Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Shoulder Elbow Surg ; 33(1): 73-81, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37379964

RESUMEN

BACKGROUND: Instability after reverse shoulder arthroplasty (RSA) is one of the most frequent complications and remains a clinical challenge. Current evidence is limited by small sample size, single-center, or single-implant methodologies that limit generalizability. We sought to determine the incidence and patient-related risk factors for dislocation after RSA, using a large, multicenter cohort with varying implants. METHODS: A retrospective, multicenter study was performed involving 15 institutions and 24 American Shoulder and Elbow Surgeons members across the United States. Inclusion criteria consisted of patients undergoing primary or revision RSA between January 2013 and June 2019 with minimum 3-month follow-up. All definitions, inclusion criteria, and collected variables were determined using the Delphi method, an iterative survey process involving all primary investigators requiring at least 75% consensus to be considered a final component of the methodology for each study element. Dislocations were defined as complete loss of articulation between the humeral component and the glenosphere and required radiographic confirmation. Binary logistic regression was performed to determine patient predictors of postoperative dislocation after RSA. RESULTS: We identified 6621 patients who met inclusion criteria with a mean follow-up of 19.4 months (range: 3-84 months). The study population was 40% male with an average age of 71.0 years (range: 23-101 years). The rate of dislocation was 2.1% (n = 138) for the whole cohort, 1.6% (n = 99) for primary RSAs, and 6.5% (n = 39) for revision RSAs (P < .001). Dislocations occurred at a median of 7.0 weeks (interquartile range: 3.0-36.0 weeks) after surgery with 23.0% (n = 32) after a trauma. Patients with a primary diagnosis of glenohumeral osteoarthritis with an intact rotator cuff had an overall lower rate of dislocation than patients with other diagnoses (0.8% vs. 2.5%; P < .001). Patient-related factors independently predictive of dislocation, in order of the magnitude of effect, were a history of postoperative subluxations before radiographically confirmed dislocation (odds ratio [OR]: 19.52, P < .001), primary diagnosis of fracture nonunion (OR: 6.53, P < .001), revision arthroplasty (OR: 5.61, P < .001), primary diagnosis of rotator cuff disease (OR: 2.64, P < .001), male sex (OR: 2.21, P < .001), and no subscapularis repair at surgery (OR: 1.95, P = .001). CONCLUSION: The strongest patient-related factors associated with dislocation were a history of postoperative subluxations and having a primary diagnosis of fracture nonunion. Notably, RSAs for osteoarthritis showed lower rates of dislocations than RSAs for rotator cuff disease. These data can be used to optimize patient counseling before RSA, particularly in male patients undergoing revision RSA.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Luxaciones Articulares , Osteoartritis , Articulación del Hombro , Humanos , Masculino , Anciano , Femenino , Artroplastía de Reemplazo de Hombro/efectos adversos , Artroplastía de Reemplazo de Hombro/métodos , Articulación del Hombro/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Osteoartritis/cirugía , Luxaciones Articulares/cirugía , Rango del Movimiento Articular
2.
J Shoulder Elbow Surg ; 32(7): 1420-1431, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37003429

RESUMEN

BACKGROUND: Lateralization in reverse total shoulder arthroplasty (RTSA) has been used to theoretically offer the potential benefits of reduced scapular notching rates and improved stability and range of motion (ROM), particularly external rotation. The aim of this study was to compare ROM and clinical and radiographic outcomes between patients who underwent RTSA with a lateralized vs. a nonlateralized and distalized glenosphere. METHODS: A single-surgeon randomized control trial was conducted comparing 27 patients with a lateralized glenosphere and 26 patients with a nonlateralized and distalized glenosphere. A total of 66 patients were enrolled, 2 patients died before 2-year follow-up, 4 patients withdrew from the study, and 7 patients were lost to follow-up. All patients in the lateralized group received 6 mm of lateralization through the glenosphere. Participants represented a population presenting to an orthopedics sports medicine clinic with any indication for RTSA including revision arthroplasty. Patients completed preoperative and routine postoperative functional outcome measures 3, 6, 12, and a minimum of 24 months postoperatively, including American Shoulder and Elbow Surgeons, Patient-Reported Outcomes Measurement Information System Physical Function Upper Extremity, and Activities of Daily Living Requiring Active External and Internal Rotation assessments. Patients were also evaluated with ROM and radiographic measurements. The primary outcome of interest in this study was ROM, particularly external rotation. RESULTS: At 2-year follow-up, both groups had significant improvement in their American Shoulder and Elbow Surgeons, Patient-Reported Outcomes Measurement Information System Physical Function Upper Extremity, and Activities of Daily Living Requiring Active External and Internal Rotation scores with no significant difference observed between the groups. There were no statistically significant differences in incidence of scapular notching or acromial stress fractures. ROM in both groups improved significantly at their 2-year assessment with the only exception to this being external rotation at 90° of abduction in the nonlateralized and distalized group (39° ± 31° vs. 48° ± 24°, P = .379). CONCLUSIONS: Regardless of glenosphere lateralization status, patients in both groups had significant improvement in functional outcome scores and ROM, and there were no significant differences observed between the groups at 2-year follow-up. Longer follow-up is needed to determine the effect of implant design on late complications, long-term outcomes, and implant retention.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Articulación del Hombro , Prótesis de Hombro , Humanos , Artroplastía de Reemplazo de Hombro/efectos adversos , Prótesis de Hombro/efectos adversos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Actividades Cotidianas , Estudios Retrospectivos
3.
J Shoulder Elbow Surg ; 32(12): 2483-2492, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37330167

RESUMEN

BACKGROUND: Both patient and implant related variables have been implicated in the incidence of acromial (ASF) and scapular spine fractures (SSF) following reverse shoulder arthroplasty (RSA); however, previous studies have not characterized nor differentiated risk profiles for varying indications including primary glenohumeral arthritis with intact rotator cuff (GHOA), rotator cuff arthropathy (CTA), and massive irreparable rotator cuff tear (MCT). The purpose of this study was to determine patient factors predictive of cumulative ASF/SSF risk for varying preoperative diagnosis and rotator cuff status. METHODS: Patients consecutively receiving RSA between January 2013 and June 2019 from 15 institutions comprising 24 members of the American Shoulder and Elbow Surgeons (ASES) with primary, preoperative diagnoses of GHOA, CTA and MCT were included for study. Inclusion criteria, definitions, and inclusion of patient factors in a multivariate model to predict cumulative risk of ASF/SSF were determined through an iterative Delphi process. The CTA and MCT groups were combined for analysis. Consensus was defined as greater than 75% agreement amongst contributors. Only ASF/SSF confirmed by clinical and radiographic correlation were included for analysis. RESULTS: Our study cohort included 4764 patients with preoperative diagnoses of GHOA, CTA, or MCT with minimum follow-up of 3 months (range: 3-84). The incidence of cumulative stress fracture was 4.1% (n = 196). The incidence of stress fracture in the GHOA cohort was 2.1% (n = 34/1637) compared to 5.2% (n = 162/3127) (P < .001) in the CTA/MCT cohort. Presence of inflammatory arthritis (odds ratio [OR] 2.90, 95% confidence interval [CI] 1.08-7.78; P = .035) was the sole predictive factor of stress fractures in GHOA, compared with inflammatory arthritis (OR 1.86, 95% CI 1.19-2.89; P = .016), female sex (OR 1.81, 95% CI 1.20-2.72; P = .007), and osteoporosis (OR 1.56, 95% CI 1.02-2.37; P = .003) in the CTA/MCT cohort. CONCLUSION: Preoperative diagnosis of GHOA has a different risk profile for developing stress fractures after RSA than patients with CTA/MCT. Though rotator cuff integrity is likely protective against ASF/SSF, approximately 1/46 patients receiving RSA with primary GHOA will have this complication, primarily influenced by a history of inflammatory arthritis. Understanding risk profiles of patients undergoing RSA by varying diagnosis is important in counseling, expectation management, and treatment by surgeons.


Asunto(s)
Artritis , Artroplastía de Reemplazo de Hombro , Fracturas por Estrés , Lesiones del Manguito de los Rotadores , Articulación del Hombro , Femenino , Humanos , Artritis/cirugía , Artroplastía de Reemplazo de Hombro/efectos adversos , Fracturas por Estrés/diagnóstico por imagen , Fracturas por Estrés/etiología , Rango del Movimiento Articular , Estudios Retrospectivos , Factores de Riesgo , Lesiones del Manguito de los Rotadores/complicaciones , Lesiones del Manguito de los Rotadores/diagnóstico por imagen , Lesiones del Manguito de los Rotadores/cirugía , Escápula/diagnóstico por imagen , Escápula/cirugía , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Resultado del Tratamiento , Masculino
4.
J Shoulder Elbow Surg ; 30(10): 2296-2305, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33677115

RESUMEN

BACKGROUND: Acromial (ASF) and scapular spine (SSF) stress fractures are well-recognized complications of reverse shoulder arthroplasty (RSA), but much of the current data are derived from single-center or single-implant studies with limited generalizability. This study from the American Shoulder and Elbow Surgeons (ASES) Complications of Reverse Shoulder Arthroplasty Multicenter Research Group determined the incidence of ASF/SSF after RSA and identified preoperative patient characteristics associated with their occurrence. METHOD: Fifteen institutions including 21 ASES members across the United States participated in this study. Patients undergoing either primary or revision RSA between January 2013 and June 2019 with a minimum 3-month follow-up were included. All definitions and inclusion criteria were determined using the Delphi method, an iterative survey process involving all primary investigators. Consensus was achieved when at least 75% of investigators agreed on each aspect of the study protocol. Only symptomatic ASF/SSF diagnosed by radiograph or computed tomography were considered. Multivariable logistic regression was performed to identify factors associated with ASF/SSF development. RESULTS: We identified 6755 RSAs with an average follow-up of 19.8 months (range, 3-94). The total stress fracture incidence rate was 3.9% (n = 264), of which 3.0% (n = 200) were ASF and 0.9% (n = 64) were SSF. Fractures occurred at an average 8.2 months (0-64) following RSA with 21.2% (n = 56) following a trauma. Patient-related factors independently predictive of ASF were chronic dislocation (odds ratio [OR] 3.67, P = .04), massive rotator cuff tear without arthritis (OR 2.51, P < .01), rotator cuff arthropathy (OR 2.14, P < .01), self-reported osteoporosis (OR 2.21, P < .01), inflammatory arthritis (OR 2.18, P < .01), female sex (OR 1.51, P = .02), and older age (OR 1.02 per 1-year increase, P = .02). Factors independently associated with the development of SSF included osteoporosis (OR 2.63, P < .01), female sex (OR 2.34, P = .01), rotator cuff arthropathy (OR 2.12, P = .03), and inflammatory arthritis (OR 2.05, P = .03). CONCLUSION: About 1 in 26 patients undergoing RSA will develop a symptomatic ASF or SSF, more frequently within the first year of surgery. Our results indicate that severe rotator cuff disease may play an important role in the occurrence of stress fractures following RSA. This information can be used to counsel patients about potential setbacks in recovery, especially among older women with suboptimal bone health. Strategies for prevention of ASF and SSF in these at-risk patients warrant further study. A follow-up study evaluating the impact of prosthetic factors on the incidence rates of ASF and SSF may prove highly valuable in the decision-making process.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Fracturas por Estrés , Lesiones del Manguito de los Rotadores , Articulación del Hombro , Anciano , Artroplastía de Reemplazo de Hombro/efectos adversos , Femenino , Estudios de Seguimiento , Fracturas por Estrés/diagnóstico por imagen , Fracturas por Estrés/epidemiología , Fracturas por Estrés/etiología , Humanos , Rango del Movimiento Articular , Estudios Retrospectivos , Articulación del Hombro/cirugía , Resultado del Tratamiento
5.
JSES Rev Rep Tech ; 4(3): 413-418, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39157255

RESUMEN

Background: Determine the effect of a novel acellular cannulated dermal allograft on tendon-to-bone healing, retear rates, and clinical outcomes over a 12-month period. Methods: This was a single surgeon prospective nonrandomized case series. Patients with medium sized full-thickness superior and posterosuperior rotator cuff tears, as confirmed by magnetic resonance imaging, were consented. Patients were excluded if they had fatty atrophy indicative of Goutallier grade III or IV. The allograft is a cannulated rectangular prism that has a 5-year shelf life, does not require prehydration, and does not need to be trimmed to size. Outcome metrics included ultrasound assessment at 1-year as well as 6-month patient-reported outcomes (PROs) scores. Results: 31 patients consented and enrolled in this consecutive cohort series. 9 patients were excluded, and statistical analysis was performed on the remaining 22 patients. There were 9 females and 13 males. The average age was 59.27 ± 7.48 year old. The average supraspinatus short axis measurement in males was 0.56 ± 0.12 cm and 0.52 ± 0.09 cm in females (P = .44). The average supraspinatus long axis measurement in males was 0.61 ± 0.18 cm and 0.55 ± 0.14 cm in females (P = .46). The average infraspinatus short axis measurement in males was 0.48 ± 0.10 cm and 0.50 ± 0.13 in females (P = .74). The average infraspinatus long axis measurement in males was 0.44 ± 0.12 cm and 0.43 ± 0.08 cm in females (P = .84). Of the 19 patients who completed baseline and 6-month PRO's, 17 achieved the minimal clinical important difference for American Shoulder and Elbow Surgeons and Patient-Reported Outcomes Measurement Information SystemUE 7a. Retear occurred in 2 cases. The remaining 20 cases have all demonstrated healing or fully healed repairs at their most recent clinical visits with no additional cases of retears. Conclusion: This study is the first to report the results of a novel acellular dermal allograft for rotator cuff repair augmentation. Satisfactory PRO measures and robust tendon healing at 1 year, as measured by ultrasound, demonstrate the utility of a cannulated human acellular dermal allograft as a viable biologic augmentation device for rotator cuff repair.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA