Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
J Acoust Soc Am ; 151(3): 2159, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35364946

RESUMEN

Transcranial focused ultrasound (FUS) is a noninvasive treatment for brain tumors and neuromodulation. Based on normal incidence, conventional FUS techniques use a focused or an array of ultrasonic transducers to overcome the attenuation and absorption of ultrasound in the skull; however, this remains the main limitation of using FUS. A dual-mode conversion technique based on Lamb waves is proposed to achieve high transmission efficiency. This concept was validated using the finite element analysis (FEA) and experiments based on changes in the incident angle. Aluminum, plexiglass, and a human skull were used as materials with different attenuations. The transmission loss was calculated for each material, and the results were compared with the reflectance function of the Lamb waves. Oblique incidence based on dual-mode conversion exhibited a better transmission efficiency than that of a normal incidence for all of the specimens. The total transmission losses for the materials were 13.7, 15.46, and 3.91 dB less than those associated with the normal incidence. A wedge transducer was designed and fabricated to implement the proposed method. The results demonstrated the potential applicability of the dual-mode conversion technique for the human skull.


Asunto(s)
Cráneo , Transductores , Animales , Cabeza , Ovinos , Cráneo/diagnóstico por imagen , Ultrasonido , Ultrasonografía
2.
Ultrasonics ; 132: 107003, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37099939

RESUMEN

Ultrasonic reflectivity using a V(z) technique is a powerful characterization method in acoustic microscopy to measure the elastic properties of materials. Conventional techniques generally use a low f-number with high frequency; however, to measure the reflectance function of the highly attenuative material, a low frequency is essential. In this study, the transducer-pair method based on Lamb waves is used to measure the reflectance function of a highly attenuative material. The results demonstrate the feasibility of the proposed method using a commercial ultrasound transducer with high f-number.

3.
Ultrasound Med Biol ; 48(3): 497-511, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34955292

RESUMEN

Compared with the conventional method of transcranial focused ultrasound stimulation using a single transducer or a focused beam, the compression and tensile forces are generated from the high-pressure gradient of a standing wave that can generate increased stimulation. We experimentally verified a neuromodulation system using patterned interference radiation force (PIRF) and propose a method for obtaining the magnitude of the radiation force, which is considered the main factor influencing ultrasound neuromodulation. The radiation forces generated using a single focused transducer and a standing wave created via two focused transducers were compared using simulations. Radiation force was calculated based on the relationship between the acoustic pressure, radiation force and time-averaged second-order pressure obtained using an acoustic streaming simulation. The presence of the radiation force was verified by measuring the time-averaged second-order pressure generated due to the radiation force, by using a glass tube.


Asunto(s)
Encéfalo , Transductores , Acústica , Encéfalo/diagnóstico por imagen , Simulación por Computador , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA