1.
J Cardiovasc Magn Reson ; 21(1): 30, 2019 05 20.
Artículo en Inglés | MEDLINE | ID: mdl-31104632

RESUMEN

BACKGROUND: A velocity offset error in phase contrast cardiovascular magnetic resonance (CMR) imaging is a known problem in clinical assessment of flow volumes in vessels around the heart. Earlier studies have shown that this offset error is clinically relevant over different systems, and cannot be removed by protocol optimization. Correction methods using phantom measurements are time consuming, and assume reproducibility of the offsets which is not the case for all systems. An alternative previously published solution is to correct the in-vivo data in post-processing, interpolating the velocity offset from stationary tissue within the field-of-view. This study aims to validate this interpolation-based offset correction in-vivo in a multi-vendor, multi-center setup. METHODS: Data from six 1.5 T CMR systems were evaluated, with two systems from each of the three main vendors. At each system aortic and main pulmonary artery 2D flow studies were acquired during routine clinical or research examinations, with an additional phantom measurement using identical acquisition parameters. To verify the phantom acquisition, a region-of-interest (ROI) at stationary tissue in the thorax wall was placed and compared between in-vivo and phantom measurements. Interpolation-based offset correction was performed on the in-vivo data, after manually excluding regions of spatial wraparound. Correction performance of different spatial orders of interpolation planes was evaluated. RESULTS: A total of 126 flow measurements in 82 subjects were included. At the thorax wall the agreement between in-vivo and phantom was - 0.2 ± 0.6 cm/s. Twenty-eight studies were excluded because of a difference at the thorax wall exceeding 0.6 cm/s from the phantom scan, leaving 98. Before correction, the offset at the vessel as assessed in the phantom was - 0.4 ± 1.5 cm/s, which resulted in a - 5 ± 16% error in cardiac output. The optimal order of the interpolation correction plane was 1st order, except for one system at which a 2nd order plane was required. Application of the interpolation-based correction revealed a remaining offset velocity of 0.1 ± 0.5 cm/s and 0 ± 5% error in cardiac output. CONCLUSIONS: This study shows that interpolation-based offset correction reduces the offset with comparable efficacy as phantom measurement phase offset correction, without the time penalty imposed by phantom scans. TRIAL REGISTRATION: The study was registered in The Netherlands National Trial Register (NTR) under TC 4865 . Registered 19 September 2014. Retrospectively registered.


Asunto(s)
Aorta/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Imagen de Perfusión/métodos , Arteria Pulmonar/diagnóstico por imagen , Adulto , Aorta/fisiopatología , Velocidad del Flujo Sanguíneo , Europa (Continente) , Femenino , Humanos , Imagen por Resonancia Magnética/instrumentación , Masculino , Persona de Mediana Edad , Imagen de Perfusión/instrumentación , Fantasmas de Imagen , Valor Predictivo de las Pruebas , Arteria Pulmonar/fisiopatología , Flujo Sanguíneo Regional , Reproducibilidad de los Resultados , Adulto Joven
2.
Circulation ; 136(18): 1703-1713, 2017 Oct 31.
Artículo en Inglés | MEDLINE | ID: mdl-29084778

RESUMEN

BACKGROUND: Pulmonary valve replacement (PVR) in patients with repaired tetralogy of Fallot provides symptomatic benefit and right ventricular (RV) volume reduction. However, data on the rate of ventricular structural and functional adaptation are scarce. We aimed to assess immediate and midterm post-PVR changes and predictors of reverse remoeling. METHODS: Fifty-seven patients with repaired tetralogy of Fallot (age ≥16 y; mean age, 35.8±10.1 y; 38 male) undergoing PVR were prospectively recruited for cardiovascular magnetic resonance performed before PVR (pPVR), immediately after PVR (median, 6 d), and midterm after PVR (mPVR; median, 3 y). RESULTS: There were immediate and midterm reductions in indexed RV end-diastolic volumes and RV end-systolic volumes (RVESVi) (indexed RV end-diastolic volume pPVR versus immediately after PVR versus mPVR, 156.1±41.9 versus 104.9±28.4 versus 104.2±34.4 mL/m2; RVESVi pPVR versus immediately after PVR versus mPVR, 74.9±26.2 versus 57.4±22.7 versus 50.5±21.7 mL/m2; P<0.01). Normal postoperative diastolic and systolic RV volumes (the primary end point) achieved in 70% of patients were predicted by a preoperative indexed RV end-diastolic volume ≤158 mL/m2 and RVESVi ≤82 mL/m2. RVESVi showed a progressive decrease from baseline to immediate to midterm follow-up, indicating ongoing intrinsic RV functional improvement after PVR. Left ventricular ejection fraction improved (pPVR versus mPVR, 59.4±7.6% versus 61.9±6.8%; P<0.01), and right atrial reverse remodeling occurred (pPVR versus mPVR, 15.2±3.4 versus 13.8±3.6 cm2/m2; P<0.01). Larger preoperative RV outflow tract scar was associated with a smaller improvement in post-PVR RV/left ventricular ejection fraction. RV ejection fraction and peak oxygen uptake predicted mortality (P=0.03) over a median of 9.5 years of follow-up. CONCLUSIONS: Significant right heart structural reverse remodeling takes place immediately after PVR, followed by a continuing process of further biological remodeling manifested by further reduction in RVESVi. PVR before RVESVi reaches 82 mL/m2 confers optimal chances of normalization of RV function.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Imagen por Resonancia Magnética , Válvula Pulmonar/cirugía , Volumen Sistólico , Tetralogía de Fallot , Remodelación Ventricular , Adulto , Femenino , Estudios de Seguimiento , Humanos , Masculino , Tetralogía de Fallot/diagnóstico por imagen , Tetralogía de Fallot/fisiopatología , Tetralogía de Fallot/cirugía
3.
Magn Reson Med ; 79(4): 2205-2215, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-28734017

RESUMEN

PURPOSE: To evaluate the importance of strain-correcting stimulated echo acquisition mode echo-planar imaging cardiac diffusion tensor imaging. METHODS: Healthy pigs (n = 11) were successfully scanned with a 3D cine displacement-encoded imaging with stimulated echoes and a monopolar-stimulated echo-planar imaging diffusion tensor imaging sequence at 3 T during diastasis, peak systole, and strain sweet spots in a midventricular short-axis slice. The same diffusion tensor imaging sequence was repeated ex vivo after arresting the hearts in either a relaxed (KCl-induced) or contracted (BaCl2 -induced) state. The displacement-encoded imaging with stimulated echoes data were used to strain-correct the in vivo cardiac diffusion tensor imaging in diastole and systole. The orientation of the primary (helix angles) and secondary (E2A) diffusion eigenvectors was compared with and without strain correction and to the strain-free ex vivo data. RESULTS: Strain correction reduces systolic E2A significantly when compared without strain correction and ex vivo (median absolute E2A = 34.3° versus E2A = 57.1° (P = 0.01), E2A = 60.5° (P = 0.006), respectively). The systolic distribution of E2A without strain correction is closer to the contracted ex vivo distribution than with strain correction, root mean square deviation of 0.027 versus 0.038. CONCLUSIONS: The current strain-correction model amplifies the contribution of microscopic strain to diffusion resulting in an overcorrection of E2A. Results show that a new model that considers cellular rearrangement is required. Magn Reson Med 79:2205-2215, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Imagen de Difusión Tensora , Corazón/diagnóstico por imagen , Algoritmos , Animales , Simulación por Computador , Diástole , Imagen de Difusión por Resonancia Magnética , Imagen Eco-Planar , Interpretación de Imagen Asistida por Computador , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Imagen por Resonancia Cinemagnética , Respiración , Respiración Artificial , Programas Informáticos , Estrés Mecánico , Porcinos , Sístole
4.
J Cardiovasc Magn Reson ; 20(1): 1, 2018 01 03.
Artículo en Inglés | MEDLINE | ID: mdl-29298692

RESUMEN

BACKGROUND: Stimulated-echo (STEAM) and, more recently, motion-compensated spin-echo (M2-SE) techniques have been used for in-vivo diffusion tensor cardiovascular magnetic resonance (DT-CMR) assessment of cardiac microstructure. The two techniques differ in the length scales of diffusion interrogated, their signal-to-noise ratio efficiency and sensitivity to both motion and strain. Previous comparisons of the techniques have used high performance gradients at 1.5 T in a single cardiac phase. However, recent work using STEAM has demonstrated novel findings of microscopic dysfunction in cardiomyopathy patients, when DT-CMR was performed at multiple cardiac phases. We compare STEAM and M2-SE using a clinical 3 T scanner in three potentially clinically interesting cardiac phases. METHODS: Breath hold mid-ventricular short-axis DT-CMR was performed in 15 subjects using M2-SE and STEAM at end-systole, systolic sweet-spot and diastasis. Success was defined by ≥50% of the myocardium demonstrating normal helix angles. From successful acquisitions DT-CMR results relating to tensor orientation, size and shape were compared between sequences and cardiac phases using non-parametric statistics. Strain information was obtained using cine spiral displacement encoding with stimulated echoes for comparison with DT-CMR results. RESULTS: Acquisitions were successful in 98% of STEAM and 76% of M2-SE cases and visual helix angle (HA) map scores were higher for STEAM at the sweet-spot and diastasis. There were significant differences between sequences (p < 0.05) in mean diffusivity (MD), fractional anisotropy (FA), tensor mode, transmural HA gradient and absolute second eigenvector angle (E2A). Differences in E2A between systole and diastole correlated with peak radial strain for both sequences (p ≤ 0.01). CONCLUSION: M2-SE and STEAM can be performed equally well at peak systole at 3 T using standard gradients, but at the sweet-spot and diastole STEAM is more reliable and image quality scores are higher. Differences in DT-CMR results are potentially due to differences in motion sensitivity and the longer diffusion time of STEAM, although the latter appears to be the dominant factor. The benefits of both sequences should be considered when planning future studies and sequence and cardiac phase specific normal ranges should be used for comparison.


Asunto(s)
Imagen de Difusión Tensora , Corazón/diagnóstico por imagen , Imagen por Resonancia Cinemagnética , Función Ventricular Izquierda , Adulto , Contencion de la Respiración , Femenino , Voluntarios Sanos , Corazón/fisiología , Humanos , Masculino , Valor Predictivo de las Pruebas , Adulto Joven
5.
J Magn Reson Imaging ; 43(6): 1313-9, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-26584006

RESUMEN

PURPOSE: To determine whether neglecting the flow unsteadiness in simplified Bernoulli's equation significantly affects the pulmonary transvalvular pressure drop estimation. MATERIALS AND METHODS: 3.0T magnetic resonance imaging (MRI) 4D velocity mapping was performed on four healthy volunteers, seven patients with repaired tetralogy of Fallot, and thirteen patients with transposition of the great arteries repaired by arterial switch. Pulmonary transvalvular pressure drop was estimated based on two methods: General Bernoulli's Equation (GBE), ie, the most complete form; and Simplified Bernoulli's Equation (SBE), known as 4V(2) . More than 2300 individual pressure drop measurements were used to compare the simplified and the general Bernoulli's methods. A linear mixed-effects model was employed for statistical analyses, fully accounting for clustering of observations among the methods and systolic phases. RESULTS: The simplified Bernoulli's method systematically underestimated the pressure drop compared to general Bernoulli's method during the entire systolic phase (P < 0.05), including the peak systole, where on average ΔpSBE/ΔpGBE=78%. CONCLUSION: The simplified Bernoulli method underestimated the pressure drop during all systolic phases in all the studied subjects. Therefore, it is necessary to take into account the flow unsteadiness for more accurate estimation of the pressure drop. J. Magn. Reson. Imaging 2016;43:1313-1319.


Asunto(s)
Determinación de la Presión Sanguínea/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Modelos Cardiovasculares , Estenosis de la Válvula Pulmonar/diagnóstico por imagen , Estenosis de la Válvula Pulmonar/fisiopatología , Válvula Pulmonar/fisiopatología , Adolescente , Adulto , Velocidad del Flujo Sanguíneo , Presión Sanguínea , Niño , Simulación por Computador , Femenino , Humanos , Lactante , Masculino , Persona de Mediana Edad , Circulación Pulmonar , Válvula Pulmonar/diagnóstico por imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
6.
J Cardiovasc Magn Reson ; 18(1): 51, 2016 08 26.
Artículo en Inglés | MEDLINE | ID: mdl-27561421

RESUMEN

Tissue tracking technology of routinely acquired cardiovascular magnetic resonance (CMR) cine acquisitions has increased the apparent ease and availability of non-invasive assessments of myocardial deformation in clinical research and practice. Its widespread availability thanks to the fact that this technology can in principle be applied on images that are part of every CMR or echocardiographic protocol. However, the two modalities are based on very different methods of image acquisition and reconstruction, each with their respective strengths and limitations. The image tracking methods applied are not necessarily directly comparable between the modalities, or with those based on dedicated CMR acquisitions for strain measurement such as tagging or displacement encoding. Here we describe the principles underlying the image tracking methods for CMR and echocardiography, and the translation of the resulting tracking estimates into parameters suited to describe myocardial mechanics. Technical limitations are presented with the objective of suggesting potential solutions that may allow informed and appropriate use in clinical applications.


Asunto(s)
Ecocardiografía/métodos , Cardiopatías/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Contracción Miocárdica , Función Ventricular , Fenómenos Biomecánicos , Cardiopatías/fisiopatología , Humanos , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados
7.
J Cardiovasc Magn Reson ; 18: 12, 2016 Mar 03.
Artículo en Inglés | MEDLINE | ID: mdl-26940894

RESUMEN

BACKGROUND: We measured by cine cardiovascular magnetic resonance (CMR) main and branch pulmonary artery diameters and cross sectional areas in diastole and systole in order to establish normal ranges and the effects on them of age, gender and body surface area (BSA). Documentation of normal ranges provides a reference for research and clinical investigation in the fields of congenital heart disease, pulmonary hypertension and connective tissue disorders. METHODS: We recruited 120 healthy volunteers: ten males (M) and ten females (F) in each decile between 20 and 79 years, imaging them in a 1.5 Tesla CMR system. Scout acquisitions guided the placement of steady state free precession cine acquisitions transecting the main, right and left pulmonary arteries (MPA, RPA and LPA). Cross sections were rarely quite circular. RESULTS: From all subjects, the means of the greater and lesser orthogonal diastolic diameters in mm were: MPA, 22.9 ± 2.4 (M) and 21.2 ± 2.1 (F), RPA 16.6 ± 2.8 (M) and 14.7 ± 2.2 (F), and LPA 17.3 ± 2.5 (M) and 15.9 ± 2.0 (F), p < 0.0001 between genders in each case. The diastolic diameters increased with BSA and age, and plots are provided for reference. From measurements of minimum diastolic and maximum systolic cross sectional areas, the % systolic distensions were: MPA 42.7 ± 17.2 (M) and 41.8 ± 15.7 (F), RPA 50.6 ± 16.9 (M) and 48.2 ± 14.5 (F), LPA 35.6 ± 10.1 (M) and 35.2 ± 10.3 (F), and there was a decrease in distension with age (p < 0.0001 for the MPA). CONCLUSIONS: Measurements of MPA, RPA and LPA by cine CMR are provided for reference, with documentation of their changes with age and BSA.


Asunto(s)
Angiografía por Resonancia Magnética , Imagen por Resonancia Cinemagnética , Arteria Pulmonar/anatomía & histología , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Superficie Corporal , Femenino , Voluntarios Sanos , Humanos , Modelos Lineales , Angiografía por Resonancia Magnética/normas , Imagen por Resonancia Cinemagnética/normas , Masculino , Persona de Mediana Edad , Análisis Multivariante , Valor Predictivo de las Pruebas , Valores de Referencia , Factores Sexuales , Adulto Joven
8.
Magn Reson Med ; 74(2): 420-30, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25154715

RESUMEN

PURPOSE: To investigate the influence of the diffusion weighting on in vivo cardiac diffusion tensor imaging (cDTI) and obtain optimal parameters. METHODS: Ten subjects were scanned using stimulated echo acquisition mode echo planar imaging with six b-values, from 50 to 950 s·mm(-2) , plus b = 15 s·mm(-2) reference. The relationship between b-value and both signal loss and signal-to-noise ratio measures was investigated. Mean diffusivity, fractional anisotropy, and helical angle maps were calculated using all possible b-value pairs to investigate the effects of diffusion weighting on the main and reference data. RESULTS: Signal decay at low b-values was dominated by processes with high apparent diffusion coefficients, most likely microvascular perfusion. This effect could be avoided by diffusion weighting of the reference images. Parameter maps were improved with increased b-value until the diffusion-weighted signal approached the noise floor. For the protocol used in this study, b = 750 s·mm(-2) combined with 150 s·mm(-2) diffusion weighting of the reference images proved optimal. CONCLUSION: Mean diffusivity, fractional anisotropy, and helical angle from cDTI are influenced by the b-value of the main and reference data. Using optimal values improves parameter maps and avoids microvascular perfusion effects. This optimized protocol should provide greater sensitivity to pathological changes in parameter maps.


Asunto(s)
Algoritmos , Imagen Eco-Planar/métodos , Ventrículos Cardíacos/anatomía & histología , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Adulto , Imagen de Difusión por Resonancia Magnética/métodos , Imagen de Difusión Tensora , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador , Relación Señal-Ruido , Adulto Joven
9.
J Cardiovasc Magn Reson ; 17: 72, 2015 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-26257141

RESUMEN

Pulsatile blood flow through the cavities of the heart and great vessels is time-varying and multidirectional. Access to all regions, phases and directions of cardiovascular flows has formerly been limited. Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) has enabled more comprehensive access to such flows, with typical spatial resolution of 1.5×1.5×1.5 - 3×3×3 mm(3), typical temporal resolution of 30-40 ms, and acquisition times in the order of 5 to 25 min. This consensus paper is the work of physicists, physicians and biomedical engineers, active in the development and implementation of 4D Flow CMR, who have repeatedly met to share experience and ideas. The paper aims to assist understanding of acquisition and analysis methods, and their potential clinical applications with a focus on the heart and greater vessels. We describe that 4D Flow CMR can be clinically advantageous because placement of a single acquisition volume is straightforward and enables flow through any plane across it to be calculated retrospectively and with good accuracy. We also specify research and development goals that have yet to be satisfactorily achieved. Derived flow parameters, generally needing further development or validation for clinical use, include measurements of wall shear stress, pressure difference, turbulent kinetic energy, and intracardiac flow components. The dependence of measurement accuracy on acquisition parameters is considered, as are the uses of different visualization strategies for appropriate representation of time-varying multidirectional flow fields. Finally, we offer suggestions for more consistent, user-friendly implementation of 4D Flow CMR acquisition and data handling with a view to multicenter studies and more widespread adoption of the approach in routine clinical investigations.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico , Sistema Cardiovascular/fisiopatología , Interpretación de Imagen Asistida por Computador/normas , Angiografía por Resonancia Magnética/normas , Imagen de Perfusión Miocárdica/normas , Aorta/fisiopatología , Velocidad del Flujo Sanguíneo , Enfermedades Cardiovasculares/patología , Enfermedades Cardiovasculares/fisiopatología , Sistema Cardiovascular/patología , Consenso , Circulación Coronaria , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Imagen de Perfusión Miocárdica/métodos , Valor Predictivo de las Pruebas , Flujo Pulsátil , Factores de Tiempo
10.
J Cardiovasc Magn Reson ; 16: 100, 2014 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-25475898

RESUMEN

There were 109 articles published in the Journal of Cardiovascular Magnetic Resonance (JCMR) in 2013, which is a 21% increase on the 90 articles published in 2012. The quality of the submissions continues to increase. The editors are delighted to report that the 2012 JCMR Impact Factor (which is published in June 2013) has risen to 5.11, up from 4.44 for 2011 (as published in June 2012), a 15% increase and taking us through the 5 threshold for the first time. The 2012 impact factor means that the JCMR papers that were published in 2010 and 2011 were cited on average 5.11 times in 2012. The impact factor undergoes natural variation according to citation rates of papers in the 2 years following publication, and is significantly influenced by highly cited papers such as official reports. However, the progress of the journal's impact over the last 5 years has been impressive. Our acceptance rate is <25% and has been falling because the number of articles being submitted has been increasing. In accordance with Open-Access publishing, the JCMR articles go on-line as they are accepted with no collating of the articles into sections or special thematic issues. For this reason, the Editors have felt that it is useful once per calendar year to summarize the papers for the readership into broad areas of interest or theme, so that areas of interest can be reviewed in a single article in relation to each other and other recent JCMR articles. The papers are presented in broad themes and set in context with related literature and previously published JCMR papers to guide continuity of thought in the journal. We hope that you find the open-access system increases wider reading and citation of your papers, and that you will continue to send your quality manuscripts to JCMR for publication.


Asunto(s)
Investigación Biomédica , Cardiología , Enfermedades Cardiovasculares/diagnóstico , Imagen por Resonancia Magnética , Publicaciones Periódicas como Asunto , Animales , Bibliometría , Investigación Biomédica/estadística & datos numéricos , Cardiología/estadística & datos numéricos , Enfermedades Cardiovasculares/patología , Enfermedades Cardiovasculares/fisiopatología , Políticas Editoriales , Humanos , Factor de Impacto de la Revista , Imagen por Resonancia Magnética/estadística & datos numéricos , Publicaciones Periódicas como Asunto/estadística & datos numéricos , Valor Predictivo de las Pruebas , Pronóstico
11.
J Cardiovasc Magn Reson ; 16: 87, 2014 Nov 12.
Artículo en Inglés | MEDLINE | ID: mdl-25388867

RESUMEN

BACKGROUND: Cardiac diffusion tensor imaging (cDTI) measures the magnitudes and directions of intramyocardial water diffusion. Assuming the cross-myocyte components to be constrained by the laminar microstructures of myocardium, we hypothesized that cDTI at two cardiac phases might identify any abnormalities of laminar orientation and mobility in hypertrophic cardiomyopathy (HCM). METHODS: We performed cDTI in vivo at 3 Tesla at end-systole and late diastole in 11 healthy controls and 11 patients with HCM, as well as late gadolinium enhancement (LGE) for detection of regional fibrosis. RESULTS: Voxel-wise analysis of diffusion tensors relative to left ventricular coordinates showed expected transmural changes of myocardial helix-angle, with no significant differences between phases or between HCM and control groups. In controls, the angle of the second eigenvector of diffusion (E2A) relative to the local wall tangent plane was larger in systole than diastole, in accord with previously reported changes of laminar orientation. HCM hearts showed higher than normal global E2A in systole (63.9° vs 56.4° controls, p=0.026) and markedly raised E2A in diastole (46.8° vs 24.0° controls, p<0.001). In hypertrophic regions, E2A retained a high, systole-like angulation even in diastole, independent of LGE, while regions of normal wall thickness did not (LGE present 57.8°, p=0.0028, LGE absent 54.8°, p=0.0022 vs normal thickness 38.1°). CONCLUSIONS: In healthy controls, the angles of cross-myocyte components of diffusion were consistent with previously reported transmural orientations of laminar microstructures and their changes with contraction. In HCM, especially in hypertrophic regions, they were consistent with hypercontraction in systole and failure of relaxation in diastole. Further investigation of this finding is required as previously postulated effects of strain might be a confounding factor.


Asunto(s)
Cardiomiopatía Hipertrófica/diagnóstico , Imagen de Difusión por Resonancia Magnética , Imagen de Difusión Tensora , Imagen por Resonancia Cinemagnética , Contracción Miocárdica , Miocardio/patología , Función Ventricular Izquierda , Anciano , Cardiomiopatía Hipertrófica/patología , Cardiomiopatía Hipertrófica/fisiopatología , Estudios de Casos y Controles , Femenino , Fibrosis , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas
12.
Circulation ; 126(21): 2502-10, 2012 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-23136163

RESUMEN

BACKGROUND: The role of mitral valve repair (MVR) during coronary artery bypass grafting (CABG) in patients with moderate ischemic mitral regurgitation (MR) is uncertain. We conducted a randomized, controlled trial to determine whether repairing the mitral valve during CABG may improve functional capacity and left ventricular reverse remodeling compared with CABG alone. METHODS AND RESULTS: Seventy-three patients referred for CABG with moderate ischemic MR and an ejection fraction >30% were randomized to receive CABG plus MVR (34 patients) or CABG only (39 patients). The study was stopped early after review of interim data. At 1 year, there was a greater improvement in the primary end point of peak oxygen consumption in the CABG plus MVR group compared with the CABG group (3.3 mL/kg/min versus 0.8 mL/kg/min; P<0.001). There was also a greater improvement in the secondary end points in the CABG plus MVR group compared with the CABG group: left ventricular end-systolic volume index, MR volume, and plasma B-type natriuretic peptide reduction of 22.2 mL/m(2), 28.2 mL/beat, and 557.4 pg/mL, respectively versus 4.4 mL/m(2) (P=0.002), 9.2 mL/beat (P=0.001), and 394.7 pg/mL (P=0.003), respectively. Operation duration, blood transfusion, intubation duration, and hospital stay duration were greater in the CABG plus MVR group. Deaths at 30 days and 1 year were similar in both groups: 3% and 9%, respectively in the CABG plus MVR group, versus 3% (P=1.00) and 5% (P=0.66), respectively in the CABG group. CONCLUSIONS: Adding mitral annuloplasty to CABG in patients with moderate ischemic MR may improve functional capacity, left ventricular reverse remodeling, MR severity, and B-type natriuretic peptide levels, compared with CABG alone. The impact of these benefits on longer term clinical outcomes remains to be defined.


Asunto(s)
Puente de Arteria Coronaria , Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Mitral/epidemiología , Insuficiencia de la Válvula Mitral/cirugía , Isquemia Miocárdica/epidemiología , Isquemia Miocárdica/cirugía , Anciano , Anciano de 80 o más Años , Puente de Arteria Coronaria/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Anuloplastia de la Válvula Mitral/métodos , Insuficiencia de la Válvula Mitral/fisiopatología , Isquemia Miocárdica/fisiopatología , Método Simple Ciego , Resultado del Tratamiento
13.
J Cardiovasc Magn Reson ; 15: 76, 2013 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-24006874

RESUMEN

There were 90 articles published in the Journal of Cardiovascular Magnetic Resonance (JCMR) in 2012, which is an 8% increase in the number of articles since 2011. The quality of the submissions continues to increase. The editors are delighted to report that the 2011 JCMR Impact Factor (which is published in June 2012) has risen to 4.44, up from 3.72 for 2010 (as published in June 2011), a 20% increase. The 2011 impact factor means that the JCMR papers that were published in 2009 and 2010 were cited on average 4.44 times in 2011. The impact factor undergoes natural variation according to citation rates of papers in the 2 years following publication, and is significantly influenced by highly cited papers such as official reports. However, the progress of the journal's impact over the last 5 years has been impressive. Our acceptance rate is approximately 25%, and has been falling as the number of articles being submitted has been increasing. In accordance with Open-Access publishing, the JCMR articles go on-line as they are accepted with no collating of the articles into sections or special thematic issues. For this reason, the Editors have felt that it is useful once per calendar year to summarize the papers for the readership into broad areas of interest or theme, so that areas of interest can be reviewed in a single article in relation to each other and other recent JCMR articles. The papers are presented in broad themes and set in context with related literature and previously published JCMR papers to guide continuity of thought in the journal. We hope that you find the open-access system increases wider reading and citation of your papers, and that you will continue to send your quality manuscripts to JCMR for publication.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico , Imagen por Resonancia Magnética , Publicaciones Periódicas como Asunto , Animales , Bibliometría , Enfermedades Cardiovasculares/fisiopatología , Enfermedades Cardiovasculares/terapia , Políticas Editoriales , Humanos , Factor de Impacto de la Revista , Valor Predictivo de las Pruebas , Pronóstico
14.
Pediatr Cardiol ; 34(1): 95-104, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22669402

RESUMEN

Although early survival after tetralogy of Fallot (TOF) repair in the modern era is excellent, studies on late outcomes have shown increasing rates of mortality and morbidity. Despite multiple publications on factors associated with late complications, risk factors for major outcomes (death and sustained ventricular tachycardia [VT]) remain poorly defined. Consequently, the International Multicenter TOF Registry (INDICATOR) was established. This article describes the development, structure, and goals of this registry and characterizes the initial cohort derived from four large congenital heart centers in the United States, Canada, and Europe. A data coordinating center with a core cardiac magnetic resonance (CMR) laboratory and statistical core was established. Subjects with repaired TOF who had CMR imaging performed between 1997 and 2010 and ≥ 1 year follow-up were included. Clinical end points were death and sustained VT. Demographic, electrophysiologic, exercise, and outcome data were collected. A total of 873 subjects fulfilled inclusion criteria (median age at repair 2.9 years and at CMR imaging 22.8 years). Of these, 9 % had QRS duration >180 ms on electrocardiogram (ECG). On CMR imaging, 38 % had severe right-ventricular (RV) dilatation (≥ 160 mL/m(2)), and 6 % had severe RV dysfunction (ejection fraction < 35 %). Of the 551 subjects with exercise testing available, 28 % had severely decreased exercise capacity with <50 % predicted peak oxygen consumption. The INDICATOR cohort allows robust statistical analysis to evaluate major clinical outcomes in patients with repaired TOF. Continued follow-up and further expansion of the registry may provide new insights into innovative therapeutic strategies to improve late outcomes.


Asunto(s)
Sistema de Registros/estadística & datos numéricos , Tetralogía de Fallot/complicaciones , Adolescente , Adulto , Canadá , Niño , Preescolar , Estudios de Cohortes , Electrocardiografía , Europa (Continente) , Prueba de Esfuerzo , Femenino , Humanos , Lactante , Recién Nacido , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Pronóstico , Proyectos de Investigación , Factores de Riesgo , Tetralogía de Fallot/mortalidad , Tetralogía de Fallot/cirugía , Resultado del Tratamiento , Estados Unidos , Adulto Joven
15.
J Cardiovasc Magn Reson ; 14: 78, 2012 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-23158097

RESUMEN

There were 83 articles published in the Journal of Cardiovascular Magnetic Resonance (JCMR) in 2011, which is an 11% increase in the number of articles since 2010. The quality of the submissions continues to increase. The editors had been delighted with the 2010 JCMR Impact Factor of 4.33, although this fell modestly to 3.72 for 2011. The impact factor undergoes natural variation according to citation rates of papers in the 2 years following publication, and is significantly influenced by highly cited papers such as official reports. However, we remain very pleased with the progress of the journal's impact over the last 5 years. Our acceptance rate is approximately 25%, and has been falling as the number of articles being submitted has been increasing. In accordance with Open-Access publishing, the JCMR articles go on-line as they are accepted with no collating of the articles into sections or special thematic issues. For this reason, the Editors feel it is useful to summarize the papers for the readership into broad areas of interest or theme, which we feel would be useful, so that areas of interest from the previous year can be reviewed in a single article in relation to each other and other recent JCMR articles. The papers are presented in broad themes and set in context with related literature and previously published JCMR papers to guide continuity of thought in the journal. We hope that you find the open-access system increases wider reading and citation of your papers, and that you will continue to send your quality manuscripts to JCMR for publication.


Asunto(s)
Investigación Biomédica , Enfermedades Cardiovasculares/diagnóstico , Imagen por Resonancia Magnética , Publicaciones Periódicas como Asunto , Animales , Bibliometría , Investigación Biomédica/estadística & datos numéricos , Políticas Editoriales , Humanos , Difusión de la Información , Factor de Impacto de la Revista , Imagen por Resonancia Magnética/estadística & datos numéricos , Publicaciones Periódicas como Asunto/estadística & datos numéricos , Valor Predictivo de las Pruebas , Pronóstico
16.
J Cardiovasc Magn Reson ; 14: 72, 2012 Oct 20.
Artículo en Inglés | MEDLINE | ID: mdl-23083397

RESUMEN

BACKGROUND: Phase-contrast velocity images often contain a background or baseline offset error, which adds an unknown offset to the measured velocities. For accurate flow measurements, this offset must be shown negligible or corrected. Some correction techniques depend on replicating the clinical flow acquisition using a uniform stationary phantom, in order to measure the baseline offset at the region of interest and subtract it from the clinical study. Such techniques assume that the background offset is stable over the time of a patient scan, or even longer if the phantom scans are acquired later, or derived from pre-stored background correction images. There is no published evidence regarding temporal stability of the background offset. METHODS: This study assessed the temporal stability of the background offset on 3 different manufacturers' scanners over 8 weeks, using a retrospectively-gated phase-contrast cine acquisition with fixed parameters and at a fixed location, repeated 5 times in rapid succession each week. A significant offset was defined as 0.6 cm/s within 50 mm of isocenter, based upon an accuracy of 10% in a typical cardiac shunt measurement. RESULTS: Over the 5 repeated cine acquisitions, temporal drift in the baseline offset was insignificant on two machines (0.3 cm/s, 0.2 cm/s), and marginally insignificant on the third machine (0.5 cm/s) due to an apparent heating effect. Over a longer timescale of 8 weeks, insignificant drift (0.4 cm/s) occurred on one, with larger drifts (0.9 cm/s, 0.6 cm/s) on the other machines. CONCLUSIONS: During a typical patient study, background drift was insignificant. Extended high gradient power scanning with work requires care to avoid drift on some machines. Over the longer term of 8 weeks, significant drift is likely, preventing accurate correction by delayed phantom corrections or derivation from pre-stored background offset data.


Asunto(s)
Imagen por Resonancia Cinemagnética/instrumentación , Imagen de Cuerpo Entero/instrumentación , Diseño de Equipo , Europa (Continente) , Humanos , Interpretación de Imagen Asistida por Computador , Fantasmas de Imagen , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Factores de Tiempo
17.
J Cardiovasc Magn Reson ; 14: 50, 2012 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-22839417

RESUMEN

BACKGROUND: Cardiovascular magnetic resonance (CMR) is the gold standard non-invasive method for determining left ventricular (LV) mass and volume but has not been used previously to characterise the LV remodeling response in aortic stenosis. We sought to investigate the degree and patterns of hypertrophy in aortic stenosis using CMR. METHODS: Patients with moderate or severe aortic stenosis, normal coronary arteries and no other significant valve lesions or cardiomyopathy were scanned by CMR with valve severity assessed by planimetry and velocity mapping. The extent and patterns of hypertrophy were investigated using measurements of the LV mass index, indexed LV volumes and the LV mass/volume ratio. Asymmetric forms of remodeling and hypertrophy were defined by a regional wall thickening ≥ 13 mm and >1.5-fold the thickness of the opposing myocardial segment. RESULTS: Ninety-one patients (61 ± 21 years; 57 male) with aortic stenosis (aortic valve area 0.93 ± 0.32 cm2) were recruited. The severity of aortic stenosis was unrelated to the degree (r2=0.012, P=0.43) and pattern (P=0.22) of hypertrophy. By univariate analysis, only male sex demonstrated an association with LV mass index (P=0.02). Six patterns of LV adaption were observed: normal ventricular geometry (n=11), concentric remodeling (n=11), asymmetric remodeling (n=11), concentric hypertrophy (n=34), asymmetric hypertrophy (n=14) and LV decompensation (n=10). Asymmetric patterns displayed considerable overlap in appearances (wall thickness 17 ± 2mm) with hypertrophic cardiomyopathy. CONCLUSIONS: We have demonstrated that in patients with moderate and severe aortic stenosis, the pattern of LV adaption and degree of hypertrophy do not closely correlate with the severity of valve narrowing and that asymmetric patterns of wall thickening are common.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico , Cardiomiopatía Hipertrófica/diagnóstico , Hipertrofia Ventricular Izquierda/diagnóstico , Imagen por Resonancia Cinemagnética/métodos , Función Ventricular Izquierda , Remodelación Ventricular , Anciano , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/fisiopatología , Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/fisiopatología , Diagnóstico Diferencial , Femenino , Ventrículos Cardíacos/patología , Ventrículos Cardíacos/fisiopatología , Humanos , Hipertrofia Ventricular Izquierda/etiología , Hipertrofia Ventricular Izquierda/fisiopatología , Masculino , Persona de Mediana Edad
18.
J Cardiovasc Magn Reson ; 14: 86, 2012 Dec 24.
Artículo en Inglés | MEDLINE | ID: mdl-23259835

RESUMEN

BACKGROUND: Myocardial disarray is an important histological feature of hypertrophic cardiomyopathy (HCM) which has been studied post-mortem, but its in-vivo prevalence and extent is unknown. Cardiac Diffusion Tensor Imaging (cDTI) provides information on mean intravoxel myocyte orientation and potentially myocardial disarray. Recent technical advances have improved in-vivo cDTI, and the aim of this study was to assess the interstudy reproducibility of quantitative in-vivo cDTI in patients with HCM. METHODS AND RESULTS: A stimulated-echo single-shot-EPI sequence with zonal excitation and parallel imaging was implemented. Ten patients with HCM were each scanned on 2 different days. For each scan 3 short axis mid-ventricular slices were acquired with cDTI at end systole. Fractional anisotropy (FA), mean diffusivity (MD), and helix angle (HA) maps were created using a cDTI post-processing platform developed in-house. The mean ± SD global FA was 0.613 ± 0.044, MD was 0.750 ± 0.154 × 10-3 mm2/s and HA was epicardium -34.3 ± 7.6°, mesocardium 3.5 ± 6.9° and endocardium 38.9 ± 8.1°. Comparison of initial and repeat studies showed global interstudy reproducibility for FA (SD = ± 0.045, Coefficient of Variation (CoV) = 7.2%), MD (SD = ± 0.135 × 10-3 mm2/s, CoV = 18.6%) and HA (epicardium SD = ± 4.8°; mesocardium SD = ± 3.4°; endocardium SD = ± 2.9°). Reproducibility of FA was superior to MD (p = 0.003). MD was significantly higher in the septum than the reference lateral wall (0.784 ±0.188 vs 0.714 ±0.155 ×10-3 mm2/s, p <0.001) [corrected]. Septal HA was significantly lower than the reference lateral wall in all 3 transmural layers (from -8.3° to -10.4°, all p < 0.001). CONCLUSIONS: To the best of our knowledge, this is the first study to assess the interstudy reproducibility of DTI in the human HCM heart in-vivo and the largest cDTI study in HCM to date. Our results show good reproducibility of FA, MD and HA which indicates that current technology yields robust in-vivo measurements that have potential clinical value. The interpretation of regional differences in the septum requires further investigation.


Asunto(s)
Cardiomiopatía Hipertrófica/diagnóstico , Imagen de Difusión Tensora , Miocardio/patología , Función Ventricular Izquierda , Anciano , Cardiomiopatía Hipertrófica/patología , Cardiomiopatía Hipertrófica/fisiopatología , Medios de Contraste , Femenino , Fibrosis , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Volumen Sistólico
19.
J Cardiovasc Magn Reson ; 13: 7, 2011 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-21235751

RESUMEN

BACKGROUND: Phase contrast cardiovascular magnetic resonance (CMR) is able to measure all three directional components of the velocities of blood flow relative to the three spatial dimensions and the time course of the heart cycle. In this article, methods used for the acquisition, visualization, and quantification of such datasets are reviewed and illustrated. METHODS: Currently, the acquisition of 3D cine (4D) phase contrast velocity data, synchronized relative to both cardiac and respiratory movements takes about ten minutes or more, even when using parallel imaging and optimized pulse sequence design. The large resulting datasets need appropriate post processing for the visualization of multidirectional flow, for example as vector fields, pathlines or streamlines, or for retrospective volumetric quantification. APPLICATIONS: Multidirectional velocity acquisitions have provided 3D visualization of large scale flow features of the healthy heart and great vessels, and have shown altered patterns of flow in abnormal chambers and vessels. Clinically relevant examples include retrograde streams in atheromatous descending aortas as potential thrombo-embolic pathways in patients with cryptogenic stroke and marked variations of flow visualized in common aortic pathologies. Compared to standard clinical tools, 4D velocity mapping offers the potential for retrospective quantification of flow and other hemodynamic parameters. CONCLUSIONS: Multidirectional, 3D cine velocity acquisitions are contributing to the understanding of normal and pathologically altered blood flow features. Although more rapid and user-friendly strategies for acquisition and analysis may be needed before 4D velocity acquisitions come to be adopted in routine clinical CMR, their capacity to measure multidirectional flows throughout a study volume has contributed novel insights into cardiovascular fluid dynamics in health and disease.


Asunto(s)
Vasos Sanguíneos/fisiopatología , Enfermedades Cardiovasculares/diagnóstico , Circulación Coronaria , Corazón/fisiopatología , Interpretación de Imagen Asistida por Computador , Imagenología Tridimensional , Imagen por Resonancia Cinemagnética , Velocidad del Flujo Sanguíneo , Enfermedades Cardiovasculares/fisiopatología , Humanos , Valor Predictivo de las Pruebas , Flujo Sanguíneo Regional , Mecánica Respiratoria , Factores de Tiempo
20.
J Cardiovasc Magn Reson ; 13: 48, 2011 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-21914185

RESUMEN

There were 75 articles published in the Journal of Cardiovascular Magnetic Resonance (JCMR) in 2010, which is a 34% increase in the number of articles since 2009. The quality of the submissions continues to increase, and the editors were delighted with the recent announcement of the JCMR Impact Factor of 4.33 which showed a 90% increase since last year. Our acceptance rate is approximately 30%, but has been falling as the number of articles being submitted has been increasing. In accordance with Open-Access publishing, the JCMR articles go on-line as they are accepted with no collating of the articles into sections or special thematic issues. Last year for the first time, the Editors summarized the papers for the readership into broad areas of interest or theme, which we felt would be useful to practitioners of cardiovascular magnetic resonance (CMR) so that you could review areas of interest from the previous year in a single article in relation to each other and other recent JCMR articles 1. This experiment proved very popular with a very high rate of downloading, and therefore we intend to continue this review annually. The papers are presented in themes and comparison is drawn with previously published JCMR papers to identify the continuity of thought and publication in the journal. We hope that you find the open-access system increases wider reading and citation of your papers, and that you will continue to send your quality manuscripts to JCMR for publication.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico , Imagen por Resonancia Magnética , Publicaciones Periódicas como Asunto , Animales , Enfermedades Cardiovasculares/fisiopatología , Políticas Editoriales , Humanos , Factor de Impacto de la Revista , Valor Predictivo de las Pruebas , Pronóstico , Índice de Severidad de la Enfermedad
SELECCIÓN DE REFERENCIAS