Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Pacing Clin Electrophysiol ; 46(1): 73-83, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36433647

RESUMEN

BACKGROUND: The mitral L-wave, a prominent mid-diastolic filling wave in echocardiographic examinations, is associated with severe left ventricular diastolic dysfunction. The relationship between the mitral L-wave and outcome of catheter ablation (CA) in patients with atrial fibrillation (AF) has not been established. This study aimed to evaluate the predictive value of mitral L-waves on AF recurrence after CA. METHODS: This was a retrospective and observational study in a single center. One hundred forty-six patients (mean age; 63.9 [56.0-72.0] years, 71.9% male) including 66 non-paroxysmal AF patients (45.2%) who received a first CA were enrolled. The mitral L-waves were defined as a distinct mid-diastolic flow velocity with a peak velocity ≥20 cm/s following the E wave in the echocardiographic examinations before CA. The patients enrolled were divided into groups with (n = 31, 21.2%) and without (n = 115, 78.8%) mitral L-waves. Univariate and multivariate analyses were carried out to determine the predictive factors of late recurrences of AF (LRAFs), which meant AF recurrence later than 3 months after the CA. RESULTS: During a follow-up of 28.8 (15.0-35.8) months, the ratio of LRAFs in patients with mitral L-waves was significantly higher than that in those without mitral L-waves (15 [46.9%] vs. 16 [14.0%], p < .001). A multivariate analysis using a Cox proportional hazard model revealed that the mitral L-waves were a significant predictive factor of LRAFs (hazard ratio: 3.09, 95% confidence interval: 1.53-6.24, p = .002). CONCLUSION: The appearance of mitral L-waves could predict LRAFs after CA.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Disfunción Ventricular Izquierda , Humanos , Masculino , Femenino , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Estudios Retrospectivos , Ecocardiografía , Ablación por Catéter/efectos adversos , Recurrencia , Resultado del Tratamiento , Factores de Riesgo
2.
Pacing Clin Electrophysiol ; 45(3): 330-339, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35152453

RESUMEN

BACKGROUND: The inducibility of atrial fibrillation (AF) and incidence of nonpulmonary vein (nonPV) triggers in patients with heart failure (HF) have not been elucidated. Furthermore, the relationship between AF triggers and the change in the left ventricular (LV) function after catheter ablation (CA) remains unclear. METHODS: A total of 101 consecutive patients with a history of HF due to tachycardia who underwent CA of AF were prospectively enrolled (64.8 ± 10.7 years, male 72.3%, and paroxysmal AF 15.8%). According to the AF inducibility by isoproterenol (ISP), the patients were divided into two groups: inducible AF (66.3%) and noninducible AF (33.7%). Furthermore, inducible AF was categorized into a PV type (61.2%) and nonPV type (38.8%). This study investigated the AF recurrence and change in the LV ejection fraction (LVEF) after CA. RESULTS: AF recurred in 35 patients (34.7%) during the follow-up period (41.6 ± 26.8 months). Kaplan-Meier curves showed that patients with noninducible AF had just as bad an AF recurrence rate as those with the nonPV type. Cox proportional hazards models also revealed that noninducible AF (Hazard-ratio, 5.74; 95% CI, 1.81-18.13) was associated with a higher risk of recurrence. The LVEF significantly improved after the CA (from 49.1 ± 16.3% to 67.0 ± 7.9%). However, the nonPV type was associated with a lower improvement in the LVEF (Odds-ratio, 0.18; 95% CI, 0.05-0.70). CONCLUSION: The AF inducibility was associated with AF recurrence. Furthermore, the nonPV triggers were associated with a lesser improvement in the LVEF. Confirming the AF inducibility and triggers was important to predict the outcome after CA.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Insuficiencia Cardíaca , Ablación por Catéter/efectos adversos , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/cirugía , Humanos , Masculino , Recurrencia , Taquicardia/cirugía , Resultado del Tratamiento
3.
Pacing Clin Electrophysiol ; 44(11): 1861-1873, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34605033

RESUMEN

BACKGROUND: The predictive value of the cardio-ankle vascular index (CAVI) for estimating the efficacy outcome of catheter ablation (CA) in atrial fibrillation (AF) patients is unclear. We aimed to examine the predictive performance of the CAVI for recurrences of atrial arrhythmias after CA. METHODS: We enrolled a total of 193 patients with AF (paroxysmal 126 and non-paroxysmal 67) who underwent initial CA procedures at our institute, and CAVI measurements were conducted between January 2016 and March 2017. We evaluated recurrences of atrial arrhythmias after the first CA procedure as a clinical outcome. The CAVI value was assessed and the enrolled patients were divided according to the optimal CAVI value cut-off point (9.5) in the atrial arrhythmia recurrence group. RESULTS: During a mean follow-up of 31.3 (17.5-43.0) months, 74 (32.5%; PaAF 41 and 49.3%; non-PaAF 33) patients had recurrences of atrial arrhythmias. The recurrence ratio of atrial arrhythmias was significantly higher in patients with a high CAVI (≥9.5) than those with a low CAVI (<9.5) (log rank test; p = 0.018). A univariate analysis showed the association between higher CAVI values and recurrences of atrial arrhythmias (p = 0.072). Multivariate analyses using a Cox proportional hazard model after adjusting for other clinical factors revealed that the CAVI value was determined to be a significant predictive factor of a recurrence of atrial arrhythmias after CA (Hazard ratio: 1.44, 95% confidence interval: 1.17-1.78, p < 0.01). CONCLUSIONS: The CAVI was significantly associated with a recurrence of atrial arrhythmias after CA in AF patients.


Asunto(s)
Fibrilación Atrial/cirugía , Índice Vascular Cardio-Tobillo , Ablación por Catéter , Anciano , Femenino , Estudios de Seguimiento , Humanos , Japón , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Recurrencia , Estudios Retrospectivos , Factores de Riesgo
4.
Int Heart J ; 62(1): 87-94, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33518667

RESUMEN

Intracardiac defibrillation (IDF) is performed to restore sinus rhythm (SR) during radiofrequency catheter ablation (RFCA) of atrial fibrillation (AF). This study aimed to investigate the change in the IDF threshold before and after RFCA during the ablation procedure and determine whether the IDF threshold after RFCA was associated with the AF substrate and AF recurrence. A total of 141 consecutive patients with drug-refractory persistent AF (age 62.5 ± 10.3 years, 84.4% male) were enrolled in this study. Before RFCA, we initially performed IDF with an output of 1 J. When IDF failed to restore SR, the output was gradually increased to 30 J. After RFCA, we attempted pacing-induced AF to provoke other focuses of AF. When AF was induced, we performed IDF again to terminate AF with outputs of 1 to 30 J. The change in the IDF threshold to restore SR before and after RFCA was evaluated. After RFCA, the IDF threshold for restoring SR significantly decreased (from 11.5 ± 8.6 J to 4.0 ± 3.8 J, P < 0.001). During the follow-up (24.3 ± 12.2 months), SR was maintained in 107 patients (75.9%). The multivariate analysis using a Cox proportional-hazards model revealed that an IDF threshold of > 5 J after RFCA was significantly associated with the AF recurrence (HR, 3.99; 95% confidence interval 1.93-8.22; P = 0.0001). RFCA decreased the IDF threshold for restoring SR in patients with persistent AF. The IDF output of > 5 J after RFCA could be a predictor of AF recurrence independent of the AF substrate.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Cardioversión Eléctrica , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Recurrencia
5.
Int Heart J ; 61(5): 944-950, 2020 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-32921677

RESUMEN

Clinical experience with landiolol use in patients with atrial fibrillation (AF) and a severely depressed left ventricular (LV) function is limited. We compared the efficacy and safety of landiolol with that of digoxin as an intravenous drug in controlling the heart rate (HR) during AF associated with a very low LV ejection fraction (LVEF).We retrospectively analyzed 53 patients treated with landiolol (n = 34) or digoxin (n = 19) for AF tachycardias with an LVEF ≤ 25. The landiolol dose was adjusted between 0.5 and 10 µg/kg/minute according to the patient's condition. The response to treatment was defined as a decrease in the HR of ≤ 110/minute, and that decreased by ≥ 20% from baseline.There were no significant differences between the two groups regarding the clinical characteristics. The responder rate to landiolol at 24 hours was significantly higher than that to digoxin (71.0% versus 41.2%; odds ratio: 4.65, 95% confidence interval: 1.47-31.0, P = 0.048). The percent decrease in the HR from baseline at 1, 2, 12, and 24 hours was greater in the landiolol group than in the digoxin group (P < 0.01, P = 0.071, P = 0.036, and P = 0.016, respectively). The systolic blood pressure (SBP) from baseline within 24 hours after administering landiolol was significantly reduced, whereas digoxin did not decrease the SBP over time. Hypotension (< 80 mmHg) occurred in two patients in the landiolol group and 0 in the digoxin group (P = 0.53).Landiolol could be more effective in controlling the AF HR than digoxin even in patients with severely depressed LV function. However, careful hemodynamic monitoring is necessary when administering landiolol.


Asunto(s)
Antiarrítmicos/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Digoxina/uso terapéutico , Insuficiencia Cardíaca/fisiopatología , Frecuencia Cardíaca , Morfolinas/uso terapéutico , Taquicardia/tratamiento farmacológico , Urea/análogos & derivados , Disfunción Ventricular Izquierda/fisiopatología , Administración Intravenosa , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/etiología , Fibrilación Atrial/fisiopatología , Presión Sanguínea , Femenino , Insuficiencia Cardíaca/complicaciones , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Volumen Sistólico , Taquicardia/etiología , Taquicardia/fisiopatología , Resultado del Tratamiento , Urea/uso terapéutico , Disfunción Ventricular Izquierda/complicaciones
6.
Int Heart J ; 61(3): 510-516, 2020 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-32418969

RESUMEN

The transdermal bisoprolol patch (TB) was designed to maintain a sustained concentration of bisoprolol in plasma by a higher trough concentration than oral bisoporolol (OB). We compared the efficacy between TB and OB in patients with idiopathic premature ventricular contractions (PVCs) while considering their duration of action.A total of 78 patients with a PVC count of ≥ 3,000 beats/24 hours were divided into groups treated with TB 4 mg (n = 43) or OB 2.5 mg (n = 35). PVCs were divided into positive heart rate (HR) -dependent PVCs (P-PVCs) and non-positive HR-dependent PVCs (NP-PVCs) based on the relationship between the hourly PVC density and hourly mean HR. Twenty-four-hour Holter electrocardiograms were performed before and 1 to 3 months after the initiation of therapy.There were no significant between-group differences in the baseline characteristics. Both the TB (from 14.6 [9.9-19.2] to 7.6 [1.7-15.8]%, P < 0.001) and OB (from 13.2 [7.6-21.9] to 4.6 [0.5-17.0]%, P = 0.0041) significantly decreased the PVC density, and there was no significant difference between the two groups (P = 0.73). Compared to OB, the TB had similar effects in reducing the PVC density for P-PVCs (P = 0.96), and NP-PVCs (P = 0.71). The TB significantly decreased the P-PVC density from baseline not only during day-time (P < 0.001) but also night-time (P = 0.0017), while the OB did not significantly decrease the P-PVC density from baseline during night-time (P = 0.17).Compared to OB, the TB could be used with the same efficacy of reducing idiopathic PVCs. The TB may be a more useful therapeutic agent than OB for P-PVCs during a 24-hour period.


Asunto(s)
Antagonistas de Receptores Adrenérgicos beta 1/administración & dosificación , Bisoprolol/administración & dosificación , Complejos Prematuros Ventriculares/tratamiento farmacológico , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
7.
Int Heart J ; 61(1): 21-28, 2020 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-31956136

RESUMEN

Catheter ablation is currently an established treatment for symptomatic paroxysmal atrial fibrillation (AF). We focused on elderly patients with a high prevalence of AF and attempted to identify the clinical factors associated with unsuccessful ablation outcomes.Among 735 consecutive patients who underwent AF ablation procedures, 108 (14.7%, 66 men) aged ≥ 75 years were included. Of them, 80 had paroxysmal AF, and the remaining 28 non-paroxysmal AF. All patients underwent pulmonary vein (PV) isolation and occasionally additional ablation. When AF recurred, redo ablation procedures were performed if the patient so desired.The mean number of ablation procedures was 1.1 ± 0.4 times per patient. During a mean follow-up of 38.7 ± 21.7 months, sinus rhythm was maintained in 100 patients (92.6%) without any antiarrhythmic drugs, but not in the remaining 8 (7.4%). Left atrial diameter (LAD, P < 0.001), left ventricular (LV) systolic diameter (P < 0.001), LV diastolic diameter (P = 0.001), non-PV AF foci (P = 0.036), and diabetes (P = 0.045) were associated with unsuccessful ablation procedures. Multivariate logistic regression analysis revealed a large LAD and non-PV AF foci were significant independent predictors of AF recurrences, with odds ratios of 0.76 (P = 0.019) and 0.04 (P = 0.023), respectively. In a total of 124 procedures, one major (0.8%) and 11 minor (8.9%) complications occurred.In elderly AF patients, catheter ablation of AF is effective and safe. Non-PV AF foci and a large LAD were independent clinical predictors of unsuccessful AF ablation outcomes.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/fisiopatología , Femenino , Humanos , Modelos Logísticos , Masculino , Tempo Operativo , Recurrencia , Reoperación , Resultado del Tratamiento
8.
Heart Vessels ; 34(4): 641-649, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30406286

RESUMEN

Indoxyl sulfate (IS), a protein-bound uremic toxin, induces renal disorders and atrial fibrillation (AF). It is well known that renal dysfunction is a risk factor for AF and radiofrequency catheter ablation (RFCA) improves the renal function. However, the improvement in the renal function after RFCA in patients with early stage chronic kidney disease (CKD) and the serial changes in the IS level have not been fully elucidated. This study aimed to investigate whether IS affects the improvement in the renal function. A total of 91 consecutive patients with mild kidney dysfunction (CKD stage I-II) who underwent RFCA and maintained sinus rhythm were prospectively enrolled. The plasma IS level and estimated glomerular filtration rate (eGFR) were determined before, 3 months, and 1 year after RFCA. The patients were divided according to the IS quartiles (Q1-4; < 0.4, 0.4-0.7, 0.7-1.2, and > 1.2 µg/ml). There was no significant difference in the eGFR among the IS quartiles. A significantly higher eGFR improvement rate was obtained for IS-Q4 than the other quartiles (p = 0.039). The IS-Q4 IS level significantly decreased at 1 year after RFCA (1.8 ± 0.8 to 1.2 ± 0.7 µg/ml, p < 0.01). The multivariable logistic model revealed that a high-IS level (IS-Q4) was an independent predictor of an eGFR improvement (OR 3.33; 95% CI 1.16-9.59; p = 0.026). A high-IS level reduction after RFCA improved the renal function in AF patients with mild kidney dysfunction.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Tasa de Filtración Glomerular/fisiología , Indicán/sangre , Insuficiencia Renal Crónica/sangre , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/fisiopatología , Biomarcadores/sangre , Cromatografía Líquida de Alta Presión , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/fisiopatología , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad
9.
Int Heart J ; 60(1): 129-135, 2019 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-30464134

RESUMEN

The progression of renal dysfunction reduces serum albumin and deteriorates the binding capacity of protein-bound uremic toxins. We evaluated the prognostic implications of serum indoxyl sulfate (IS) and albumin levels in patients with cardiovascular disease.We prospectively enrolled 351 consecutive patients undergoing percutaneous revascularization for coronary artery disease or peripheral artery disease. The primary endpoint was all-cause mortality. Patients were assigned to four groups according to the median levels of serum IS (0.1 mg/dL) and albumin (3.9 g/dL).During the median follow-up time of 575 days, 16 patients died. The IS level was significantly higher in nonsurvivors (0.33 versus 0.85 mg/dL, P < 0.05). On the Kaplan-Meier curve, the high IS/low albumin group presented the highest mortality rate (log-rank test, P < 0.01). Cox proportional hazard analysis revealed that high IS/low albumin (hazard ratio (HR): 5.33; 95% confidence interval (CI): 1.71-16.5; P < 0.01), diastolic pressure (HR: 0.94; 95% CI: 0.91-0.98; P < 0.01), prior stroke (HR: 4.54; 95% CI: 1.33-15.4; P = 0.01), and left ventricular ejection fraction (LVEF) (HR: 0.92; 95% CI: 0.88-0.96; P < 0.001) were associated with increased mortality. Furthermore, the combination of IS and albumin levels significantly conferred an additive value to LVEF for predicting mortality (C-statistic: 0.69 versus 0.80; P < 0.001; net reclassification improvement: 0.83; P < 0.001; integrated discrimination improvement: 0.02; P = 0.02).A lower albumin level adds potentiating effects on IS as a prognostic factor for cardiovascular disease.


Asunto(s)
Síndrome Cardiorrenal/sangre , Enfermedades Cardiovasculares/sangre , Indicán/sangre , Albúmina Sérica/análisis , Toxinas Biológicas/sangre , Anciano , Síndrome Cardiorrenal/mortalidad , Enfermedades Cardiovasculares/mortalidad , Enfermedad de la Arteria Coronaria/terapia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Mortalidad , Intervención Coronaria Percutánea/métodos , Enfermedad Arterial Periférica/terapia , Pronóstico , Estudios Prospectivos , Factores de Riesgo , Volumen Sistólico/fisiología
10.
Circ J ; 82(12): 3082-3089, 2018 11 24.
Artículo en Inglés | MEDLINE | ID: mdl-30298852

RESUMEN

BACKGROUND: Obesity has previously been identified as an indicator of good prognosis in patients undergoing transcatheter aortic valve implantation (TAVI), an association known as the "obesity paradox". We investigated whether abdominal total fat area (TFA), visceral fat area (VFA), or subcutaneous fat area (SFA) are prognostic indicators of long-term clinical outcome in patients undergoing TAVI. Methods and Results: We retrospectively analyzed 100 consecutive patients who underwent TAVI between December 2013 and April 2017. TFA, VFA, and SFA were measured from routine pre-procedural computed tomography (CT). Patients were divided into 2 groups according to median TFA, VFA, or SFA, and we investigated the association of abdominal fat area with adverse clinical events, including all-cause death and re-hospitalization due to worsening heart failure. At a median follow-up of 665 days, patients with higher SFA had significantly lower incidence of the composite outcome and all-cause death compared with patients with lower SFA (15.0% vs. 37.7%, P=0.025; and 8.9% vs. 23.7%, P=0.047, respectively). In contrast, patients with higher TFA or VFA did not show significant reduction in the incidences of the composite outcome or all-cause mortality. CONCLUSIONS: CT-derived SFA had prognostic value in patients undergoing TAVI.


Asunto(s)
Grasa Abdominal/diagnóstico por imagen , Estenosis de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Tomografía Computarizada por Rayos X , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Supervivencia sin Enfermedad , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Estudios Retrospectivos , Tasa de Supervivencia
11.
Int Heart J ; 59(6): 1253-1260, 2018 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-30393261

RESUMEN

The SelectSecure™ lead system (SSLS), which is composed of a thin lumenless, active-fixation lead and a deflectable catheter, is approved for use in Japan. This study aimed to evaluate the long-term clinical outcomes of right ventricular (RV) septal pacing with the SSLS along with the system's safety and electrical performance. A total of 129 patients were divided into the following 3 groups: the RV septal pacing with the SSLS group (SSP, n = 21); the RV septal pacing with the conventional lead group (Septal, n = 77); and the RV apical pacing with the conventional lead group (Apical, n = 31). All lead-related complications and pacing parameters during follow-up were compared among the groups. The clinical outcome was heart failure-associated hospitalization. The SSP and Septal groups showed significantly shorter paced QRS duration than the Apical group. During the follow-up for a mean of 49.5 ± 13.1 months, no lead-related complications occurred in any of the groups. A case of pericardial effusion occurred in the SSP group, but cardiac tamponade did not occur, and it spontaneously resolved. The ventricular pacing threshold after the follow-up period was higher in the SSP group than in the other 2 groups. There was no difference in the primary heart failure hospitalization among the 3 groups. The SSLS could be effective in producing a narrow QRS width with RV septal pacing, but its pacing threshold was higher than conventional leads in the chronic phase.


Asunto(s)
Catéteres Cardíacos , Estimulación Cardíaca Artificial/métodos , Insuficiencia Cardíaca/prevención & control , Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Femenino , Estudios de Seguimiento , Ventrículos Cardíacos , Hospitalización/estadística & datos numéricos , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Resultado del Tratamiento
12.
Int Heart J ; 57(1): 30-4, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26742885

RESUMEN

Although oral amiodarone (AMD) has been used for the management of atrial fibrillation (AF), serious complications such as interstitial pneumonia (IP) occur very occasionally. We evaluated which factors were associated with the development of IP under the long-term administration of AMD in patients with refractory AF.This study included 122 consecutive patients (65.8 ± 11.4 years, mean body mass index [BMI] of 23.2 ± 4.3 kg/m(2)) who orally received AMD to inhibit AF between January 2004 and December 2013. Administration of AMD was begun at 400 mg daily as a loading dose, and was continued at a dosage of 50-400 mg daily after the initial loading phase, determined by the control of the arrhythmias and occurrence of side-effects. The clinical factors were compared between the patients with and without adverse effects, especially IP.During an average follow-up period of 49.2 ± 28.2 months, 53 patients (43.4%) were determined to have converted and maintained sinus rhythm. In contrast, adverse effects were detected in 46 patients (37.7%) with AMD. IP occurred in 8 patients (6.6%), thyrotoxicosis in 35 (28.7%), and others in 5 (4.1%). Four (50.0%) out of 8 patients complicated with IP had obesity (BMI > 27 kg/m(2)). Among the clinical factors, only obesity was significantly associated with the development of IP (P = 0.026).In patients with refractory AF, AMD had an antiarrhythmic effect with long-term administration, but greater adverse effects were also observed. Obesity was the most significant factor associated with the development of IP.


Asunto(s)
Amiodarona/administración & dosificación , Fibrilación Atrial/tratamiento farmacológico , Enfermedades Pulmonares Intersticiales/complicaciones , Obesidad/etiología , Administración Oral , Anciano , Anciano de 80 o más Años , Amiodarona/efectos adversos , Antiarrítmicos/administración & dosificación , Fibrilación Atrial/etiología , Índice de Masa Corporal , Relación Dosis-Respuesta a Droga , Femenino , Estudios de Seguimiento , Humanos , Enfermedades Pulmonares Intersticiales/diagnóstico , Masculino , Persona de Mediana Edad , Obesidad/diagnóstico , Pronóstico , Estudios Retrospectivos , Factores de Riesgo
13.
Intern Med ; 2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-38960690

RESUMEN

Cryoballoon ablation has been established as an effective method for pulmonary vein isolation and has recently been investigated for its efficacy of substrate modification on the left atrial roof area in patients with persistent atrial fibrillation. We herein report the first successful case of left atrial posterior wall isolation including roof line ablation using cryoballoons in a patient with persistent atrial fibrillation, dextrocardia, and situs inversus. Cryoballoon ablation proved to be a safe and straightforward approach to create lasting lesions along the left atrial roof line and left atrial posterior wall, even under challenging anatomical conditions.

14.
Circ Rep ; 6(3): 37-45, 2024 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-38464985

RESUMEN

Background: Catheter ablation (CA) of atrial fibrillation (AF) triggers, including non-pulmonary vein (PV) foci, contributes to improved procedural outcomes. However, the clinical significance of an AF trigger ablation during second CA procedures for nonparoxysmal AF is unknown. Methods and Results: We enrolled 94 patients with nonparoxysmal AF undergoing a second CA. Intracardiac cardioversion during AF using high-dose isoproterenol was performed to determine the presence or absence of AF triggers. PV re-isolations were performed if PV potentials recurred, and if AF triggers appeared from any non-PV sites, additional ablation was added to those sites. We investigated the incidence of atrial arrhythmia recurrence (AAR) >3 months post-CA. Of the 94 enrolled patients, AF triggers were identified in 65 (69.1%), and of those with AF triggers, successful elimination of the triggers was achieved in 47 patients (72.3%). Multivariate analysis revealed that no observed AF triggers were a significant predictor of AAR (hazard ratio [HR] 1.97, 95% confidence interval [CI] 1.21-3.46, P=0.019). In a subanalysis of the patients with AF triggers, multivariate analysis showed that unsuccessful trigger ablation was significantly associated with AAR (HR 5.84, 95% CI 2.79-12.22, P<0.01). Conclusions: Having no observed AF triggers during a second CA session significantly increased the risk of AAR, as did unsuccessful CA of AF triggers.

15.
JACC Cardiovasc Imaging ; 17(4): 396-407, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37921717

RESUMEN

BACKGROUND: Quantification of myocardial changes in severe aortic stenosis (AS) is prognostically important. The potential for comprehensive myocardial assessment pre-transcatheter aortic valve replacement (TAVR) by computed tomography angiography (CTA) is unknown. OBJECTIVES: This study sought to evaluate whether quantification of left ventricular (LV) extracellular volume-a marker of myocardial fibrosis-and global longitudinal strain-a marker of myocardial deformation-at baseline CTA associate with post-TAVR outcomes. METHODS: Consecutive patients with symptomatic severe AS between January 2021 and June 2022 who underwent pre-TAVR CTA were included. Computed tomography extracellular volume (CT-ECV) was derived from septum tracing after generating the 3-dimensional CT-ECV map. Computed tomography global longitudinal strain (CT-GLS) used semi-automated feature tracking analysis. The clinical endpoint was the composite outcome of all-cause mortality and heart failure hospitalization. RESULTS: Among the 300 patients (80.0 ± 9.4 years of age, 45% female, median Society of Thoracic Surgeons Predicted Risk of Mortality score 2.80%), the left ventricular ejection fraction (LVEF) was 58% ± 12%, the median CT-ECV was 28.5% (IQR: 26.2%-32.1%), and the median CT-GLS was -20.1% (IQR: -23.8% to -16.3%). Over a median follow-up of 16 months (IQR: 12-22 months), 38 deaths and 70 composite outcomes occurred. Multivariable Cox proportional hazards model, accounting for clinical and echocardiographic variables, demonstrated that CT-ECV (HR: 1.09 [95% CI: 1.02-1.16]; P = 0.008) and CT-GLS (HR: 1.07 [95% CI: 1.01-1.13]; P = 0.017) associated with the composite outcome. In combination, elevated CT-ECV and CT-GLS (above median for each) showed a stronger association with the outcome (HR: 7.14 [95% CI: 2.63-19.36]; P < 0.001). CONCLUSIONS: Comprehensive myocardial quantification of CT-ECV and CT-GLS associated with post-TAVR outcomes in a contemporary low-risk cohort with mostly preserved LVEF. Whether these imaging biomarkers can be potentially used for the decision making including timing of AS intervention and post-TAVR follow-up will require integration into future clinical trials.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Función Ventricular Izquierda , Volumen Sistólico , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Valor Predictivo de las Pruebas , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Estudios Retrospectivos
16.
JACC Case Rep ; 29(12): 102372, 2024 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-38774636

RESUMEN

The diagnostic approach toward the management of cardiac implantable electronic device-related tricuspid regurgitation is challenging and undefined. Functional cardiac computed tomography angiography provides a complementary role to echocardiography in the evaluation of lead-leaflet interaction which can help the clinical decision-making process, as presented in this case series.

17.
Circ Cardiovasc Interv ; : e013903, 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38934113

RESUMEN

BACKGROUND: SAPIEN3 (S3) is a ubiquitous redo-transcatheter aortic valve (TAV) replacement alternative for degenerated Evolut valves, but S3 sizing for S3-in-Evolut remains unclear. We sought to compare the impact of in vivo computed tomography (CT)-sizing on redo-TAV feasibility for S3-in-Evolut with traditional bench-sizing. METHODS: CT scans of 290 patients treated using Evolut R/PRO/PRO+ between July 2015 and December 2021 were analyzed. S3-in-Evolut was simulated using S3 outflow/neoskirt plane (NSP) at node-6, -5, and -4. CT-sizing for S3 was determined by averaging 4 areas of the Evolut stent frame at NSP level and 3 nodes below. Redo-TAV was deemed feasible if the NSP was below the coronaries, or the narrowest valve (virtual S3)-to-aorta distance was >4 mm. Risk of prosthesis-patient mismatch was estimated using predicted indexed-effective orifice area. RESULTS: Compared with bench-sizing, CT-sizing yielded smaller S3 size in 82% at node-6, 81% at node-5, and 84% at node-4. Factors associated with CT-sizing less than bench-sizing were larger index Evolut size, underexpansion of index Evolut, and shallower implant depth (all P<0.05). CT-sizing increased redo-TAV feasibility by +8% at node-6, +10% at node-5, and +4% at node-4. Redo-TAV feasibility increased with annulus size, sinotubular junction dimensions, coronary heights, index Evolut size, deeper Evolut implant depth, and lower NSP levels (all P<0.05). CT-sizing had a slightly higher estimated risk of severe prosthesis-patient mismatch (9% at node-6, 7% at node-5, and 6% at node-4), which could be mitigated by changing the NSP. CONCLUSIONS: CT-sizing for S3-in-Evolut is associated with higher feasibility of redo-TAV compared with bench-sizing, potentially reducing the risk of excessive oversizing and S3 underexpansion. Further validation using real-world clinical data is necessary.

18.
Ann Thorac Surg ; 117(6): 1154-1162, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38382704

RESUMEN

BACKGROUND: Selection of transcatheter valve size using preprocedural computed tomography (CT) is standardized and well established. However, valve sizing for surgical aortic valve replacement (SAVR) is currently performed intraoperatively by using sizers, which may result in variation among operators and risk for prosthesis-patient mismatch. This study evaluated the usefulness of CT annulus measurement for SAVR valve sizing. METHODS: This study included patients who underwent SAVR using Inspiris or Magna Ease and received preoperative electrocardiogram-gated CT imaging. Starting from June 2022, study investigators applied a CT sizing algorithm using CT-derived annulus size to guide minimum SAVR label size. The final decision of valve selection was left to the operating surgeon during SAVR. The study compared the appropriateness of valve selection (comparing implanted size with CT-predicted size) and prosthesis-patient mismatch rates without aortic root enlargement between 2 cohorts: 102 cases since June 2022 (CT sizing cohort) and 180 cases from 2020 to 2021 (conventional sizing cohort). RESULTS: Implanted size smaller than CT predicted size and severe prosthesis-patient mismatch were significantly lower by CT sizing than by conventional sizing (12% vs 31% [P = .001] and 0% vs 6% [P = .039], respectively). Interoperator variability was a factor associated with implanted size smaller than CT predicted with conventional sizing, whereas it became nonsignificant with CT sizing. CONCLUSIONS: Applying CT sizing to SAVR led to improved valve size selection, less prosthesis-patient mismatch, and less interoperator variability. CT sizing for SAVR could also be used to predict prosthesis-patient mismatch before SAVR and identify patients who need aortic root enlargement.


Asunto(s)
Válvula Aórtica , Prótesis Valvulares Cardíacas , Tomografía Computarizada por Rayos X , Humanos , Femenino , Masculino , Tomografía Computarizada por Rayos X/métodos , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Anciano , Estudios Retrospectivos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Diseño de Prótesis , Anciano de 80 o más Años , Cuidados Preoperatorios/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos
19.
J Cardiovasc Comput Tomogr ; 17(3): 222-225, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36922309

RESUMEN

BACKGROUND: Computed tomography angiography (CTA) assessment of myocardial extracellular volume fraction (CT-ECV) is feasible, although the protocols for imaging acquisition and post-processing methodology have varied. We aimed to identify a pragmatic protocol for CT-ECV assessment encompassing both imaging acquisition and post-processing methodologies to facilitate its clinical implementation. METHODS: We evaluated consecutive patients with severe aortic stenosis undergoing evaluation for transcatheter aortic valve replacement (TAVR). Pre-contrast and 3-min-delayed CTA were obtained in systole using either helical prospective-ECG-triggered (high-pitch) or axial sequential-ECG-gated acquisition, adding to standard TAVR CTA protocol. Using a dedicated software for co-registration of CTA datasets, three methodologies for ECV measurement were evaluated: (1) mid-septum region of interest (Septal ECV), (2) averaged-global ECV (Global ECV) encompassing 16-AHA segments, and (3) average of septal and lateral segments (Averaged ECVsep and Averaged ECVlat). RESULTS: Among the 142 patients enrolled (median â€‹= â€‹81 years, 44% females), 8 were excluded due to significant imaging artifacts precluding Global ECV assessment. High-pitch scan mode was performed in 68 patients (48%). Suboptimal image quality for Global ECV assessment was associated with high-pitch scan mode (odds ratio: OR â€‹= â€‹2.26, p â€‹= â€‹0.036), along with the presence of intracardiac leads (OR â€‹= â€‹4.91, p â€‹= â€‹0.002), and BMI≥35 â€‹kg/m2 (OR â€‹= â€‹2.80, p â€‹= â€‹0.026). Septal ECV [median â€‹= â€‹29.4%] and Averaged ECVsep [29.0%] were similar (p â€‹= â€‹0.108), while Averaged ECVlat [27.5%] was lower than Averaged ECVsep (p â€‹< â€‹0.001), resulting in lower Global ECV [28.6%]. CONCLUSIONS: Myocardial CT-ECV assessment is feasible using a systolic sequential acquisition pre-contrast, and similar additional 3-min delayed scan. Septal ECV measurement provides similar values to Global ECV and is equally reproducible.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Femenino , Humanos , Masculino , Estudios Prospectivos , Valor Predictivo de las Pruebas , Tomografía Computarizada por Rayos X , Angiografía por Tomografía Computarizada/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía
20.
EuroIntervention ; 19(11): e937-e947, 2023 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-37899719

RESUMEN

BACKGROUND: The use of oversizing in mitral valve-in-valve (MViV) procedures can lead to non-uniform expansion of transcatheter heart valves (THV). This may have implications for THV durability. AIMS: The objective of this study was to assess the extent and predictors of THV deformation in MViV procedures. METHODS: We examined 33 patients who underwent MViV with SAPIEN prostheses. The extent of THV deformation (deformation index, eccentricity, neosinus volume, asymmetric leaflet expansion and vertical deformation) and hypoattenuating leaflet thickening (HALT) were assessed using cardiac computed tomography (CT), performed prospectively at 30 days post-procedure. For descriptive purposes, the THV deformation index was calculated, with values >1.00 representing a more hourglass shape. RESULTS: Non-uniform underexpansion of THV was common after MViV implantation, with a median expansion area of 74.0% (interquartile range 68.1-84.1) at the narrowest level and a THV deformation index of 1.21 (1.13-1.29), but circularity was maintained with eccentricity ranging from 0.24 to 0.28. The degree of oversizing was a key factor associated with greater underexpansion and a higher deformation index (ß=-0.634; p<0.001; ß=0.594; p<0.001, respectively). Overall, the incidence of HALT on the 30-day postprocedural CT was 27.3% (9 of 33). Most patients (32 of 33) were on anticoagulation therapy, but the prothrombin time and international normalised ratio (PT-INR) at the time of the CT scan was <2.5 in 23 of 32 patients. Among patients with a PT-INR of <2.5, HALT was predominantly observed with a high THV deformation index of ≥1.18. CONCLUSIONS: THV deformation, i.e., underexpansion and an hourglass shape, commonly occurs after MViV implantation and is negatively affected by excessive oversizing. Optimising THV expansion during MViV could potentially prevent HALT.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento , Diseño de Prótesis , Válvula Aórtica/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA