Imagen , Obesidad , Hierro
7.
Zentralbl Chir ; 149(1): 96-115, 2024 Feb.
Artículo en Alemán | MEDLINE | ID: mdl-37816386

RESUMEN

The process of implementing early detection of lung cancer with low-dose CT (LDCT) in Germany has gained significant momentum in recent years. It is expected that the ordinance of the Federal Ministry for the Environment, Nature Conservation, Nuclear Safety and Consumer Protection (BMUV) on early detection of lung cancer, which has been commented on by the professional societies, will come into effect by the end of 2023. Based on this regulation, the Federal Joint Committee (G-BA) will set up a program for early lung cancer detection with LDCT in the near future. In this position paper, the specialist societies involved in lung cancer screening present concrete cornerstones for a uniform, structured and quality-assured early detection program for lung cancer in Germany to make a constructive contribution to this process.


Asunto(s)
Detección Precoz del Cáncer , Neoplasias Pulmonares , Humanos , Tomografía Computarizada por Rayos X , Neoplasias Pulmonares/diagnóstico por imagen , Alemania , Sociedades Médicas , Tamizaje Masivo
8.
Pneumologie ; 78(1): 15-34, 2024 Jan.
Artículo en Alemán | MEDLINE | ID: mdl-37816379

RESUMEN

The process of implementing early detection of lung cancer with low-dose CT (LDCT) in Germany has gained significant momentum in recent years. It is expected that the ordinance of the Federal Ministry for the Environment, Nature Conservation, Nuclear Safety and Consumer Protection (BMUV) on early detection of lung cancer, which has been commented on by the professional societies, will come into effect by the end of 2023. Based on this regulation, the Federal Joint Committee (G-BA) will set up a program for early lung cancer detection with LDCT in the near future. In this position paper, the specialist societies involved in lung cancer screening present concrete cornerstones for a uniform, structured and quality-assured early detection program for lung cancer in Germany to make a constructive contribution to this process.


Asunto(s)
Detección Precoz del Cáncer , Neoplasias Pulmonares , Humanos , Tomografía Computarizada por Rayos X , Neoplasias Pulmonares/diagnóstico por imagen , Factores de Riesgo , Alemania , Tamizaje Masivo
9.
Radiology ; 308(3): e231362, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37724963

RESUMEN

Background The latest large language models (LLMs) solve unseen problems via user-defined text prompts without the need for retraining, offering potentially more efficient information extraction from free-text medical records than manual annotation. Purpose To compare the performance of the LLMs ChatGPT and GPT-4 in data mining and labeling oncologic phenotypes from free-text CT reports on lung cancer by using user-defined prompts. Materials and Methods This retrospective study included patients who underwent lung cancer follow-up CT between September 2021 and March 2023. A subset of 25 reports was reserved for prompt engineering to instruct the LLMs in extracting lesion diameters, labeling metastatic disease, and assessing oncologic progression. This output was fed into a rule-based natural language processing pipeline to match ground truth annotations from four radiologists and derive performance metrics. The oncologic reasoning of LLMs was rated on a five-point Likert scale for factual correctness and accuracy. The occurrence of confabulations was recorded. Statistical analyses included Wilcoxon signed rank and McNemar tests. Results On 424 CT reports from 424 patients (mean age, 65 years ± 11 [SD]; 265 male), GPT-4 outperformed ChatGPT in extracting lesion parameters (98.6% vs 84.0%, P < .001), resulting in 96% correctly mined reports (vs 67% for ChatGPT, P < .001). GPT-4 achieved higher accuracy in identification of metastatic disease (98.1% [95% CI: 97.7, 98.5] vs 90.3% [95% CI: 89.4, 91.0]) and higher performance in generating correct labels for oncologic progression (F1 score, 0.96 [95% CI: 0.94, 0.98] vs 0.91 [95% CI: 0.89, 0.94]) (both P < .001). In oncologic reasoning, GPT-4 had higher Likert scale scores for factual correctness (4.3 vs 3.9) and accuracy (4.4 vs 3.3), with a lower rate of confabulation (1.7% vs 13.7%) than ChatGPT (all P < .001). Conclusion When using user-defined prompts, GPT-4 outperformed ChatGPT in extracting oncologic phenotypes from free-text CT reports on lung cancer and demonstrated better oncologic reasoning with fewer confabulations. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Hafezi-Nejad and Trivedi in this issue.


Asunto(s)
Neoplasias Pulmonares , Neoplasias Primarias Secundarias , Humanos , Masculino , Anciano , Estudios Retrospectivos , Neoplasias Pulmonares/diagnóstico por imagen , Minería de Datos , Oncología Médica , Benchmarking , Trastornos de la Memoria
10.
Eur Respir J ; 2023 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-37202154

RESUMEN

Screening for lung cancer with low radiation dose computed tomography (LDCT) has a strong evidence base. The European Council adopted a recommendation in November 2022 that lung cancer screening be implemented using a stepwise approach. The imperative now is to ensure that implementation follows an evidence-based process that delivers clinical and cost effectiveness. This ERS Taskforce was formed to provide a technical standard for a high-quality lung cancer screening program. METHOD: A collaborative group was convened to include members of multiple European societies (see below). Topics were identified during a scoping review and a systematic review of the literature was conducted. Full text was provided to members of the group for each topic. The final document was approved by all members and the ERS Scientific Advisory Committee. RESULTS: Ten topics were identified representing key components of a screening program. The action on findings from the LDCT were not included as they are addressed by separate international guidelines (nodule management and clinical management of lung cancer) and by a linked taskforce (incidental findings). Other than smoking cessation, other interventions that are not part of the core screening process were not included (e.g. pulmonary function measurement). Fifty-three statements were produced and areas for further research identified. CONCLUSION: This European collaborative group has produced a technical standard that is a timely contribution to implementation of LCS. It will serve as a standard that can be used, as recommended by the European Council, to ensure a high quality and effective program.

11.
Eur Respir J ; 62(4)2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37802631

RESUMEN

BACKGROUND: Screening for lung cancer with low radiation dose computed tomography has a strong evidence base, is being introduced in several European countries and is recommended as a new targeted cancer screening programme. The imperative now is to ensure that implementation follows an evidence-based process that will ensure clinical and cost effectiveness. This European Respiratory Society (ERS) task force was formed to provide an expert consensus for the management of incidental findings which can be adapted and followed during implementation. METHODS: A multi-European society collaborative group was convened. 23 topics were identified, primarily from an ERS statement on lung cancer screening, and a systematic review of the literature was conducted according to ERS standards. Initial review of abstracts was completed and full text was provided to members of the group for each topic. Sections were edited and the final document approved by all members and the ERS Science Council. RESULTS: Nine topics considered most important and frequent were reviewed as standalone topics (interstitial lung abnormalities, emphysema, bronchiectasis, consolidation, coronary calcification, aortic valve disease, mediastinal mass, mediastinal lymph nodes and thyroid abnormalities). Other topics considered of lower importance or infrequent were grouped into generic categories, suitable for general statements. CONCLUSIONS: This European collaborative group has produced an incidental findings statement that can be followed during lung cancer screening. It will ensure that an evidence-based approach is used for reporting and managing incidental findings, which will mean that harms are minimised and any programme is as cost-effective as possible.


Asunto(s)
Neoplasias Pulmonares , Guías de Práctica Clínica como Asunto , Humanos , Detección Precoz del Cáncer/métodos , Etiquetas de Secuencia Expresada , Hallazgos Incidentales , Neoplasias Pulmonares/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos
12.
Magn Reson Med ; 90(1): 231-239, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36806110

RESUMEN

PURPOSE: To apply a navigator-based slice-tracking method to prospectively compensate respiratory motion for kidney pseudo-continuous arterial spin labeling (pCASL), using spin-echo (SE) EPI acquisition. METHODS: A single gradient-echo slice selection and projection readout at the location of the diaphragm along the inferior-superior direction was applied as a navigator. Navigator acquisition and fat suppression were inserted before each transverse imaging slice of the readouts of a 2D-SE-EPI-based pCASL sequence. Motion information was calculated after exclusion of the signal saturation in the navigator signal caused by EPI excitations. The motion information was then used to directly adjust the slice positioning in real time. RESULTS: The respiratory motion from the navigator signal was calculated, and slice positioning was changed in real time based on the motion information. We could show that motion compensation reduces kidney movement, and that the coefficients of variation across renal perfusion values were significantly reduced when motion correction was applied. The average reduction of coefficients of variation was approximately 20%, resulting in a more accurate and detailed structure of the respective perfusion maps. CONCLUSIONS: This study demonstrates the feasibility of a navigator-based slice-tracking technique in kidney imaging with a SE-EPI readout pCASL sequence to reduce kidney motion.


Asunto(s)
Arterias , Encéfalo , Marcadores de Spin , Movimiento (Física) , Riñón/diagnóstico por imagen
13.
Eur Radiol ; 33(2): 803-811, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35986773

RESUMEN

OBJECTIVES: Photon-counting detector computed tomography (PCD-CT) is a promising new technique for CT imaging. The aim of the present study was the in vitro comparison of coil-related artifacts in PCD-CT and conventional energy-integrating detector CT (EID-CT) using a comparable standard brain imaging protocol before and after metal artifact reduction (MAR). METHODS: A nidus-shaped rubber latex, resembling an aneurysm of the cerebral arteries, was filled with neurovascular platinum coils and inserted into a brain imaging phantom. Image acquisition and reconstruction were repeatedly performed for PCD-CT and EID-CT (n = 10, respectively) using a standard brain imaging protocol. Moreover, linear interpolation MAR was performed for PCD-CT and EID-CT images. The degree of artifacts was analyzed quantitatively (standard deviation in a donut-shaped region of interest) and qualitatively (5-point scale analysis). RESULTS: Quantitative and qualitative analysis demonstrated a lower degree of metal artifacts in the EID-CT images compared to the total-energy PCD-CT images (e.g., 82.99 ± 7.89 Hounsfield units (HU) versus 90.35 ± 6.28 HU; p < 0.001) with no qualitative difference between the high-energy bin PCD-CT images and the EID-CT images (4.18 ± 0.37 and 3.70 ± 0.64; p = 0.575). After MAR, artifacts were more profoundly reduced in the PCD-CT images compared to the EID-CT images in both analyses (e.g., 2.35 ± 0.43 and 3.18 ± 0.34; p < 0.001). CONCLUSION: PCD-CT in combination with MAR have the potential to provide an improved option for reduction of coil-related artifacts in cerebral imaging in this in vitro study. KEY POINTS: • Photon-counting detector CT produces more artifacts compared to energy-integrating detector CT without metal artifact reduction in cerebral in vitro imaging after neurovascular coil-embolization. • Spectral information of PCD-CT provides the potential for new post-processing techniques, since the coil-related artifacts were lower in PCD-CT images compared to EID-CT images after linear interpolation metal artifact reduction in this in vitro study.


Asunto(s)
Artefactos , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Encéfalo/diagnóstico por imagen , Fantasmas de Imagen , Fotones , Neuroimagen
14.
Eur Radiol ; 33(8): 5568-5577, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36894752

RESUMEN

OBJECTIVES: To evaluate and compare the measurement accuracy of two different computer-aided diagnosis (CAD) systems regarding artificial pulmonary nodules and assess the clinical impact of volumetric inaccuracies in a phantom study. METHODS: In this phantom study, 59 different phantom arrangements with 326 artificial nodules (178 solid, 148 ground-glass) were scanned at 80 kV, 100 kV, and 120 kV. Four different nodule diameters were used: 5 mm, 8 mm, 10 mm, and 12 mm. Scans were analyzed by a deep-learning (DL)-based CAD and a standard CAD system. Relative volumetric errors (RVE) of each system vs. ground truth and the relative volume difference (RVD) DL-based vs. standard CAD were calculated. The Bland-Altman method was used to define the limits of agreement (LOA). The hypothetical impact on LungRADS classification was assessed for both systems. RESULTS: There was no difference between the three voltage groups regarding nodule volumetry. Regarding the solid nodules, the RVE of the 5-mm-, 8-mm-, 10-mm-, and 12-mm-size groups for the DL CAD/standard CAD were 12.2/2.8%, 1.3/ - 2.8%, - 3.6/1.5%, and - 12.2/ - 0.3%, respectively. The corresponding values for the ground-glass nodules (GGN) were 25.6%/81.0%, 9.0%/28.0%, 7.6/20.6%, and 6.8/21.2%. The mean RVD for solid nodules/GGN was 1.3/ - 15.2%. Regarding the LungRADS classification, 88.5% and 79.8% of all solid nodules were correctly assigned by the DL CAD and the standard CAD, respectively. 14.9% of the nodules were assigned differently between the systems. CONCLUSIONS: Patient management may be affected by the volumetric inaccuracy of the CAD systems and hence demands supervision and/or manual correction by a radiologist. KEY POINTS: • The DL-based CAD system was more accurate in the volumetry of GGN and less accurate regarding solid nodules than the standard CAD system. • Nodule size and attenuation have an effect on the measurement accuracy of both systems; tube voltage has no effect on measurement accuracy. • Measurement inaccuracies of CAD systems can have an impact on patient management, which demands supervision by radiologists.


Asunto(s)
Neoplasias Pulmonares , Nódulos Pulmonares Múltiples , Nódulo Pulmonar Solitario , Humanos , Tomografía Computarizada por Rayos X/métodos , Diagnóstico por Computador/métodos , Nódulos Pulmonares Múltiples/diagnóstico por imagen , Fantasmas de Imagen , Radiólogos , Neoplasias Pulmonares/diagnóstico por imagen , Nódulo Pulmonar Solitario/diagnóstico por imagen , Nódulo Pulmonar Solitario/terapia , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Sensibilidad y Especificidad
15.
Eur Radiol ; 33(8): 5557-5567, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36892642

RESUMEN

OBJECTIVES: Quantitative computed tomography (CT) plays an increasingly important role in phenotyping airway diseases. Lung parenchyma and airway inflammation could be quantified by contrast enhancement at CT, but its investigation by multiphasic examinations is limited. We aimed to quantify lung parenchyma and airway wall attenuation in a single contrast-enhanced spectral detector CT acquisition. METHODS: For this cross-sectional retrospective study, 234 lung-healthy patients who underwent spectral CT in four different contrast phases (non-enhanced, pulmonary arterial, systemic arterial, and venous phase) were recruited. Virtual monoenergetic images were reconstructed from 40-160 keV, on which attenuations of segmented lung parenchyma and airway walls combined for 5th-10th subsegmental generations were assessed in Hounsfield Units (HU) by an in-house software. The spectral attenuation curve slope between 40 and 100 keV (λHU) was calculated. RESULTS: Mean lung density was higher at 40 keV compared to that at 100 keV in all groups (p < 0.001). λHU of lung attenuation was significantly higher in the systemic (1.7 HU/keV) and pulmonary arterial phase (1.3 HU/keV) compared to that in the venous phase (0.5 HU/keV) and non-enhanced (0.2 HU/keV) spectral CT (p < 0.001). Wall thickness and wall attenuation were higher at 40 keV compared to those at 100 keV for the pulmonary and systemic arterial phase (p ≤ 0.001). λHU for wall attenuation was significantly higher in the pulmonary arterial (1.8 HU/keV) and systemic arterial (2.0 HU/keV) compared to that in the venous (0.7 HU/keV) and non-enhanced (0.3 HU/keV) phase (p ≤ 0.002). CONCLUSIONS: Spectral CT may quantify lung parenchyma and airway wall enhancement with a single contrast phase acquisition, and may separate arterial and venous enhancement. Further studies are warranted to analyze spectral CT for inflammatory airway diseases. KEY POINTS: • Spectral CT may quantify lung parenchyma and airway wall enhancement with a single contrast phase acquisition. • Spectral CT may separate arterial and venous enhancement of lung parenchyma and airway wall. • The contrast enhancement can be quantified by calculating the spectral attenuation curve slope from virtual monoenergetic images.


Asunto(s)
Hipertensión Pulmonar , Humanos , Estudios Retrospectivos , Estudios Transversales , Tomografía Computarizada por Rayos X/métodos , Programas Informáticos , Medios de Contraste/farmacología , Relación Señal-Ruido , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
16.
Eur Radiol ; 2023 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-38060003

RESUMEN

OBJECTIVES: Lung cancer screening (LCS), using low-dose computed tomography (LDCT), can be more efficient by simultaneously screening for chronic obstructive pulmonary disease (COPD) and cardiovascular disease (CVD), the Big-3 diseases. This study aimed to determine the willingness to participate in (combinations of) Big-3 screening in four European countries and the relative importance of amendable participation barriers. METHODS: An online cross-sectional survey aimed at (former) smokers aged 50-75 years elicited the willingness of individuals to participate in Big-3 screening and used analytical hierarchy processing (AHP) to determine the importance of participation barriers. RESULTS: Respondents were from France (n = 391), Germany (n = 338), Italy (n = 399), and the Netherlands (n = 342), and consisted of 51.2% men. The willingness to participate in screening was marginally influenced by the diseases screened for (maximum difference of 3.1%, for Big-3 screening (73.4%) vs. lung cancer and COPD screening (70.3%)) and by country (maximum difference of 3.7%, between France (68.5%) and the Netherlands (72.3%)). The largest effect on willingness to participate was personal perceived risk of lung cancer. The most important barriers were the missed cases during screening (weight 0.19) and frequency of screening (weight 0.14), while diseases screened for (weight 0.11) ranked low. CONCLUSIONS: The difference in willingness to participate in LCS showed marginal increase with inclusion of more diseases and limited variation between countries. A marginal increase in participation might result in a marginal additional benefit of Big-3 screening. The amendable participation barriers are similar to previous studies, and the new criterion, diseases screened for, is relatively unimportant. CLINICAL RELEVANCE STATEMENT: Adding diseases to combination screening modestly improves participation, driven by personal perceived risk. These findings guide program design and campaigns for lung cancer and Big-3 screening. Benefits of Big-3 screening lie in long-term health and economic impact, not participation increase. KEY POINTS: • It is unknown whether or how combination screening might affect participation. • The addition of chronic obstructive pulmonary disease and cardiovascular disease to lung cancer screening resulted in a marginal increase in willingness to participate. • The primary determinant influencing individuals' engagement in such programs is their personal perceived risk of the disease.

17.
Eur Radiol ; 33(6): 3908-3917, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36538071

RESUMEN

OBJECTIVES: To assess the value of quantitative computed tomography (QCT) of the whole lung and nodule-bearing lobe regarding pulmonary nodule malignancy risk estimation. METHODS: A total of 251 subjects (median [IQR] age, 65 (57-73) years; 37% females) with pulmonary nodules on non-enhanced thin-section CT were retrospectively included. Twenty percent of the nodules were malignant, the remainder benign either histologically or at least 1-year follow-up. CT scans were subjected to in-house software, computing parameters such as mean lung density (MLD) or peripheral emphysema index (pEI). QCT variable selection was performed using logistic regression; selected variables were integrated into the Mayo Clinic and the parsimonious Brock Model. RESULTS: Whole-lung analysis revealed differences between benign vs. malignant nodule groups in several parameters, e.g. the MLD (-766 vs. -790 HU) or the pEI (40.1 vs. 44.7 %). The proposed QCT model had an area-under-the-curve (AUC) of 0.69 (95%-CI, 0.62-0.76) based on all available data. After integrating MLD and pEI into the Mayo Clinic and Brock Model, the AUC of both clinical models improved (AUC, 0.91 to 0.93 and 0.88 to 0.91, respectively). The lobe-specific analysis revealed that the nodule-bearing lobes had less emphysema than the rest of the lung regarding benign (EI, 0.5 vs. 0.7 %; p < 0.001) and malignant nodules (EI, 1.2 vs. 1.7 %; p = 0.001). CONCLUSIONS: Nodules in subjects with higher whole-lung metrics of emphysema and less fibrosis are more likely to be malignant; hereby the nodule-bearing lobes have less emphysema. QCT variables could improve the risk assessment of incidental pulmonary nodules. KEY POINTS: • Nodules in subjects with higher whole-lung metrics of emphysema and less fibrosis are more likely to be malignant. • The nodule-bearing lobes have less emphysema compared to the rest of the lung. • QCT variables could improve the risk assessment of incidental pulmonary nodules.


Asunto(s)
Enfisema , Neoplasias Pulmonares , Nódulos Pulmonares Múltiples , Enfisema Pulmonar , Nódulo Pulmonar Solitario , Femenino , Humanos , Anciano , Masculino , Estudios Retrospectivos , Nódulo Pulmonar Solitario/diagnóstico por imagen , Nódulo Pulmonar Solitario/patología , Pulmón/diagnóstico por imagen , Pulmón/patología , Nódulos Pulmonares Múltiples/diagnóstico por imagen , Nódulos Pulmonares Múltiples/patología , Enfisema Pulmonar/diagnóstico por imagen , Enfisema Pulmonar/patología , Tomografía Computarizada por Rayos X/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Fibrosis
18.
Eur Radiol ; 2023 Oct 23.
Artículo en Inglés | MEDLINE | ID: mdl-37870625

RESUMEN

OBJECTIVES: The purpose of this study was to determine the influence of dose reduction on a commercially available lung cancer prediction convolutional neuronal network (LCP-CNN). METHODS: CT scans from a cohort provided by the local lung cancer center (n = 218) with confirmed pulmonary malignancies and their corresponding reduced dose simulations (25% and 5% dose) were subjected to the LCP-CNN. The resulting LCP scores (scale 1-10, increasing malignancy risk) and the proportion of correctly classified nodules were compared. The cohort was divided into a low-, medium-, and high-risk group based on the respective LCP scores; shifts between the groups were studied to evaluate the potential impact on nodule management. Two different malignancy risk score thresholds were analyzed: a higher threshold of ≥ 9 ("rule-in" approach) and a lower threshold of > 4 ("rule-out" approach). RESULTS: In total, 169 patients with 196 nodules could be included (mean age ± SD, 64.5 ± 9.2 year; 49% females). Mean LCP scores for original, 25% and 5% dose levels were 8.5 ± 1.7, 8.4 ± 1.7 (p > 0.05 vs. original dose) and 8.2 ± 1.9 (p < 0.05 vs. original dose), respectively. The proportion of correctly classified nodules with the "rule-in" approach decreased with simulated dose reduction from 58.2 to 56.1% (p = 0.34) and to 52.0% for the respective dose levels (p = 0.01). For the "rule-out" approach the respective values were 95.9%, 96.4%, and 94.4% (p = 0.12). When reducing the original dose to 25%/5%, eight/twenty-two nodules shifted to a lower, five/seven nodules to a higher malignancy risk group. CONCLUSION: CT dose reduction may affect the analyzed LCP-CNN regarding the classification of pulmonary malignancies and potentially alter pulmonary nodule management. CLINICAL RELEVANCE STATEMENT: Utilization of a "rule-out" approach with a lower malignancy risk threshold prevents underestimation of the nodule malignancy risk for the analyzed software, especially in high-risk cohorts. KEY POINTS: • LCP-CNN may be affected by CT image parameters such as noise resulting from low-dose CT acquisitions. • CT dose reduction can alter pulmonary nodule management recommendations by affecting the outcome of the LCP-CNN. • Utilization of a lower malignancy risk threshold prevents underestimation of pulmonary malignancies in high-risk cohorts.

19.
Langenbecks Arch Surg ; 408(1): 82, 2023 Feb 11.
Artículo en Inglés | MEDLINE | ID: mdl-36773118

RESUMEN

BACKGROUND: Differentiation of cystic pancreatic neoplasms remains a challenging task for radiologists regarding the main aim of identifying malignant and premalignant lesions. PURPOSE: The study aimed to compare the radiological features of lymphoepithelial cysts (LEC) with other cystic pancreatic lesions, which could help to differentiate them in order to avoid unnecessary resection. MATERIAL AND METHODS: We retrospectively reviewed 10 cases of resected and histopathologically confirmed LECs during a 12-year period with available imaging studies; 20 patients with mucinous cystic neoplasms (MCN), 20 patients with branch-duct intraductal papillary mucinous neoplasms (BD-IPMN), and 20 patients with serous cystic neoplasms (SCN) were selected to serve as control groups. Imaging findings as well as clinical data were analyzed. RESULTS: The following imaging morphology of LEC was identified: simple cystic appearance (20%) and mixed cystic-solid appearance (80%) with either a diffuse subsolid component (30%) or mural nodule(s) (50%). All lesions revealed exophytic location with a strong male predominance (9:1). MCNs occurred exclusively in middle-aged women, IPMN in both sexes showed slight male predominance (13:7), and SCN showed female predominance (5:15). Median patient age in LEC (48.5, IQR 47-54.5) was significantly younger compared to IPMN (p < 0.001) and SCN (p = 0.02). Unenhanced CT attenuation of LEC was higher than MCNs (p = 0.025) and IPMNs (p = 0.021), showing no significant difference to SCN (p = 0.343). CONCLUSION: The present study provides key radiological features of LEC for the differentiation from other cystic pancreatic lesions such as increased CT attenuation in the unenhanced phase, absence of a connection to the main pancreatic duct (MPD), and exophytic location. In addition to these imaging features, clinical data, such as male predominance in LEC, must be considered for the differentiation of cystic pancreatic lesions.


Asunto(s)
Carcinoma Ductal Pancreático , Neoplasias Quísticas, Mucinosas y Serosas , Quiste Pancreático , Neoplasias Intraductales Pancreáticas , Neoplasias Pancreáticas , Persona de Mediana Edad , Humanos , Masculino , Femenino , Quiste Pancreático/diagnóstico por imagen , Quiste Pancreático/cirugía , Quiste Pancreático/patología , Estudios Retrospectivos , Páncreas , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/cirugía , Neoplasias Pancreáticas/patología , Carcinoma Ductal Pancreático/diagnóstico por imagen , Carcinoma Ductal Pancreático/cirugía , Carcinoma Ductal Pancreático/patología
20.
Acta Radiol ; 64(3): 1038-1046, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35876445

RESUMEN

BACKGROUND: Recent studies support magnetic resonance angiography (MRA) as a diagnostic tool for pulmonary arterial disease. PURPOSE: To determine MRA image quality and reproducibility, and the dependence of MRA image quality and reproducibility on disease severity in patients with chronic obstructive pulmonary disease (COPD) and cystic fibrosis (CF). MATERIAL AND METHODS: Twenty patients with COPD (mean age 66.5 ± 8.9 years; FEV1% = 42.0 ± 13.3%) and 15 with CF (mean age 29.3 ± 9.3 years; FEV1% = 66.6 ± 15.8%) underwent morpho-functional chest magnetic resonance imaging (MRI) including time-resolved MRA twice one month apart (MRI1, MRI2), and COPD patients underwent non-contrast computed tomography (CT). Image quality was assessed visually using standardized subjective 5-point scales. Contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were measured by regions of interest. Disease severity was determined by spirometry, a well-evaluated chest MRI score, and by computational CT emphysema index (EI) for COPD. RESULTS: Subjective image quality was diagnostic for all MRA at MRI1 and MRI2 (mean score = 4.7 ± 0.6). CNR and SNR were 4 43.8 ± 8.7 and 50.5 ± 8.7, respectively. Neither image quality score nor CNR or SNR correlated with FEV1% or chest MRI score for COPD and CF (r = 0.239-0.248). CNR and SNR did not change from MRI1 to MRI2 (P = 0.434-0.995). Further, insignificant differences in CNR and SNR between MRA at MRI1 and MRI2 did not correlate with FEV1% nor chest MRI score in COPD and CF (r = -0.238-0.183), nor with EI in COPD (r = 0.100-0.111). CONCLUSION: MRA achieved diagnostic quality in COPD and CF patients and was highly reproducible irrespective of disease severity. This supports MRA as a robust alternative to CT in patients with underlying muco-obstructive lung disease.


Asunto(s)
Angiografía por Resonancia Magnética , Enfermedad Pulmonar Obstructiva Crónica , Humanos , Adulto , Persona de Mediana Edad , Anciano , Adulto Joven , Angiografía por Resonancia Magnética/métodos , Reproducibilidad de los Resultados , Pulmón/patología , Imagen por Resonancia Magnética/métodos , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico por imagen , Enfermedad Pulmonar Obstructiva Crónica/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA