Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
RSC Adv ; 14(10): 7040-7051, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38414992

RESUMEN

Gas sensing technology has a broad impact on society, ranging from environmental and industrial safety to healthcare and everyday applications, contributing to a safer, healthier, and more sustainable world. We studied pure and Fe-decorated hexagonal boron nitride (h-BN) gas sensor for monitoring of carbon-based gases using density functional theory (DFT). The calculations utilized the Generalized Gradient Approximation with the Perdew-Burke-Ernzerhof (GGA-PBE) exchange-correlation functional. The novelty of our study lies in the investigation of the adsorption of harmful gases such as carbonyl sulfide, carbinol, carbimide, and carbonyl fluoride on both pure and Fe-decorated h-BN. The deviation in structural, electronic, and adsorption properties of h-BN due to Fe decoration has been studied along with the sensing ability to design said material towards carbon monoxide (CO), carbon dioxide (CO2), carbonyl sulfide (COS), carbinol, (CH4O), carbimide (CH2N2), and carbonyl fluoride (CF2O) gases. Gases such as CO, COS, CH2N2, and CF2O exhibited chemisorption, while CO2, and CH4O exhibited physisorption behavior. The introduction of Fe altered the semiconductor properties of h-BN and rendered it metallic. Enhanced electronic properties were observed due to a robust hybridization occurring between the d-orbitals of Fe-decorated BN and the gas molecules. The extended recovery periods observed for gases, aside from CO2, indicate their adhesive interactions with Fe-decorated h-BN. The reduction in desorption duration as temperature rises allows Fe-decorated h-BN to function as a reversible gas sensor. This research opens up a novel pathway for the synthesis and advancement of cost-effective, environmentally friendly double-atom catalysts with high sensitivity for capturing and detecting molecules such as CO, COS, CH2N2, CO2, CH4O, and CF2O.

2.
J Mol Model ; 29(8): 267, 2023 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-37526756

RESUMEN

INTRODUCTION: First-principles calculations were used to study the adsorption behavior of environmentally significant gases CO, CO2, NO, NO2, SO, and SO2 on pure buckled aluminene (b-Al) for gas sensing applications. Therefore, structural, electronic, and adsorption properties including adsorption energy values and recovery time have been calculated and discussed. METHODS: All the structures were optimized using Amsterdam Density Functional (ADF) code BAND. In addition, triple zeta polarization basis with slater-type orbitals were utilized. RESULTS: For every gas analyzed, we observed favorable adsorption energy values and charge transfer occurring between the gas molecule and b-Al. In the valance band, there was a strong hybridization between the p orbitals of gas and b-Al, this led to enhanced conductivity in the density of states (DOS). The recovery time suggested that the adsorption of NO, NO2, SO, and SO2 gases on b-Al is good for the application of reversible gas sensors. The recovery time indicated that the b-Al material is very sensitive to NO, NO2, SO, and SO2 gas molecules. CONCLUSION: The conclusion in light of all these results is that b-Al based materials can appear as a probable candidate for high gas sensing performance.

3.
J Mol Model ; 27(3): 78, 2021 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-33558970

RESUMEN

Deoxyribonucleic acid (DNA) drug intercalation is a well-known phenomenon for the treatment of cancer. Streptozotocin (STZ) is a drug agent containing toxic properties that make it good in the pancreatic cancer. The main objective of this study is the intercalation of the anticancer drug into the stacked base pair of DNA sequence with ATGC using a density functional theory (DFT) code named as ADF-Molecule. ADF code implements DFT using the Slater-type orbitals (STO) for computational analysis of atomic and molecular structures. All the calculations were carried out with the GGA and hybrid exchange correlation functional with TZ2P basis sets. It was captivatingly studied that during the intercalation process, the bonds between the DNA base pairs broken. Moreover, during the process of intercalation, the free radicals are considered responsible for disturbance in the base configurations. It was determined that the disturbances that occurred in the base pairs lead to discontinuity in the replication of that particular sequence in the DNA strand.


Asunto(s)
Emparejamiento Base , ADN/química , Sustancias Intercalantes/química , Estreptozocina/química , Teoría Funcional de la Densidad , Modelos Moleculares , Estructura Molecular , Conformación de Ácido Nucleico
4.
Curr Radiopharm ; 13(1): 80-85, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31258094

RESUMEN

BACKGROUND: 99mTc is a radioactive isotope that is obtained by eluting a 99Mo/99mTc generator. (PINSTECH, Islamabad) and used for radionuclide scanning. OBJECTIVES: The objective of this work is to study the uncertainties in 99mTc activity that exist due to time delay between injection preparation and administration to patients, during the process of gamma camera scanning. METHODS: Lead canisters were used for storing elution vials and dose calibrator for measuring 99mTc activity in mCi. The activity of preparing 99mTc injection and its administration to patients were compared with the prescribed values of activity recommended in the Society of Nuclear Medicine procedure guidelines. RESULTS: This study showed that uncertainty in the activity existed in one thyroid patient, 38 bone patients, 5 renal patients and 45 cardiac patients. CONCLUSION: This uncertainty in activity exists due to time delay between injection preparation and administration to patients, as well as due to residual radionuclide that is not injected into patients and remains in the syringe.


Asunto(s)
Huesos/diagnóstico por imagen , Corazón/diagnóstico por imagen , Riñón/diagnóstico por imagen , Radiofármacos , Tecnecio , Glándula Tiroides/diagnóstico por imagen , Humanos , Inyecciones , Medicina Nuclear , Generadores de Radionúclidos , Cintigrafía
5.
J Med Phys ; 41(3): 162-8, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27651562

RESUMEN

This study reviewed prostate volumetric-modulated arc therapy (VMAT) plans with intensity-modulated radiotherapy (IMRT) plans after prostate IMRT technique was replaced by VMAT in an institution. Characterizations of dosimetry and radiobiological variation in prostate were determined based on treatment plans of 40 prostate IMRT patients (planning target volume = 77.8-335 cm(3)) and 50 VMAT patients (planning target volume = 120-351 cm(3)) treated before and after 2013, respectively. Both IMRT and VMAT plans used the same dose-volume criteria in the inverse planning optimization. Dose-volume histogram, mean doses of target and normal tissues (rectum, bladder and femoral heads), dose-volume points (D99% of planning target volume; D30%, D50%, V30 Gy and V35 Gy of rectum and bladder; D5%, V14 Gy, V22 Gy of femoral heads), conformity index (CI), homogeneity index (HI), gradient index (GI), prostate tumor control probability (TCP), and rectal normal tissue complication probability (NTCP) based on the Lyman-Burman-Kutcher algorithm were calculated for each IMRT and VMAT plan. From our results, VMAT plan was found better due to its higher (1.05%) CI, lower (0.83%) HI and (0.75%) GI than IMRT. Comparing doses in normal tissues between IMRT and VMAT, it was found that IMRT mostly delivered higher doses of about 1.05% to the normal tissues than VMAT. Prostate TCP and rectal NTCP were found increased (1%) for VMAT than IMRT. It is seen that VMAT technique can decrease the dose-volume evaluation criteria for the normal tissues. Based on our dosimetric and radiobiological results in treatment plans, it is concluded that our VMAT implementation could produce comparable or slightly better target coverage and normal tissue sparing with a faster treatment time in prostate radiotherapy.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA