Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Anaesthesia ; 70(8): 962-8, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25827168

RESUMEN

The VivaSight-DL(™) is a new single-use double-lumen endobronchial tube with an integrated camera. We studied this device in 151 consecutive patients scheduled for elective thoracic surgery in four different hospitals. Endobronchial intubation was successful in 148 patients (98%) (95% CI 94-99%). Median (IQR [range]) endobronchial intubation time was 59 (47-82 [17-932]) s and lung isolation was successfully achieved in 147 (99%) patients (95% CI 96-99%). A fibreoptic bronchoscope was required to assist endobronchial tube placement in 19 (13%) patients (95% CI 8-19%). Sore throat was reported by 37 (25%) patients (95% CI 18-33%), but no major complications were observed. We have reported the successful use of the VivaSight double-lumen tube for endobronchial intubation in a multicentre observational trial.


Asunto(s)
Intubación Intratraqueal/instrumentación , Anciano , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Procedimientos Quirúrgicos Torácicos
2.
Anaesthesia ; 68(1): 74-8, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23121322

RESUMEN

We studied tracheal intubation in manikins and patients with a camera embedded in the tip of the tracheal tube (Vivasight(™) ). Four people in two teams and two individuals attempted intubation of a manikin through an i-gel(™) 10 times each. The tracheas of 12 patients with a Mallampati grade of 1 were intubated with a Vivasight tracheal tube through a Berman airway, passed over a Frova(™) introducer. All 60 manikin intubations were successful, taking a mean (SD) time of 1.4 (0.5) s. The fastest intubation was performed in 0.5 s. All 12 participants' tracheas were successfully intubated in a median (IQR [range]) time of 90 (70-120 [50-210]) s. Seven participants complained of a sore throat, comparable with earlier findings for standard laryngoscopy and intubation: five mild; one moderate; and one severe. Tracheal intubation with the Vivasight through the i-gel or Berman airway is an alternative to existing techniques, against which it should be compared in randomised controlled trials in human participants. It has potential as a fast airway rescue technique.


Asunto(s)
Manejo de la Vía Aérea/instrumentación , Manejo de la Vía Aérea/métodos , Intubación Intratraqueal/instrumentación , Intubación Intratraqueal/métodos , Laringoscopios , Adulto , Análisis de Varianza , Anestesia General , Estudios de Factibilidad , Femenino , Humanos , Máscaras Laríngeas , Laringoscopía , Masculino , Maniquíes , Persona de Mediana Edad , Faringitis/epidemiología , Faringitis/etiología , Complicaciones Posoperatorias/epidemiología , Tamaño de la Muestra
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA