Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Rev Sci Instrum ; 79(5): 053506, 2008 May.
Artículo en Inglés | MEDLINE | ID: mdl-18513068

RESUMEN

A new technique to measure the first and second derivatives of the ion temperature profile has been developed by using a charge exchange spectroscopy system with space modulation optics. The space observed is scanned up to +/-3 cm with a cosine wave modulation frequency up to 30 Hz by shifting the object lens in front of the optical fiber bundle by 0.5 mm with a piezoelement. The first and second derivatives of ion temperature are derived from the modulation component of the ion temperature measured by using Fourier series expansion.

2.
Rev Sci Instrum ; 79(2 Pt 2): 02A512, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18315133

RESUMEN

We have been developing a test stand for fast He(0) beam production. One of the major issues is how to transport effectively the He(+) and He(-) beams from which the He(0) beam is produced. The beam should be focused in two transverse focal points, the center of the charge exchange cell and the electrostatic accelerator. We studied the beam transport system and effect of space charge neutralization in the test stand by experiments and calculation.

3.
Rev Sci Instrum ; 79(2 Pt 2): 02C113, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18315239

RESUMEN

A strongly focusing high-intensity He(+) ion source has been designed and constructed as a beam source for a high-energy He(0) beam probe system for diagnosis of fusion produced alpha particles in the thermonuclear fusion plasmas. The He(+) beam was extracted from the ion source at an acceleration voltage of 18-35 kV. Temperature distributions of the beam target were observed with an IR camera. The 1/e-holding beam profile half-width was about 15 mm at optimum perveance (Perv) of 0.03 (I(beam)=2.4 A). A beam current about 3 A was achieved at an acceleration voltage of 26.7 kV with an arc power of 10 kW (Perv=0.023).

4.
Rev Sci Instrum ; 89(11): 113509, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30501311

RESUMEN

In the currently performed neutral beam (NB) -heated deuterium plasma experiments, neutrons are mainly produced by a beam-plasma reaction. Therefore, time-resolved measurement of the neutron emission profile can enhance the understanding of the classical and/or anomalous transport of beam ions. To measure radial neutron emission profiles as a function of time, the vertical neutron camera (VNC) capable of operation with a counting rate in the MHz range was newly installed on the Large Helical Device (LHD). This is the world's first neutron camera for stellarator/heliotron devices. The VNC consists of a multichannel collimator, eleven fast-neutron detectors, and the digital-signal-processing-based data acquisition system (DAQ). The multichannel collimator having little cross talk was made from hematite-doped heavy concrete, which has a high shielding performance against both neutrons and gamma-rays. A stilbene crystal coupled with a photomultiplier having high-gain-stability in the high-count rate regime was utilized as a fast-neutron scintillation detector because it has a high neutron-gamma discrimination capability at high count rates. The DAQ system equipped with a field programmable logic controller was developed to obtain the waveform acquired with a 1 GHz sampling rate and the shaping parameter of each pulse simultaneously at up to 106 cps (counts per second). Neutron emission profiles were successfully obtained in the first deuterium campaign of LHD in 2017. The neutron emission profile was measured in tangentially co-injected NB-heated plasma with different magnetic axes (R ax). The neutron counts became larger in the inward-shifted configuration, which was consistent with the total neutron rate measured by the neutron flux monitor. The radial peak position of the line-integrated neutron profile which changed according to R ax showed that the VNC worked successfully as designed. The VNC demonstrated the expected performance conducive to extending energetic-particle physics studies in LHD.

5.
Rev Sci Instrum ; 85(11): 11E110, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25430289

RESUMEN

The neutron profile monitor stably operated at a high-count-rate for deuterium operations in the Large Helical Device has been developed to enhance the research on the fast-ion confinement. It is composed of a multichannel collimator, scintillation-detectors, and a field programmable gate array circuit. The entire neutron detector system was tested using an accelerator-based neutron generator. This system stably acquires the pulse data without any data loss at high-count-rate conditions up to 8 × 10(5) counts per second.

6.
Rev Sci Instrum ; 85(11): 11E114, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25430293

RESUMEN

A fast time response, wide dynamic range neutron flux monitor has been developed toward the LHD deuterium operation by using leading-edge signal processing technologies providing maximum counting rate up to ∼5 × 10(9) counts/s. Because a maximum total neutron emission rate over 1 × 10(16) n/s is predicted in neutral beam-heated LHD plasmas, fast response and wide dynamic range capabilities of the system are essential. Preliminary tests have demonstrated successful performance as a wide dynamic range monitor along the design.

7.
Rev Sci Instrum ; 83(2): 02B120, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22380277

RESUMEN

A strongly focusing He(+) ion beam source equipped with concave multi-aperture electrodes was developed for production of He(-) through a charge exchange cell. The beam was extracted at a voltage less than 20 kV from 301 apertures distributed in an area of 100 mm φ, and focused at 750 mm distance. The beam current and the beam size of 2 A and 20 mm in diameter, respectively, were achieved with an arc power less than 10 kW. The optimum perveance was obtained at 0.02 A∕kV(1.5) at the beam energy less than 20 keV which is suitable for the conversion to He(-) in an alkali vapor cell.

8.
Rev Sci Instrum ; 83(2): 02B718, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22380323

RESUMEN

An energetic helium neutral beam is involved in the beam neutralization measurement system of alpha particles confined in a DT fusion plasma. A full size strong-focusing He(+) ion source (2 A, the beam radius of 11.3 mm, the beam energy less than 20 keV). Present strong-focusing He(+) ion source shows an emittance diagram separated for each beamlet of multiple apertures without phase space mixing, despite the space charge of a beamlet is asymmetric and the beam flow is non-laminar. The emittance of beamlets in the peripheral region was larger than that of center. The heat load to the plasma electrode was studied to estimate the duty factor for the ITER application.

9.
Rev Sci Instrum ; 81(2): 02B115, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20192421

RESUMEN

The phase space distribution of a strongly focused He(+) ion beam source equipped with concave multiaperture electrodes was measured using a pepper-pot plate and a Kapton foil. The substructure of 301 merging He beamlets was clearly observed on a footprint of pepper-pot hole at the beam waist, where the beam density was 500 mA/cm(2). The position and the width of each beamlet substructure show the effect of interference of beamlets with surrounding one.

10.
Rev Sci Instrum ; 79(10): 10E929, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19044584

RESUMEN

Energy resolved soft x-ray imaging system using a charge coupled device camera and a multifilter disk has recently been installed to the Large Helical Device for the measurements in the long pulse discharges. Eight images with different cutoff energies are measured sequentially during a single discharge by rotating a filter disk mounting eight beryllium filters with different thicknesses. A tangential line-integrated profile for a specific photon energy range can be obtained by taking intensity difference between two images measured with a filter pair of adjacent thicknesses. The typical photon energy corresponding to each difference ranges from 1.9 to 4.8 keV with the bandwidth of 2-3 keV. In the initial results, the difference in the line-integrated soft x-ray profile by the energy range has been clearly observed. This diagnostic method can possibly be applied to the observation of the dependence of two dimensional soft x-ray profile on photon energy range especially if local non-Maxwellian component appears in electron energy distribution function.

11.
Rev Sci Instrum ; 79(10): 10E512, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19044496

RESUMEN

An orbit following calculation code with full gyromotion under the ITER magnetic field configuration has been developed to investigate escaping alpha particle orbits in ITER and to determine the geometrical arrangement for alpha particle detection. The code contained the full geometrical information of the first wall panels. It was carefully investigated whether an alpha particle escaping from the plasma through the last closed flux surface does not touch or intersect the first wall boundary before reaching the detection point. Candidates of blanket module modification have been studied to achieve effective measurement geometry for escaping alpha particle detection. The calculations showed that direct orbit loss and banana diffusion can be detected with a probe head recessed from the first wall surface.

12.
Phys Rev Lett ; 100(4): 045003, 2008 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-18352289

RESUMEN

Three states of a magnetic island are observed when the magnetic shear at the rational surface is modified using inductive current associated with the neutral beam current drive in the Large Helical Device. One state is the healed magnetic island with a zero island width. The second state is the saturated magnetic island with partial flattening of the T(e) profile. The third state is characterized by the global flattening of the T(e) profile in the core region. As the plasma assumes each of the three states consecutively through a bifurcation process a clear hysteresis in the relation between the size of the magnetic island and the magnetic shear is observed.

13.
Rev Sci Instrum ; 79(10): 10F316, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19044629

RESUMEN

A strongly focusing high-intensity He(+) ion source equipped with three concave electrodes has been designed and constructed as the beam source for a high-energy He(0) neutral beam probe system to diagnose fusion-produced alpha particles in thermonuclear fusion plasmas. The reduction of heat load onto the concave extraction electrodes is particularly important for a long pulse operation, as the heat load deforms the electrodes and thus the beam focal length. The effects on the arc efficiency (beam current/arc power) of the ion source due to the discharge filament structure (straight-type and L-shape-type filaments), size (filament diameters of 2 and 1.5 mm), number, and the locations have been studied. Choice of the appropriate filament structure improved the arc efficiency by 17%.

14.
Phys Rev Lett ; 101(5): 055003, 2008 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-18764400

RESUMEN

A spontaneous transition phenomena between two states of a plasma with an internal transport barrier (ITB) is observed in the steady-state phase of the magnetic shear in the negative magnetic shear plasma in the JT-60U tokamak. These two ITB states are characterized by different profiles of the second radial derivative of the ion temperature inside the ITB region (one has a weak concave shape and the other has a strong convex shape) and by different degrees of sharpness of the interfaces between the L mode and the ITB region, which is determined by the turbulence penetration into the ITB region.

15.
Phys Rev Lett ; 87(13): 135002, 2001 Sep 24.
Artículo en Inglés | MEDLINE | ID: mdl-11580597

RESUMEN

It was observed that the vacuum magnetic island produced by an external error magnetic field in the large helical device shrank in the presence of plasma. This was evidenced by the disappearance of flat regions in the electron temperature profile obtained by Thomson scattering. This island behavior depended on the magnetic configuration in which the plasmas were produced.

16.
Phys Rev Lett ; 88(5): 055005, 2002 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-11863738

RESUMEN

In the Large Helical Device plasma discharges, the size of an externally imposed island with mode number ( n/m = 1/1) decreases substantially when the plasma is collisionless ( nu(*)< approximately 1) and the beta is finite ( > approximately 0.1%) at the island location. For the collisional plasmas with finite beta, on the other hand, the size of the island increases. However, there is a threshold in terms of the vacuum island size below which the island enlargement is not seen.

17.
Phys Rev Lett ; 86(23): 5297-300, 2001 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-11384482

RESUMEN

Recent large helical device experiments revealed that the transition from ion root to electron root occurred for the first time in neutral-beam-heated discharges, where no nonthermal electrons exist. The measured values of the radial electric field were found to be in qualitative agreement with those estimated by neoclassical theory. A clear reduction of ion thermal diffusivity was observed after the mode transition from ion root to electron root as predicted by neoclassical theory when the neoclassical ion loss is more dominant than the anomalous ion loss.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA