Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38170282

RESUMEN

Current prospective reports suggest a pandemic-related increase in adolescent mental health problems. We examine whether age-related change over 11-14 years accounts for this increase. Mothers and adolescents in a UK-based birth cohort (Wirral Child Health and Development Study; WCHADS; N = 737) reported on adolescent depression and behavioural problems pre-pandemic (December 2019-March 2020), mid-pandemic (June 2020-March 2021) and late pandemic (July 2021-March 2022). Analysis used repeated measures models for over-dispersed Poisson counts with an adolescent-specific intercept with age as a time-varying covariate. Maturational curves for girls, but not for boys, showed a significant increase in self-reported depression symptoms over ages 11-14 years. Behavioural problems decreased for both. After adjusting for age-related change, girls' depression increased by only 13% at mid-pandemic and returned to near pre-pandemic level at late pandemic (mid versus late - 12%), whereas boys' depression increased by 31% and remained elevated (mid versus late 1%). Age-adjusted behavioural problems increased for both (girls 40%, boys 41%) and worsened from mid- to late pandemic (girls 33%, boys 18%). Initial reports of a pandemic-related increase in depression in young adolescent girls could be explained by a natural maturational rise. In contrast, maturational decreases in boys' depression and both boys' and girls' behavioural problems may mask an effect of the pandemic.

2.
J Clin Microbiol ; 59(8): e0096421, 2021 07 19.
Artículo en Inglés | MEDLINE | ID: mdl-34076473

RESUMEN

Infection with human cytomegalovirus (CMV) is common and may have grave consequences in transplant recipients and congenitally infected children. Diagnosis of CMV infection is based on detection of specific antibodies and molecular assays. The incorporation of CMV serological assays into diagnostic algorithms requires careful evaluation and interpretation. Very few serological assays measure CMV infection by a specific strain. We developed an enzyme-linked immunosorbent assay (ELISA) using CMV-encoded UL144 as the antigen. UL144 encodes three major genotypes, A, B, and C, and recombinants. The ELISA was developed with the three UL144 proteins and optimized as a multiplex assay. Sera from 55 positive and 59 negative CMV IgG, determined by the clinical microbiology laboratory, were used for evaluation and optimization. A cutoff optical density (OD) that distinguishes UL144 antibody-positive from antibody-negative sera was established. UL144 A, B, C, and combinations of these antigens were detected in sera. An assay threshold of 0.1 was established and, from a total of 303 sera, the overall sensitivity, specificity, and positive and negative predictive values of the multiplex ELISA were 86.72% (95% confidence interval [CI] 79.59% to 92.07%), 96.57% (92.69% to 98.73%), 94.40% (88.45% to 97.38%), and 91.60% (87.50% to 94.44%), respectively. The inter- and intraassay median coefficients of variation were 0.06 (interquartile range [IQR] 0.56, 0.2) and 0.171 (IQR 0.038, 0.302), respectively. No cross-reactivity was observed with HSV-positive CMV-negative sera. This ELISA gives simple and reproducible results for detection of anti-CMV UL144 IgG. It may assist in differentiating natural infection from CMV vaccines that lack UL144, and may provide an important tool for epidemiological studies of CMV strains.


Asunto(s)
Infecciones por Citomegalovirus , Citomegalovirus , Anticuerpos Antivirales , Niño , Citomegalovirus/genética , Infecciones por Citomegalovirus/diagnóstico , Ensayo de Inmunoadsorción Enzimática , Humanos , Inmunoglobulina G , Glicoproteínas de Membrana , Proteínas Virales
3.
Anaesthesist ; 70(12): 1031-1039, 2021 12.
Artículo en Alemán | MEDLINE | ID: mdl-34487216

RESUMEN

The publication of the new S3 guidelines on "full-term vaginal birth" and the guidelines on cesarean section, also published in 2020, provide further steps towards the promotion of evidence-based medicine in obstetrics, even if the exact configuration of neonatal monitoring during birth, in particular, is still the subject of current discussions. The multiprofessionality in the medical supervision of a birth is also fundamentally well-represented in the compilation of the S3 guidelines by the participating actors and specialist societies. Important from an anesthesiological perspective is the fact that neuraxial procedures still represent the gold standard in obstetric analgesia. With remifentanil PCA an alternative option is available that enables a reliable analgesia to be accomplished, e.g. when there are contraindications to performing neuraxial methods, if this is appropriate under the prevailing circumstances (1:1 support and appropriate monitoring). During an uncomplicated birth the strict fasting rules are relaxed. Overall, the guidelines underline the importance of self-determination and self-control for the expectant mother and give the highest priority to the safety and well-being of mother and child; however, this presupposes that the expectant mother is sufficiently informed about the value of neuraxial analgesia. For this it appears to be of importance to initiate information proposals, which go beyond the usual information sessions for parents that are often organized exclusively by midwives.


Asunto(s)
Analgesia Epidural , Analgesia Obstétrica , Anestesiólogos , Cesárea , Niño , Femenino , Humanos , Recién Nacido , Embarazo , Remifentanilo
4.
Ultrasound Obstet Gynecol ; 47(6): 674-9, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26094600

RESUMEN

OBJECTIVE: To determine whether the amniotic fluid index (AFI) or the single deepest vertical pocket (SDP) technique for estimating amniotic fluid volume is superior for predicting adverse pregnancy outcome. METHODS: This was a multicenter randomized controlled trial including 1052 pregnant women with a term singleton pregnancy across four hospitals in Germany. Women were assigned randomly, according to a computer-generated allocation sequence, to AFI or SDP measurement for estimation of amniotic fluid volume. Oligohydramnios was defined as AFI ≤ 5 cm or the absence of a pocket measuring at least 2 × 1 cm. The diagnosis of oligohydramnios was followed by labor induction. The primary outcome measure was postpartum admission to a neonatal intensive care unit. Further outcome parameters were the rates of diagnosis of oligohydramnios and induction of labor (for oligohydramnios or without specific indication), and mode of delivery. RESULTS: Postpartum admission to a neonatal intensive care unit was similar between groups (4.2% (n = 21) vs 5.0% (n = 25); relative risk (RR), 0.85 (95% CI, 0.48-1.50); P = 0.57). In the AFI group, there were more cases of oligohydramnios (9.8% (n = 49) vs 2.2% (n = 11); RR, 4.51 (95% CI, 2.2-8.57); P < 0.01) and more cases of labor induction for oligohydramnios (12.7% (n = 33) vs 3.6% (n = 10); RR, 3.50 (95% CI, 1.76-6.96); P < 0.01) than in the SDP group. Moreover, an abnormal cardiotocography was seen more often in the AFI group than in the SDP group (32.3% (n = 161) vs 26.2% (n = 132); RR, 1.23 (95% CI, 1.02-1.50); P = 0.03). The other outcome measures were not significantly different between the two groups. CONCLUSIONS: Use of the AFI method increased the rate of diagnosis of oligohydramnios and labor induction for oligohydramnios without improving perinatal outcome. The SDP method is therefore the favorable method to estimate amniotic fluid volume, especially in a population with many low-risk pregnancies. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.


Asunto(s)
Líquido Amniótico/diagnóstico por imagen , Trabajo de Parto Inducido/estadística & datos numéricos , Oligohidramnios/diagnóstico por imagen , Ultrasonografía Prenatal/métodos , Femenino , Humanos , Cuidado Intensivo Neonatal , Oligohidramnios/epidemiología , Admisión del Paciente/estadística & datos numéricos , Valor Predictivo de las Pruebas , Embarazo , Resultado del Embarazo
5.
Arch Gynecol Obstet ; 294(3): 487-93, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-26742730

RESUMEN

INTRODUCTION: To evaluate the influence of the time interval between examination and delivery on the accuracy of sonographic fetal weight estimation (WE). MATERIALS AND METHODS: 8723 singleton pregnancies were included in this retrospective cohort study. Fetuses were divided into eight groups with regard to the time interval between estimation and delivery (group 1: 0 days; group 2: 1-3 days; group 3: 4-7 days; group 4: 8-14 days; group 5: 15-21 days; group 6: 22-28 days; group 7: 29-35 days; group 8: 36-42 days). The accuracy of WE was compared between the different time interval groups and five commonly used formulas using means of percentage errors (MPE), medians of absolute percentage errors, and proportions of estimates within 10 % of actual birth weight. RESULTS: In group one, the Hadlock I and Warsof formula showed a systematic underestimation of fetal weight (negative MPEs). No systematic error was found with the Hadlock II formula and the equations of Merz and Shepard showed a systematic overestimation (positive MPEs). MPE values of the Hadlock I, II and Warsof formulas were closest to zero in WEs of group two. From group three to six, MPE values decreased continuously. With the Merz and Shepard equations MPEs were closest to zero in group four. DISCUSSION: The best accuracy of sonographic WE with most of the commonly used equations is achieved within a scan-to-delivery interval of 1 week.


Asunto(s)
Peso al Nacer , Peso Fetal , Ultrasonografía Prenatal , Adulto , Estudios Transversales , Femenino , Humanos , Embarazo , Estudios Retrospectivos
6.
Eur J Vasc Endovasc Surg ; 50(2): 167-74, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25892322

RESUMEN

OBJECTIVE: Little is known about the interactions between extracellular matrix (ECM) proteins and locally acting mechanical conditions and material macroscopic properties in abdominal aortic aneurysm (AAA). In this study, ECM components were investigated with correlation to corresponding biomechanical properties and loads in aneurysmal arterial wall tissue. METHODS: Fifty-four tissue samples from 31 AAA patients (30♂; max. diameter Dmax 5.98 ± 1.42 cm) were excised from the aneurysm sac. Samples were divided for corresponding immunohistological and mechanical analysis. Collagen I and III, total collagen, elastin, and proteoglycans were quantified by computational image analysis of histological staining. Pre-surgical CT data were used for 3D segmentation of the AAA and calculation of mechanical conditions by advanced finite element analysis. AAA wall stiffness and strength were assessed by repeated cyclical, sinusoidal and destructive tensile testing. RESULTS: Amounts of collagen I, III, and total collagen were increased with higher local wall stress (p = .002, .017, .030, respectively) and strain (p = .002, .012, .020, respectively). AAA wall failure tension exhibited a positive correlation with collagen I, total collagen, and proteoglycans (p = .037, .038, .022, respectively). α-Stiffness correlated with collagen I, III, and total collagen (p = .011, .038, and .008), while ß-stiffness correlated only with proteoglycans (p = .028). In contrast, increased thrombus thickness was associated with decreased collagen I, III, and total collagen (p = .003, .020, .015, respectively), and AAA diameter was negatively associated with elastin (p = .006). CONCLUSIONS: The present results indicate that in AAA, increased locally acting biomechanical conditions (stress and strain) involve increased synthesis of collagen and proteoglycans with increased failure tension. These findings confirm the presence of adaptive biological processes to maintain the mechanical stability of AAA wall.


Asunto(s)
Aorta Abdominal/química , Aorta Abdominal/fisiopatología , Aneurisma de la Aorta Abdominal/metabolismo , Aneurisma de la Aorta Abdominal/fisiopatología , Proteínas de la Matriz Extracelular/análisis , Hemodinámica , Anciano , Anciano de 80 o más Años , Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/complicaciones , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Rotura de la Aorta/etiología , Rotura de la Aorta/metabolismo , Rotura de la Aorta/fisiopatología , Aortografía/métodos , Fenómenos Biomecánicos , Progresión de la Enfermedad , Femenino , Análisis de Elementos Finitos , Humanos , Masculino , Persona de Mediana Edad , Interpretación de Imagen Radiográfica Asistida por Computador , Factores de Riesgo , Estrés Mecánico , Tomografía Computarizada por Rayos X , Rigidez Vascular
7.
BJOG ; 122(1): 129-36, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25327872

RESUMEN

OBJECTIVE: To evaluate the efficacy of inducing labour using a double-balloon catheter and oral misoprostol sequentially, in comparison with oral misoprostol alone. DESIGN: A multicentre randomised controlled trial. SETTING: Five hospitals in Germany. POPULATION: A total of 326 pregnant women with an unfavourable cervix undergoing labour induction at term. METHODS: Women were randomly assigned according to a computer-generated allocation sequence to sequential use of double-balloon catheter and oral misoprostol (study group) or oral misoprostol alone (control group). In the study group, the double-balloon catheter was used the first day before starting oral misoprostol the second day. MAIN OUTCOME MEASURES: The primary outcome measure was the induction-to-delivery interval, and a further outcome parameter was delivery within 48 hours. RESULTS: The median times for induction of labour until delivery were 32.4 hours in the study group and 22.5 hours in the control group (P = 0.004). This difference was not seen when evaluating according to parity (nulliparous, P = 0.19; parous, P = 0.06). The rate of vaginal delivery within 48 hours did not differ between both groups. The number of applications of misoprostol (two versus three, P < 0.001) and the dose of misoprostol used was lower in the study group (100 versus 200 µg, P < 0.001). In the study group, there were more Apgar scores of <7 at 5 minutes (8 versus 1, P = 0.04). CONCLUSIONS: The use of a double-balloon catheter on the first day, before starting oral misoprostol on the second day, did not improve the induction to delivery interval and the rate of delivery within 48 hours, in comparison with oral misoprostol alone.


Asunto(s)
Cateterismo/métodos , Catéteres , Maduración Cervical , Parto Obstétrico/estadística & datos numéricos , Trabajo de Parto Inducido/métodos , Misoprostol , Oxitócicos , Administración Oral , Adolescente , Adulto , Anestesia Epidural/estadística & datos numéricos , Anestesia Obstétrica/estadística & datos numéricos , Cesárea/estadística & datos numéricos , Terapia Combinada , Femenino , Humanos , Oxitocina , Embarazo , Resultado del Tratamiento , Adulto Joven
8.
Arch Gynecol Obstet ; 292(1): 59-67, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25534163

RESUMEN

PURPOSE: To evaluate the influence of the time interval between examination and delivery on the accuracy of sonographic weight estimation (WE) in fetal macrosomia. MATERIALS AND METHODS: 896 singleton pregnancies (birth weight > 4,000 g) with a total of 1,281 sonographic weight estimations were included in this retrospective cohort study. Fetuses were divided into six groups with regard to the time interval between estimation and delivery: group 1: scan-to-delivery interval: 0 days; group 2: scan-to-delivery interval: 1-3 days; group 3: scan-to-delivery interval: 4-7 days; group 4: scan-to-delivery interval: 8-14 days; group 5: scan-to-delivery interval: 15-21 days; group 6: scan-to-delivery interval: 22-42 days. The accuracy of WE was compared between five commonly used formulas using means of percentage errors (MPE), random error, medians of absolute percentage errors (MAPE), and proportions of estimates within 10 % of actual birth weight. RESULTS: Significant differences were found between the time interval groups with regard to MAPE and MPE values (p < 0.001). All formulas showed a systematic underestimation of fetal weight (negative MPEs) (p < 0.05). MPE values were closest to zero in time interval group 1 and 2. From group 3 to 6, a continuous decrease was observed. The lowest MAPE was found with the Merz formula in group 1 and 2. Values increased continuously from group 3 to 6. Differences between time interval group one and three did not reach statistical significance. CONCLUSIONS: WE in fetal macrosomia shows the best results when examinations are performed within 7 days before delivery, using the formula of Merz et al. Accuracy significantly decreases after this time period.


Asunto(s)
Parto Obstétrico , Macrosomía Fetal/diagnóstico por imagen , Peso Fetal/fisiología , Ultrasonografía Prenatal/métodos , Adulto , Peso al Nacer , Estudios de Cohortes , Estudios Transversales , Femenino , Humanos , Recién Nacido , Masculino , Embarazo , Estudios Retrospectivos , Factores de Tiempo , Adulto Joven
9.
Arch Gynecol Obstet ; 292(4): 805-11, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25870017

RESUMEN

PURPOSE: To evaluate the accuracy of intrapartum sonographic weight estimation (WE). MATERIALS AND METHODS: This retrospective, cross-sectional study included 1958 singleton pregnancies. Inclusion criteria were singleton pregnancy with cephalic presentation, vaginal delivery and ultrasound examination with complete biometric parameters performed on the day of delivery during the latent or active phase of labor, and absence of chromosomal or structural anomalies. The accuracy of intrapartum WE was compared to a control group of fetuses delivered by primary cesarean section at our perinatal center and an ultrasound examination with complete biometric parameters performed within 3 days before delivery (n = 392). Otherwise, the same inclusion criteria as in the study group were applied. The accuracy of WE was compared between five commonly applied formulas using means of percentage errors (MPE), medians of absolute percentage errors (MAPE), and proportions of estimates within 10 % of actual birth weight. RESULTS: In the whole study group, all equations showed a systematic underestimation of fetal weight (negative MPEs). Overall, best MAPE and MPE values were found with the Hadlock II formula, using BPD, AC and FL as biometric parameters (Hadlock II, MPE: -1.28; MAPE: 6.52). MPEs differed significantly between WE in the study and control group for all evaluated formulas: in the control group, either no systematic error (Hadlock III, IV and V) or a significant overestimation (Hadlock I, II) was found. Regarding MAPEs, application of the Hadlock III (HC, AC, FL) and V (AC) formula resulted in significant lower values in the control group (Hadlock III, MAPE: 7.48 vs. 5.95, p = 0.0008 and Hadlock V, MAPE: 8.79 vs. 7.52, p = 0.0085). No significant differences were found for the other equations. CONCLUSIONS: A systematic underestimation of fetal weight has to be taken into account in sonographic WE performed intrapartum. Overall, the best results can be achieved with WE formulas using the BPD as the only head measurement.


Asunto(s)
Peso Fetal/fisiología , Ultrasonografía Prenatal/métodos , Adulto , Biometría , Peso al Nacer/fisiología , Cefalometría/métodos , Cefalometría/estadística & datos numéricos , Estudios Transversales , Parto Obstétrico , Femenino , Humanos , Trabajo de Parto , Valor Predictivo de las Pruebas , Embarazo , Análisis de Regresión , Estudios Retrospectivos
10.
Ultraschall Med ; 36(6): 630-6, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25014478

RESUMEN

PURPOSE: To determine the accuracy of sonographic weight estimation (WE) for small-for-gestational-age (SGA) fetuses, and to further differentiate the evaluation between symmetric and asymmetric SGA fetuses. MATERIALS AND METHODS: The accuracy of WE in SGA fetuses (n = 898) was evaluated using 14 sonographic models and was further differentiated between symmetric (n = 750) and asymmetric (n = 148) SGA fetuses. SGA fetuses were considered to be asymmetric with a head circumference to abdominal circumference ratio above the 95th percentile. The accuracy of the different formulas was compared using means of percentage errors (MPE), medians of absolute percentage errors (MAPE), and proportions of estimates within 10 % of actual birth weight. RESULTS: RESULTS for the subgroup of asymmetric SGA fetuses differed significantly from the subgroup of symmetric SGA fetuses. MPE values were closer to zero with most of the formulas in the asymmetric SGA group. Apart from the Siemer, Shepard, Merz and Warsof equations, all formulas showed an underestimation of fetal weight in asymmetric SGA fetuses. In contrast, in the symmetric SGA group, all of the formulas commonly used for fetuses in a normal weight range showed a systematic overestimation of fetal weight. Overall the best accuracy was achieved by using the Sabbagha equation (MPE 1.7 %; SD 9.0 %; MAPE: 6.0). CONCLUSION: An accurate WE in SGA fetuses is feasible using the Sabbagha formula. However, one has to be aware of the significant differences in WE between symmetric and asymmetric SGA fetuses.


Asunto(s)
Peso Fetal/fisiología , Recién Nacido Pequeño para la Edad Gestacional/fisiología , Cefalometría , Estudios Transversales , Femenino , Edad Gestacional , Humanos , Recién Nacido , Masculino , Embarazo , Estudios Retrospectivos , Sensibilidad y Especificidad , Estadística como Asunto , Circunferencia de la Cintura
11.
Ultraschall Med ; 36(3): 284-9, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24927106

RESUMEN

PURPOSE: The accuracy of the sonographic weight estimation (WE) of fetuses with congenital diaphragmatic hernia (CDH) is significantly lower than that of fetuses without any malformations. The objective of this study was to develop and evaluate the first specific sonographic weight formula for fetuses with CDH. MATERIALS AND METHODS: In a retrospective, multicenter, cohort study, a statistical estimation technique known as "multivariable fractional polynomial regression" was applied to a group of 146 fetuses with CDH. Each fetus underwent an ultrasound examination with complete biometric parameters within 7 days of delivery. A new formula was derived using the obtained data and was then compared with other commonly used equations. The accuracy of the different formulas was compared using means of signed percentage errors (SPE), medians of absolute percentage errors (MAPE), and fractions of estimates within prespecified error bounds. RESULTS: The new derived formula is: EFW = 10^(4.6729 107 371 + 0.2365 011 768 * HC + 0.2228 897 682 * FL^2 - 0.0129 895 773 * FL^3 - 1.0470 039 072 * (FL * HC)^0.5 + 0.0004 314 661 * (AC * HC) - [in case of liver herniation] 0.0062 112 122), where EFW is the estimated fetal weight, HC is the head circumference, AC is the abdominal circumference, and FL is the femur length. The new formula proved to be superior to other established equations, showing both the lowest median absolute percentage error (MAE: 6.97) and mean signed percentage error (SPE: 0.40), and the best distribution of absolute percentage errors within prespecified error bounds. CONCLUSION: This new formula significantly improves weight estimation in fetuses with CDH.


Asunto(s)
Peso Fetal , Hernias Diafragmáticas Congénitas/diagnóstico por imagen , Ultrasonografía Prenatal/métodos , Estudios de Cohortes , Femenino , Humanos , Recién Nacido , Masculino , Modelos Estadísticos , Embarazo , Análisis de Regresión , Estudios Retrospectivos
12.
Z Geburtshilfe Neonatol ; 219(2): 87-91, 2015 Apr.
Artículo en Alemán | MEDLINE | ID: mdl-25901869

RESUMEN

PURPOSE: Many international guidelines recommend induction of labour beyond 41 weeks to reduce perinatal morbidity and mortality. In 2010, a new German guideline with this recommendation was published. The aim of this study was to investigate whether this recommendation influenced clinical outcome. MATERIAL AND METHODS: All cases with induction of labour beyond 40 weeks in 2008, 2009, 2011 and 2012 were examined. Multiple pregnancy and Caesarean section in the case history were exclusion criteria. The years before publication of the new German guideline (2008 and 2009) were compared with those afterwards (2011 and 2012) with regard to several outcome parameters like rate of labour induction, efficacy of induction of labour and foetal outcome. RESULTS: After publication of the guideline there were more inductions of labour undertaken (300 [11.2%] vs. 472 [15.4%], p<0.0001) with less pregnancies beyond 42 weeks (9 [3%] vs. 5 [1%], p=0.0489). However, there was no difference concerning the efficacy of induction of labour, e. g., the ratio of Caesarean sections was not increased. There was no impairment of foetal outcome, in contrast, the ratio of postpartal admission to NICU was decreased (42 [14.2%] vs. 31 [6.7%], p=0.0006). CONCLUSION: The new recommendation of the German guideline to induce labour beyond 41 weeks leads to more cases with induction of labour without any negative impact on its efficacy or foetal outcome.


Asunto(s)
Trabajo de Parto Inducido/estadística & datos numéricos , Trabajo de Parto Inducido/normas , Obstetricia/normas , Guías de Práctica Clínica como Asunto , Pautas de la Práctica en Medicina/estadística & datos numéricos , Pautas de la Práctica en Medicina/normas , Adulto , Femenino , Alemania/epidemiología , Adhesión a Directriz/normas , Adhesión a Directriz/estadística & datos numéricos , Humanos , Embarazo , Resultado del Embarazo , Revisión de Utilización de Recursos
13.
Ultraschall Med ; 34(6): 573-9, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23143882

RESUMEN

PURPOSE: To determine the accuracy of sonographic weight estimation (WE) for fetuses with congenital diaphragmatic hernia (CDH), and to assess whether certain sonographic models perform better than others in cases of CDH. MATERIAL AND METHODS: In a retrospective, multicenter cohort study, the accuracy of WE in fetuses with CDH (n = 172) was evaluated using eight sonographic models and was compared with a control group of fetuses without malformations (n = 172). Each fetus underwent ultrasound examination with complete biometric parameters within 7 days of delivery. The accuracy of the different formulas was compared using means of percentage errors (MPE), medians of absolute percentage errors (MAPE), and proportions of estimates within 10 % of actual birth weight. RESULTS: Fetuses with CDH had a significantly lower abdominal circumference (AC) in comparison with the control group (293.6 vs. 312.0 mm, p < 0.001). All of the formulas tested in fetuses with CDH, except for the Siemer equation (the only model that does not incorporate any abdominal measurements), showed significantly lower (more negative) MPEs, larger MAPEs, and smaller proportions of estimates within 10 % of actual birth weight in comparison with the control group.  CONCLUSION: The accuracy of sonographic WE in fetuses with CDH is significantly poorer than in fetuses without malformations, principally because of a larger systematic error due to artificially small AC measurements. The development of new, specific models derived from fetuses with CDH could improve the accuracy of WE for infants with this condition.


Asunto(s)
Peso Fetal/fisiología , Hernia Diafragmática/diagnóstico por imagen , Hernias Diafragmáticas Congénitas , Ultrasonografía Prenatal/métodos , Peso al Nacer/fisiología , Cefalometría/métodos , Estudios de Cohortes , Femenino , Humanos , Recién Nacido , Hígado/anomalías , Hígado/diagnóstico por imagen , Masculino , Valor Predictivo de las Pruebas , Embarazo , Valores de Referencia , Análisis de Regresión , Sensibilidad y Especificidad
14.
Ultrasound Obstet Gynecol ; 39(5): 543-8, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-21898638

RESUMEN

OBJECTIVE: Commonly used formulae for fetal weight estimation, including combinations of several biometric parameters, lack accuracy despite efforts to improve them. This study aimed to investigate the limits of fetal weight estimation based on conventional biometric parameters on two-dimensional (2D) ultrasound by developing and evaluating new weight equations using postpartum biometric parameters. METHODS: This was a prospective multicenter study including 628 singleton pregnancies at term. Inclusion criteria were healthy newborns with no physical or chromosomal malformations. Postpartum measurement of head circumference, abdominal circumference and thigh length was performed. Six 'best-fit' formulae were derived using forward regression analysis in a formula-finding group (n = 419), and their accuracy was compared with birth weight in an evaluation group (n = 209) using percentage error, absolute percentage error, limits of agreement and the proportion of weight estimations falling within a discrepancy level of ± 10%. RESULTS: The new formulae showed no systematic error, with SD for the percentage error between 7.42 and 8.77 and no significant differences between median absolute percentage errors (4.84-5.71). They included 74.6-81.3% of neonates within a discrepancy level of 10%. With regard to the 95% limits of agreement, weight estimates were within a range of about ± 500 g. CONCLUSION: These results show that a good sonographic weight formula has the following features: no systematic error, an SD of about 7% and inclusion of 80% of cases within a discrepancy level of 10%. The study indicates that the current accuracy of fetal weight estimation with conventional biometric parameters by 2D ultrasound has reached its limits. Further improvement will probably only be achieved through new approaches in ultrasonography.


Asunto(s)
Biometría , Peso al Nacer , Peso Fetal , Periodo Posparto , Ultrasonografía Prenatal , Biometría/métodos , Peso al Nacer/fisiología , Femenino , Peso Fetal/fisiología , Humanos , Recién Nacido , Masculino , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Embarazo , Estudios Prospectivos , Análisis de Regresión , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Ultrasonografía Prenatal/métodos
15.
Ultraschall Med ; 33(3): 265-9, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21080309

RESUMEN

PURPOSE: Birth weight (BW) is an important prognostic parameter for neonatal morbidity and mortality. Commonly used weight formulas lack accuracy, especially at the lower and upper end of the fetal weight range. Fetal abdominal circumference (AC) as part of most of the commonly used equations has the greatest impact on weight estimation. It has been shown that formulas specifically designed for a small fetal AC can improve weight estimation. The aim was to find out whether a new formula specifically designed for fetuses with a large AC may also improve weight determination. MATERIALS AND METHODS: The study included 830 singleton pregnancies. The inclusion criteria were ultrasound examination with complete biometric parameters and an AC ≥ 36.0 cm within 7 days of delivery, and an absence of structural or chromosomal malformations. Two "best-fit" formulas were derived by forward regression analysis. The accuracy of the new formulas was compared with commonly used weight equations using percentage error (PE), absolute percentage error (APE), limits of agreement (LOA) and cumulative distribution. RESULTS: New formula I had no systematic error while new formula II and the routine methods significantly overestimated fetal weight. The medians of the APE were the lowest among the new equations (5.77 and 7.25). The new formulas also demonstrated the narrowest LOA. Importantly, at all discrepancy levels (5 %, 10 %, 15 %, and 20 %), new formula I included significantly more cases than the commonly used methods. CONCLUSION: These specifically designed equations help to improve fetal weight estimation for fetuses with an AC ≥ 36.0 cm. For optimal weight estimation, we recommend using new formula I.


Asunto(s)
Macrosomía Fetal/diagnóstico por imagen , Peso Fetal/fisiología , Interpretación de Imagen Asistida por Computador/métodos , Ultrasonografía Prenatal/métodos , Circunferencia de la Cintura/fisiología , Adolescente , Adulto , Peso al Nacer/fisiología , Estudios Transversales , Femenino , Humanos , Recién Nacido , Masculino , Persona de Mediana Edad , Embarazo , Análisis de Regresión , Sensibilidad y Especificidad , Adulto Joven
16.
Ultraschall Med ; 33(5): 469-73, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21630187

RESUMEN

PURPOSE: Accurate estimation of fetal weight is a valuable tool for determining further obstetric management. Commonly used weight formulas lack accuracy, even though some equations appear to be favorable within defined weight ranges. However, due to the fact that fetal weight is not known in advance, it is not always clear which formula is suitable. In most of the commonly used equations, the fetal abdominal circumference (AC) is not only included but also has the greatest impact on weight estimation. The aim of our study was to develop and evaluate a new formula specifically designed for a small fetal AC in order to improve weight estimation. MATERIALS AND METHODS: The study included 323 pregnancies. The inclusion criteria were singleton pregnancy, ultrasound examination with complete biometric parameters and an AC ≤ 29.0 cm within 7 days of delivery, and an absence of structural or chromosomal malformations. Two "best-fit" formulas were derived by forward regression analysis. Finally, the accuracy of the new formulas was compared to commonly used weight equations by using the percentage error, absolute percentage error (APE), limits of agreement (LOA) and cumulative distribution. RESULTS: Contrary to the routine methods, which significantly underestimated fetal weight, the new formulas did not have a systematic error. The medians of the APE were the lowest (7.13 and 7.16) when compared to other equations. Moreover, the new formulas demonstrated the narrowest LOA. At all discrepancy levels (5%, 10%, 15%, and 20%), the new formulas included significantly more cases than the commonly used methods. CONCLUSION: The specifically designed equations help to improve fetal weight estimation for fetuses with an AC ≤ 29.0 cm. For optimal weight estimation, we recommend using the new formula II.


Asunto(s)
Peso Fetal/fisiología , Ultrasonografía Prenatal/métodos , Circunferencia de la Cintura/fisiología , Adolescente , Adulto , Peso al Nacer/fisiología , Interpretación Estadística de Datos , Femenino , Humanos , Recién Nacido , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Embarazo , Reproducibilidad de los Resultados , Ultrasonografía Prenatal/estadística & datos numéricos , Adulto Joven
17.
Z Geburtshilfe Neonatol ; 216(6): 246-52, 2012 Dec.
Artículo en Alemán | MEDLINE | ID: mdl-23264179

RESUMEN

PURPOSE: The aim of this study was to evaluate expectations of pregnant women on an ideal maternity hospital. MATERIAL AND METHODS: We prospectively performed a survey among 566 pregnant women with regard to their expectations on a perfect hospital for obstetrics. Data collection was accomplished in 3 obstetrical departments in Mannheim, Germany. The questionnaire contained 23 general questions about sociodemographic characteristics and 34 specific questions about the anticipated childbirth. Women who were less than 20 weeks pregnant and women who did not speak German fluently were excluded from this study. RESULTS: In our survey the possibility to get to know midwifes and doctors at information evenings and a guided delivery room tour were defined as very important factors by the interviewed women. Of particular importance was a continuous care by a single midwife and the physical attendance of a family member during childbirth. Furthermore, friendliness of the staff and medical care by paediatricians after childbirth were identified to be important. To some extent, a modern appearance of the ward was also a matter of importance. CONCLUSIONS: The medical treatment of mother and the newborn child and the friendliness of the staff have been identified as the most important factors with regard to the expectations of women on an ideal maternity hospital. In addition, a pleasant ambiance of the ward and regular visits by a lactation specialist were named as important.


Asunto(s)
Maternidades , Satisfacción del Paciente , Mujeres Embarazadas/psicología , Adulto , Femenino , Alemania , Ambiente de Instituciones de Salud , Investigación sobre Servicios de Salud , Humanos , Recién Nacido , Partería , Relaciones Enfermero-Paciente , Relaciones Médico-Paciente , Embarazo , Estudios Prospectivos , Encuestas y Cuestionarios , Adulto Joven
18.
Klin Padiatr ; 223(7): 414-8, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22116781

RESUMEN

Cytokines play an important role in immune regulation and fetal lung development. The systemic inflammatory response in newborns with congenital diaphragmatic hernia (CDH) has not been characterized so far. We compared various concentrations of cytokines in serum from newborns with CDH and in healthy term neonates. We analyzed cytokine patterns of CDH newborns under extracorporeal membrane oxygenation (ECMO) and mechanical ventilation (MV).38 newborns with CDH were included: ECMO group (n=13) and non-ECMO group (n=25). Healthy term neonates served as controls (n=13). Serum samples were obtained prospectively after birth and during therapy.Concentrations of IFN-α, IL-3,-6,-7,-8,-10, MIP-1α,-1ß and TNF-α in serum of newborns with CDH were higher than in umbilical cord blood of term neonates. Infants with severe CDH requiring ECMO therapy had higher postnatal IL-8,-10, and MIP-1α levels than newborns with milder disease in the non-ECMO treated group. IL-10 progressively decreased during the first 3 days following birth under ECMO. In contrast, the chemokine MIP-1α remained elevated during ECMO therapy compared to mechanically ventilated CDH newborns.The pattern of cytokines in the serum of newborns with CDH showed significant elevations compared to term neonates. Our findings indicate that CDH is associated with systemic inflammatory response immediately after birth. ECMO and MV show a similar increase of IL-1α and IP-10 in CDH newborns assuming a persistent pulmonary inflammatory reaction irrespective of the conducted treatment.


Asunto(s)
Citocinas/sangre , Hernias Diafragmáticas Congénitas , Oxigenación por Membrana Extracorpórea , Femenino , Hernia Diafragmática/inmunología , Hernia Diafragmática/terapia , Humanos , Recién Nacido , Masculino , Estudios Prospectivos , Valores de Referencia , Respiración Artificial , Síndrome de Respuesta Inflamatoria Sistémica/diagnóstico , Síndrome de Respuesta Inflamatoria Sistémica/inmunología , Resultado del Tratamiento
19.
J Insect Physiol ; 106(Pt 3): 163-171, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29278714

RESUMEN

In the face of global warming, both the absolute thermal tolerance of an ectotherm, and its ability to shift its tolerance level via acclimation, are thought to be fundamentally important. Understanding the links between tolerance and its plasticity is therefore critical to accurately predict vulnerability to warming. Previous studies in a number of ectotherm taxa suggest trade-offs in the evolution of thermal tolerance and its plasticity, something which does not, however, apply to Deronectes diving beetles, where these traits are instead positively correlated. Here we revisit the relationship between thermal tolerance and plasticity in these beetles, paying attention to a recently discovered morphological adaptation supporting under water respiration - setal tracheal gills. Hollow setae on the elytra interconnect with the beetle's tracheal system, providing a gas exchange surface that allows oxygen to be extracted directly from the water. This enables individuals to stay submerged for longer than their subelytral air stores would allow. We show that hypoxia reduced heat tolerance, especially when individuals were denied access to air, forcing them to rely solely on aquatic gas exchange. Species with higher densities of these gas-exchanging setae exhibited improved cold tolerance, but reduced heat tolerance and lower plasticity of heat tolerance. Differences in setal tracheal gill density across species were also related to habitat use: species with low gill density were found mainly in intermittent, warmer rivers, where underwater gas exchange is more problematic and risks of surfacing may be smaller. Moreover, when controlling for differences in gill density we no longer found a significant relationship between heat tolerance and its plasticity, suggesting that the previously reported positive relationship between these variables may be driven by differences in gill density. Differences in environmental conditions between the preferred habitats could simultaneously select for characteristic differences in both thermal tolerance and gill density. Such simultaneous selection may have resulted in a non-causal association between cold tolerance and gill density. For heat tolerance, the correlations with gill density could reflect a causal relationship. Species relying strongly on diffusive oxygen uptake via setal tracheal gills may have a reduced oxygen supply capacity and may be left with fewer options for matching oxygen uptake to oxygen demand during acclimation, which could explain their reduced heat tolerance and limited plasticity. Our study helps shed light on the mechanisms that underpin thermal tolerance and plasticity in diving air-breathing ectotherms, and explores how differences in thermal tolerance across species are linked to their selected habitat, morphological adaptations and evolutionary history.


Asunto(s)
Escarabajos/fisiología , Oxígeno/fisiología , Termotolerancia , Animales , Escarabajos/anatomía & histología , Ecosistema , Branquias/anatomía & histología
20.
Placenta ; 62: 58-65, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29405968

RESUMEN

INTRODUCTION: Preeclampsia is a hypertensive, gestational disease, which is still the leading cause of pregnancy related morbidity and mortality. The impairment of placental angiogenesis and vascularization is discussed to be of etiopathologic relevance. Deytrosination and tyrosination of α-tubulin is important for the stability and dynamics of microtubules. An increase of α-tubulin detyrosination leads to microtubule stabilization, which is an essential prerequisite for physiologic vascular tube morphogenesis during angiogenesis. So far, little is known about the specific localization of detyrosinated (detyr) and tyrosinated (tyr) tubulin in the placenta and its relevance for preeclampsia. METHODS: Placental expression of detyr- and tyr-tubulin was analyzed by immunohistochemistry, immunofluorescence and western blot. For western blot quantification we used biopsies from healthy placentas (n = 21) and placentas from pregnancies complicated with small for gestational age (n = 5), preeclampsia (n = 5) or both (n = 5). RESULTS: Specific placental localization of detyr-tubulin was detected in the fetal endothelial cells of the placenta. Villous and extravillous trophoblasts as well as villous stroma cells were tyr-tubulin positive. Detyr-tubulin protein expression was significantly decreased in placentas complicated by preeclampsia. CONCLUSIONS: In summary, we report an accumulation of detyr-tubulin in villous vessels of the placenta and a significantly reduced level of detyr-tubulin in placental biopsies of preeclampsia cases. The reduction of placental detyr-tubulin in preeclampsia could suggest a deficit in villous vascular plasticity and might be associated with the impaired arborization of the disease.


Asunto(s)
Placenta/metabolismo , Preeclampsia/metabolismo , Procesamiento Proteico-Postraduccional/fisiología , Tubulina (Proteína)/metabolismo , Tirosina/metabolismo , Vellosidades Coriónicas/metabolismo , Células Endoteliales/metabolismo , Femenino , Humanos , Recién Nacido Pequeño para la Edad Gestacional , Microtúbulos/metabolismo , Embarazo , Células del Estroma/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA