Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Am J Obstet Gynecol ; 230(1S): S46, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38355237

RESUMEN

This article has been retracted: please see Elsevier Policy on Article Withdrawal (https://www.elsevier.com/about/policies/article-withdrawal). This meeting abstract has been retracted at the request of the authors. The team determined further analysis is warranted before the formal presentation of the results.

2.
Sensors (Basel) ; 22(22)2022 Nov 09.
Artículo en Inglés | MEDLINE | ID: mdl-36433258

RESUMEN

This study presents a multi-gas analyzer based on tunable filter non-dispersive IR (TF-NDIR) sensors that operate with a wide dynamic range of wavelength and concentration. A pyroelectric sensor coupled with a microsized Fabry-Perot interferometer, namely a tunable filter, enables sensing within a narrowly selected wavelength band. Three detectors capable of tuning the bandpass wavelength with a range of 3.8-5.0 µm, 5.5-8.0 µm, and 8.0-10.5 µm are combined to encompass the entire mid-IR region. single-pass cell with an optical path length (OPL) of 5 cm and a multi-pass cell with an OPL of 10.5 m is selected to encompass a concentration range from ppmv to percent. The TF-NDIR sensors and gas cells can be reconfigured by manipulating the beam path. A homemade lock-in amplifier is used to enhance the signal-to-noise ratio 88 times greater than that of the bare signal. The performance of the gas analyzer is evaluated by measuring the SF6 and Novec-4710/CO2 mixture, which are the dielectric gas medium for a gas-insulated switch (GIS). The mixing ratio of the Novec-4710/CO2 mixture is measured within a range of 3-7% using premixes. The measurement precision is 0.72% for 0.5 s. Trace level measurements of Novec-4710, CO2, SF6, which are measurands for detecting gas leakage from the GIS, CO, and SO2 which are measurands for detecting product generated by the arc or thermal decomposition in the switching electrode, are conducted based on dynamic partial pressure adjustment using 1000 ppmv mother premixes in N2. The limit of detection is 54.7 ppmv for Novec-4710, 112.8 ppmv for CO, 118.1 ppmv for CO2, 69.5 ppmv for SO2, and 33.5 ppmv for SF6.


Asunto(s)
Ácido Aminosalicílico , Dióxido de Carbono , Amplificadores Electrónicos , Citoplasma , Electrodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA