Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Am J Physiol Heart Circ Physiol ; 320(4): H1361-H1369, 2021 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-33481697

RESUMEN

Pulse wave velocity (PWV) is used to evaluate regional stiffness of large and medium-sized arteries. Here, we examine the feasibility and reliability of radial-digital PWV (RD-PWV) as a measure of regional stiffness of small conduit arteries and its response to changes in hydrostatic pressure. In 29 healthy subjects, we used Complior Analyse piezoelectric probes to record arterial pulse wave at the radial artery and the tip of the index. We determined transit time by second-derivative and intersecting tangents using the device-embedded algorithms and in-house MATLAB-based analyses of only reliable waves and by numerical simulation using a one-dimensional (1-D) arterial tree model coupled with a heart model. Second-derivative RD-PWV was 4.68 ± 1.18, 4.69 ± 1.21, and 4.32 ± 1.19 m/s for device-embedded, MATLAB-based, and numerical simulation analyses, respectively. Intersecting-tangent RD-PWV was 4.73 ± 1.20, 4.45 ± 1.08, and 4.50 ± 0.84 m/s for device-embedded, MATLAB-based, and numerical simulation analyses, respectively. Intersession coefficients of variation were 7.0% ± 4.9% and 3.2% ± 1.9% (P = 0.04) for device-embedded and MATLAB-based second-derivative algorithms, respectively. In 15 subjects, we examined the response of RD-PWV to changes in local hydrostatic pressure by vertical displacement of the hand. For an increase of 10 mmHg in local hydrostatic pressure, RD-PWV increased by 0.28 m/s (95% confidence interval: 0.16-0.40; P < 0.001). This study shows that RD-PWV can be used for the noninvasive assessment of regional stiffness of small conduit arteries. This finding allows for an integrated approach for assessing arterial stiffness gradient from the aorta to medium-sized arteries and now to small conduit arteries.NEW & NOTEWORTHY The interaction between the stiffness of various arterial segments is important in understanding the behavior of pressure and flow waves along the arterial tree. In this article, we provide a novel and noninvasive method of assessing the regional stiffness of small conduit arteries using the same piezoelectric sensors used for determination of pulse wave velocity over large- and medium-sized arteries. This development allows for an integrated approach for studying arterial stiffness gradient.


Asunto(s)
Presión Arterial , Dedos/irrigación sanguínea , Análisis de la Onda del Pulso , Arteria Radial/fisiología , Rigidez Vascular , Adulto , Algoritmos , Estudios Transversales , Estudios de Factibilidad , Femenino , Humanos , Presión Hidrostática , Masculino , Persona de Mediana Edad , Paris , Valor Predictivo de las Pruebas , Análisis de la Onda del Pulso/instrumentación , Quebec , Reproducibilidad de los Resultados , Procesamiento de Señales Asistido por Computador , Factores de Tiempo
2.
Eur Heart J ; 39(7): 599-606, 2018 02 14.
Artículo en Inglés | MEDLINE | ID: mdl-29281076

RESUMEN

Aims: People with exaggerated exercise blood pressure (BP) have adverse cardiovascular outcomes. Mechanisms are unknown but could be explained through impaired neural baroreflex sensitivity (BRS) and/or large artery stiffness. This study aimed to determine the associations of carotid BRS and carotid stiffness with exaggerated exercise BP. Methods and results: Blood pressure was recorded at rest and following an exercise step-test among 8976 adults aged 50 to 75 years from the Paris Prospective Study III. Resting carotid BRS (low frequency gain, from carotid distension rate, and heart rate) and stiffness were measured by high-precision echotracking. A systolic BP threshold of ≥ 150 mmHg defined exaggerated exercise BP and ≥140/90 mmHg defined resting hypertension (±antihypertensive treatment). Participants with exaggerated exercise BP had significantly lower BRS [median (Q1; Q3) 0.10 (0.06; 0.16) vs. 0.12 (0.08; 0.19) (ms2/mm) 2×108; P < 0.001] but higher stiffness [mean ± standard deviation (SD); 7.34 ± 1.37 vs. 6.76 ± 1.25 m/s; P < 0.001) compared to those with non-exaggerated exercise BP. However, only lower BRS (per 1SD decrement) was associated with exaggerated exercise BP among people without hypertension at rest {specifically among those with optimal BP; odds ratio (OR) 1.16 [95% confidence intervals (95% CI) 1.01; 1.33], P = 0.04 and high-normal BP; OR, 1.19 (95% CI 1.07; 1.32), P = 0.001} after adjustment for age, sex, body mass index, smoking, alcohol, total cholesterol, high-density lipoprotein cholesterol, resting heart rate, and antihypertensive medications. Conclusion: Impaired BRS, but not carotid stiffness, is independently associated with exaggerated exercise BP even among those with well controlled resting BP. This indicates a potential pathway from depressed neural baroreflex function to abnormal exercise BP and clinical outcomes.


Asunto(s)
Barorreflejo/fisiología , Presión Sanguínea/fisiología , Ejercicio Físico/fisiología , Hipertensión/fisiopatología , Rigidez Vascular/fisiología , Anciano , Arterias Carótidas/fisiopatología , Prueba de Esfuerzo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
3.
Hypertension ; 81(9): 1986-1995, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38934112

RESUMEN

BACKGROUND: Carotid-femoral pulse wave velocity (cfPWV) is the gold standard for noninvasive arterial stiffness assessment, an independent predictor of cardiovascular disease, and a potential parameter to guide therapy. However, cfPWV is not routinely measured in clinical practice due to the unavailability of a low-cost, operator-friendly, and independent device. The current study validated a novel laser Doppler vibrometry (LDV)-based measurement of cfPWV against the reference technique. METHODS: In 100 (50 men) hypertensive patients, cfPWV was measured using applanation tonometry (Sphygmocor) and the novel LDV device. This device has 2 handpieces with 6 laser beams each that simultaneously measure vibrations from the skin surface at carotid and femoral sites. Pulse wave velocity is calculated using ECG for the identification of cardiac cycles. An ECG-independent method was also devised. Cardiovascular risk score was calculated for patients between 40 and 75 years old using the WHO risk scoring chart. RESULTS: LDV-based cfPWV correlated significantly with tonometry (r=0.86, P<0.0001 ECG-dependent [cfPWVLDV_ECG] and r=0.80, P<0.001 ECG-independent [cfPWVLDV_w/oECG] methods). Bland-Altman analysis showed nonsignificant bias (0.65 m/s) and acceptable SD (1.27 m/s) between methods. Intraobserver coefficient of variance for LDV was 4.7% (95% CI, 3.0%-5.5%), and interobserver coefficient of variance was 5.87%. CfPWV correlated significantly with CVD risk (r=0.64, P<0.001; r=0.41, P=0.003; and r=0.37, P=0.006 for tonometry, LDV-with, and LDV-without ECG, respectively). CONCLUSIONS: The study demonstrates clinical validity of the LDV device. The LDV provides a simple, noninvasive, operator-independent method to measure cfPWV for assessing arterial stiffness, comparable to the standard existing techniques. REGISTRATION: URL: https://clinicaltrials.gov/study/NCT03446430; Unique identifier: NCT03446430.


Asunto(s)
Velocidad de la Onda del Pulso Carotídeo-Femoral , Rigidez Vascular , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermedades Cardiovasculares/fisiopatología , Enfermedades Cardiovasculares/diagnóstico , Arterias Carótidas/fisiopatología , Velocidad de la Onda del Pulso Carotídeo-Femoral/métodos , Arteria Femoral/fisiopatología , Hipertensión/fisiopatología , Hipertensión/diagnóstico , Manometría/métodos , Manometría/instrumentación , Análisis de la Onda del Pulso/métodos , Análisis de la Onda del Pulso/instrumentación , Reproducibilidad de los Resultados , Rigidez Vascular/fisiología , Vibración
4.
J Clin Med ; 11(7)2022 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-35407581

RESUMEN

High blood pressure is the number one killer in the world. About 1.5 billion people suffered from hypertension in 2010, and these numbers are increasing year by year. The basics of the management of high blood pressure are described in the Canadian, American, International and European guidelines for hypertension. However, there are similarities and differences in the definition, measurement and management of blood pressure between these different guidelines. According to the Canadian guidelines, normal blood pressure is less than 140/90 mmHg (systolic blood pressure/diastolic blood pressure). The AHA and ESC estimate normal blood pressure to be less than 120/80 mmHg (systolic blood pressure/diastolic blood pressure). Regarding treatments, the AHA, ISH and ESC are also in agreement about dual therapy as the first-line therapy, while Canadian recommendations retain the idea of monotherapy as the initiation of treatment. When it comes to measuring blood pressure, the four entities agree on the stratification of intervention in absolute cardiovascular risk.

5.
J Hypertens ; 40(10): 2058-2067, 2022 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-36052527

RESUMEN

BACKGROUND: The long-term cardiovascular consequences of microgravity on large arteries are a threat for long-term space missions. We hypothesized that changes in arterial properties differ according to the arterial territory (upper or lower body), and arterial structure (elastic vs. muscular arteries), in response to 60-day head-down bed rest (HDBR). METHOD: Twenty healthy male volunteers were included and received a daily multivitamin supplementation in a double-blind fashion. At baseline, 29 and 52 days during strict HDBR, then 12 and 30 days after HDBR, aortic stiffness was measured using carotid-to-femoral pulse wave velocity (cf-PWV) and aortic MRI. Carotid, femoral, brachial and popliteal arteries were studied by ultrasound echo tracking, central blood pressure (BP) by tonometry and endothelial function by flow-mediated dilatation. RESULTS: Cf-PWV increased during HDBR (+0.8 and +1.1m/s, at D29 and D52, respectively, P = 0.004), corresponding to an increase in vascular age up to +11 years (P = 0.003). Changes were similar to those observed on MRI (+0.8 m/s at D52, P < 0.01) and were independent of BP and heart rate changes. After HDBR, cf-PWV showed a substantial recovery at R12 but still remained higher than baseline at R30 (+0.8 m/s, P = 0.018), corresponding to +6.5 years of vascular aging (P = 0.018). Thoracic aorta diameter increased significantly (+6%, P = 0.0008). During HDBR, femoral and popliteal arteries showed dimensional changes, leading to femoral inward hypotrophic remodeling (femoral diameter: -12%, P < 0.05; wall cross-sectional area: -25%, P = 0.014) and popliteal inward eutrophic remodeling (popliteal diameter: -25%, P < 0.05; wall cross-sectional area: -3%, P = 0.51). After HDBR, both arterial territories of the leg recovered. We did not observe any significant changes for carotid arteries nor for endothelial function during and after HDBR. Multivitamin supplementation did not affect vascular changes. HDBR was associated with an important increase in aortic stiffness, which did not completely recover 1 month after the end of HDBR. The thoracic aorta and the lower body muscular arteries underwent significant changes in dimensions whereas the common carotid arteries were preserved. CONCLUSION: These results should raise caution for those exposed to microgravity, real or simulated.


Asunto(s)
Reposo en Cama , Rigidez Vascular , Reposo en Cama/efectos adversos , Presión Sanguínea , Arterias Carótidas , Método Doble Ciego , Humanos , Masculino , Análisis de la Onda del Pulso
6.
Hypertension ; 79(1): 93-103, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34788057

RESUMEN

Fibromuscular dysplasia (FMD), a nonatherosclerotic, noninflammatory disease of medium-sized arteries, is an underdiagnosed disease. We investigated the urinary proteome and developed a classifier for discrimination of FMD from healthy controls and other diseases. We further hypothesized that urinary proteomics biomarkers may be associated with alterations in medium-sized, but not large artery geometry and mechanics. The study included 33 patients with mostly multifocal, renal FMD who underwent in depth arterial exploration using ultra-high frequency ultrasound. The cohort was separated in a training set of 23 patients with FMD from Belgium and an independent test set of 10 patients with FMD from Italy. For each set, controls matched 2:1 were selected from the Human Urinary Proteome Database. The specificity of the classifier was tested in 700 additional controls from general population studies, patients with chronic kidney disease (n=66) and coronary artery disease (n=31). Three hundred thirty-five urinary peptides, mostly related to collagen turnover, were identified in the training cohort and combined into a classifier. When applying in the test cohort, the area under the receiver operating characteristic curve was 1.00, 100% specificity at 100% sensitivity. The classifier maintained a high specificity in additional controls (98.3%), patients with chronic kidney (90.9%) and coronary artery (96.8%) diseases. Furthermore, in patients with FMD, the proteomic score was positively associated with radial wall thickness and wall cross-sectional area. In conclusion, a proteomic score has the potential to discriminate between patients with FMD and controls. If confirmed in a wider and more diverse cohort, these findings may pave the way for a noninvasive diagnostic test of FMD.


Asunto(s)
Colágeno/orina , Displasia Fibromuscular/orina , Adulto , Anciano , Enfermedad de la Arteria Coronaria/patología , Enfermedad de la Arteria Coronaria/orina , Femenino , Displasia Fibromuscular/patología , Humanos , Masculino , Persona de Mediana Edad , Proteómica , Insuficiencia Renal Crónica/patología , Insuficiencia Renal Crónica/orina , Sensibilidad y Especificidad
7.
Ultrasound Med Biol ; 48(4): 711-716, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35058069

RESUMEN

Ultrahigh-frequency ultrasound (UHFUS) allows sharp visualization of human small muscular arteries. This may help in elucidating some aspects of the pathophysiology of arterial aging, such as the stiffness gradient between large and small conduit arteries and its consequences on the microcirculation, as well as vascular diseases affecting medium-sized arteries. However, UHFUS use is still limited, partly because of the lack of validated tools to quantify vascular structure and mechanical properties of small muscular arteries. In this validation study, scans of digital arteries were obtained with UHFUS (VevoMD, Visualsonics-Fujifilm, Toronto, ON, Canada), analyzed using Carotid Studio software (Quipu, Pisa, Italy) and compared with the manual measurement. Agreement between the two techniques on measures of diameter, distension and intima-media thickness (IMT) was evaluated using Bland-Altman analyses; inter- and intra-operator reproducibility was evaluated using coefficients of variation (CVs). Overall, no trend or significant bias was observed between Carotid Studio and manual analysis. All limits of agreement were acceptable. The intra-observer CV of diastolic diameter and IMT were 4.1% and 4.2%, respectively. The inter-observer CV for diastolic diameter and IMT were 7.3% and 5.4%, respectively. Intra- and inter-observer CVs for distension were higher (25.7% and 26.7%, respectively). These results suggest that the Carotid Studio software is a valid and reproducible tool to study UHFUS scans of digital arteries, with potential utility both in rare vascular diseases of medium-sized arteries and in the study of the pathophysiology of arterial aging in general.


Asunto(s)
Arterias Carótidas , Grosor Intima-Media Carotídeo , Arterias Carótidas/diagnóstico por imagen , Estudios de Factibilidad , Humanos , Reproducibilidad de los Resultados , Ultrasonografía/métodos
8.
Am J Clin Nutr ; 115(3): 694-704, 2022 03 04.
Artículo en Inglés | MEDLINE | ID: mdl-34791007

RESUMEN

BACKGROUND: The effects of a dietary supplementation with the vegetable ω-3 α-linolenic acid (ALA) on cardiovascular homeostasis are unclear. In this context, it would be interesting to assess the effects of camelina oil. OBJECTIVE: This study aimed to assess the cardiovascular and metabolic effects of camelina oil in hypertensive patients with metabolic syndrome. METHODS: In a double-blind, placebo-controlled randomized study, treated essential hypertensive patients with metabolic syndrome received, during 6 mo, either cyclodextrin-complexed camelina oil containing ≈ 1.5 g ALA/d (n = 40) or an isocaloric placebo (n = 41), consisting of the same quantity of cyclodextrins and wheat starch. Anthropometric data, plasma lipids, glycemia, insulinemia, creatininemia, TBARs, high-sensitivity C-reactive protein, and n-3, n-6, and n-9 fatty acids in erythrocyte membranes were measured. Peripheral and central blood pressures, arterial stiffness, carotid intima-media thickness, and brachial artery endothelium-dependent flow-mediated dilatation (FMD) and endothelium-independent dilatation were assessed. RESULTS: Compared with placebo, camelina oil increased ALA (mean ± SD: 0 ± 0.04 compared with 0.08 ± 0.06%, P <0.001), its elongation product EPA (0 ± 0.5 compared with 0.16 ± 0.65%, P <0.05), and the n-9 gondoic acid (GA; 0 ± 0.04 compared with 0.08 ± 0.04%, P <0.001). No between-group difference was observed for cardiovascular parameters. However, changes in FMD were associated with the magnitude of changes in EPA (r = 0.26, P = 0.03). Compared with placebo, camelina oil increased fasting glycemia (-0.2 ± 0.6 compared with 0.3 ± 0.5 mmol/L, P <0.001) and HOMA-IR index (-0.8 ± 2.5 compared with 0.5 ± 0.9, P <0.01), without affecting plasma lipids, or inflammatory and oxidative stress markers. Changes in HOMA-IR index were correlated with the magnitude of changes in GA (r = 0.32, P <0.01). Nutritional intake remained similar between groups. CONCLUSION: ALA supplementation with camelina oil did not improve vascular function but adversely affected glucose metabolism in hypertensive patients with metabolic syndrome. Whether this adverse effect on insulin sensitivity is related to GA enrichment, remains to be elucidated.


Asunto(s)
Ácidos Grasos Omega-3 , Hipertensión , Síndrome Metabólico , Grosor Intima-Media Carotídeo , Método Doble Ciego , Ácidos Grasos Omega-3/farmacología , Humanos , Hipertensión/tratamiento farmacológico , Síndrome Metabólico/tratamiento farmacológico
9.
ESC Heart Fail ; 8(3): 2232-2239, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33773099

RESUMEN

AIMS: Myocardial injury is frequently observed in patients hospitalized with coronavirus disease 2019 (COVID-19) pneumonia. Different cardiac abnormalities have been reported during the acute COVID-19 phase, ranging from infra-clinic elevations of myocardial necrosis biomarkers to acute cardiac dysfunction and myocarditis. There is limited information on late cardiac sequelae in patients who have recovered from acute COVID-19 illness. We aimed to document the presence and quantify the extent of myocardial functional alterations in patients hospitalized 6 months earlier for COVID-19 infection. METHODS AND RESULTS: We conducted a prospective echocardiographic evaluation of 48 patients (mean age 58 ± 13 years, 69% male) hospitalized 6 ± 1 month earlier for a laboratory-confirmed and symptomatic COVID-19. Thirty-two (66.6%) had pre-existing cardiovascular risks factors (systemic hypertension, diabetes, or dyslipidaemia), and three patients (6.2%) had a known prior myocardial infarction. Sixteen patients (33.3%) experienced myocardial injury during the index COVID-19 hospitalization as identified by a rise in cardiac troponin levels. Six months later, 60.4% of patients still reported clinical symptoms including exercise dyspnoea for 56%. Echocardiographic measurements under resting conditions were not different between patients with versus without myocardial injury during the acute COVID-19 phase. In contrast, low-level exercise (25W for 3 min) induced a significant increase in the average E/e' ratio (10.1 ± 4.3 vs. 7.3 ± 11.5, P = 0.01) and the systolic pulmonary artery pressure (33.4 ± 7.8 vs. 25.6 ± 5.3 mmHg, P = 0.02) in patients with myocardial injury during the acute COVID-19 phase. Sensitivity analyses showed that these alterations of left ventricular diastolic markers were observed regardless of whether of cardiovascular risk factors or established cardiac diseases indicating SARS-CoV-2 infection as a primary cause. CONCLUSIONS: Six months after the acute COVID-19 phase, significant cardiac diastolic abnormalities are observed in patients who experienced myocardial injury but not in patients without cardiac involvement.


Asunto(s)
COVID-19 , Anciano , Femenino , Estudios de Seguimiento , Corazón , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , SARS-CoV-2
12.
Biomed Opt Express ; 11(7): 3913-3926, 2020 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-33014575

RESUMEN

Pulse wave velocity (PWV) is a reference measure for aortic stiffness, itself an important biomarker of cardiovascular risk. To enable low-cost and easy-to-use PWV measurement devices that can be used in routine clinical practice, we have designed several handheld PWV sensors using miniaturized laser Doppler vibrometer (LDV) arrays in a silicon photonics platform. The LDV-based PWV sensor design and the signal processing protocol to obtain pulse transit time (PTT) and carotid-femoral PWV in a feasibility study in humans, are described in this paper. Compared with a commercial reference PWV measurement system, measuring arterial pressure waveforms by applanation tonometry, LDV-based displacement signals resulted in more complex signals. However, we have shown that it is possible to identify reliable fiducial points for PTT calculation using the maximum of the 2nd derivative algorithm in LDV-based signals, comparable to those obtained by the reference technique, applanation tonometry.

14.
J Hypertens ; 37(7): 1448-1454, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31145713

RESUMEN

OBJECTIVES: Aortic distensibility estimation of local aortic stiffness is based on local aortic strains and central pulse pressure (cPP) measurements. Most MRI studies used either brachial PP (bPP) despite differences with cPP, or direct cPP estimates obtained after MRI examination, assuming no major pressure variations. We evaluated the feasibility of assessment of cPP with a specific device fitted with a 6 m long hose (study1) and looked at the influence of using such cPP within the magnet instead of bPP on aortic distensibility in a control population (study 2). METHODS: Brachial and central pressures values were recorded with the SphygmoCor XCEL system fitted with 2 and 6 m long tubing randomly assigned on arms. A 6 m long tubing was used in the second study to measure aortic distensibility with MRI. Aortic distensibility was calculated using either bPP (bAD) or cPP (cAD). RESULTS: Study1, performed on 38 patients (mean age: 43 ±â€Š17 years), showed no statistical difference between bPP and cPP measured with 2 or 6 m long tubing (0.41 ±â€Š4.45 and 0.78 ±â€Š3.18 mmHg, respectively, both P = ns). In study 2, cAD provided statistically higher values than bAD (1.87 ±â€Š1.43 10 ·â€ŠmmHg, P < 0.001) especially in younger individuals (3.28 ±â€Š0.86 10 ·â€ŠmmHg). The correlation between age and aortic distensibility was stronger with cAD (r = -0.92; P < 0,001) than with bAD (r = -0.88; P < 0.001). CONCLUSION: cPP can be estimated with reasonable accuracy during MRI acquisition using a 6 m long tube. Using either cPP or bPP greatly influences aortic distensibility values, especially in young individuals in whom an accurate detection of early or accelerated vascular aging can be of major importance.


Asunto(s)
Envejecimiento , Aorta/fisiopatología , Determinación de la Presión Sanguínea/instrumentación , Presión Sanguínea , Imagen por Resonancia Magnética , Rigidez Vascular , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad
15.
Hypertension ; 73(2): 371-378, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30624987

RESUMEN

Arterial fibromuscular dysplasia is a nonatherosclerotic, noninflammatory vascular disease, whose pathophysiology is still unknown. We performed deep image-based vascular phenotyping of nonaffected arteries to look for systemic vascular alterations in fibromuscular dysplasia. This single center cross-sectional study included 50 patients with multifocal renal fibromuscular dysplasia, 50 hypertensive patients, and 50 healthy controls, matched for age, sex, and ethnicity; hypertensive patients were matched also for blood pressure. Brachial artery endothelium-dependent and endothelium-independent dilation were studied by echotracking. Aortic stiffness was assessed by carotid-to-femoral pulse wave velocity. We quantified the presence of supernumerary acoustic interfaces within the common carotid wall by the triple signal (TS) score. We plotted the Young incremental elastic modulus/stress curves for common carotid artery, derived from echotracking and tonometry. Patients with fibromuscular dysplasia had impaired endothelium-independent dilation (adjusted P=0.002), smaller brachial artery diameter but comparable endothelium-dependent dilation and aortic stiffness. The prevalence of TS score >6 was 56%, 40%, 24% in patients with fibromuscular dysplasia, hypertensives, and controls, respectively ( P=0.005). Fibromuscular dysplasia remained significantly associated with TS in the multiple regression model ( P=0.022). Impaired endothelium-dependent dilation was present only in patients with fibromuscular dysplasia, TS score >6 ( P=0.047). Incremental elastic modulus was higher for a given wall stress (80 kPa) in the presence of a TS score >6, especially in fibromuscular dysplasia. In conclusion, nonclinically affected large- and medium-sized arteries in patients with multifocal renal fibromuscular dysplasia exhibit a cluster of diffuse alterations in smooth muscle cell function, arterial geometry, wall characteristics, and mechanical properties. Clinical Trial Registration URL: http://www.clinicaltrials.gov . Unique identifier: NCT01935752.


Asunto(s)
Displasia Fibromuscular/fisiopatología , Riñón/irrigación sanguínea , Arteria Braquial/fisiopatología , Estudios Transversales , Endotelio Vascular/fisiología , Femenino , Humanos , Hipertensión/fisiopatología , Masculino , Persona de Mediana Edad , Miocitos del Músculo Liso/fisiología , Fenotipo , Rigidez Vascular
16.
Ultrasound Med Biol ; 45(3): 758-772, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30642659

RESUMEN

Shear wave elastography and ultrafast imaging of the carotid artery pulse wave were performed in 27 normotensive participants and 29 age- and sex-matched patients with essential hypertension, and compared with reference techniques: carotid-femoral pulse wave velocity (cfPWV) determined via arterial tonometry and carotid stiffness (carPWV) determined via echotracking. Shear wave speed in the carotid anterior (a-SWS) and posterior (p-SWS) walls were assessed throughout the cardiac cycle. Ultrafast PWV was measured in early systole (ufPWV-FW) and in end-systole (dicrotic notch, ufPWV-DN). Shear wave speed in the carotid anterior appeared to be the best candidate to evaluate arterial stiffness from ultrafast imaging. In univariate analysis, a-SWS was associated with carPWV (r = 0.56, p = 0.003) and carotid-to-femoral PWV (r = 0.66, p < 0.001). In multivariate analysis, a-SWS was independently associated with age (R²â€¯= 0.14, p = 0.02) and blood pressure (R²â€¯= 0.21, p = 0.004). Moreover, a-SWS increased with blood pressure throughout the cardiac cycle and did not differ between normotensive participants and patients with essential hypertension when compared at similar blood pressures.


Asunto(s)
Presión Sanguínea/fisiología , Arterias Carótidas/fisiopatología , Diagnóstico por Imagen de Elasticidad/métodos , Hipertensión/fisiopatología , Análisis de la Onda del Pulso/métodos , Rigidez Vascular/fisiología , Adulto , Anciano , Arterias Carótidas/diagnóstico por imagen , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valores de Referencia , Reproducibilidad de los Resultados
17.
J Hypertens ; 35(8): 1618-1625, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28379892

RESUMEN

BACKGROUND: Carotid-femoral pulse wave velocity (PWV) (cf-PWV) is the gold standard for measuring aortic stiffness. Finger-toe PWV (ft-PWV) is a simpler noninvasive method for measuring arterial stiffness. Although the validity of the method has been previously assessed, its accuracy can be improved. ft-PWV is determined on the basis of a patented height chart for the distance and the pulse transit time (PTT) between the finger and the toe pulpar arteries signals (ft-PTT). METHOD: The objective of the first study, performed in 66 patients, was to compare different algorithms (intersecting tangents, maximum of the second derivative, 10% threshold and cross-correlation) for determining the foot of the arterial pulse wave, thus the ft-PTT. The objective of the second study, performed in 101 patients, was to investigate different signal processing chains to improve the concordance of ft-PWV with the gold-standard cf-PWV. Finger-toe PWV (ft-PWV) was calculated using the four algorithms. RESULTS: The best correlations relating ft-PWV and cf-PWV, and relating ft-PTT and carotid-femoral PTT were obtained with the maximum of the second derivative algorithm [PWV: r = 0.56, P < 0.0001, root mean square error (RMSE) = 0.9 m/s; PTT: r = 0.61, P < 0.001, RMSE = 12 ms]. The three other algorithms showed lower correlations. The correlation between ft-PTT and carotid-femoral PTT further improved (r = 0.81, P < 0.0001, RMSE = 5.4 ms) when the maximum of the second derivative algorithm was combined with an optimized signal processing chain. CONCLUSION: Selecting the maximum of the second derivative algorithm for detecting the foot of the pressure waveform, and combining it with an optimized signal processing chain, improved the accuracy of ft-PWV measurement in the current population sample. Thus, it makes ft-PWV very promising for the simple noninvasive determination of aortic stiffness in clinical practice.


Asunto(s)
Enfermedad de la Arteria Coronaria/fisiopatología , Análisis de la Onda del Pulso , Adulto , Anciano , Algoritmos , Velocidad del Flujo Sanguíneo , Estudios de Casos y Controles , Femenino , Dedos/irrigación sanguínea , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Análisis de la Onda del Pulso/métodos , Reproducibilidad de los Resultados , Procesamiento de Señales Asistido por Computador , Dedos del Pie/irrigación sanguínea , Adulto Joven
18.
Am J Hypertens ; 30(9): 876-883, 2017 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-28520843

RESUMEN

BACKGROUND: Measurement of arterial stiffness should be more available. Our aim was to show that aortic pulse wave velocity can be reliably measured with a bathroom scale combining the principles of ballistocardiography (BCG) and impedance plethysmography on a single foot. METHOD: The calibration of the bathroom scale was conducted on a group of 106 individuals. The aortic pulse wave velocity was measured with the SphygmoCor in the supine position. Three consecutive measurements were then performed on the Withings scale in the standing position. This aorta-leg pulse transit time (alPTT) was then converted into a velocity with the additional input of the height of the person. Agreement between the SphygmoCor and the bathroom scale so calibrated is assessed on a separate group of 86 individuals, following the same protocol. RESULTS: The bias is 0.25 m·s-1 and the SE 1.39 m·s-1. This agreement with Sphygmocor is "acceptable" according to the ARTERY classification. The alPTT correlated well with cfPTT with (Spearman) R = 0.73 in pooled population (cal 0.79, val 0.66). The aorta-leg pulse wave velocity correlated with carotid-femoral pulse wave velocity with R = 0.76 (cal 0.80, val 0.70). CONCLUSION: Estimation of the aortic pulse wave velocity is feasible with a bathroom scale. Further investigations are needed to improve the repeatability of measurements and to test their accuracy in different populations and conditions.


Asunto(s)
Antropometría/instrumentación , Balistocardiografía/instrumentación , Peso Corporal , Enfermedades Cardiovasculares/diagnóstico , Pletismografía de Impedancia/instrumentación , Análisis de la Onda del Pulso/instrumentación , Rigidez Vascular , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Balistocardiografía/normas , Presión Sanguínea , Estatura , Calibración , Enfermedades Cardiovasculares/fisiopatología , Diseño de Equipo , Femenino , Pie , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Modelos Cardiovasculares , Pletismografía de Impedancia/normas , Valor Predictivo de las Pruebas , Análisis de la Onda del Pulso/normas , Reproducibilidad de los Resultados , Adulto Joven
19.
Arch Cardiovasc Dis ; 108(4): 227-34, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25682547

RESUMEN

BACKGROUND: The finger-toe pathway could be a good alternative for assessing arterial stiffness conveniently. AIM: To evaluate the accuracy of the pOpmètre®--a new device that measures finger-toe pulse wave velocity (ft-PWV). METHODS: The pOpmètre has two photodiode sensors, positioned on the finger and the toe. Pulse waves are recorded continuously for 20 seconds, and the difference in pulse wave transit time between toe and finger (ft-TT) is calculated. The travelled distance is estimated using subject height. Study 1 compared ft-PWV with carotid-femoral PWV (cf-PWV) obtained by the reference method (SphygmoCor®) in 86 subjects (mean age 53±20 years), including 69 patients with various pathologies and 17 healthy normotensives. Study 2 compared changes in ft-PWV and cf-PWV during a cold pressor test in 10 healthy subjects. Study 3 assessed repeatability in 45 patients. RESULTS: ft-PWV correlated significantly with cf-PWV (R2=0.43; P<0.0001). A better correlation was found in terms of transit time (R2=0.61; P<0.0001). The discrepancy between transit times was related to age. The cold pressor test induced parallel changes in cf-PWV and ft-PWV, with increased aortic stiffness that was reversible during recovery. Intra-session repeatability was very good, with a coefficient of variation of 4.52%. CONCLUSION: The pOpmètre® allows measurement of arterial stiffness in routine clinical practice. The greatest advantages of ft-PWV are simplicity, rapidity, feasibility, acceptability by patients and correct agreement with the reference technique. Further studies are needed to adjust for bias and to validate the pOpmètre in larger populations.


Asunto(s)
Dedos/irrigación sanguínea , Análisis de la Onda del Pulso/instrumentación , Dedos del Pie/irrigación sanguínea , Rigidez Vascular , Adulto , Anciano , Anciano de 80 o más Años , Velocidad del Flujo Sanguíneo , Estudios de Casos y Controles , Trastornos del Conocimiento/fisiopatología , Frío , Diseño de Equipo , Femenino , Francia , Humanos , Hipertensión/fisiopatología , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Flujo Sanguíneo Regional , Reproducibilidad de los Resultados , Factores de Tiempo , Adulto Joven
20.
J Hypertens ; 32(4): 873-80, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24509122

RESUMEN

BACKGROUND: The Complior device (Alam Medical, France) was used in epidemiological studies which established pulse wave velocity (PWV) as a cardiovascular risk marker. Central pressure is related, but complementary to PWV and also associated to cardiovascular outcomes. The new Complior Analyse measures both PWV and central blood pressure during the same acquisition. The aim of this study was to compare PWV values from Complior Analyse with the previous Complior SP (PWVcs) and with Sphygmocor (PWVscr; AtCor, Australia), and to compare central systolic pressure from Complior Analyse and Sphygmocor. METHOD: Peripheral and central pressures and PWV were measured with the three devices in 112 patients. PWV measurements from Complior Analyse were analysed using two foot-detection algorithms (PWVca_it and PWVca_cs). Both radial (ao-SBPscr) and carotid (car-SBPscr) approaches from Sphygmocor were compared to carotid Complior Analyse measurements (car-SBPca). The same distance and same calibrating pressures were used for all devices. RESULTS: PWVca_it was strongly correlated to PWVscr (R(2) = 0.93, P < 0.001) with a difference of 0.0 ±â€Š0.7  m/s. PWVca_cs was also correlated to PWVcs (R(2) = 0.90, P < 0.001) with a difference of 0.1 ±â€Š0.7  m/s. Central systolic pressures were strongly correlated. The difference between car-SBPca and ao-SBPscr was 3.1 ±â€Š4.2  mmHg (P < 0.001), statistically equivalent to the difference between car-SBPscr and ao-SBPscr (3.9 ±â€Š5.8  mmHg, P < 0.001), whilst the difference between car-SBPca and car-SBPscr was negligible (-0.7 ±â€Š5.6  mmHg, P = NS). CONCLUSION: The new Complior Analyse device provides equivalent results for PWV and central pressure values to the Sphygmocor and Complior SP. It reaches Association for the Advancement of Medical Instrumentation standard for central blood pressure and grades as excellent for PWV on the Artery Society criteria. It can be interchanged with existing devices.


Asunto(s)
Determinación de la Presión Sanguínea/instrumentación , Determinación de la Presión Sanguínea/métodos , Anciano , Algoritmos , Presión Sanguínea , Calibración , Enfermedades Cardiovasculares/fisiopatología , Arterias Carótidas/patología , Grosor Intima-Media Carotídeo , Equipo para Diagnóstico , Diseño de Equipo , Femenino , Arteria Femoral/patología , Humanos , Masculino , Persona de Mediana Edad , Análisis de la Onda del Pulso , Sístole
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA