Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Tex Heart Inst J ; 50(2)2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36947442

RESUMEN

Late lumen enlargement after percutaneous coronary intervention (PCI) with drug-coated balloon has contributed to good clinical results. However, late lumen enlargement with drug-coated balloon following rotational atherectomy has not been well reported. This report describes a case of calcified napkin-ring ostial lesion at the left main trunk that showed a sustained lumen area after PCI with drug-coated balloon following rotational atherectomy. An 85-year-old female patient was admitted to the hospital with dyspnea. Echocardiography showed hypokinesis in the anteroseptal and inferior walls. Electrocardiograph-gated cardiac computed tomography showed a calcified ostial lesion in the left main trunk. Invasive angiography of the coronary artery showed severe stenosis in the left main trunk ostium. Percutaneous coronary intervention was performed with a drug-coated balloon after rotational atherectomy. The minimal lumen area measured by intravascular ultrasound grew mildly from 4.09 to 4.17 mm2 immediately after PCI. Follow-up angiography and intravascular ultrasound performed after 6 months showed that the minimal lumen area in the left main trunk ostium was further enlarged from 4.17 to 4.69 mm2. The presence of sustained lumen area after PCI with drug-coated balloon following rotational atherectomy for a napkin-ring left main trunk ostial lesion was confirmed. This case demonstrates sustained lumen area after drug-coated balloon following rotational atherectomy in the left main trunk ostium, improving the patient's chest symptom. Hence, drug-coated balloon after rotational atherectomy may be an option for complex stent sites, such as the left main trunk ostium in geriatric patients and sites with highly calcified lesions.


Asunto(s)
Angioplastia Coronaria con Balón , Aterectomía Coronaria , Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Femenino , Humanos , Anciano , Anciano de 80 o más Años , Angioplastia Coronaria con Balón/métodos , Paclitaxel , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Resultado del Tratamiento
2.
BMJ Case Rep ; 15(5)2022 05 03.
Artículo en Inglés | MEDLINE | ID: mdl-35504668

RESUMEN

While the vascular healing process after drug-eluting stent implantation is not fully elucidated, it is generally accepted that macrophages play an important role in inflammation. It is also known that macrophages involved in the pathogenesis of atherosclerosis may stem from several origins, that is, monocyte-derived macrophages versus resident macrophages. However, little is known about the role of human macrophages on reperfusion of culprit coronary arteries in patients with atherosclerotic disease who have sustained acute coronary syndrome. In this present case report, we describe the presence of cluster of differentiation (CD) 163-positive macrophages in close proximity to the stent struts at the luminal site 72 hours after drug-eluting stent implantation in the culprit coronary lesion for ST elevation myocardial infarction by postmortem examination.


Asunto(s)
Stents Liberadores de Fármacos , Infarto del Miocardio con Elevación del ST , Humanos , Macrófagos , Polímeros , Infarto del Miocardio con Elevación del ST/cirugía , Sirolimus/uso terapéutico , Stents , Resultado del Tratamiento
3.
BMJ Case Rep ; 14(7)2021 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-34301690

RESUMEN

Coronary artery fistula (CAF) is an uncommon congenital heart disease. Furthermore, aortopulmonary fistula is a rare congenital heart disease of adult onset. We report the case of a 79-year-old man who presented with chest pain. ECG-gated cardiac CT and coronary artery angiography revealed an anomalous vessel arising from the right coronary cusp and a CAF from the left coronary descending artery. These fistulas coalesced and drained into the same portion of the pulmonary artery. Haemodynamic studies revealed that the estimated systemic-to-pulmonary flow ratio was 1.18. The mean pulmonary pressure was 14 mm Hg. We decided against surgical intervention due to his advanced age and lack of heart failure symptoms. The patient did not have any worsening heart failure and chest pain on follow-up. This was a rare case of CAF coexistent and coalesced with an aortopulmonary fistula.


Asunto(s)
Fístula Arterio-Arterial , Anomalías de los Vasos Coronarios , Adulto , Anciano , Fístula Arterio-Arterial/complicaciones , Fístula Arterio-Arterial/diagnóstico por imagen , Fístula Arterio-Arterial/cirugía , Angiografía Coronaria , Anomalías de los Vasos Coronarios/complicaciones , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Anomalías de los Vasos Coronarios/cirugía , Humanos , Masculino , Arteria Pulmonar/anomalías , Arteria Pulmonar/diagnóstico por imagen
4.
Ann Vasc Dis ; 14(1): 31-38, 2021 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-33786097

RESUMEN

Objective: The correlation between lipoproteins and arterial thrombosis is not fully elucidated, and no data exist in terms of lipoprotein profiles before heparin administration in patients with coronary arterial thrombosis (CAT). This cross-sectional study aimed to evaluate the lipoprotein profile before heparin administration in 63 ST-segment elevation myocardial infarction (STEMI) patients with CAT. Methods: The lipoprotein profile was measured via polyacrylamide gel electrophoresis prior to heparin administration for primary percutaneous coronary intervention for STEMI. Age- and sex-matched subjects with <25% stenosis in stable coronary artery disease were enrolled as controls. Results: In the pre-heparin serum, the fraction of very-low-density lipoprotein (P=0.75) in STEMI patients was not different from that in controls, and the fraction of intermediate-density lipoprotein (P<0.01) in STEMI patients was significantly lower than that in controls. Although the fraction of small dense low-density lipoprotein (s-LDL) in STEMI patients was significantly higher than that in controls (P<0.01), 44% (28/63) of STEMI patients were negative for s-LDL. Conclusion: Although lipoproteins are a risk factor for atherosclerosis, lipoprotein profiles with CAT following atherosclerosis in STEMI are different from those profiles without CAT in stable coronary artery disease.

5.
ESC Heart Fail ; 8(5): 4187-4198, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34387398

RESUMEN

AIMS: Endothelial cell vascular endothelial growth factor receptor 2 (VEGFR-2) plays a pivotal role in angiogenesis, which induces physiological cardiomyocyte hypertrophy via paracrine signalling between endothelial cells and cardiomyocytes. We investigated whether a decrease in circulating soluble VEGFR-2 (sVEGFR-2) levels is associated with poor prognosis in patients with chronic heart failure (HF). METHODS AND RESULTS: We performed a multicentre prospective cohort study of 1024 consecutive patients with HF, who were admitted to hospitals due to acute decompensated HF and were stabilized after initial management. Serum levels of sVEGFR-2 were measured at discharge. Patients were followed up over 2 years. The outcomes were cardiovascular death, all-cause death, major adverse cardiovascular events (MACE) defined as a composite of cardiovascular death and HF hospitalization, and HF hospitalization. The mean age of the patients was 75.5 (standard deviation, 12.6) years, and 57% were male. Patients with lower sVEGFR-2 levels were older and more likely to be female, and had greater proportions of atrial fibrillation and anaemia, and lower proportions of diabetes, dyslipidaemia, and HF with reduced ejection fraction (<40%). During the follow-up, 113 cardiovascular deaths, 211 all-cause deaths, 350 MACE, and 309 HF hospitalizations occurred. After adjustment for potential clinical confounders and established biomarkers [N-terminal B-type natriuretic peptide (NT-proBNP), high-sensitivity cardiac troponin I, and high-sensitivity C-reactive protein], a low sVEGFR-2 level below the 25th percentile was significantly associated with cardiovascular death [hazard ratio (HR), 1.79; 95% confidence interval (CI), 1.16-2.74] and all-cause death (HR, 1.43; 95% CI, 1.04-1.94), but not with MACE (HR, 1.11; 95% CI, 0.86-1.43) or HF hospitalization (HR, 1.03; 95% CI, 0.78-1.35). The stratified analyses revealed that a low sVEGFR-2 level below the 25th percentile was significantly associated with cardiovascular death (HR, 1.76; 95% CI, 1.07-2.85) and all-cause death (HR, 1.49; 95% CI, 1.03-2.15) in the high-NT-proBNP group (above the median), but not in the low-NT-proBNP group. Notably, the patients with high-NT-proBNP and low-sVEGFR-2 (below the 25th percentile) had a 2.96-fold higher risk (95% CI, 1.56-5.85) for cardiovascular death and a 2.40-fold higher risk (95% CI, 1.52-3.83) for all-cause death compared with those with low-NT-proBNP and high-sVEGFR-2. CONCLUSIONS: A low sVEGFR-2 value was independently associated with cardiovascular death and all-cause death in patients with chronic HF. These associations were pronounced in those with high NT-proBNP levels.


Asunto(s)
Insuficiencia Cardíaca , Factor A de Crecimiento Endotelial Vascular , Anciano , Anciano de 80 o más Años , Células Endoteliales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Prospectivos , Receptor 2 de Factores de Crecimiento Endotelial Vascular
7.
Circ J ; 74(10): 2097-102, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-20689221

RESUMEN

BACKGROUND: The Resolute stent is a newly developed system with a bio-histocompatible polymer that allows programmed drug delivery up to 180 days. The aim of this intravascular ultrasound (IVUS) analysis was to evaluate the short- (4 months) and mid-term (9 months) efficacy using the Resolute stent. METHODS AND RESULTS: Data were derived from the RESOLUTE trial, a prospective, multicenter, non-randomized, single-arm study to treat de novo native coronary artery lesions. This trial included 2 cohorts with different follow-up periods, and all enrollment patients in this trial received IVUS study. Follow-up IVUS was available in 24 patients (4-month group) and 88 patients (9-month group). Neointimal obstruction (%) was defined as neointimal volume divided by stent volume. Cross-sectional narrowing (CSN, %) was defined as neointimal area divided by stent area. No significant differences in vessel, lumen and stent volume at post-procedure were observed within stented segments between the 4- and 9-month follow-up groups. Although neointimal volume and % neointimal obstruction showed no significant difference between the 2 groups (% neointimal obstruction: 2.2 ± 2.5 vs 3.7 ± 4.0%, P=0.09), maximum CSN was significantly larger in the 9-month group. There were 7 cases of late incomplete stent apposition. CONCLUSIONS: These IVUS results showed minimum growth of neointimal proliferation by the Resolute stent throughout the stented segment up to 9 months follow up.


Asunto(s)
Vasos Coronarios/diagnóstico por imagen , Stents Liberadores de Fármacos/normas , Polímeros/uso terapéutico , Sirolimus/análogos & derivados , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Neointima/patología , Sirolimus/administración & dosificación , Factores de Tiempo , Ultrasonografía Intervencional
8.
Ann Vasc Dis ; 12(1): 103-104, 2019 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-30931071

RESUMEN

The mechanism of stent thrombus formation following percutaneous transluminal stent implantation in an artery is unclear. This case report describes a 72-year-old man who had a mobile thrombus in a Wallstent in the right iliac artery despite daily oral administration of 100 mg of aspirin. This Wallstent was implanted 14 years ago. The unique in vivo angioscopic images show a solid mobile thrombus with some projections which rubbed yellow plaque on the stent struts.

9.
Iperception ; 9(4): 2041669518790576, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30109015

RESUMEN

Assumed lighting direction in cast-shadow interpretation was investigated. Experiment 1 used an ambiguous object-shadow-matching task to measure bias in shadow-matching direction. The shadow-matching bias was largest when the lighting direction was on average 38.3° left from above (a median of 25.1°). Experiment 2 tested the effect of body posture (head orientation) on cast-shadow interpretation using stimuli aligned in a head-centrically vertical or horizontal orientation. The below-shadow (light-from-above) bias in the head-centric frame was robust across the sitting upright, reclining-on-the-left-side, reclining-on-the-right-side, and supine conditions. A right-shadow (light-from-left) bias in the head-centric frame was found for the sitting upright and reclining-on-the-right-side conditions. In the reclining-on-the-left-side condition, shadow biases to the gravitational below direction and head-centric right direction may have cancelled each other out. These results are consistent with findings from previous shape-from-shading studies, suggesting that the same light-source assumption is applied to shading and shadow interpretations.

10.
Cardiovasc Revasc Med ; 8(2): 99-102, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17574168

RESUMEN

BACKGROUND: Treatment of aorto-ostial renal artery stenosis has been associated with a lower procedural success and higher complication and restenosis rate, as compared to nonostial lesions. The design and delivery of currently available stent systems in ostial lesions can result in inaccurate stent positioning and placement leading to stent protrusion into the parent vessel lumen or geographic miss. A novel stent system (SquareOne Inc., Campbell, CA, USA) has been designed specifically for aorto-ostial lesions in the renal artery. This stent system aims to provide both tactile and visual confirmation of the ostium at the aorta, allow for improved accuracy during stent positioning and placement, provide complete scaffolding of the lesion at the aortic junction to the native vessel, and enable future vessel reaccess. METHODS: Stents (n=12) were implanted in both renal arteries of six swine. For histology, two animals were euthanized immediately after stent implantation, and each two animals were then followed up at 2 and 4 weeks, respectively. Intravascular ultrasound (IVUS) studies were performed immediately after stent implantation and at follow-up. RESULTS: Proper stent positioning and implantation was obtained in all animals. Angiographic and IVUS assessments indicated no dissection or thrombus formation. Histology demonstrated good apposition and endothelialization of the stent strut surface. CONCLUSION: The unique flared shape of this novel ostial stent system allows for improved accuracy during stent positioning and placement, as well as complete apposition and coverage/scaffolding of the similarly-shaped luminal ostium. Future studies will determine if this novel stent system fulfills the unmet clinical need in aorto-ostial stenoses.


Asunto(s)
Angioplastia de Balón/instrumentación , Aorta , Obstrucción de la Arteria Renal/terapia , Arteria Renal , Stents , Animales , Aorta/diagnóstico por imagen , Aorta/patología , Aortografía , Estudios de Factibilidad , Modelos Animales , Diseño de Prótesis , Radiografía Intervencional , Arteria Renal/diagnóstico por imagen , Arteria Renal/patología , Obstrucción de la Arteria Renal/diagnóstico por imagen , Obstrucción de la Arteria Renal/patología , Proyectos de Investigación , Porcinos , Factores de Tiempo , Ultrasonografía Intervencional
11.
Kyobu Geka ; 60(12): 1083-9, 2007 Nov.
Artículo en Japonés | MEDLINE | ID: mdl-18018651

RESUMEN

Transient left ventricular dysfunction with chest symptoms and electrocardiographic changes mimicing those of acute myocardial infarction is known as takotsubo cardiomyopathy (TC). Because early left ventriculography reveals peculiar wall motion abnormalities and a balloon-shaped left ventricle, this was named takotsubo. Although the pathogenesis of TC remains unclear, physical or emotional stress is common in the majority of reported cases. The central role of sympathetic stimulation in TC is suggested by elevations in plasma catecholamine. Recently, TC cases occurring in perioperative period have been reported. Excessive perioperative catecholamine release, following deep anxiety or physical stress including pain, is likely to cause TC. We provide a brief review of, and comments on TC in perioerative period for surgeons.


Asunto(s)
Cardiomiopatía de Takotsubo , Biomarcadores/sangre , Catecolaminas/sangre , Diagnóstico por Imagen , Electrocardiografía , Humanos , Japón/epidemiología , Pronóstico , Estrés Fisiológico/complicaciones , Estrés Psicológico/complicaciones , Cardiomiopatía de Takotsubo/epidemiología , Cardiomiopatía de Takotsubo/etiología , Cardiomiopatía de Takotsubo/fisiopatología , Cardiomiopatía de Takotsubo/cirugía
12.
Iperception ; 8(6): 2041669517747891, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29344331

RESUMEN

A new illusion is reported. A visual object suddenly appearing on a red background sometimes causes an impression of flicker or double flash. In Experiment 1, a red, green, or blue object was presented on a red, green, blue, or gray background. Participants evaluated the illusion strength in reference to the physical flicker of a gray object presented in central vision. The results show that the green or blue object presented on the red background caused the illusion. In Experiment 2, the effect of retinal eccentricity on the illusion was tested. The results showed that the illusion was weak in central vision but became stronger as the retinal eccentricity of the objects' presentation increased. In Experiment 3, optimal luminance conditions for the illusion were explored with the green and blue objects. The illusion was strong when object luminance was lower than background luminance and the optimal luminance for the blue object was lower than that for the green object. We propose a tentative theory for the illusion and discuss its cause.

13.
Iperception ; 8(1): 2041669516682267, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28210485

RESUMEN

Previous studies have demonstrated that the perception of shading is based upon assumptions about lighting direction, for example, light from above. However, it is not clear whether these assumptions are used in the perception of cast shadows. Moreover, it is unclear whether a perceptual interaction exists between shading and cast shadows because until now they have been studied separately. In this study, we investigated through three experiments whether the light-from-above (or another direction) assumption is used in interpreting ambiguous cast shadows, and whether shading information influences the interpretation of cast shadows. Our results indicate the existence of the light-from-above assumption in interpreting cast shadows. Consistent shading information enhanced the interpretation, and judgments of lighting direction were also based on both cast shadow and shading information. However, the perceptual determination of shape from shading was relatively independent of the cast shadow interpretation or the lighting direction judgments of the scene.

14.
Am J Cardiol ; 97(9): 1322-5, 2006 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-16635604

RESUMEN

This study examined whether coronary focal vasospasm occurs in a nonuniform distribution within the coronary tree and whether a longitudinal plaque distribution pattern is present in patients with vasospastic angina using 3-dimensional intravascular ultrasound analysis. Of 121 patients with clinically suspected angina without fixed stenosis in the coronary arteries, vasospasm was provoked in 82 patients with 92 lesions (42 focal, 50 diffuse) by intravenous ergonovine maleate injection. Most focal vasospasms occurred in the proximal third of the coronary arteries (proximal 28, mid 8, distal 6, p <0.01), corresponding to the historical high-risk zones for acute coronary occlusion. More plaque burden also existed in the proximal third of the coronary arteries in patients with focal vasospasm.


Asunto(s)
Angina de Pecho/diagnóstico por imagen , Vasoespasmo Coronario/inducido químicamente , Vasoespasmo Coronario/diagnóstico por imagen , Ergonovina , Vasoconstrictores , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Electrocardiografía , Femenino , Humanos , Imagenología Tridimensional , Inyecciones Intravenosas , Masculino , Persona de Mediana Edad , Ultrasonografía Intervencional
15.
Am Heart J ; 150(2): 287, 2005 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16086932

RESUMEN

BACKGROUND: Plaque stabilization by statins is important for reduction of cardiovascular events but has not been demonstrated enough in vivo. We examined whether statins clinically alter the structure of coronary atherosclerotic plaques using intravascular ultrasound (IVUS) radio-frequency (RF) signal analysis. METHODS: Fifty consecutive patients undergoing percutaneous coronary intervention were enrolled. Intravascular ultrasound radio-frequency signals were acquired from non-percutaneous coronary intervention-targeted echolucent plaques. The patients were randomly assigned into 2 groups: group S (n = 25) taking atorvastatin 10 mg/d and group C (n = 25) as control. After 6-month follow-up, IVUS-RF signals were sampled at the same plaque sites. Several regions of interest were placed on each plaque. Intravascular ultrasound radio-frequency parameters were blindly calculated in all regions of interests (group S, n = 148; group C, n = 191). Targeted plaque volumes were also measured. Those data were compared between baseline and follow-up. RESULTS: In group S after 6 months, plasma low-density lipoprotein level was significantly decreased (133 +/- 13 to 87 +/- 29 mg/dL, P < .0001), integrated backscatter of IVUS-RF signals was substantially increased (-53.8 +/- 4.5 to -51.2 +/- 4.9 dB, P < .0001), and plaque volume was significantly reduced, whereas no change was demonstrated in group C. CONCLUSIONS: These results suggest that statins alter properties as well as volumes of coronary plaques within 6 months, which may be related to plasma low-density lipoprotein reduction. Intravascular ultrasound radio-frequency signal analysis may be useful to evaluate the effects of drugs on stabilization of coronary atherosclerotic plaques.


Asunto(s)
LDL-Colesterol/sangre , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Ácidos Heptanoicos/uso terapéutico , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Hipercolesterolemia/tratamiento farmacológico , Pirroles/uso terapéutico , Ultrasonografía Intervencional , Anciano , Angina de Pecho/sangre , Angina de Pecho/etiología , Angina de Pecho/terapia , Angioplastia Coronaria con Balón , Atorvastatina , Fármacos Cardiovasculares/uso terapéutico , Comorbilidad , Enfermedad de la Arteria Coronaria/sangre , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/etiología , Femenino , Estudios de Seguimiento , Humanos , Hipercolesterolemia/sangre , Hipercolesterolemia/complicaciones , Hipercolesterolemia/dietoterapia , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Ondas de Radio , Método Simple Ciego , Resultado del Tratamiento
16.
Am J Cardiol ; 96(9): 1237-41, 2005 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-16253589

RESUMEN

The effect of lesion characteristics on neointimal hyperplasia after sirolimus-eluting stent implantation was examined in 45 patients who underwent successful preinterventional intravascular ultrasound. There were no differences in neointimal hyperplasia between the moderate/severe calcified lesion group (calcium arc >120 degrees ) and the non/mild calcified lesion group or between the positive vessel remodeling group (external elastic membrane area at the minimal lumen area site larger than that at the proximal reference site) and negative vessel remodeling group. No correlation between preinterventional plaque burden and neointimal hyperplasia was found. In patients who have coronary artery disease, sirolimus-eluting stents continue to demonstrate striking suppression of neointimal proliferation, irrespective of lesion characteristics previously associated with greater restenotic risk.


Asunto(s)
Implantación de Prótesis Vascular/instrumentación , Materiales Biocompatibles Revestidos/efectos adversos , Reestenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Sirolimus/farmacología , Stents/efectos adversos , Ultrasonografía Intervencional , Implantación de Prótesis Vascular/efectos adversos , Reestenosis Coronaria/etiología , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/cirugía , Vasos Coronarios/cirugía , Progresión de la Enfermedad , Método Doble Ciego , Femenino , Estudios de Seguimiento , Humanos , Hiperplasia/diagnóstico por imagen , Inmunosupresores/farmacología , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Estudios Prospectivos , Falla de Prótesis , Factores de Riesgo , Índice de Severidad de la Enfermedad , Túnica Íntima/diagnóstico por imagen , Túnica Íntima/patología
17.
Ann Vasc Dis ; 8(4): 297-301, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26730254

RESUMEN

OBJECTIVE: Platelet-derived growth factor (PDGF) induces matrix metalloproteinase (MMP), which is regarded as a biomarker of plaque rupture or vulnerability. The aim of this study is to investigate those interactions in human coronary arteries at the onset of ST-segment elevation myocardial infarction (STEMI). METHODS: Thirty-two patients with STEMI who underwent primary percutaneous coronary intervention (PCI) were enrolled in this study. Plasma levels of PDGF-BB and MMP-9 were measured from infarct-related artery (IRA) and from femoral artery (FA) during PCI. RESULTS: Plasma levels of PDGF-BB and MMP-9 in the IRA were significantly higher than those in the FA (PDGF-BB: median 3130 pg/ml, IQR (interquartile range): 2020 to 4375 pg/ml vs. median 2605 pg/ml, IQR: 1305 to 3290 pg/ml, p <0.01, MMP-9: median 49 ng/ml, IQR: 35 to 100 ng/ml vs. median 42 ng/ml, IQR: 27 to 78 ng/ml, p = 0.04, IRA and FA, respectively). CONCLUSIONS: This in vivo study demonstrated that PDGF-BB with MMP-9 seems to play a role in coronary plaque instability in acute phase of STEMI.

20.
Cardiovasc Revasc Med ; 13(2): 111-8, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22406056

RESUMEN

BACKGROUND: Dedicated IVUS analyses of the second CObalt chromium STent with Antiproliferative for Restenosis (COSTAR II) trial have not been documented. We aim to compare IVUS findings between CoStar paclitaxel-eluting stent (PES) and Taxus PES in patients enrolled in the COSTAR II trial. We also attempted to examine the possible regional impact of multiple stenting. METHODS AND MATERIALS: Among the 1700 patients enrolled, 238 were assigned to an IVUS cohort including 168 patients treated by provisional multiple stenting. At 9 months, qualitative and quantitative IVUS observations including incomplete stent apposition (ISA) and neointimal proliferation (neointimal obstruction: neointimal volume/stent volume ×100) were compared between CoStar and Taxus PESs. RESULTS: In qualitative analysis, late-acquired ISA was observed in 1 patient treated by Taxus PES. Impaired strut continuity suggestive of stent fracture was observed in 2 out of 33 patients treated by multiple CoStar, and 4 out of 21 patients treated by multiple Taxus (P=.14). No such findings were found in single-stented patients in either stent subset. Quantitative analysis showed greater neointimal obstruction in CoStar (19.7%±13.4%, n=52) than in Taxus (10.7%±9.9%, n=38), whereas no significant difference in neointimal obstruction was found between single and multiple stenting in either CoStar or Taxus PES. CONCLUSIONS: The CoStar PES exhibits greater neointimal proliferation compared with Taxus PES at 9 months but with similar qualitative outcomes including late-acquired ISA. IVUS findings suggestive of stent fracture were found only in multiple-stenting cases irrespective of the stent used.


Asunto(s)
Aleaciones de Cromo , Enfermedad de la Arteria Coronaria/cirugía , Reestenosis Coronaria/prevención & control , Stents Liberadores de Fármacos , Neointima/prevención & control , Paclitaxel/farmacología , Ultrasonografía Intervencional/métodos , Antineoplásicos Fitogénicos/farmacología , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Electrocardiografía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Neointima/diagnóstico por imagen , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis , Método Simple Ciego , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA