Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Clin Microbiol ; 55(7): 2180-2187, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28468860

RESUMEN

Screening of blood for human T-cell lymphotropic virus type 1 and type 2 (HTLV-1 and -2, respectively) is important to diagnose and prevent infection and ensure the safety of blood supplies. The Elecsys HTLV-I/II assay is a newly developed, electrochemiluminescence screening assay for the detection of HTLV-1/2 infection. The sensitivity and specificity of the Elecsys HTLV-I/II assay were determined using well-characterized HTLV-1/2-positive serum and plasma samples and routine diagnostic and blood donor samples expected to be HTLV negative, respectively. These results were compared with those for at least one of the following CE-marked assays at seven independent laboratories and the Roche Diagnostics facility in Penzberg, Germany: Abbott Architect rHTLV-I/II, Ortho Avioq HTLV-I/II Microelisa system, Abbott Prism HTLV-I/HTLV-II, and DiaSorin Murex HTLV I+II. Fujirebio INNO-LIA HTLV-I/II Score was used as a confirmatory assay. The Elecsys HTLV-I/II, Abbott Architect rHTLV-I/II, and Abbott Prism HTLV-I/HTLV-II assays detected all HTLV-1/2-positive samples (sensitivity, 100%). Sensitivity for Ortho Avioq HTLV-I/II was 98.63%. The Elecsys HTLV-I/II assay had a specificity of 99.95% in blood donor samples, which was comparable to results for the other assays (range, 99.91 to 100%). In routine diagnostic samples, the specificity of the Elecsys HTLV-I/II assay was 99.83%, compared with 99.70% for Abbott Architect rHTLV-I/II. Specificity for the Elecsys HTLV-I/II assay in potentially cross-reactive samples was 100%, compared with 99.0% for Ortho Avioq HTLV-I/II and 99.2% for DiaSorin Murex HTLV I+II. The Elecsys HTLV-I/II assay has the sensitivity and specificity to support its use as a routine screening assay for detecting HTLV infection.


Asunto(s)
Sangre/virología , Infecciones por HTLV-I/diagnóstico , Infecciones por HTLV-II/diagnóstico , Virus Linfotrópico T Tipo 1 Humano/aislamiento & purificación , Virus Linfotrópico T Tipo 2 Humano/aislamiento & purificación , Tamizaje Masivo/métodos , Europa (Continente) , Humanos , Japón , Mediciones Luminiscentes/métodos , Sensibilidad y Especificidad
2.
J Clin Virol ; 156: 105293, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36126395

RESUMEN

BACKGROUND: The diagnostic accuracy of the Elecsys® HCV Duo antigen-antibody combination immunoassay (Roche Diagnostics GmbH) was evaluated for the detection of hepatitis C virus (HCV) infection, versus commercially available comparators. METHODS: This multicenter study (August 2020-March 2021) assessed the specificity of the Elecsys HCV Duo immunoassay and comparator assays in blood donor and routine clinical laboratory samples; sensitivity was determined in confirmed HCV-positive samples and seroconversion panels. The Elecsys HCV Duo immunoassay was compared with the Monolisa HCV Ag-Ab ULTRA V2, Murex HCV Ag/Ab Combination and ARCHITECT HCV Ag assays, as well as nucleic acid testing (NAT). The antibody (anti-HCV) module of the Elecsys HCV Duo immunoassay was compared with the Elecsys Anti-HCV II, Alinity s Anti-HCV, ARCHITECT Anti-HCV and RIBA HCV 3.0 SIA assays. RESULTS: The specificity of the Elecsys HCV Duo immunoassay was 99.94% (95% confidence interval [CI], 99.89-99.97) and 99.92% (95% CI, 99.71-99.99) in blood donor (n = 20,634) and routine clinical laboratory samples (n = 2531), respectively. The specificity of the Elecsys HCV Duo immunoassay was similar or better than comparator assays. The sensitivity of the Elecsys HCV Duo immunoassay in confirmed HCV-positive samples (n = 257) was 99.6%. In seroconversion panels, the Elecsys HCV Duo immunoassay detected infections earlier (2.2-21.9 days) than all but one of the comparator assays and detected HCV 1.8 days later than NAT. CONCLUSIONS: The Elecsys HCV Duo immunoassay shows high diagnostic accuracy, reduces the diagnostic window, and could be used when NAT is not possible.


Asunto(s)
Hepatitis C , Ácidos Nucleicos , Hepacivirus , Anticuerpos contra la Hepatitis C , Humanos , Inmunoensayo , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA