Biosens Bioelectron ; 8(1): 1-38, 1993.
Artículo en Inglés | MEDLINE | ID: mdl-8499085

RESUMEN

Recent progress in the design of new polymer membrane-based potentiometric ion-, gas- and bio-selective electrodes in chemistry laboratories at the University of Michigan (Ann Arbor) is reviewed. Emphasis is placed on describing the performance of devices for measuring anions (e.g., salicylate, thiocyanate, chloride and heparin) and gases (e.g., ammonia, carbon dioxide and oxygen) in biological samples, both in vitro and in vivo. Beyond direct measurement of key ions and gases in complex matrices, some of the new membrane electrode systems reported can serve as base transducers for the development of biosensors containing integrated biological reagents, including enzymes and antibodies. New approaches for mass fabricating solid-state ion and biosensor devices as well as future directions for research in the entire field of polymer membrane sensors are also described.


Asunto(s)
Aniones/análisis , Técnicas Biosensibles , Gases/análisis , Membranas Artificiales , Polímeros , Electrodos , Humanos , Estructura Molecular , Potenciometría
2.
J Pharm Sci ; 90(8): 1164-75, 2001 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-11536221

RESUMEN

Automated log P, pK(a), solubility, and chemical stability systems comprise an integrated process that provides early stage physicochemical property data to the discovery research organization. Capillary electrophoresis (CE) techniques are used to experimentally determine pK(a) and log P. Solubility is determined using a quasi-equilibrium approach employing sample quantitation by flow injection analysis with ultraviolet (UV) detection at 256 nm. Chemical stability is assessed by challenging compounds with pH 2, pH 7, pH 12, and 3% hydrogen peroxide solutions overnight, and comparing the chromatographic profiles of the stability challenged solutions to that of a freshly prepared control. Validation of the log P method using a set of drug-like compounds demonstrates that the method yields log P values within +/-0.5 units of literature values. The log P method is valid over the range -0.5-5.0, and the technique is compatible with acidic, neutral, and basic compounds. The pK(a) technique yields results within +/-0.2 units of corresponding values obtained by potentiometric titration over a pK(a) range of 2 to 12. Solubility is reported in a 3-60 microg/mL range, and the results are generally within 20% of values measured by equilibrium solubility techniques. The current level of automation supports the measurement of the physicochemical properties of 100 compounds per week. Physicochemical property data for approximately 2000 compounds have been generated to date.


Asunto(s)
Preparaciones Farmacéuticas/química , Automatización , Electroforesis Capilar , Análisis de Inyección de Flujo , Solubilidad , Espectrofotometría Ultravioleta
3.
Mol Divers ; 1(4): 247-58, 1996 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-9237216

RESUMEN

The advantages of evaporative light-scattering detection over UV detection for the quantitation of combinatorial libraries composed of small organic compounds by HPLC are described. The detector's response is independent of the sample chromophore, which makes it well-suited to chromatographic analyses of mixtures of dissimilar solutes. Thus, HPLC with evaporative light-scattering detection offers to potential for reducing false positive or false negative results in screening assays, because of its ability to detect the presence of impurities that absorb poorly in the UV (e.g., those impurities originating from the polymeric support). Furthermore, the evaporative light-scattering detector exhibits a nearly equivalent response to compounds of similar structural class. Hence, rapid quantitation of compound libraries may be carried out with the use of a single external standard. For example, the quantitation errors, based on a single external standard, for a series of steroids, hydantoins, and BOC- and Fmoc-protected amino acids by normal-phase HPLC with evaporative light-scattering detection average approximately +/-10%. The application of the evaporative light-scattering detector to the quantitation of low-level sample impurities and the detector's compatibility with gradient elution are also described.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Evolución Molecular Dirigida/métodos , Aminoácidos/química , Química Orgánica/métodos , Cromatografía Líquida de Alta Presión/normas , Hidantoínas/química , Luz , Estándares de Referencia , Dispersión de Radiación , Espectrofotometría Ultravioleta , Esteroides/química , Esteroides/normas
4.
Anal Chem ; 65(17): 2189-96, 1993 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-8238924

RESUMEN

A tetraphenylporphyrin-based stationary phase for high-performance liquid chromatography is prepared by attaching a p-carboxyphenyl derivative of the porphyrin to aminopropyl silica gel through an amide bond. This stationary-phase support is used for the reversed-phase separation of several polycyclic aromatic hydrocarbons and is shown to exhibit novel shape selectivity toward planar aromatic solutes. Subsequent metalation of the immobilized tetraphenylporphyrin with either tin(IV) or indium(III) results in a stationary phase with anion-exchange characteristics. Both the tin(IV) and indium(III) metalloporphyrin-based stationary phases exhibit useful selectivity for the separation of aromatic sulfonates and aromatic carboxylates.


Asunto(s)
Porfirinas/aislamiento & purificación , Cromatografía por Intercambio Iónico , Indicadores y Reactivos , Porfirinas/química , Gel de Sílice , Dióxido de Silicio
5.
J Chromatogr ; 641(1): 49-55, 1993 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-8349741

RESUMEN

The reversed-phase chromatographic behavior of planar and non-planar polycyclic aromatic hydrocarbons (PAHs) is investigated on tetraphenylporphyrin and two metallotetraphenylporphyrin [Sn(IV), In(III)] bonded stationary phases using methanol-water and acetonitrile-water as mixed solvent mobile phases. Large differences in the capacity factors of aromatic solute pairs having the same number of carbon atoms, but differing in three-dimensional shape (e.g., triphenylene/o-terphenyl and perylene/alpha, alpha'-binaphthyl), suggest that the three tetraphenylporphyrin-based supports possess shape selectivity toward small planar aromatic solutes. Capacity factors for planar PAH solutes on these supports are significantly greater than for non-planar polyaryls having the same number of carbon atoms.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Metaloporfirinas/química , Compuestos Policíclicos/aislamiento & purificación , Espectrofotometría Ultravioleta
SELECCIÓN DE REFERENCIAS