Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Appl Clin Med Phys ; 21(5): 76-86, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32216098

RESUMEN

PURPOSE: The purpose of this study was to address the dosimetric accuracy of synthetic computed tomography (sCT) images of patients with brain tumor generated using a modified generative adversarial network (GAN) method, for their use in magnetic resonance imaging (MRI)-only treatment planning for proton therapy. METHODS: Dose volume histogram (DVH) analysis was performed on CT and sCT images of patients with brain tumor for plans generated for intensity-modulated proton therapy (IMPT). All plans were robustly optimized using a commercially available treatment planning system (RayStation, from RaySearch Laboratories) and standard robust parameters reported in the literature. The IMPT plan was then used to compute the dose on CT and sCT images for dosimetric comparison, using RayStation analytical (pencil beam) dose algorithm. We used a second, independent Monte Carlo dose calculation engine to recompute the dose on both CT and sCT images to ensure a proper analysis of the dosimetric accuracy of the sCT images. RESULTS: The results extracted from RayStation showed excellent agreement for most DVH metrics computed on the CT and sCT for the nominal case, with a mean absolute difference below 0.5% (0.3 Gy) of the prescription dose for the clinical target volume (CTV) and below 2% (1.2 Gy) for the organs at risk (OARs) considered. This demonstrates a high dosimetric accuracy for the generated sCT images, especially in the target volume. The metrics obtained from the Monte Carlo doses mostly agreed with the values extracted from RayStation for the nominal and worst-case scenarios (mean difference below 3%). CONCLUSIONS: This work demonstrated the feasibility of using sCT generated with a GAN-based deep learning method for MRI-only treatment planning of patients with brain tumor in intensity-modulated proton therapy.


Asunto(s)
Neoplasias Encefálicas , Terapia de Protones , Radioterapia de Intensidad Modulada , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/radioterapia , Humanos , Imagen por Resonancia Magnética , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Tomografía Computarizada por Rayos X
2.
Brachytherapy ; 23(2): 136-140, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38242726

RESUMEN

PURPOSE: Prospectively measure change in vaginal length after definitive chemoradiation (C-EBRT) with Intracavitary Brachytherapy (ICBT) for locally advanced cervix cancer (LACC) and correlate with vaginal dose (VD). MATERIALS AND METHODS: Twenty one female patients with LACC receiving C-EBRT and ICBT underwent serial vaginal length (VL) measurements. An initial measurement was made at the time of the first ICBT procedure and subsequently at 3 month intervals up to 1 year post radiation. The vagina was contoured as a 3-dimensional structure for each brachytherapy plan. The difference in VL before and at least 6 months after the last fraction of brachytherapy was considered as an indicator of toxicity. RESULTS: The mean initial VL was 8.7 cm (6.5-12) with median value of 8.5 cm. The mean VL after 6 months was 8.6 cm (6.5-12) and VL change was not found to be statistically significant. The median values (interquartile ranges) for vaginal D0.1cc, D1cc, and D2cc were 129.2 Gy (99.6-252.2), 96.9 Gy (84.2-114.9), and 89.6 Gy (82.4-102.2), respectively. No significant correlation was found between vaginal length change and the dosimetric parameters calculated for all patients. CONCLUSION: Definitive C-EBRT and ICBT did not significantly impact VL in this prospective cohort probably related to acceptable doses per ICRU constraints. Estimate of vaginal stenosis and sexual function was not performed in this cohort which is a limitation of this study and which we hope to study prospectively going forward.


Asunto(s)
Braquiterapia , Neoplasias del Cuello Uterino , Humanos , Femenino , Vagina , Neoplasias del Cuello Uterino/radioterapia , Recto , Dosificación Radioterapéutica , Constricción Patológica , Estudios Prospectivos , Braquiterapia/métodos
3.
Biomed Phys Eng Express ; 7(2)2021 02 24.
Artículo en Inglés | MEDLINE | ID: mdl-33545707

RESUMEN

Background and purpose.Replacing CT imaging with MR imaging for MR-only radiotherapy has sparked the interest of many scientists and is being increasingly adopted in radiation oncology. Although many studies have focused on generating CT images from MR images, only models on data with the same dataset were tested. Therefore, how well the trained model will work for data from different hospitals and MR protocols is still unknown. In this study, we addressed the model generalization problem for the MR-to-CT conversion task.Materials and methods.Brain T2 MR and corresponding CT images were collected from SZSPH (source domain dataset), brain T1-FLAIR, T1-POST MR, and corresponding CT images were collected from The University of Texas Southwestern (UTSW) (target domain dataset). To investigate the model's generalizability ability, four potential solutions were proposed: source model, target model, combined model, and adapted model. All models were trained using the CycleGAN network. The source model was trained with a source domain dataset from scratch and tested with a target domain dataset. The target model was trained with a target domain dataset and tested with a target domain dataset. The combined model was trained with both source domain and target domain datasets, and tested with the target domain dataset. The adapted model used a transfer learning strategy to train a CycleGAN model with a source domain dataset and retrain the pre-trained model with a target domain dataset. MAE, RMSE, PSNR, and SSIM were used to quantitatively evaluate model performance on a target domain dataset.Results.The adapted model achieved best quantitative results of 74.56 ± 8.61, 193.18 ± 17.98, 28.30 ± 0.83, and 0.84 ± 0.01 for MAE, RMSE, PSNR, and SSIM using the T1-FLAIR dataset and 74.89 ± 15.64, 195.73 ± 31.29, 27.72 ± 1.43, and 0.83 ± 0.04 for MAE, RMSE, PSNR, and SSIM using the T1-POST dataset. The source model had the poorest performance.Conclusions.This work indicates high generalization ability to generate synthetic CT images from small training datasets of MR images using pre-trained CycleGAN. The quantitative results of the test data, including different scanning protocols and different acquisition centers, indicated the proof of this concept.


Asunto(s)
Aprendizaje Profundo , Encéfalo/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X
4.
J Neuroimaging ; 29(3): 376-382, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30640412

RESUMEN

BACKGROUND AND PURPOSE: The anterior cingulate cortex (ACC) is involved in several cognitive processes including executive function. Degenerative changes of ACC are consistently seen in Alzheimer's disease (AD). However, volumetric changes specific to the ACC in AD are not clear because of the difficulty in segmenting this region. The objectives of the current study were to develop a precise and high-throughput approach for measuring ACC volumes and to correlate the relationship between ACC volume and cognitive function in AD. METHODS: Structural T1 -weighted magnetic resonance images of AD patients (n = 47) and age-matched controls (n = 47) at baseline and at 24 months were obtained from the Alzheimer's disease neuroimaging initiative (ADNI) database and studied using a custom-designed semiautomated segmentation protocol. RESULTS: ACC volumes obtained using the semiautomated protocol were highly correlated to values obtained from manual segmentation (r = .98) and the semiautomated protocol was considerably faster. When comparing AD and control subjects, no significant differences were observed in baseline ACC volumes or in change in ACC volumes over 24 months using the two segmentation methods. However, a change in ACC volume over 24 months did not correlate with a change in mini-mental state examination scores. CONCLUSIONS: Our results indicate that the proposed semiautomated segmentation protocol is reliable for determining ACC volume in neurodegenerative conditions including AD.


Asunto(s)
Enfermedad de Alzheimer/diagnóstico por imagen , Giro del Cíngulo/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Enfermedad de Alzheimer/patología , Bases de Datos Factuales , Giro del Cíngulo/patología , Humanos , Procesamiento de Imagen Asistido por Computador , Neuroimagen/métodos
5.
Radiother Oncol ; 136: 56-63, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31015130

RESUMEN

PURPOSE: This study assessed the dosimetric accuracy of synthetic CT images generated from magnetic resonance imaging (MRI) data for focal brain radiation therapy, using a deep learning approach. MATERIAL AND METHODS: We conducted a study in 77 patients with brain tumors who had undergone both MRI and computed tomography (CT) imaging as part of their simulation for external beam treatment planning. We designed a generative adversarial network (GAN) to generate synthetic CT images from MRI images. We used Mutual Information (MI) as the loss function in the generator to overcome the misalignment between MRI and CT images (unregistered data). The model was trained using all MRI slices with corresponding CT slices from each training subject's MRI/CT pair. RESULTS: The proposed GAN method produced an average mean absolute error (MAE) of 47.2 ±â€¯11.0 HU over 5-fold cross validation. The overall mean Dice similarity coefficient between CT and synthetic CT images was 80% ±â€¯6% in bone for all test data. Though training a GAN model may take several hours, the model only needs to be trained once. Generating a complete synthetic CT volume for each new patient MRI volume using a trained GAN model took only one second. CONCLUSIONS: The GAN model we developed produced highly accurate synthetic CT images from conventional, single-sequence MRI images in seconds. Our proposed method has strong potential to perform well in a clinical workflow for MRI-only brain treatment planning.


Asunto(s)
Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/radioterapia , Aprendizaje Profundo , Planificación de la Radioterapia Asistida por Computador/métodos , Huesos/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética/métodos , Dosificación Radioterapéutica , Radioterapia Guiada por Imagen/métodos , Radioterapia de Intensidad Modulada/métodos , Tomografía Computarizada por Rayos X/métodos
6.
Phys Med Biol ; 63(24): 245015, 2018 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-30523973

RESUMEN

Accurate segmentation of prostate and surrounding organs at risk is important for prostate cancer radiotherapy treatment planning. We present a fully automated workflow for male pelvic CT image segmentation using deep learning. The architecture consists of a 2D organ volume localization network followed by a 3D segmentation network for volumetric segmentation of prostate, bladder, rectum, and femoral heads. We used a multi-channel 2D U-Net followed by a 3D U-Net with encoding arm modified with aggregated residual networks, known as ResNeXt. The models were trained and tested on a pelvic CT image dataset comprising 136 patients. Test results show that 3D U-Net based segmentation achieves mean (±SD) Dice coefficient values of 90 (±2.0)%, 96 (±3.0)%, 95 (±1.3)%, 95 (±1.5)%, and 84 (±3.7)% for prostate, left femoral head, right femoral head, bladder, and rectum, respectively, using the proposed fully automated segmentation method.


Asunto(s)
Pelvis/diagnóstico por imagen , Próstata/diagnóstico por imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Recto/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Vejiga Urinaria/diagnóstico por imagen , Automatización , Aprendizaje Profundo , Cabeza Femoral/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Reproducibilidad de los Resultados , Riesgo
7.
PLoS One ; 13(10): e0205392, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30307999

RESUMEN

Deep learning has started to revolutionize several different industries, and the applications of these methods in medicine are now becoming more commonplace. This study focuses on investigating the feasibility of tracking patients and clinical staff wearing Bluetooth Low Energy (BLE) tags in a radiation oncology clinic using artificial neural networks (ANNs) and convolutional neural networks (CNNs). The performance of these networks was compared to relative received signal strength indicator (RSSI) thresholding and triangulation. By utilizing temporal information, a combined CNN+ANN network was capable of correctly identifying the location of the BLE tag with an accuracy of 99.9%. It outperformed a CNN model (accuracy = 94%), a thresholding model employing majority voting (accuracy = 95%), and a triangulation classifier utilizing majority voting (accuracy = 95%). Future studies will seek to deploy this affordable real time location system in hospitals to improve clinical workflow, efficiency, and patient safety.


Asunto(s)
Redes de Área Local/instrumentación , Sistemas de Identificación de Pacientes/métodos , Tecnología Inalámbrica/instrumentación , Algoritmos , Aprendizaje Profundo , Humanos , Aplicaciones Móviles , Oncología por Radiación/instrumentación
8.
PLoS One ; 12(6): e0178529, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28582450

RESUMEN

Previous studies have demonstrated altered brain activity in Alzheimer's disease using task based functional MRI (fMRI), network based resting-state fMRI, and glucose metabolism from 18F fluorodeoxyglucose-PET (FDG-PET). Our goal was to define a novel indicator of neuronal activity based on a first-order textural feature of the resting state functional MRI (RS-fMRI) signal. Furthermore, we examined the association between this neuronal activity metric and glucose metabolism from 18F FDG-PET. We studied 15 normal elderly controls (NEC) and 15 probable Alzheimer disease (AD) subjects from the AD Neuroimaging Initiative. An independent component analysis was applied to the RS-fMRI, followed by template matching to identify neuronal components (NC). A regional brain activity measurement was constructed based on the variation of the RS-fMRI signal of these NC. The standardized glucose uptake values of several brain regions relative to the cerebellum (SUVR) were measured from partial volume corrected FDG-PET images. Comparing the AD and NEC groups, the mean brain activity metric was significantly lower in the accumbens, while the glucose SUVR was significantly lower in the amygdala and hippocampus. The RS-fMRI brain activity metric was positively correlated with cognitive measures and amyloid ß1-42 cerebral spinal fluid levels; however, these did not remain significant following Bonferroni correction. There was a significant linear correlation between the brain activity metric and the glucose SUVR measurements. This proof of concept study demonstrates that this novel and easy to implement RS-fMRI brain activity metric can differentiate a group of healthy elderly controls from a group of people with AD.


Asunto(s)
Enfermedad de Alzheimer/líquido cefalorraquídeo , Amígdala del Cerebelo/metabolismo , Cerebelo/metabolismo , Hipocampo/metabolismo , Imagen por Resonancia Magnética/métodos , Núcleo Accumbens/metabolismo , Anciano , Anciano de 80 o más Años , Enfermedad de Alzheimer/diagnóstico , Enfermedad de Alzheimer/fisiopatología , Amígdala del Cerebelo/fisiopatología , Péptidos beta-Amiloides/líquido cefalorraquídeo , Estudios de Casos y Controles , Cerebelo/fisiopatología , Bases de Datos Factuales , Femenino , Fluorodesoxiglucosa F18/administración & dosificación , Hipocampo/fisiopatología , Humanos , Masculino , Núcleo Accumbens/fisiopatología , Fragmentos de Péptidos/líquido cefalorraquídeo , Tomografía de Emisión de Positrones , Radiofármacos/administración & dosificación
9.
J Neurosci Methods ; 227: 35-46, 2014 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-24518149

RESUMEN

BACKGROUND: The change in volume of anatomic structures is as a sensitive indicator of Alzheimer disease (AD) progression. Although several methods are available to measure brain volumes, improvements in speed and automation are required. Our objective was to develop a fully automated, fast, and reliable approach to measure change in medial temporal lobe (MTL) volume, including primarily hippocampus. METHODS: The MTL volume defined in an atlas image was propagated onto each baseline image and a level set algorithm was applied to refine the shape and smooth the boundary. The MTL of the baseline image was then mapped onto the corresponding follow-up image to measure volume change (ΔMTL). Baseline and 24 months 3D T1-weighted images from the Alzheimer Disease Neuroimaging Initiative (ADNI) were randomly selected for 50 normal elderly controls (NECs), 50 subjects with mild cognitive impairment (MCI) and 50 subjects with AD to test the algorithm. The method was compared to the FreeSurfer segmentation tools. RESULTS: The average ΔMTL (mean±SEM) was 68±35mm(3) in NEC, 187±38mm(3) in MCI and 300±34mm(3) in the AD group and was significantly different (p<0.0001) between all three groups. The ΔMTL was correlated with cognitive decline. COMPARISON WITH EXISTING METHOD(S): Results for the FreeSurfer software were similar but did not detect significant differences between the MCI and AD groups. CONCLUSION: This novel segmentation approach is fully automated and provides a robust marker of brain atrophy that shows different rates of atrophy over 2 years between NEC, MCI, and AD groups.


Asunto(s)
Algoritmos , Enfermedad de Alzheimer/patología , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Lóbulo Temporal/patología , Anciano , Anciano de 80 o más Años , Disfunción Cognitiva/patología , Femenino , Hipocampo/patología , Humanos , Masculino , Persona de Mediana Edad , Estadística como Asunto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA