Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
Haemophilia ; 24(3): 492-501, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29488668

RESUMEN

INTRODUCTION: Chromogenic substrate assays (CSA) to measure Factor IX (FIX) have recently become commercially available. However, information on their performance characteristics and use in diagnostic haemostasis laboratories remains limited. AIM: To evaluate the Hyphen Biomed (Hyphen) and Rossix FIX CSAs on fully automated coagulation analysers and compare them to the FIX one-stage assay (OSA). This study was conducted in a tertiary referral haemostasis laboratory associated with a haemophilia treatment centre. METHODS: Automated CSA protocols were adapted to the Sysmex CS2500 (CS2500) and Diagnostica Stago STA-R (STA-R) analysers. Samples assayed were from healthy volunteers, haemophilia B patients and FIX deficient plasma spiked with either plasma derived, recombinant or extended half-life FIX products. RESULTS: Reference intervals for Hyphen and Rossix assays were 73 IU/dL to 164 IU/dL and 73 IU/dL to 168 IU/dL, respectively, on the CS2500 analyser; and 84 IU/dL to 165 IU/dL for the Rossix assay on the STA-R. Repeatability across all method/analyser combinations resulted in CVs ranging from 0.8% to 5.4%. Between run reproducibility gave CVs <6.7% for all method/analyser combinations. In spiked samples, FIX recoveries were mostly within an acceptable limit of 100 ± 25% for BeneFIX® , Rixubis® and Alprolix® with some differences between CSAs. CONCLUSION: Both commercial factor FIX CSA kits can be adapted for Stago and Sysmex automated coagulation analysers. Reagent cost and workflow practices will need to be considered. These assays are potentially more consistent than OSA in measurement of replacement FIX products in haemophilia B patients.


Asunto(s)
Análisis Químico de la Sangre/métodos , Lipoproteínas/sangre , Adolescente , Adulto , Anciano , Automatización , Coagulación Sanguínea/efectos de los fármacos , Factor IX/farmacología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
2.
Phys Rev Lett ; 109(1): 012501, 2012 Jul 06.
Artículo en Inglés | MEDLINE | ID: mdl-23031099

RESUMEN

The rotational band structure of the Z=104 nucleus (256)Rf has been observed up to a tentative spin of 20ℏ using state-of-the-art γ-ray spectroscopic techniques. This represents the first such measurement in a superheavy nucleus whose stability is entirely derived from the shell-correction energy. The observed rotational properties are compared to those of neighboring nuclei and it is shown that the kinematic and dynamic moments of inertia are sensitive to the underlying single-particle shell structure and the specific location of high-j orbitals. The moments of inertia therefore provide a sensitive test of shell structure and pairing in superheavy nuclei which is essential to ensure the validity of contemporary nuclear models in this mass region. The data obtained show that there is no deformed shell gap at Z=104, which is predicted in a number of current self-consistent mean-field models.

3.
Phys Rev Lett ; 84(16): 3542-5, 2000 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-11019141

RESUMEN

The entry distribution in angular momentum and excitation energy for the formation of 254No has been measured after the 208Pb(48Ca,2n) reaction at 215 and 219 MeV. This nucleus is populated up to spin 22Planck's over 2pi and excitation energy greater, similar6 MeV above the yrast line, with the half-maximum points of the energy distributions at approximately 5 MeV for spins between 12Planck's over 2pi and 22Planck's over 2pi. This suggests that the fission barrier is greater, similar5 MeV and that the shell-correction energy persists to high spin.

4.
Int J Lab Hematol ; 35(2): 222-4, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23020832

RESUMEN

INTRODUCTION: Studies have shown dabigatran to be an effective anticoagulant with an acceptable bleeding profile. None the less, these patients do suffer from bleeding complications. Unfortunately, there are currently no direct reversal agents to dabigatran or established guidelines on the management of bleeding in these circumstances. METHODS: We examined the effects on thrombin generation parameters, after ex-vivo spiking the plasma of patients on dabigatran (n = 8) with FEIBA(®). These parameters were measured using the calibrated automated thrombography (CAT) machine. RESULTS: In our study, we showed the ability of FEIBA(®) to improve the abnormal thrombin generation parameters caused by dabigatran in these patients. CONCLUSION: This provides evidence, lacking in the literature, that this agent may be able to provide haemostatic support in situations where dabigatran induced coagulopathy exists.


Asunto(s)
Antitrombinas/farmacología , Bencimidazoles/farmacología , Factores de Coagulación Sanguínea/uso terapéutico , Coagulación Sanguínea/efectos de los fármacos , Pruebas de Química Clínica/normas , beta-Alanina/análogos & derivados , Bencimidazoles/uso terapéutico , Trastornos de la Coagulación Sanguínea/tratamiento farmacológico , Dabigatrán , Humanos , Proyectos de Investigación , beta-Alanina/farmacología , beta-Alanina/uso terapéutico
5.
Int J Lab Hematol ; 35(4): 447-56, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23279758

RESUMEN

INTRODUCTION: The CELL-DYN Emerald is a compact bench-top hematology analyzer that can be used for a three-part white cell differential analysis. To determine its utility for analysis of human and mouse samples, we evaluated this machine against the larger CELL-DYN Sapphire and Sysmex XT2000iV hematology analyzers. METHODS: 120 human (normal and abnormal) and 30 mouse (normal and abnormal) samples were analyzed on both the CELL-DYN Emerald and CELL-DYN Sapphire or Sysmex XT2000iV analyzers. For mouse samples, the CELL-DYN Emerald analyzer required manual recalibration based on the histogram populations. RESULTS: Analysis of the CELL-DYN Emerald showed excellent precision, within accepted ranges (white cell count CV% = 2.09%; hemoglobin CV% = 1.68%; platelets CV% = 4.13%). Linearity was excellent (R² ≥ 0.99), carryover was minimal (<1%), and overall interinstrument agreement was acceptable for both human and mouse samples. Comparison between the CELL-DYN Emerald and Sapphire analyzers for human samples or Sysmex XT2000iV analyzer for mouse samples showed excellent correlation for all parameters. CONCLUSION: The CELL-DYN Emerald was generally comparable to the larger reference analyzer for both human and mouse samples. It would be suitable for use in satellite research laboratories or as a backup system in larger laboratories.


Asunto(s)
Automatización de Laboratorios/normas , Hematología/normas , Laboratorios/normas , Animales , Automatización de Laboratorios/instrumentación , Recuento de Células Sanguíneas , Hematología/instrumentación , Humanos , Ratones , Valores de Referencia , Reproducibilidad de los Resultados
8.
Phys Rev Lett ; 72(23): 3737, 1994 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-10056279
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA