Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
J Am Chem Soc ; 144(19): 8756-8769, 2022 05 18.
Artículo en Inglés | MEDLINE | ID: mdl-35508182

RESUMEN

Here, we show how signal amplification by reversible exchange hyperpolarization of a range of 15N-containing synthons can be used to enable studies of their reactivity by 15N nuclear magnetic resonance (NO2- (28% polarization), ND3 (3%), PhCH2NH2 (5%), NaN3 (3%), and NO3- (0.1%)). A range of iridium-based spin-polarization transfer catalysts are used, which for NO2- work optimally as an amino-derived carbene-containing complex with a DMAP-d2 coligand. We harness long 15N spin-order lifetimes to probe in situ reactivity out to 3 × T1. In the case of NO2- (T1 17.7 s at 9.4 T), we monitor PhNH2 diazotization in acidic solution. The resulting diazonium salt (15N-T1 38 s) forms within 30 s, and its subsequent reaction with NaN3 leads to the detection of hyperpolarized PhN3 (T1 192 s) in a second step via the formation of an identified cyclic pentazole intermediate. The role of PhN3 and NaN3 in copper-free click chemistry is exemplified for hyperpolarized triazole (T1 < 10 s) formation when they react with a strained alkyne. We also demonstrate simple routes to hyperpolarized N2 in addition to showing how utilization of 15N-polarized PhCH2NH2 enables the probing of amidation, sulfonamidation, and imine formation. Hyperpolarized ND3 is used to probe imine and ND4+ (T1 33.6 s) formation. Furthermore, for NO2-, we also demonstrate how the 15N-magnetic resonance imaging monitoring of biphasic catalysis confirms the successful preparation of an aqueous bolus of hyperpolarized 15NO2- in seconds with 8% polarization. Hence, we create a versatile tool to probe organic transformations that has significant relevance for the synthesis of future hyperpolarized pharmaceuticals.


Asunto(s)
Imagen por Resonancia Magnética , Dióxido de Nitrógeno , Iminas , Espectroscopía de Resonancia Magnética/métodos , Nitrógeno
2.
Br J Cancer ; 127(2): 337-349, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35462561

RESUMEN

BACKGROUND: Breast cancer remains a leading cause of death in women and novel imaging biomarkers are urgently required. Here, we demonstrate the diagnostic and treatment-monitoring potential of non-invasive sodium (23Na) MRI in preclinical models of breast cancer. METHODS: Female Rag2-/- Il2rg-/- and Balb/c mice bearing orthotopic breast tumours (MDA-MB-231, EMT6 and 4T1) underwent MRI as part of a randomised, controlled, interventional study. Tumour biology was probed using ex vivo fluorescence microscopy and electrophysiology. RESULTS: 23Na MRI revealed elevated sodium concentration ([Na+]) in tumours vs non-tumour regions. Complementary proton-based diffusion-weighted imaging (DWI) linked elevated tumour [Na+] to increased cellularity. Combining 23Na MRI and DWI measurements enabled superior classification accuracy of tumour vs non-tumour regions compared with either parameter alone. Ex vivo assessment of isolated tumour slices confirmed elevated intracellular [Na+] ([Na+]i); extracellular [Na+] ([Na+]e) remained unchanged. Treatment with specific inward Na+ conductance inhibitors (cariporide, eslicarbazepine acetate) did not affect tumour [Na+]. Nonetheless, effective treatment with docetaxel reduced tumour [Na+], whereas DWI measures were unchanged. CONCLUSIONS: Orthotopic breast cancer models exhibit elevated tumour [Na+] that is driven by aberrantly elevated [Na+]i. Moreover, 23Na MRI enhances the diagnostic capability of DWI and represents a novel, non-invasive biomarker of treatment response with superior sensitivity compared to DWI alone.


Asunto(s)
Neoplasias de la Mama , Sodio , Animales , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/tratamiento farmacológico , Medios de Contraste , Imagen de Difusión por Resonancia Magnética/métodos , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Ratones
3.
Small ; 18(13): e2104763, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35076148

RESUMEN

The survival strategies of infectious organisms have inspired many therapeutics over the years. Indeed the advent of oncolytic viruses (OVs) exploits the uncontrolled replication of cancer cells for production of their progeny resulting in a cancer-targeting treatment that leaves healthy cells unharmed. Their success against inaccessible tumors however, is highly variable due to inadequate tumor targeting following systemic administration. Coassembling herpes simplex virus (HSV1716) with biocompatible magnetic nanoparticles derived from magnetotactic bacteria enables tumor targeting from circulation with magnetic guidance, protects the virus against neutralizing antibodies and thereby enhances viral replication within tumors. This approach additionally enhances the intratumoral recruitment of activated immune cells, promotes antitumor immunity and immune cell death, thereby inducing tumor shrinkage and increasing survival in a syngeneic mouse model of breast cancer by 50%. Exploiting the properties of such a nanocarrier, rather than tropism of the virus, for active tumor targeting offers an exciting, novel approach for enhancing the bioavailability and treatment efficacy of tumor immunotherapies for disseminated neoplasms.


Asunto(s)
Herpesvirus Humano 1 , Neoplasias , Viroterapia Oncolítica , Animales , Bacterias , Línea Celular Tumoral , Ratones , Neoplasias/terapia , Viroterapia Oncolítica/métodos , Preparaciones Farmacéuticas
4.
Magn Reson Med ; 88(1): 11-27, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35253267

RESUMEN

PURPOSE: Enabling drug tracking (distribution/specific pathways) with magnetic resonance spectroscopy requires manipulation (via hyperpolarization) of spin state populations and targets with sufficiently long magnetic lifetimes to give the largest possible window of observation. Here, we demonstrate how the proton resonances of a group of thienopyridazines (with known anticancer properties), can be amplified using the para-hydrogen (p-H2 ) based signal amplification by reversible exchange (SABRE) hyperpolarization technique. METHODS: Thienopyridazine isomers, including a 2 H version, were synthesized in house. Iridium-based catalysts dissolved in a methanol-d4 solvent facilitated polarization transfer from p-H2 gas to the target thienopyridazines. Subsequent SABRE 1 H responses of hyperpolarized thienopyridazines were completed (400 MHz NMR). Pseudo-singlet state approaches were deployed to extend magnetic state lifetimes. Proof of principle spectral-spatial images were acquired across a range of field strengths (7T-9.4T MRI). RESULTS: 1 H-NMR signal enhancements of -10,130-fold at 9.4T (~33% polarization) were achieved on thieno[2,3-d]pyridazine (T[2,3-d]P), using SABRE under optimal mixing/field transfer conditions. 1 H T1 lifetimes for the thienopyridazines were ~18-50 s. Long-lived state approaches extended the magnetic lifetime of target proton sites in T[2,3-d]P from an average of 25-40 seconds. Enhanced in vitro imaging (spatial and chemical shift based) of target T[2,3-d]P was demonstrated. CONCLUSION: Here, we demonstrate the power of SABRE to deliver a fast and cost-effective route to hyperpolarization of important chemical motifs of anticancer agents. The SABRE approach outlined here lays the foundations for realizing continuous flow, hyperpolarized tracking of drug delivery/pathways.


Asunto(s)
Antineoplásicos , Protones , Hidrógeno/química , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética/métodos
5.
Neuroimage ; 237: 118195, 2021 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-34038769

RESUMEN

Cerebral blood volume (CBV) has been shown to be a robust and important physiological parameter for quantitative interpretation of functional (f)MRI, capable of delivering highly localized mapping of neural activity. Indeed, with recent advances in ultra-high-field (≥7T) MRI hardware and associated sequence libraries, it has become possible to capture non-invasive CBV weighted fMRI signals across cortical layers. One of the most widely used approaches to achieve this (in humans) is through vascular-space-occupancy (VASO) fMRI. Unfortunately, the exact contrast mechanisms of layer-dependent VASO fMRI have not been validated for human fMRI and thus interpretation of such data is confounded. Here we validate the signal source of layer-dependent SS-SI VASO fMRI using multi-modal imaging in a rat model in response to neuronal activation (somatosensory cortex) and respiratory challenge (hypercapnia). In particular VASO derived CBV measures are directly compared to concurrent measures of total haemoglobin changes from high resolution intrinsic optical imaging spectroscopy (OIS). Quantified cortical layer profiling is demonstrated to be in agreement between VASO and contrast enhanced fMRI (using monocrystalline iron oxide nanoparticles, MION). Responses show high spatial localisation to layers of cortical processing independent of confounding large draining veins which can hamper BOLD fMRI studies, (depending on slice positioning). Thus, a cross species comparison is enabled using VASO as a common measure. We find increased VASO based CBV reactivity (3.1 ± 1.2 fold increase) in humans compared to rats. Together, our findings confirm that the VASO contrast is indeed a reliable estimate of layer-specific CBV changes. This validation study increases the neuronal interpretability of human layer-dependent VASO fMRI as an appropriate method in neuroscience application studies, in which the presence of large draining intracortical and pial veins limits neuroscientific inference with BOLD fMRI.


Asunto(s)
Volumen Sanguíneo Cerebral/fisiología , Neuroimagen Funcional/normas , Imagen por Resonancia Magnética/normas , Corteza Somatosensorial/diagnóstico por imagen , Percepción del Tacto/fisiología , Adulto , Animales , Estimulación Eléctrica , Femenino , Humanos , Masculino , Imagen Óptica , Estimulación Física , Ratas , Reproducibilidad de los Resultados
7.
Angew Chem Int Ed Engl ; 58(30): 10271-10275, 2019 07 22.
Artículo en Inglés | MEDLINE | ID: mdl-31115970

RESUMEN

Hyperpolarisation methods that premagnetise agents such as pyruvate are currently receiving significant attention because they produce sensitivity gains that allow disease tracking and interrogation of cellular metabolism by magnetic resonance. Here, we communicate how signal amplification by reversible exchange (SABRE) can provide strong 13 C pyruvate signal enhancements in seconds through the formation of the novel polarisation transfer catalyst [Ir(H)2 (η2 -pyruvate)(DMSO)(IMes)]. By harnessing SABRE, strong signals for [1-13 C]- and [2-13 C]pyruvate in addition to a long-lived singlet state in the [1,2-13 C2 ] form are readily created; the latter can be observed five minutes after the initial hyperpolarisation step. We also demonstrate how this development may help with future studies of chemical reactivity.

8.
Neuroimage ; 171: 165-175, 2018 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-29294386

RESUMEN

Whether functional hyperemia during epileptic activity is adequate to meet the heightened metabolic demand of such events is controversial. Whereas some studies have demonstrated hyperoxia during ictal onsets, other work has reported transient hypoxic episodes that are spatially dependent on local surface microvasculature. Crucially, how laminar differences in ictal evolution can affect subsequent cerebrovascular responses has not been thus far investigated, and is likely significant in view of possible laminar-dependent neurovascular mechanisms and angioarchitecture. We addressed this open question using a novel multi-modal methodology enabling concurrent measurement of cortical tissue oxygenation, blood flow and hemoglobin concentration, alongside laminar recordings of neural activity, in a urethane anesthetized rat model of recurrent seizures induced by 4-aminopyridine. We reveal there to be a close relationship between seizure epicenter depth, translaminar local field potential (LFP) synchrony and tissue oxygenation during the early stages of recurrent seizures, whereby deep layer seizures are associated with decreased cross laminar synchrony and prolonged periods of hypoxia, and middle layer seizures are accompanied by increased cross-laminar synchrony and hyperoxia. Through comparison with functional activation by somatosensory stimulation and graded hypercapnia, we show that these seizure-related cerebrovascular responses occur in the presence of conserved neural-hemodynamic and blood flow-volume coupling. Our data provide new insights into the laminar dependency of seizure-related neurovascular responses, which may reconcile inconsistent observations of seizure-related hypoxia in the literature, and highlight a potential layer-dependent vulnerability that may contribute to the harmful effects of clinical recurrent seizures. The relevance of our findings to perfusion-related functional neuroimaging techniques in epilepsy are also discussed.


Asunto(s)
Encéfalo/irrigación sanguínea , Encéfalo/fisiopatología , Hiperoxia/fisiopatología , Convulsiones/fisiopatología , Animales , Circulación Cerebrovascular/fisiología , Femenino , Hemodinámica/fisiología , Ratas
9.
Neuroimage ; 146: 575-588, 2017 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-27646129

RESUMEN

It is generally recognised that event related potentials (ERPs) of electroencephalogram (EEG) primarily reflect summed post-synaptic activity of the local pyramidal neural population(s). However, it is still not understood how the positive and negative deflections (e.g. P1, N1 etc) observed in ERP recordings are related to the underlying excitatory and inhibitory post-synaptic activity. We investigated the neurogenesis of P1 and N1 in ERPs by pharmacologically manipulating inhibitory post-synaptic activity in the somatosensory cortex of rodent, and concurrently recording EEG and local field potentials (LFPs). We found that the P1 wave in the ERP and LFP of the supragranular layers is determined solely by the excitatory post-synaptic activity of the local pyramidal neural population, as is the initial segment of the N1 wave across cortical depth. The later part of the N1 wave was modulated by inhibitory post-synaptic activity, with its peak and the pulse width increasing as inhibition was reduced. These findings suggest that the temporal delay of inhibition with respect to excitation observed in intracellular recordings is also reflected in extracellular field potentials (FPs), resulting in a temporal window during which only excitatory post-synaptic activity and leak channel activity are recorded in the ERP and evoked LFP time series. Based on these findings, we provide clarification on the interpretation of P1 and N1 in terms of the excitatory and inhibitory post-synaptic activities of the local pyramidal neural population(s).


Asunto(s)
Ondas Encefálicas , Potenciales Evocados Somatosensoriales , Corteza Somatosensorial/fisiología , Animales , Electroencefalografía , Femenino , Inhibición Neural , Estimulación Física , Ratas , Percepción del Tacto/fisiología
10.
J Neurosci ; 35(11): 4641-56, 2015 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-25788681

RESUMEN

Studies that use prolonged periods of sensory stimulation report associations between regional reductions in neural activity and negative blood oxygenation level-dependent (BOLD) signaling. However, the neural generators of the negative BOLD response remain to be characterized. Here, we use single-impulse electrical stimulation of the whisker pad in the anesthetized rat to identify components of the neural response that are related to "negative" hemodynamic changes in the brain. Laminar multiunit activity and local field potential recordings of neural activity were performed concurrently with two-dimensional optical imaging spectroscopy measuring hemodynamic changes. Repeated measurements over multiple stimulation trials revealed significant variations in neural responses across session and animal datasets. Within this variation, we found robust long-latency decreases (300 and 2000 ms after stimulus presentation) in gamma-band power (30-80 Hz) in the middle-superficial cortical layers in regions surrounding the activated whisker barrel cortex. This reduction in gamma frequency activity was associated with corresponding decreases in the hemodynamic responses that drive the negative BOLD signal. These findings suggest a close relationship between BOLD responses and neural events that operate over time scales that outlast the initiating sensory stimulus, and provide important insights into the neurophysiological basis of negative neuroimaging signals.


Asunto(s)
Ritmo Gamma/fisiología , Hemodinámica/fisiología , Corteza Somatosensorial/fisiología , Animales , Estimulación Eléctrica/métodos , Femenino , Predicción , Ratas , Factores de Tiempo , Vibrisas/fisiología
11.
Neuroimage ; 124(Pt A): 794-805, 2016 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-26416648

RESUMEN

The blood oxygenation level-dependent (BOLD) signal is widely used for functional magnetic resonance imaging (fMRI) of brain function in health and disease. The statistical power of fMRI group studies is significantly hampered by high inter-subject variance due to differences in baseline vascular physiology. Several methods have been proposed to account for physiological vascularization differences between subjects and hence improve the sensitivity in group studies. However, these methods require the acquisition of additional reference scans (such as a full resting-state fMRI session or ASL-based calibrated BOLD). We present a vascular autorescaling (VasA) method, which does not require any additional reference scans. VasA is based on the observation that slow oscillations (<0.1Hz) in arterial blood CO2 levels occur naturally due to changes in respiration patterns. These oscillations yield fMRI signal changes whose amplitudes reflect the blood oxygenation levels and underlying local vascularization and vascular responsivity. VasA estimates proxies of the amplitude of these CO2-driven oscillations directly from the residuals of task-related fMRI data without the need for reference scans. The estimates are used to scale the amplitude of task-related fMRI responses, to account for vascular differences. The VasA maps compared well to cerebrovascular reactivity (CVR) maps and cerebral blood volume maps based on vascular space occupancy (VASO) measurements in four volunteers, speaking to the physiological vascular basis of VasA. VasA was validated in a wide variety of tasks in 138 volunteers. VasA increased t-scores by up to 30% in specific brain areas such as the visual cortex. The number of activated voxels was increased by up to 200% in brain areas such as the orbital frontal cortex while still controlling the nominal false-positive rate. VasA fMRI outperformed previously proposed rescaling approaches based on resting-state fMRI data and can be readily applied to any task-related fMRI data set, even retrospectively.


Asunto(s)
Circulación Cerebrovascular/fisiología , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Algoritmos , Mapeo Encefálico , Dióxido de Carbono/sangre , Reacciones Falso Positivas , Femenino , Voluntarios Sanos , Humanos , Hipercapnia/patología , Masculino , Oxígeno/sangre , Proyectos Piloto , Corteza Prefrontal/irrigación sanguínea , Mecánica Respiratoria/fisiología , Corteza Visual/irrigación sanguínea , Adulto Joven
12.
Neuroimage ; 107: 23-33, 2015 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-25479018

RESUMEN

Cortical layer-dependent high (sub-millimeter) resolution functional magnetic resonance imaging (fMRI) in human or animal brain can be used to address questions regarding the functioning of cortical circuits, such as the effect of different afferent and efferent connectivities on activity in specific cortical layers. The sensitivity of gradient echo (GE) blood oxygenation level-dependent (BOLD) responses to large draining veins reduces its local specificity and can render the interpretation of the underlying laminar neural activity impossible. The application of the more spatially specific cerebral blood volume (CBV)-based fMRI in humans has been hindered by the low sensitivity of the noninvasive modalities available. Here, a vascular space occupancy (VASO) variant, adapted for use at high field, is further optimized to capture layer-dependent activity changes in human motor cortex at sub-millimeter resolution. Acquired activation maps and cortical profiles show that the VASO signal peaks in gray matter at 0.8-1.6mm depth, and deeper compared to the superficial and vein-dominated GE-BOLD responses. Validation of the VASO signal change versus well-established iron-oxide contrast agent based fMRI methods in animals showed the same cortical profiles of CBV change, after normalization for lamina-dependent baseline CBV. In order to evaluate its potential of revealing small lamina-dependent signal differences due to modulations of the input-output characteristics, layer-dependent VASO responses were investigated in the ipsilateral hemisphere during unilateral finger tapping. Positive activation in ipsilateral primary motor cortex and negative activation in ipsilateral primary sensory cortex were observed. This feature is only visible in high-resolution fMRI where opposing sides of a sulcus can be investigated independently because of a lack of partial volume effects. Based on the results presented here, we conclude that VASO offers good reproducibility, high sensitivity and lower sensitivity than GE-BOLD to changes in larger vessels, making it a valuable tool for layer-dependent fMRI studies in humans.


Asunto(s)
Volumen Sanguíneo/fisiología , Encéfalo/anatomía & histología , Corteza Cerebral/anatomía & histología , Corteza Cerebral/fisiología , Circulación Cerebrovascular/fisiología , Adulto , Algoritmos , Animales , Vasos Sanguíneos/anatomía & histología , Corteza Cerebral/irrigación sanguínea , Vías Eferentes/anatomía & histología , Vías Eferentes/fisiología , Femenino , Compuestos Férricos , Dedos/inervación , Dedos/fisiología , Haplorrinos , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Masculino , Corteza Motora/anatomía & histología , Corteza Motora/fisiología , Movimiento/fisiología , Oxígeno/sangre , Ratas , Relación Señal-Ruido , Adulto Joven
13.
Neuroimage ; 97: 349-62, 2014 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-24742920

RESUMEN

Decreases in stimulus-dependent blood oxygenation level dependent (BOLD) signal and their underlying neurovascular origins have recently gained considerable interest. In this study a multi-echo, BOLD-corrected vascular space occupancy (VASO) functional magnetic resonance imaging (fMRI) technique was used to investigate neurovascular responses during stimuli that elicit positive and negative BOLD responses in human brain at 7 T. Stimulus-induced BOLD, cerebral blood volume (CBV), and cerebral blood flow (CBF) changes were measured and analyzed in 'arterial' and 'venous' blood compartments in macro- and microvasculature. We found that the overall interplay of mean CBV, CBF and BOLD responses is similar for tasks inducing positive and negative BOLD responses. Some aspects of the neurovascular coupling however, such as the temporal response, cortical depth dependence, and the weighting between 'arterial' and 'venous' contributions, are significantly different for the different task conditions. Namely, while for excitatory tasks the BOLD response peaks at the cortical surface, and the CBV change is similar in cortex and pial vasculature, inhibitory tasks are associated with a maximum negative BOLD response in deeper layers, with CBV showing strong constriction of surface arteries and a faster return to baseline. The different interplays of CBV, CBF and BOLD during excitatory and inhibitory responses suggests different underlying hemodynamic mechanisms.


Asunto(s)
Encéfalo/anatomía & histología , Imagen Eco-Planar/métodos , Oxígeno/sangre , Adulto , Animales , Vasos Sanguíneos/anatomía & histología , Vasos Sanguíneos/ultraestructura , Capilares/anatomía & histología , Capilares/ultraestructura , Circulación Cerebrovascular/fisiología , Movimientos Oculares/fisiología , Femenino , Haplorrinos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Neuronas/ultraestructura , Corteza Visual/anatomía & histología , Adulto Joven
14.
Neuroimage ; 97: 62-70, 2014 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-24736180

RESUMEN

Characterization of neural and hemodynamic biomarkers of epileptic activity that can be measured using non-invasive techniques is fundamental to the accurate identification of the epileptogenic zone (EZ) in the clinical setting. Recently, oscillations at gamma-band frequencies and above (>30 Hz) have been suggested to provide valuable localizing information of the EZ and track cortical activation associated with epileptogenic processes. Although a tight coupling between gamma-band activity and hemodynamic-based signals has been consistently demonstrated in non-pathological conditions, very little is known about whether such a relationship is maintained in epilepsy and the laminar etiology of these signals. Confirmation of this relationship may elucidate the underpinnings of perfusion-based signals in epilepsy and the potential value of localizing the EZ using hemodynamic correlates of pathological rhythms. Here, we use concurrent multi-depth electrophysiology and 2-dimensional optical imaging spectroscopy to examine the coupling between multi-band neural activity and cerebral blood volume (CBV) during recurrent acute focal neocortical seizures in the urethane-anesthetized rat. We show a powerful correlation between gamma-band power (25-90 Hz) and CBV across cortical laminae, in particular layer 5, and a close association between gamma measures and multi-unit activity (MUA). Our findings provide insights into the laminar electrophysiological basis of perfusion-based imaging signals in the epileptic state and may have implications for further research using non-invasive multi-modal techniques to localize epileptogenic tissue.


Asunto(s)
Volumen Sanguíneo/fisiología , Circulación Cerebrovascular/fisiología , Electroencefalografía , Ritmo Gamma , Neocórtex/fisiopatología , Convulsiones/fisiopatología , 4-Aminopiridina , Animales , Convulsivantes , Femenino , Imagen Óptica , Ratas , Recurrencia , Convulsiones/inducido químicamente
15.
Epilepsia ; 55(9): 1423-30, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25053117

RESUMEN

OBJECTIVE: Whether epileptic events disrupt normal neurovascular coupling mechanisms locally or remotely is unclear. We sought to investigate neurovascular coupling in an acute model of focal neocortical epilepsy, both within the seizure onset zone and in contralateral homotopic cortex. METHODS: Neurovascular coupling in both ipsilateral and contralateral vibrissal cortices of the urethane-anesthetized rat were examined during recurrent 4-aminopyridine (4-AP, 15 mm, 1 µl) induced focal seizures. Local field potential (LFP) and multiunit spiking activity (MUA) were recorded via two bilaterally implanted 16-channel microelectrodes. Concurrent two-dimensional optical imaging spectroscopy was used to produce spatiotemporal maps of cerebral blood volume (CBV). RESULTS: Recurrent acute seizures in right vibrissal cortex (RVC) produced robust ipsilateral increases in LFP and MUA activity, most prominently in layer 5, that were nonlinearly correlated to local increases in CBV. In contrast, contralateral left vibrissal cortex (LVC) exhibited relatively smaller nonlaminar specific increases in neural activity coupled with a decrease in CBV, suggestive of dissociation between neural and hemodynamic responses. SIGNIFICANCE: These findings provide insights into the impact of epileptic events on the neurovascular unit, and have important implications both for the interpretation of perfusion-based imaging signals in the disorder and understanding the widespread effects of epilepsy. A PowerPoint slide summarizing this article is available for download in the Supporting Information section here.


Asunto(s)
Mapeo Encefálico , Circulación Cerebrovascular/fisiología , Epilepsia/patología , Lateralidad Funcional/fisiología , Corteza Somatosensorial/fisiopatología , 4-Aminopiridina/toxicidad , Animales , Modelos Animales de Enfermedad , Electroencefalografía , Epilepsia/inducido químicamente , Femenino , Hemodinámica/fisiología , Bloqueadores de los Canales de Potasio/toxicidad , Ratas , Recurrencia , Estadísticas no Paramétricas
16.
Eur Radiol Exp ; 8(1): 75, 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38853182

RESUMEN

BACKGROUND: To study the reproducibility of 23Na magnetic resonance imaging (MRI) measurements from breast tissue in healthy volunteers. METHODS: Using a dual-tuned bilateral 23Na/1H breast coil at 3-T MRI, high-resolution 23Na MRI three-dimensional cones sequences were used to quantify total sodium concentration (TSC) and fluid-attenuated sodium concentration (FASC). B1-corrected TSC and FASC maps were created. Two readers manually measured mean, minimum and maximum TSC and mean FASC values using two sampling methods: large regions of interest (LROIs) and small regions of interest (SROIs) encompassing fibroglandular tissue (FGT) and the highest signal area at the level of the nipple, respectively. The reproducibility of the measurements and correlations between density, age and FGT apparent diffusion coefficient (ADC) values were evaluatedss. RESULTS: Nine healthy volunteers were included. The inter-reader reproducibility of TSC and FASC using SROIs and LROIs was excellent (intraclass coefficient range 0.945-0.979, p < 0.001), except for the minimum TSC LROI measurements (p = 0.369). The mean/minimum LROI TSC and mean LROI FASC values were lower than the respective SROI values (p < 0.001); the maximum LROI TSC values were higher than the SROI TSC values (p = 0.009). TSC correlated inversely with age but not with FGT ADCs. The mean and maximum FGT TSC and FASC values were higher in dense breasts in comparison to non-dense breasts (p < 0.020). CONCLUSIONS: The chosen sampling method and the selected descriptive value affect the measured TSC and FASC values, although the inter-reader reproducibility of the measurements is in general excellent. RELEVANCE STATEMENT: 23Na MRI at 3 T allows the quantification of TSC and FASC sodium concentrations. The sodium measurements should be obtained consistently in a uniform manner. KEY POINTS: • 23Na MRI allows the quantification of total and fluid-attenuated sodium concentrations (TSC/FASC). • Sampling method (large/small region of interest) affects the TSC and FASC values. • Dense breasts have higher TSC and FASC values than non-dense breasts. • The inter-reader reproducibility of TSC and FASC measurements was, in general, excellent. • The results suggest the importance of stratifying the sodium measurements protocol.


Asunto(s)
Mama , Imagen por Resonancia Magnética , Sodio , Humanos , Femenino , Reproducibilidad de los Resultados , Adulto , Imagen por Resonancia Magnética/métodos , Mama/diagnóstico por imagen , Persona de Mediana Edad , Isótopos de Sodio , Voluntarios Sanos , Variaciones Dependientes del Observador , Adulto Joven
17.
J Magn Reson Imaging ; 38(3): 739-44, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23677870

RESUMEN

PURPOSE: To establish procedures for functional MRI (fMRI) in rats without the need for anesthetic agents. MATERIALS AND METHODS: Rats were trained to habituate to restraint in a harness and scanner noise. Under anesthesia, rats were then prepared with a cranial implant that permitted stabilization of the head during subsequent imaging experiments. The cranial implant included an radiofrequency (RF) coil that was used to transmit and receive radiofrequency signals during imaging. Further training was then conducted to habituate the animals to head fixation whilst in the MR scanner. RESULTS: Using this method, we were able to successfully and repeatedly record BOLD fMRI responses to hypercapnia and whisker stimulation in awake rats. Electrical stimulation of the whisker pad produced a ∼7% increase in BOLD signal in the corresponding barrel cortex as well as adjacent negative BOLD responses, whilst hypercapnia produced larger increases in BOLD signal amplitude. CONCLUSION: This methodology leaves the face and limbs free from obstruction, making possible a range of behavioral or sensory stimulation protocols. Further development of this animal model could enable traditional behavioral neuroscience techniques to be combined with modern functional neuroimaging.


Asunto(s)
Potenciales Evocados Somatosensoriales/fisiología , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/veterinaria , Prótesis e Implantes , Corteza Somatosensorial/fisiología , Tacto/fisiología , Vibrisas/fisiología , Animales , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Ratas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Vibrisas/inervación
18.
Aging Cell ; 22(11): e14005, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37803929

RESUMEN

Mitochondrial function declines with age, and many pathological processes in neurodegenerative diseases stem from this dysfunction when mitochondria fail to produce the necessary energy required. Photobiomodulation (PBM), long-wavelength light therapy, has been shown to rescue mitochondrial function in animal models and improve human health, but clinical uptake is limited due to uncertainty around efficacy and the mechanisms responsible. Using 31 P magnetisation transfer magnetic resonance spectroscopy (MT-MRS) we quantify, for the first time, the effects of 670 nm PBM treatment on healthy ageing human brains. We find a significant increase in the rate of ATP synthase flux in the brain after PBM in a cohort of older adults. Our study provides initial evidence of PBM therapeutic efficacy for improving mitochondrial function and restoring ATP flux with age, but recognises that wider studies are now required to confirm any resultant cognitive benefits.


Asunto(s)
Adenosina Trifosfato , Encéfalo , Animales , Humanos , Anciano , Espectroscopía de Resonancia Magnética
19.
Nanotheranostics ; 7(1): 102-116, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36593801

RESUMEN

Delivering therapies to deeply seated brain tumours (BT) is a major clinical challenge. Magnetic drug targeting (MDT) could overcome this by rapidly transporting magnetised drugs directly into BT. We have developed a magnetic device for application in murine BT models using an array of neodymium magnets with a combined strength of 0.7T. In a closed fluidic system, the magnetic device trapped magnetic nanoparticles (MNP) up to distances of 0.8cm. In mice, the magnetic device guided intravenously administered MNP (<50nm) from the circulation into the brain where they localised within mouse BT. Furthermore, MDT of magnetised Temozolomide (TMZmag+) significantly reduced tumour growth and extended mouse survival to 48 days compared to the other treatment groups. Using the same principles, we built a proof of principle scalable magnetic device for human use with a strength of 1.1T. This magnetic device demonstrated trapping of MNP undergoing flow at distances up to 5cm. MDT using our magnetic device provides an opportunity for targeted delivery of magnetised drugs to human BT.


Asunto(s)
Neoplasias Encefálicas , Sistemas de Liberación de Medicamentos , Humanos , Ratones , Animales , Neoplasias Encefálicas/tratamiento farmacológico , Neoplasias Encefálicas/patología , Magnetismo , Temozolomida , Fenómenos Magnéticos
20.
Neuroimage ; 61(1): 10-20, 2012 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-22440642

RESUMEN

Traditionally functional magnetic resonance imaging (fMRI) has been used to map activity in the human brain by measuring increases in the Blood Oxygenation Level Dependent (BOLD) signal. Often accompanying positive BOLD fMRI signal changes are sustained negative signal changes. Previous studies investigating the neurovascular coupling mechanisms of the negative BOLD phenomenon have used concurrent 2D-optical imaging spectroscopy (2D-OIS) and electrophysiology (Boorman et al., 2010). These experiments suggested that the negative BOLD signal in response to whisker stimulation was a result of an increase in deoxy-haemoglobin and reduced multi-unit activity in the deep cortical layers. However, Boorman et al. (2010) did not measure the BOLD and haemodynamic response concurrently and so could not quantitatively compare either the spatial maps or the 2D-OIS and fMRI time series directly. Furthermore their study utilised a homogeneous tissue model in which is predominantly sensitive to haemodynamic changes in more superficial layers. Here we test whether the 2D-OIS technique is appropriate for studies of negative BOLD. We used concurrent fMRI with 2D-OIS techniques for the investigation of the haemodynamics underlying the negative BOLD at 7 Tesla. We investigated whether optical methods could be used to accurately map and measure the negative BOLD phenomenon by using 2D-OIS haemodynamic data to derive predictions from a biophysical model of BOLD signal changes. We showed that despite the deep cortical origin of the negative BOLD response, if an appropriate heterogeneous tissue model is used in the spectroscopic analysis then 2D-OIS can be used to investigate the negative BOLD phenomenon.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Neuroimagen/métodos , Oxígeno/sangre , Análisis Espectral/métodos , Animales , Mapeo Encefálico , Circulación Cerebrovascular/fisiología , Interpretación Estadística de Datos , Campos Electromagnéticos , Complejo IV de Transporte de Electrones/metabolismo , Femenino , Hemodinámica/fisiología , Hemoglobinas/análisis , Hemoglobinas/metabolismo , Histología , Procesamiento de Imagen Asistido por Computador , Modelos Neurológicos , Ratas , Respiración Artificial , Corteza Somatosensorial/irrigación sanguínea , Corteza Somatosensorial/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA